J Cardiovasc Electrophysiol ; 24(4): 437-41, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23210803

RESUMO

INTRODUCTION: Defibrillation threshold (DFT) testing has been performed to prove functionality of the implantable cardioverter defibrillator (ICD). Over the past years it has become increasingly controversial because of possible morbidity and mortality. The goal of this study was to determine unsuccessful shock testing and report strategies used to overcome these problems. METHODS AND RESULTS: A total of 314 patients with a de novo implantation of an ICD and 127 patients receiving a generator exchange were identified retrospectively. All patients underwent defibrillation threshold testing after induction of VF using a low-energy T-wave shock during the intervention, 2 shock tests after de novo implantations, 1 after generator change. A safety margin of 10 J or more was requested. Seven (2.3%) patients in the de novo group and 2 patients (1.4%) in the generator exchange group could not be defibrillated using the standard approach. All of those patients had either chronic amiodarone therapy, secondary prevention or a cardiac resynchronization therapy device (CRT). In univariate analysis, amiodarone therapy, dilated cardiomyopathy, and lower ejection fraction were predictors of failure. CONCLUSION: Our study's results as well as a review of the current literature favor shock testing, especially in patients with specific risk factors as mentioned above.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/terapia , Fibrilação Ventricular/prevenção & controle , Idoso , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Dispositivos de Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/complicações , Remoção de Dispositivo , Segurança de Equipamentos , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA