Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Tipo de documento
Intervalo de ano de publicação
4.
World Neurosurg ; 125: 519-526.e1, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30743042

RESUMO

BACKGROUND: Acupuncture is a common form of alternative medicine that is used for pain control among other modalities of treatment. It is a relatively safe procedure, but complications, including those of infectious etiology, may still occur. CASE DESCRIPTION: A 47-year-old immunosuppressed woman presented with fever, altered level of consciousness, dysphasia, and a left occipital subgaleal fluctuant mass after acupuncture for headaches in the same area. Imaging demonstrated subgaleal and epidural collection localized in the left occipital region. She underwent urgent surgical evacuation of both collections. Cultures from intraoperative specimens grew Streptococcus anginosus. The patient started targeted antibiotic treatment leading to complete recovery. CONCLUSIONS: To our knowledge, this is the first report of intracranial abscess after acupuncture. Given the worldwide application of this alternative treatment, physicians, acupuncturists, and the general public should be aware of the possibility of this rare but serious complication.


Assuntos
Terapia por Acupuntura/efeitos adversos , Abscesso Epidural/etiologia , Infecções Estreptocócicas/etiologia , Feminino , Humanos , Pessoa de Meia-Idade , Neuralgia/terapia , Lobo Occipital , Streptococcus anginosus
5.
Opt Lett ; 39(12): 3638-41, 2014 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-24978556

RESUMO

We report a polarization diversity detection scheme for optical coherence tomography with a new, custom, miniaturized fiber coupler with single mode (SM) fiber inputs and polarization maintaining (PM) fiber outputs. The SM fiber inputs obviate matching the optical lengths of the X and Y OCT polarization channels prior to interference and the PM fiber outputs ensure defined X and Y axes after interference. Advantages for this scheme include easier alignment, lower cost, and easier miniaturization compared to designs with free-space bulk optical components. We demonstrate the utility of the detection system to mitigate the effects of rapidly changing polarization states when imaging with rotating fiber optic probes in Intralipid suspension and during in vivo imaging of human airways.


Assuntos
Tomografia de Coerência Óptica/métodos , Emulsões , Endoscopia/instrumentação , Endoscopia/métodos , Desenho de Equipamento , Tecnologia de Fibra Óptica , Humanos , Miniaturização , Fibras Ópticas , Fenômenos Ópticos , Fosfolipídeos , Sistema Respiratório/anatomia & histologia , Óleo de Soja , Tomografia de Coerência Óptica/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA