1.
PLoS One ; 17(6): e0269286, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35709090

RESUMO

BACKGROUND: Severe hyperbilirubinemia is more frequent in low- and middle-income countries such as Indonesia than in high-income countries. One of the contributing factors might be the lack of adherence to existing guidelines on the diagnosis and treatment of hyperbilirubinemia. We developed a new national guideline for hyperbilirubinemia management in Indonesia. To help healthcare workers use this guideline, a web-based decision support tool application may improve both the adherence to the guideline and the care for infants with hyperbilirubinemia. METHODS: We developed a web-based application (BiliNorm) to be used on a smartphone that displays the bilirubin level of the patient on the nomogram and advises about the treatment that should be started. Healthcare workers of two teaching hospitals in East Java, Indonesia, were trained on the use of BiliNorm. At 6 months after the introduction, a questionnaire was sent to those who worked with the application enquiring about their experiences. An observational study was conducted in two time epochs. A chart review of infants with hyperbilirubinemia in the two hospitals was sent. The appropriateness of hyperbilirubinemia management during a 6-month period before BiliNorm introduction was compared to that during a 7-month period after its introduction. RESULTS: A total of 43 participants filled in the questionnaire, the majority (72%) of them indicated that BiliNorm was well received and easy to use. Moreover, 84% indicated that BiliNorm was helpful for the decision to start phototherapy. Chart review of 255 infants before BiliNorm introduction and that of 181 infants after its introduction indicated that significantly more infants had received treatment according to the guideline (38% vs 51%, p = 0.006). Few infants received phototherapy, but bilirubin level was not measured (14% vs 7%, p = 0.024). There was no difference in the proportion of infants who were over- and under-treated (34% vs 32% and 14% vs 10%, respectively). CONCLUSIONS: The web-based decision tool BiliNorm appears to be a valuable application. It is easy to use for healthcare workers and helps them adhere to the guideline. It improves the care for infants with hyperbilirubinemia and may help reduce the incidence of severe hyperbilirubinemia in Indonesia.


Assuntos
Doenças Hematológicas , Hiperbilirrubinemia Neonatal , Aplicativos Móveis , Bilirrubina , Humanos , Hiperbilirrubinemia/epidemiologia , Hiperbilirrubinemia Neonatal/terapia , Indonésia/epidemiologia , Recém-Nascido , Fototerapia
2.
Heliyon ; 6(9): e04950, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32995629

RESUMO

INTRODUCTION: A range of phototherapy devices are commercially available. The American Academy of Pediatrics (2004) recommends routine intensity measurement of phototherapy devices to ensure that babies affected by hyperbilirubinemia receive effective phototherapy. OBJECTIVE: The aims of this study were to calculate the irradiance decay velocity of phototherapy devices used in a tertiary care hospital to evaluate whether current maintenance procedures for phototherapy devices are effective, and to contribute to the improvement of a standardized maintenance procedure in daily practice, thus helping to ensure that all babies affected by hyperbilirubinemia receive prompt treatment. METHODS: This research represents a prospective observational study conducted at Dr. Soetomo Academic Teaching Hospital in Surabaya, Indonesia from February 2019-July 2019. The intensities of 11 phototherapy devices were measured at specific times using a Bili Blanket Meter II. We calculated the Δ irradiance differences in µW/cm2/nm and calculated them as velocity µW/cm2/nm/hour of use. RESULTS: Among the 11 phototherapy devices included in this study, nine were fluorescent and two were light-emitting diode (LED) machines. The mean (standard deviation) irradiance decay velocity of the fluorescent lamps was 0.02 (±0.03) µW/cm2/nm/hour of use, while that of the LED lamps was 0.015 (±0.007) µW/cm2/nm/hour of use. The fastest irradiance decay velocity was 0.08 µW/cm2/nm/hour of use, while the slowest irradiance decay velocity was <0.01 µW/cm2/nm/hour of use, both of which were from fluorescent-based devices. There was one fluorescent-based device that provided an intensity lower than the therapeutic level. CONCLUSION: Irradiance decay occurred in all phototherapy device lamps. It is important to perform routinely intensity measurements, regardless of manufacturer recommendations, to avoid ineffective phototherapy resulting from intensities lower than the required therapeutic levels.