RESUMO
BACKGROUND: Medical devices must be safe and functioning states the law. Treatments with medical devices need not be efficacious to be allowed. We investigated special requirements and problems arising from the law. METHODS: The market for medical devices is contrasted with that for drugs. The requirements of relevant laws are discussed. Finally, published clinical studies on anal incontinence are analysed with respect to their methodological quality. RESULTS: Clinical trials of medical devices for treat-ing anal incontinence are of poor methodological quality thus preventing evaluation of the devices' utility. CONCLUSION: Large, high quality clinical studies of the efficacy of medical devices for treating anal incontinence are urgently needed. Only such studies enable health technology assessment and comprehensible decisions on reimbursement by health insurance.
Assuntos
Aprovação de Equipamentos/legislação & jurisprudência , Incontinência Fecal/terapia , Ensaios Clínicos Controlados Aleatórios como Assunto/legislação & jurisprudência , Ensaios Clínicos Controlados Aleatórios como Assunto/normas , Biorretroalimentação Psicológica/instrumentação , Coleta de Dados/legislação & jurisprudência , Terapia por Estimulação Elétrica/instrumentação , Desenho de Equipamento , Falha de Equipamento , Segurança de Equipamentos , Medicina Baseada em Evidências/normas , Alemanha , Fidelidade a Diretrizes/legislação & jurisprudência , Humanos , Programas Nacionais de Saúde/legislação & jurisprudência , Controle de Qualidade , Resultado do TratamentoRESUMO
STUDY OBJECTIVES: Animal studies (guinea pig, cat, chinchilla) have shown that activity of the medial olivocochlear efferents can exert noise-protective effects on the cochlea. It is not yet known whether such effects are also existent in humans. Olivocochlear activity can be estimated indirectly by contralateral suppression (CS) of otoacoustic emissions (OAE). MATERIAL AND METHODS: We measured Input/Output functions of distortion products of OAE (DPOAE), with and without contralateral acoustic stimulation by white noise, in 94 normal hearing young male subjects. Seven stimuli with L2 between 20 and 60 dB SPL and L1 = 39 dB + 0.4 L2 ("scissor paradigm") were used at f2 = 2, 3, 4, 5, and 6 kHz. The measurement was repeated 2 weeks later. In 83 subjects of the same group, pure tone audiometry was registered before and 6 minutes after shooting exercises to evaluate individual susceptibility to develop a temporary threshold shift (TTS). RESULTS: Test-retest repeatability of CS was generally good. CS averaged 0.98 dB SPL (SD 1.19 dB, median 0.56 dB). As expected, CS was greatest at low stimulus levels (median 1.06 dB at L2 = 20 dB, as compared with 0.33 dB at L2 = 60 dB). The smallest average CS was found at 4 kHz, and the greatest CS appeared at 2 kHz. A TTS occurred in 7 of 83 (8.5%) subjects. Statistical analysis did not reveal any correlation between the amount of CS and individual TTS susceptibility. CONCLUSIONS AND OUTLOOK: 1) Measurement of CS of DPOAE using an extensive measurement paradigm revealed good test-retest repeatability, confirming the reliability of this audiologic tool. 2) CS of DPOAE does not predict individual susceptibility to mild TTS induced by impulse noise in humans. Possible explanations for the missing association are discussed. Future perspectives include longitudinal studies to further elucidate the association between medial olivocochlear bundle-activity and permanent threshold shift in humans. The goal is to develop a diagnostic tool for the prediction of individual noise vulnerability in humans, thereby preventing noise-induced hearing loss.
Assuntos
Limiar Auditivo/fisiologia , Cóclea/fisiologia , Audição/fisiologia , Testes de Impedância Acústica/métodos , Estimulação Acústica , Adolescente , Adulto , Humanos , Masculino , RuídoAssuntos
Sulfato de Bário , Colo/patologia , Neoplasias Colorretais/diagnóstico , Meios de Contraste , Gadolínio DTPA , Aumento da Imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Pólipos Adenomatosos/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Pólipos do Colo/diagnóstico , Colonoscopia , Doença Diverticular do Colo/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: To identify a relation between loss of muscle strength and vitamin D deficiency in ambulatory elderly persons not receiving vitamin D supplementation. DESIGN: Cross-sectional study. SETTING: All measurements were taken at the Department of Geriatrics, University Hospital, Basel, Switzerland. SUBJECTS: Three hundred nineteen patients (103 women, 216 men) selected by random sampling from participants in an ongoing interdisciplinary study on aging (mean age for women, 74.2 yrs; for men, 76.7 yrs). OUTCOME MEASURES: Leg extension power (LEP) and body mass index (BMI); serum values of 25-hydroxyvitamin D [calcidiol, 25(OH)D], 1,25-hydroxyvitamin D [calcitriol, 1,25(OH)2D], and intact parathyroid hormone (iPHT). RESULTS: Twelve percent of women and 18% of men had 25(OH)D values below the normal range (<12 ng/mL). Muscle strength was lower in older subjects (female: r = -.35; p = .0005/male: r = -.48; p < .0001) and was lower in women than in men (p < .0001). In men both 25(OH)D and 1,25(OH)2D was significantly correlated with LEP (r = 0.24; p = .0004/r = .14; p = .045). In women, only 1,25(OH)2D was significantly correlated with LEP (r = 0.22; p = .034). In an ANCOVA including all participants and explaining LEP by sex, age, BMI, 1,25(OH)2D, 25(OH)D, and iPTH, all factors showed significant effects except 25(OH)D and iPTH (r2 = .41). CONCLUSION: Muscle strength declined with age in ambulatory elderly people and showed modest, but significant, positive correlation with 1,25(OH)2 vitamin D in both sexes and with 25(OH)D in male subjects. Therefore vitamin D deficiency appears to contribute to the age-related loss of muscle strength, which might be more pronounced in institutionalized elderly people with a high prevalence of vitamin D deficiency.