Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 13(6): e008716, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32370542

RESUMO

BACKGROUND: A novel ablation and mapping system can toggle between delivering biphasic pulsed field (PF) and radiofrequency energy from a 9-mm lattice-tip catheter. We assessed the preclinical feasibility and safety of (1) focal PF-based thoracic vein isolation and linear ablation, (2) combined PF and radiofrequency focal ablation, and (3) PF delivered directly atop the esophagus. METHODS: Two cohorts of 6 swine were treated with pulsed fields at low dose (PFLD) and high dose (PFHD) and followed for 4 and 2 weeks, respectively, to isolate 25 thoracic veins and create 5 right atrial (PFLD), 6 mitral (PFHD), and 6 roof lines (radiofrequency+PFHD). Baseline and follow-up voltage mapping, venous potentials, ostial diameters, and phrenic nerve viability were assessed. PFHD and radiofrequency lesions were delivered in 4 and 1 swine from the inferior vena cava onto a forcefully deviated esophagus. All tissues were submitted for histopathology. RESULTS: Hundred percent of thoracic veins (25 of 25) were successfully isolated with 12.4±3.6 applications/vein with mean PF times of <90 seconds/vein. Durable isolation improved from 61.5% PFLD to 100% with PFHD (P=0.04), and all linear lesions were successfully completed without incurring venous stenoses or phrenic injury. PFHD sections had higher transmurality rates than PFLD (98.3% versus 88.1%; P=0.03) despite greater mean thickness (2.5 versus 1.3 mm; P<0.001). PF lesions demonstrated homogenous fibrosis without epicardial fat, nerve, or vessel involvement. In comparison, radiofrequency+PFHD sections revealed similar transmurality but expectedly more necrosis, inflammation, and epicardial fat, nerve, and vessel involvement. Significant ablation-related esophageal necrosis, inflammation, and fibrosis were seen in all radiofrequency sections, as compared with no PF sections. CONCLUSIONS: The lattice-tip catheter can deliver focal PF to durably isolate veins and create linear lesions with excellent transmurality and without complications. The PF lesions did not damage the phrenic nerve, vessels, and the esophagus.


Assuntos
Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Irrigação Terapêutica , Potenciais de Ação , Animais , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Modelos Animais , Complicações Pós-Operatórias/patologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/patologia , Veias Pulmonares/fisiopatologia , Sus scrofa , Irrigação Terapêutica/efeitos adversos , Irrigação Terapêutica/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA