Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Thyroid ; 31(8): 1160-1170, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34042535

RESUMO

Background: Biotin has been reported to interfere with several commonly used laboratory assays resulting in misleading values and possible erroneous diagnosis and treatment. This report describes a prospective study of possible biotin interference in thyroid-related laboratory assays, with a comparison of different commonly used assay platforms. Materials and Methods: Thirteen adult subjects (mean age 45 ± 13 years old) were administered biotin 10 mg/day for eight days. Blood specimens were collected at three time points on day 1 and on day 8 (baseline, two, and five hours after biotin ingestion). Thyrotropin (TSH), free triiodothyronine (fT3), free thyroxine (fT4), total triiodothyronine (TT3), total thyroxine (TT4), thyroxine binding globulin (TBG), and thyroglobulin (Tg) levels were analyzed with four different platforms: Abbott Architect, Roche Cobas 6000, Siemens IMMULITE 2000, and liquid chromatography with tandem mass spectrometry (LC-MS/MS). TSH, fT3, fT4, TT3, and TT4 were measured with Abbott Architect and Roche Cobas 6000. fT3, fT4, TT3, and TT4 were also measured by LC-MS/MS. Tg was measured by Siemens IMMULITE 2000. TBG was assessed with Siemens IMMULITE 2000. Results: Significant changes in TSH, fT4, and TT3 measurements were observed after biotin exposure when the Roche Cobas 6000 platform was used. Biotin intake resulted in a falsely lower Tg level when measurements were performed with Siemens IMMULITE 2000. At the time points examined, maximal biotin interference was observed two hours after biotin exposure both on day 1 and day 8. Conclusions: A daily dose of 10 mg was shown to interfere with specific assays for TSH, fT4, TT3, and Tg. Physicians must be aware of the potential risk of erroneous test results in subjects taking biotin supplements. Altered test results for TSH and Tg can be particularly problematic in patients requiring careful titration of levothyroxine therapy such as those with thyroid cancer.


Assuntos
Biotina/análise , Biotina/farmacologia , Tireoglobulina/análise , Hormônios Tireóideos/análise , Tireotropina/análise , Adulto , Idoso , Cromatografia Líquida de Alta Pressão , Reações Falso-Negativas , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Estudos Prospectivos , Testes de Função Tireóidea
2.
Endocrinol Metab Clin North Am ; 48(1): 181-197, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30717901

RESUMO

This article presents an overview of the use of radioactive iodine (131-I) in the treatment of patients with differentiated thyroid cancer. Topics reviewed include definitions; staging; the 2 principal methods for selection of 131-I dosage; the indications for ablation, adjuvant treatment, and treatment; the recommendations for the use of 131-I contained in the guidelines of the American Thyroid Association and the Society of Nuclear Medicine and Molecular Imaging; the dosage recommendations and selection of dosage approach for 131-I by these organizations; the use of recombinant human thyrotropin for radioiodine ablation, adjuvant therapy, or treatment; and the MedStar Washington Hospital Center approach.


Assuntos
Radioisótopos do Iodo/uso terapêutico , Neoplasias da Glândula Tireoide/radioterapia , Humanos , Radioisótopos do Iodo/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA