Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Echocardiography ; 38(8): 1430-1445, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34232534

RESUMO

Attempting a comprehensive examination of the fetal heart remains challenging for unexperienced operators as it emphasizes the acquisition and documentation of sequential cross-sectional and sagittal views and inevitably results in diminished detection rates of fetuses affected by congenital heart disease. The introduction of four-dimensional spatio-temporal image correlation (4D STIC) technology facilitated a volumetric approach for thorough cardiac anatomic evaluation by the acquisition of cardiac 4D datasets. By analyzing and re-arranging of numerous frames according to their temporal event within the heart cycle, STIC allows visualization of cardiac structures as an endless cine loop sequence of a complete single cardiac cycle in motion. However, post-analysis with manipulation and repeated slicing of the volume usually requires experience and in-depth anatomic knowledge, which limits the widespread application of this advanced technique in clinical care and unfortunately leads to the underestimation of its diagnostic value to date. Fetal intelligent navigation echocardiography (FINE), a novel method that automatically generates and displays nine standard fetal echocardiographic views in normal hearts, has shown to be able to overcome these limitations. Very recent data on the detection of congenital heart defects (CHDs) using the FINE method revealed a high sensitivity and specificity of 98% and 93%, respectively. In this two-part manuscript, we focused on the performance of FINE in delineating abnormal anatomy of typical right and left heart lesions and thereby emphasized the educational potential of this technology for more than just teaching purposes. We further discussed recent findings in a pathophysiological and/or functional context.


Assuntos
Ecocardiografia Quadridimensional , Cardiopatias Congênitas , Estudos Transversais , Feminino , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Gravidez , Ultrassonografia Pré-Natal
2.
Echocardiography ; 38(5): 777-789, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33778977

RESUMO

Volume ultrasound has been shown to provide valid complementary information on fetal anatomy. Four-dimensional assessment (4D) of the fetal cardiovascular system using spatial-temporal image correlation (STIC) allows for detailed examination of a highly complex organ from the early second trimester onward. There is compelling evidence that this technique harbors quite a number of diagnostic opportunities, but manual navigation through STIC volume datasets is highly operator dependent. In fact, STIC is not incorporated yet into daily practice. Application of the novel fetal intelligent navigation echocardiography (FINE) considerably simplifies fetal cardiac volumetric examinations. This automatic technique applied on cardiac volume datasets reportedly has both high sensitivity and specificity for the detection of congenital heart defects (CHDs). Part I reviewed current data regarding detection rates of CHDs and illustrated the additional value of an automatic approach in delineating cardiac anatomy exemplified by congenital lesions of the right heart. In part II of this pictorial essay, we focused on left heart anomalies and aimed to tabulate recent findings on the quantification of normal and abnormal cardiac anatomy.


Assuntos
Coração Fetal , Cardiopatias Congênitas , Ecocardiografia , Ecocardiografia Quadridimensional , Feminino , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Gravidez , Segundo Trimestre da Gravidez , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA