Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38475049

RESUMO

The clinical effects of a serious game with electromyography feedback (EMGs_SG) and physical therapy (PT) was investigated prospectively in children with unilateral spastic cerebral palsy (USCP). An additional aim was to better understand the influence of muscle shortening on function. Thirty children with USCP (age 7.6 ± 2.1 years) received four weeks of EMGs_SG sessions 2×/week including repetitive, active alternating training of dorsi- and plantar flexors in a seated position. In addition, each child received usual PT treatment ≤ 2×/week, involving plantar flexor stretching and command strengthening on dorsi- and plantar flexors. Five-Step Assessment parameters, including preferred gait velocity (normalized by height); plantar flexor extensibility (XV1); angle of catch (XV3); maximal active ankle dorsiflexion (XA); and derived coefficients of shortening, spasticity, and weakness for both soleus and gastrosoleus complex (GSC) were compared pre and post treatment (t-tests). Correlations were explored between the various coefficients and gait velocities at baseline. After four weeks of EMGs_SG + PT, there was an increase in normalized gait velocity from 0.72 ± 0.13 to 0.77 ± 0.13 m/s (p = 0.025, d = 0.43), a decrease in coefficients of shortening (soleus, 0.10 ± 0.07 pre vs. 0.07 ± 0.08 post, p = 0.004, d = 0.57; GSC 0.16 ± 0.08 vs. 0.13 ± 0.08, p = 0.003, d = 0.58), spasticity (soleus 0.14 ± 0.06 vs. 0.12 ± 0.07, p = 0.02, d = 0.46), and weakness (soleus 0.14 ± 0.07 vs. 0.11 ± 0.07, p = 0.005, d = 0.55). At baseline, normalized gait velocity correlated with the coefficient of GSC shortening (R = -0.43, p = 0.02). Four weeks of EMGs_SG and PT were associated with improved gait velocity and decreased plantar flexor shortening. A randomized controlled trial comparing EMGs_SG and conventional PT is needed.


Assuntos
Paralisia Cerebral , Neurorretroalimentação , Criança , Humanos , Pré-Escolar , Estudos Prospectivos , Músculo Esquelético , Espasticidade Muscular , Modalidades de Fisioterapia , Marcha/fisiologia , Eletromiografia
2.
Sensors (Basel) ; 20(6)2020 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-32192073

RESUMO

The transcutaneous stimulation of lower limb muscles during indoor rowing (FES Rowing) has led to a new sport and recreation and significantly increased health benefits in paraplegia. Stimulation is often delivered to quadriceps and hamstrings; this muscle selection seems based on intuition and not biomechanics and is likely suboptimal. Here, we sample surface EMGs from 20 elite rowers to assess which, when, and how muscles are activated during indoor rowing. From EMG amplitude we specifically quantified the onset of activation and silencing, the duration of activity and how similarly soleus, gastrocnemius medialis, tibialis anterior, rectus femoris, vastus lateralis and medialis, semitendinosus, and biceps femoris muscles were activated between limbs. Current results revealed that the eight muscles tested were recruited during rowing, at different instants and for different durations. Rectus and biceps femoris were respectively active for the longest and briefest periods. Tibialis anterior was the only muscle recruited within the recovery phase. No side differences in the timing of muscle activity were observed. Regression analysis further revealed similar, bilateral modulation of activity. The relevance of these results in determining which muscles to target during FES Rowing is discussed. Here, we suggest a new strategy based on the stimulation of vasti and soleus during drive and of tibialis anterior during recovery.


Assuntos
Terapia por Estimulação Elétrica/métodos , Exercício Físico/fisiologia , Extremidade Inferior/fisiologia , Músculo Esquelético/fisiologia , Esportes Aquáticos/fisiologia , Adolescente , Adulto , Fenômenos Biomecânicos/fisiologia , Terapia por Estimulação Elétrica/normas , Eletromiografia/métodos , Eletromiografia/normas , Feminino , Humanos , Masculino , Paraplegia/fisiopatologia , Paraplegia/terapia , Fatores de Tempo , Adulto Jovem
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 3815-3818, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946705

RESUMO

The use of electrical stimulation to elicit single twitches and tetanic contractions of skeletal muscles has increased markedly in the last years, with applications ranging from basic physiology to clinical settings. Addressing all possible needs required by different applications with an electrical stimulator is challenging as it requires the device to be highly flexible in terms of stimulation configurations (number of channels and electrode location), and possibility to control the stimulation patterns (timing and stimulation profiles). This paper describes a new wireless, modular, and programmable electrical stimulator integrating the possibility to acquire and use biomechanical signals to trigger the stimulation output. A closed-loop FES Cycling setup has been presented to show a possible application of the system.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Músculo Esquelético/fisiologia , Tecnologia sem Fio , Desenho de Equipamento , Humanos
4.
J Neurophysiol ; 120(5): 2603-2613, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30156959

RESUMO

The purpose of our study was to compare the influence of five types of electrical nerve stimulation delivered through electrodes placed over the right biceps brachii on motor unit activity in the left biceps brachii during an ongoing steady isometric contraction. The electrical stimulation protocols comprised different combinations of pulse duration (0.2 and 1.0 ms), stimulus frequency (50 and 90 Hz), and stimulus current (greater or less than motor threshold). The electrical nerve stimulation protocols were applied over the muscle of the right elbow flexors of 13 participants (26 ± 3 yr) while they performed voluntary contractions with the left elbow flexors to match a target force set at 10% of maximum. All five types of electrical nerve stimulation increased the absolute amplitude of the electromyographic (EMG) signal recorded from the left biceps brachii with high-density electrodes. Moreover, one stimulation condition (1 ms, 90 Hz) had a consistent influence on the centroid location of the EMG amplitude distribution and the average force exerted by the left elbow flexors. Another stimulation condition (0.2 ms, 90 Hz) reduced the coefficient of variation for force during the voluntary contraction, and both low-frequency conditions (50 Hz) increased the duration of the mean interspike interval of motor unit action potentials after the stimulation had ended. The findings indicate that the contralateral effects of electrical nerve stimulation on the motor neuron pool innervating the homologous muscle can be influenced by both stimulus pulse duration and stimulus frequency. NEW & NOTEWORTHY Different types of electrical nerve stimulation delivered through electrodes placed over the right biceps brachii modulated the ongoing motor unit activity in the left biceps brachii. Although the effects varied with stimulus pulse duration, frequency, and current, all five types of electrical nerve stimulation increased the amplitude of the electromyographic activity in the left biceps brachii. Moreover, most of the effects in the left arm occurred after the electrical nerve stimulation of the right arm had been terminated.


Assuntos
Contração Isométrica , Músculo Esquelético/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Potencial Evocado Motor , Feminino , Humanos , Masculino , Músculo Esquelético/inervação , Recrutamento Neurofisiológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA