Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 9(1): 1-16, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36697187

RESUMO

BACKGROUND: Accurate annotation of local activation time is crucial in the functional assessment of ventricular tachycardia (VT) substrate. A major limitation of modern mapping systems is the standard prospective window of interest (sWOI) is limited to 490 to 500 milliseconds, preventing annotation of very late potentials (LPs). A novel retrospective window of interest (rWOI), which allows annotation of all diastolic potentials, was used to assess the functional VT substrate. OBJECTIVES: This study sought to investigate the utility of a novel rWOI, which allows accurate visualization and annotation of all LPs during VT substrate mapping. METHODS: Patients with high-density VT substrate maps and a defined isthmus were included. All electrograms were manually annotated to latest activation using a novel rWOI. Reannotated substrate maps were correlated to critical sites, with areas of late activation examined. Propagation patterns were examined to assess the functional aspects of the VT substrate. RESULTS: Forty-eight cases were identified with 1,820 ± 826 points per map. Using the novel rWOI, 31 maps (65%) demonstrated LPs beyond the sWOI limit. Two distinct patterns of channel activation were seen during substrate mapping: 1) functional block with unidirectional conduction into the channel (76%); and 2) wave front collision within the channel (24%). In addition, a novel marker termed the zone of early and late crowding was studied in the rWOI substrate maps and found to have a higher positive predictive value (85%) than traditional deceleration zones (69%) for detecting critical sites of re-entry. CONCLUSIONS: The standard WOI of contemporary mapping systems is arbitrarily limited and results in important very late potentials being excluded from annotation. Future versions of electroanatomical mapping systems should provide longer WOIs for accurate local activation time annotation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Ventrículos do Coração , Estudos Retrospectivos , Estudos Prospectivos , Lipopolissacarídeos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas
2.
J Cardiovasc Electrophysiol ; 31(2): 474-484, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31930658

RESUMO

INTRODUCTION: Minimal data exist on the Advisor HD Grid (HDG) catheter and the Precision electroanatomic mapping (EAM) system for ventricular arrhythmia (VA) procedures. Using the HDG catheter, the EAM uses the high-density (HD) wave mapping and best duplicate software to compare the maximum peak-to-peak bipolar voltages within a small zone independent of wavefront direction and catheter orientation. This study aimed to summarize the procedural experience for VAs using the HDG catheter. METHODS: Clinical and procedural characteristics of VA ablation procedures were retrospectively reviewed that used the HDG catheter and the Precision EAM over a 12-month period. RESULTS: A total of 22 patients, 18 with sustained ventricular tachycardia and 4 with premature ventricular contractions were included. Clinically indicated left and/or right ventricular (LV, RV, respectively), and aortic maps were created. LV substrate maps (n = 13) used a median 1700 points (interquartile range [IQR]25%-75% , 1427-2412) out of a median 18 573 (IQR25%-75% , 15 713-41 067) total points collected. RV substrate maps (n = 11) used a median 1435 points (IQR25%-75% , 1114-1871) out of a median 16 005 (IQR25%-75% , 11 063-21 405) total points collected. Total point utilization, used vs collected, was 9%. Mean mapping time was 43 ± 17 minutes (substrate, 34 ± 18 minutes; activation/pace mapping, 9 ± 13 minutes). Acute success was achieved in 56 (86%) and short-term success achieved in 16 patients (73%) at a median follow-up of 145 days (IQR25%-75% , 62-273 days). There were no procedural complications. CONCLUSION: HD wave mapping using the novel HDG catheter integrated with the Precision EAM is safe and feasible in VA procedures in the LV, RV, and aorta. Mapping times are consistent with other multielectrode mapping catheters.


Assuntos
Potenciais de Ação , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Frequência Cardíaca , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador , Software , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA