RESUMO
Recent advances in electrocardiographic monitoring and waveform analysis have significantly improved the ability to detect drug-induced changes in cardiac repolarization manifested as changes in the QT/corrected QT interval. These advances have also improved the ability to detect drug-induced changes in cardiac conduction. This White Paper summarizes current opinion, reached by consensus among experts at the Cardiac Safety Research Consortium, on the assessment of electrocardiogram-based safety measurements of the PR and QRS intervals, representing atrioventricular and ventricular conduction, respectively, during drug development.
Assuntos
Doenças Cardiovasculares/fisiopatologia , Sistema de Condução Cardíaco/efeitos dos fármacos , Antiarrítmicos/farmacologia , Ensaios Clínicos como Assunto , Descoberta de Drogas , Avaliação Pré-Clínica de Medicamentos , Eletrocardiografia , Humanos , Medição de RiscoRESUMO
Assessing the potential for a new drug to cause life-threatening arrhythmias is now an integral component of premarketing safety assessment. International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use Guideline (ICH) E14 recommends the "Thorough QT Study" (TQT) to assess clinical QT risk. Such a study calls for careful evaluation of drug effects on the electrocardiographic QT interval at multiples of therapeutic exposure and with a positive control to confirm assay sensitivity. Yet for some drugs and diseases, elements of the TQT Study may be impractical or unethical. In these instances, alternative approaches to QT risk assessment must be considered. This article presents points to consider for evaluation of QT risk when alternative approaches are needed.