Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Radiology ; 293(3): 554-564, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31638489

RESUMO

Background Ferumoxytol is approved for use in the treatment of iron deficiency anemia, but it can serve as an alternative to gadolinium-based contrast agents. On the basis of postmarketing surveillance data, the Food and Drug Administration issued a black box warning regarding the risks of rare but serious acute hypersensitivity reactions during fast high-dose injection (510 mg iron in 17 seconds) for therapeutic use. Whereas single-center safety data for diagnostic use have been positive, multicenter data are lacking. Purpose To report multicenter safety data for off-label diagnostic ferumoxytol use. Materials and Methods The multicenter ferumoxytol MRI registry was established as an open-label nonrandomized surveillance databank without industry involvement. Each center monitored all ferumoxytol administrations, classified adverse events (AEs) using the National Cancer Institute Common Terminology Criteria for Adverse Events (grade 1-5), and assessed the relationship of AEs to ferumoxytol administration. AEs related to or possibly related to ferumoxytol injection were considered adverse reactions. The core laboratory adjudicated the AEs and classified them with the American College of Radiology (ACR) classification. Analysis of variance was used to compare vital signs. Results Between January 2003 and October 2018, 3215 patients (median age, 58 years; range, 1 day to 96 years; 1897 male patients) received 4240 ferumoxytol injections for MRI. Ferumoxytol dose ranged from 1 to 11 mg per kilogram of body weight (≤510 mg iron; rate ≤45 mg iron/sec). There were no systematic changes in vital signs after ferumoxytol administration (P > .05). No severe, life-threatening, or fatal AEs occurred. Eighty-three (1.9%) of 4240 AEs were related or possibly related to ferumoxytol infusions (75 mild [1.8%], eight moderate [0.2%]). Thirty-one AEs were classified as allergiclike reactions using ACR criteria but were consistent with minor infusion reactions observed with parenteral iron. Conclusion Diagnostic ferumoxytol use was well tolerated, associated with no serious adverse events, and implicated in few adverse reactions. Registry results indicate a positive safety profile for ferumoxytol use in MRI. © RSNA, 2019 Online supplemental material is available for this article.


Assuntos
Meios de Contraste/efeitos adversos , Óxido Ferroso-Férrico/efeitos adversos , Imageamento por Ressonância Magnética , Uso Off-Label , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Sistema de Registros
2.
Kidney Int ; 92(1): 47-66, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28434822

RESUMO

Contrast-enhanced magnetic resonance imaging is a commonly used diagnostic tool. Compared with standard gadolinium-based contrast agents, ferumoxytol (Feraheme, AMAG Pharmaceuticals, Waltham, MA), used as an alternative contrast medium, is feasible in patients with impaired renal function. Other attractive imaging features of i.v. ferumoxytol include a prolonged blood pool phase and delayed intracellular uptake. With its unique pharmacologic, metabolic, and imaging properties, ferumoxytol may play a crucial role in future magnetic resonance imaging of the central nervous system, various organs outside the central nervous system, and the cardiovascular system. Preclinical and clinical studies have demonstrated the overall safety and effectiveness of this novel contrast agent, with rarely occurring anaphylactoid reactions. The purpose of this review is to describe the general and organ-specific properties of ferumoxytol, as well as the advantages and potential pitfalls associated with its use in magnetic resonance imaging. To more fully demonstrate the applications of ferumoxytol throughout the body, an imaging atlas was created and is available online as supplementary material.


Assuntos
Meios de Contraste/administração & dosagem , Óxido Ferroso-Férrico/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Animais , Atlas como Assunto , Pré-Escolar , Meios de Contraste/efeitos adversos , Meios de Contraste/farmacocinética , Feminino , Óxido Ferroso-Férrico/efeitos adversos , Óxido Ferroso-Férrico/farmacocinética , Hematínicos/administração & dosagem , Humanos , Rim/fisiopatologia , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Eliminação Renal , Insuficiência Renal Crônica/fisiopatologia , Reprodutibilidade dos Testes
3.
Restor Neurol Neurosci ; 34(2): 165-75, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26890094

RESUMO

PURPOSE: Clinical effects of repetitive transcranial magnetic stimulation (rTMS) in chronic tinnitus are moderate. More precise coil localisation strategies, innovative stimulation protocols, and identification of predictors for treatment response were proposed as promising attempts to enhance treatment efficacy. In this pilot study we investigated neuronavigated continuous theta burst TMS (cTBS). METHODS: Twenty-three patients received neuronavigated cTBS over the left primary auditory cortex in a randomized sham-controlled trial (verum = 12; sham = 11). Treatment response was evaluated with tinnitus questionnaires and numeric rating scales. Immediate change in numeric rating scales during the first session was used as predictor for treatment response. RESULTS: Tinnitus was significantly reduced after treatment, but there were no superior effects between verum vs. sham treatment. Immediate change in the first treatment session predicted the response to treatment only in the verum group. CONCLUSIONS: In our study, verum cTBS was not superior to sham which highlights the persistent need for improving non-invasive brain stimulation techniques for the treatment of tinnitus. Future research should focus on the transfer of positive single session effects to daily treatment trials.


Assuntos
Córtex Auditivo/fisiologia , Lateralidade Funcional/fisiologia , Zumbido/terapia , Estimulação Magnética Transcraniana/métodos , Estimulação Acústica , Adulto , Córtex Auditivo/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Psicoacústica , Inquéritos e Questionários , Zumbido/diagnóstico por imagem
4.
Neural Plast ; 2014: 894203, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25478237

RESUMO

OBJECTIVE: Several neuroscience tools showed the involvement of auditory cortex in chronic tinnitus. In this proof-of-principle study we probed the capability of functional near-infrared spectroscopy (fNIRS) for the measurement of brain oxygenation in auditory cortex in dependence from chronic tinnitus and from intervention with transcranial magnetic stimulation. METHODS: Twenty-three patients received continuous theta burst stimulation over the left primary auditory cortex in a randomized sham-controlled neuronavigated trial (verum = 12; placebo = 11). Before and after treatment, sound-evoked brain oxygenation in temporal areas was measured with fNIRS. Brain oxygenation was measured once in healthy controls (n = 12). RESULTS: Sound-evoked activity in right temporal areas was increased in the patients in contrast to healthy controls. Left-sided temporal activity under the stimulated area changed over the course of the trial; high baseline oxygenation was reduced and vice versa. CONCLUSIONS: By demonstrating that rTMS interacts with auditory evoked brain activity, our results confirm earlier electrophysiological findings and indicate the sensitivity of fNIRS for detecting rTMS induced changes in brain activity. Moreover, our findings of trait- and state-related oxygenation changes indicate the potential of fNIRS for the investigation of tinnitus pathophysiology and treatment response.


Assuntos
Córtex Auditivo/fisiopatologia , Espectroscopia de Luz Próxima ao Infravermelho , Zumbido/fisiopatologia , Estimulação Magnética Transcraniana , Estimulação Acústica , Adulto , Doença Crônica , Potenciais Evocados Auditivos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
J Cereb Blood Flow Metab ; 29(4): 853-60, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19142191

RESUMO

The vascular effects of antiangiogenic treatment may pose problems for evaluating brain tumor response based on contrast-enhanced magnetic resonance imaging (MRI). We used serial dynamic contrast-enhanced MRI at 12 T to assess vascular responses to antiangiogenic versus steroid therapy. Athymic rats with intracerebral U87MG human glioma (n=17) underwent susceptibility-weighted perfusion MRI with ferumoxytol, a solely intravascular ultrasmall superparamagnetic iron oxide (USPIO) nanoparticle, followed by T1-weighted dynamic gadodiamide-enhanced MRI to measure vascular permeability. Rats were imaged before and after 24, 48, and 72 h of treatment with the antiangiogenic agent bevacizumab or the corticosteroid dexamethasone. Contrast agent extravasation was seen rapidly after gadodiamide, but not with ferumoxytol administration. Bevacizumab significantly decreased the blood volume and decreased permeability in tumors as determined by increased time-to-peak enhancement. A single dose of 45 mg/kg bevacizumab resulted in changes analogous to dexamethasone given in an extremely high dose (12 mg/kg per day), and was significantly more effective than dexamethasone at 2 mg/kg per day. We conclude that dynamic perfusion MRI measurements with ferumoxytol USPIO to assess cerebral blood volume, along with dynamic gadodiamide-enhanced MR to assess vascular permeability, hold promise in more accurately detecting therapeutic responses to antiangiogenic therapy.


Assuntos
Corticosteroides/uso terapêutico , Inibidores da Angiogênese/uso terapêutico , Compostos Férricos , Glioma/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Nanopartículas , Animais , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Humanizados , Bevacizumab , Permeabilidade Capilar , Circulação Cerebrovascular/efeitos dos fármacos , Dexametasona/uso terapêutico , Modelos Animais de Doenças , Monitoramento de Medicamentos/métodos , Gadolínio DTPA , Glioma/diagnóstico , Humanos , Cinética , Ratos
6.
Kidney Int ; 75(5): 465-74, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18843256

RESUMO

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis (NSF) is a recently recognized severe complication associated with GBCAs. It affects primarily patients with renal disease, such as stage 4 or 5 chronic kidney disease (CKD; glomerular filtration rate <30 ml/min per 1.73 m(2)), acute kidney injury, or kidney and liver transplant recipients with kidney dysfunction. Contrast-enhanced MRI and computed tomography (CT) scans provide important clinical information and influence patient management. An alternative contrast agent is needed to obtain adequate imaging results while avoiding the risk of NSF in this vulnerable patient group. One potential alternative is ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles, which provide enhancement characteristics similar to GBCAs. We review our experience in approximately 150 patients on the potential benefits of the USPIOs ferumoxtran-10 and ferumoxytol. We focus on central nervous system (CNS) MRI but also review imaging of other vascular beds. Safety studies, including USPIO administration (ferumoxytol) as iron supplement therapy in CKD patients on and not on dialysis, suggest that decreased kidney function does not alter the safety profile. We conclude that for both CNS MR imaging and MR angiography, USPIO agents like ferumoxytol are a viable option for patients at risk for NSF.


Assuntos
Meios de Contraste/efeitos adversos , Óxido Ferroso-Férrico , Ferro , Nefropatias/complicações , Imageamento por Ressonância Magnética/métodos , Dermopatia Fibrosante Nefrogênica/prevenção & controle , Óxidos , Sistema Nervoso Central/patologia , Doença Crônica , Dextranos , Óxido Ferroso-Férrico/toxicidade , Gadolínio/toxicidade , Taxa de Filtração Glomerular , Humanos , Ferro/toxicidade , Nefropatias/diagnóstico , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética/efeitos adversos , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Nanopartículas/toxicidade , Dermopatia Fibrosante Nefrogênica/induzido quimicamente , Óxidos/toxicidade , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA