Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
JACC Clin Electrophysiol ; 9(3): 425-441, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36990601

RESUMO

Junctional tachycardia (JT) is typically considered to have an automatic mechanism originating from the distal atrioventricular node. When there is 1:1 retrograde conduction via the fast pathway, JT would resemble the typical form of atrioventricular nodal re-entrant tachycardia (AVNRT). Atrial pacing maneuvers have been proposed to exclude AVNRT and suggest a diagnosis of JT. However, after excluding AVNRT, one should consider the possibility of an infra-atrial narrow QRS re-entrant tachycardia, which can exhibit features that resemble AVNRT as well as JT. Pacing maneuvers and mapping techniques should be performed to assess for infra-atrial re-entrant tachycardia before concluding that JT is the mechanism of a narrow QRS tachycardia. Distinguishing JT from typical AVNRT or infra-atrial re-entrant tachycardia has notable implications regarding the approach to ablation of the tachycardia. Ultimately, a contemporary review of the evidence on JT raises some questions as to the mechanism and source of what has traditionally been considered JT.


Assuntos
Fibrilação Atrial , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ectópica de Junção , Taquicardia Supraventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ectópica de Junção/diagnóstico , Nó Atrioventricular , Fascículo Atrioventricular , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
4.
J Cardiovasc Electrophysiol ; 31(2): 544-546, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31908076

RESUMO

This case illustrates that the condition of atrial fibrillation (AF) may harbor site(s) of regular rotational activity, reentry may be an underlying mechanism, high periodicity and wavebreak through areas of the scar may generate fibrillatory conduction, and disintegration of the "rotor" may not abolish AF.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Humanos , Valor Preditivo dos Testes , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 30(9): 1569-1577, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31187543

RESUMO

INTRODUCTION: Atrioventricular nodal re-entry tachycardia (AVNRT) is the most common, regular narrow-complex tachycardia. The established treatment is catheter ablation of the AV nodal slow pathway (SP). However, in a select group of patients with long PR intervals in sinus rhythm, SP ablation can lead to AV block due to the absence of robust anterograde conduction through the fast pathway (FP). This report aims to demonstrate that AV nodal FP ablation is a reasonable approach in patients with AVNRT and poor or absent anterograde FP conduction. METHODS AND RESULTS: Standard electrophysiology study techniques were used in the electrophysiology laboratory. Catheter ablations were performed using radiofrequency energy. Mapping of intracardiac activation was performed with electroanatomical mapping systems. Outcomes were assessed acutely during the procedure and during routine clinical follow-up. Six patients with first-degree AV block and recurrent AVNRT who underwent ablation of their tachycardia at our institution are presented. One patient underwent ablation of AV nodal SP resulting in high-degree AV block necessitating pacemaker implantation. The remaining five patients underwent ablation of the AV nodal FP guided by electroanatomical mapping of the earliest atrial activation in tachycardia. These five had successful treatment of the tachycardia with preservation of anterograde AV nodal conduction. Mapping and ablation approach to eliminate retrograde FP conduction are described. CONCLUSION: In select patients with AVNRT and poor anterograde FP conduction, retrograde FP ablation is reasonable and is less likely to result in AV block and pacemaker dependency.


Assuntos
Nó Atrioventricular/cirurgia , Ablação por Cateter , Frequência Cardíaca , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Nó Atrioventricular/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
6.
Europace ; 21(8): 1143-1144, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31075787

RESUMO

Ventricular arrhythmias are an important cause of morbidity and mortality and come in a variety of forms, from single premature ventricular complexes to sustained ventricular tachycardia and fibrillation. Rapid developments have taken place over the past decade in our understanding of these arrhythmias and in our ability to diagnose and treat them. The field of catheter ablation has progressed with the development of new methods and tools, and with the publication of large clinical trials. Therefore, global cardiac electrophysiology professional societies undertook to outline recommendations and best practices for these procedures in a document that will update and replace the 2009 EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias. An expert writing group, after reviewing and discussing the literature, including a systematic review and meta-analysis published in conjunction with this document, and drawing on their own experience, drafted and voted on recommendations and summarized current knowledge and practice in the field. Each recommendation is presented in knowledge byte format and is accompanied by supportive text and references. Further sections provide a practical synopsis of the various techniques and of the specific ventricular arrhythmia sites and substrates encountered in the electrophysiology lab. The purpose of this document is to help electrophysiologists around the world to appropriately select patients for catheter ablation, to perform procedures in a safe and efficacious manner, and to provide follow-up and adjunctive care in order to obtain the best possible outcomes for patients with ventricular arrhythmias.


Assuntos
Eletrofisiologia Cardíaca , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Eletrofisiologia Cardíaca/organização & administração , Eletrofisiologia Cardíaca/normas , Eletrofisiologia Cardíaca/tendências , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ablação por Cateter/normas , Consenso , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Cardiopatias/classificação , Cardiopatias/complicações , Humanos , Cooperação Internacional , Melhoria de Qualidade/organização & administração , Sociedades Médicas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
7.
Europace ; 20(4): 622-628, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016878

RESUMO

Aims: Benefits of automatic remote home monitoring (HM) among implantable cardioverter defibrillator (ICD) patients may require high transmission frequency. However, transmission reliability and effects on battery longevity remain uncertain. We hypothesized that HM would have high transmission success permitting punctual guideline based follow-up, and improve battery longevity. This was tested in the prospective randomized TRUST trial. Methods and results: Implantable cardioverter defibrillator patients were randomized post-implant 2:1 to HM (n = 908) (transmit daily) or to Conventional in-person monitoring [conventional management (CM), n = 431 (HM disabled)]. In both groups, five evaluations were scheduled every 3 months for 15 months. Home Monitoring technology performance was assessed by transmissions received vs. total possible, and number of scheduled HM checks failing because of missed transmissions. Battery longevity was compared in HM vs. CM at 15 months, and again in HM 3 years post-implant using continuously transmitted data. Transmission success per patient was 91% (median follow-up of 434 days). Overall, daily HM transmissions were received in 315 795 of a potential 363 450 days (87%). Only 55/3759 (1.46%) of unsuccessful scheduled evaluations in HM were attributed to transmission loss. Shock frequency and pacing percentage were similar in HM vs. CM. Fifteen month battery longevity was 12% greater in HM (93.2 ± 8.8% vs. 83.5 ± 6.0% CM, P < 0.001). In extended follow-up of HM patients, estimated battery longevity was 50.9 ± 9.1% (median 52%) at 36 months. Conclusion: Automatic remote HM demonstrated robust transmission reliability. Daily transmission load may be sustained without reducing battery longevity. Home Monitoring conserves battery longevity and tracks long term device performance. Clinical trial registration: ClinicalTrials.gov; NCT00336284.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Fontes de Energia Elétrica , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Telemedicina/instrumentação , Telemetria/instrumentação , Automação , Cardioversão Elétrica/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
8.
Artigo em Inglês | MEDLINE | ID: mdl-29030379

RESUMO

BACKGROUND: Right ventricular pacing (RVP) increases risk of atrial fibrillation in patients with implantable cardioverter-defibrillators (ICDs), but ventricular proarrhythmia is less clear. We analyzed a large remote monitoring database to assess this question. METHODS AND RESULTS: Patients with single- or dual-chamber ICDs, engaged in remote monitoring for at least 6 months and with unchanged tachycardia programming, were included. %RVP was derived for each weekly transmission. ICD electrograms preceding the first shock were adjudicated. Among 425 625 transmissions received from 8435 patients, 389 appropriate shocks occurred over a mean follow-up of 15.0±8.8 months. In a time-dependent Cox proportional hazards model, transmissions with 80% to 98% RVP were associated with a hazard ratio of 1.56 for an appropriate shock in the subsequent week compared with <1% RVP (95% CI, 1.01-2.41; P=0.04). By contrast, ≥98% RVP trended toward a lower risk of an appropriate shock (hazard ratio, 0.61; 95% CI, 0.33-1.12; P=0.108). Lifetime cumulative %RVP was closely correlated with weekly %RVP (R2=0.907) and was similarly associated with increased risk of appropriate shocks at 80% to 98% RVP (hazard ratio, 1.57; 95% CI, 1.01-2.44; P=0.046) but not at ≥98% RVP (hazard ratio, 0.49; 95% CI, 0.24-1.01; P=0.052). These results were driven by dual-chamber devices, but unaffected by PVC counts or programming. Male sex and age were also associated with appropriate ICD shocks. CONCLUSIONS: Increasing frequency of RVP is associated with a progressively increased risk of appropriate ICD shocks until ≥98% RVP. RVP may have ventricular proarrhythmia because of competition of paced and intrinsic rhythm in ICD patients.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Função Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Bases de Dados Factuais , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Falha de Prótese , Tecnologia de Sensoriamento Remoto , Fatores de Risco , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
9.
Card Electrophysiol Clin ; 7(1): 125-34, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25784029

RESUMO

Causes for diverse effects of cardiac resynchronization therapy (CRT) are poorly understood. Because CRT is an electrical therapy, it may be best understood by detailed characterization of electrical substrate and its interaction with pacing. Electrocardiogram (ECG) features affect CRT outcomes. However, the surface ECG reports rudimentary electrical data. In contrast, noninvasive electrocardiographic imaging provides high-resolution single-beat ventricular mapping. Several complex characteristics of electrical substrate, not decipherable from the 12-lead ECG, are linked to CRT effect. CRT response may be improved by candidate selection and left ventricular lead placement directed by more precise electrical evaluation, on an individual patient basis.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Insuficiência Cardíaca/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Imageamento Tridimensional , Função Ventricular
11.
Am J Cardiol ; 103(11): 1578-85, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-19463519

RESUMO

Left ventricular activation delay (LVAT) >100 ms may determine response to cardiac resynchronization therapy, but its prevalence and relation to QRS configuration are unknown. QRS duration and LVAT in control subjects (n = 30) were compared with those in patients with heart failure (HF; LV ejection fraction 23 +/- 8%, n = 120) with a QRS duration <120 ms (NQRS(HF), n = 35) or > or = 120 ms (left bundle branch block [LBBB(HF)], n = 54; right bundle branch block [RBBB(HF)], n = 31). LVAT was estimated by interval from QRS onset to basal inferolateral LV depolarization. In controls, QRS duration was 82 +/- 13 ms and LVAT was 55 +/- 18 ms. LVAT was always <100 ms. In patients with NQRS(HF), QRS duration (104 +/- 10 ms) and LVAT (82 +/- 22 ms) were prolonged versus controls (p <0.001). LVAT exceeded 100 ms in 8 of 35 patients. In patients with LBBB(HF), QRS duration (161 +/- 29 ms) and LVAT (136 +/- 33 ms) were prolonged compared with controls and patients with NQRS(HF) (p <0.001). LVAT exceeded 100 ms in 47 of 54 patients. In patients with RBBB(HF), QRS duration did not differ from that in patients with LBBB(HF), but LVAT (100 +/- 24 ms) was shorter (p <0.001). In 17 of 31 patients with RBBB(HF) LVAT was <100 ms (82 +/- 12), similar to those with NQRS(HF) (p = NS), indicating no LV conduction delay. However, in 7 of 31, LVAT (135 +/- 13 ms) was similar to that in patients with LBBB(HF) (p = NS). LVAT correlation with QRS duration varied (control p = 0.004, NQRS(HF) p = 0.15, RBBB(HF) p = 0.01, LBBB(HF) p <0.001). In conclusion, LV conduction delays in patients with HF varied with QRS configuration and duration, exceeding 100 ms in only 23% of patients with narrow QRS configuration and 45% with RBBB(HF) compared with 87% with LBBB(HF). Fewer than 25% of patients with RBBB(HF) demonstrated delays equivalent to those in patients with LBBB(HF.) These variations may affect efficacy to cardiac resynchronization therapy.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
12.
J Cardiovasc Electrophysiol ; 18(4): 349-55, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17394449

RESUMO

INTRODUCTION: The radiofrequency MAZE is becoming a common adjunct to cardiac surgery in patients with atrial fibrillation. While a variety of postoperative arrhythmias have been described following the original Cox-MAZE III procedure, the electrophysiological characteristics and surgical substrate of post-radiofrequency MAZE flutter have not been correlated. We sought to determine the location, ECG patterns, and electrophysiological characteristics of post-radiofrequency MAZE atrial flutter. METHODS: Nine consecutive patients with post-radiofrequency MAZE flutter presented for catheter ablation 9 +/- 10 months after surgery. RESULTS: Only one patient (11%) had an ECG appearance consistent with typical isthmus-dependent right atrial (RA) flutter. However, on electrophysiological study, 3/9 patients (33%) had typical right counter-clockwise flutter entrained from the cavo-tricuspid isthmus, despite description of surgical isthmus ablation. Six patients (67%) had left atrial (LA) circuits. These involved the mitral annulus in 5/6 cases (83%) despite description of surgical mitral isthmus ablation in the majority (60%). LA flutters had a shorter cycle length compared with RA flutters (253 +/- 39 msec and 332 +/- 63 msec respectively, P < 0.05). After a mean of 8 +/- 4 months following ablation, 8/9 patients (89%) were in sinus rhythm. CONCLUSION: Up to one-third of post-radiofrequency MAZE circuits are typical isthmus-dependent RA flutters, despite a highly atypical surface ECG morphology. Therefore, diagnostic electrophysiological studies should commence with entrainment at the cavo-tricuspid isthmus in order to exclude typical flutter, regardless of the surface ECG appearance. Incomplete surgical lesions at the mitral and cavo-tricuspid isthmus likely predispose to the development of post-radiofrequency MAZE flutter.


Assuntos
Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Ablação por Cateter/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal , Terapia Combinada , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 28(8): 808-18, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16105009

RESUMO

BACKGROUND: We describe a new cavotricuspid isthmus (CTI) circuit. METHODS: This study includes 8 patients referred for atrial flutter (AFL) ablation whose tachycardia circuit was confined to the septal CTI and the os of the coronary sinus (CS(OS)) region. Entrainment mapping was performed within the CTI, CS(OS), and other right atrial annular sites (tricuspid annulus (TA)). Electroanatomic mapping was available in 2 patients. RESULTS: Sustained AFL occurred in all patients with mean tachycardia cycle length (TCL) of 318 +/- 54 (276 - 420) ms. During tachycardia, fractionated or double potentials were recorded at either the septal CTI and/or the region of CS(OS) in all, and concealed entrainment with post-pacing interval (PPI)--TCL < or = 25 ms occurred in this area; but manifest entrainment with PPI > TCL was demonstrated from the anteroinferior CTI and other annular sites in 7/8 patients. In one, tachycardia continued with conduction block at the anteroinferior CTI during ablation. Up to three different right atrial activation patterns (identical TCL) were observed. The tachycardia showed a counterclockwise (CCW) pattern in 6, a clockwise pattern in 2, and simultaneous activation of both low lateral right atrium and septum in 5. Electroanatomic mapping was available in 2, showing an early area arising from the septal CTI in 1, and a CCW activation sequence along the TA in another. Radiofrequency application to the septal CTI terminated tachycardia in 4, and tachycardia no longer inducible in all. CONCLUSIONS: We describe a tachycardia circuit confined to the septal CTI/CS(OS) region, and hypothesize that this circuit involves slow conduction within the CTI and around the CS(OS), which acts as a central obstacle.


Assuntos
Flutter Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Valva Tricúspide/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
15.
Heart Rhythm ; 1(1): 82-7, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15851123

RESUMO

A 74-year-old man with a structurally normal heart presented with typical atrial flutter, after treatment of atrial fibrillation with propafenone. Catheterization and computed tomographic imaging revealed absence of the inferior vena caval segment that normally traverses the liver to enter the right atrium. Abdominal venous return occurred via the hemi-azygous vein, draining into the superior vena cava. Hepatic veins inserted postero-inferiorly into the right atrium. Pacing atrial myocardium between the hepatic veins and the tricuspid valve resulted in concealed entrainment. Radiofrequency catheter ablation directed (via a superior approach from the right internal jugular vein) to this extraordinary "isthmus" abolished atrial flutter. The implications of this congenital abnormality on posterior barriers maintaining the atrial flutter circuit are discussed.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Veia Cava Inferior/anormalidades , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino , Propafenona/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/complicações , Síndrome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA