Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Orthop Sci ; 21(6): 836-840, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27522609

RESUMO

BACKGROUND: Total hip arthroplasty (THA) for sequelae of Legg-Calve-Perthes disease (LCPD) involves specific concerns for deformity, leg length discrepancy (LLD), and relatively young age. Excellent long-term outcome has been proven after Alumina-Alumina (Al-Al) THA for relatively young patients, however, there was no study for Al-Al THA for LCPD sequelae. The aim of this study is to evaluate the results of Al-Al THA for LCPD sequelae and to compare the results with those for adult-onset ONFH, in which THA is necessitated in relatively young age and excellent long term outcome has been proven after Al-Al THA. METHODS: Between 1997 and 2007, 41 Al-Al THA were performed in 37 patients with LCPD sequelae and followed-up for mean 10.4 years. Mean age at THA was 43.6 years. Using the propensity score matching, 41 THAs in 37 patients were identified from 339 hips in 256 patients with ONFH. The medical record and radiographic data was retrospectively reviewed. RESULTS: During follow-up, no revision was performed in both group. Harris Hip Score increased from 66.7 ± 17.4 points to 96.8 ± 6.8 points in LCPD group and from 47.9 ± 18.4 to 96.6 ± 4.6 in ONFH group. LLD decreased significantly from 2.0 ± 1.2 cm to 0.2 ± 0.9 cm in LCPD group and from 0.5 cm to 0.1 cm in ONFH group. Postoperative LLD showed no difference in both groups. As for complication, rate of intraoperative femoral fracture was significantly higher in LCPD group than in ONFH group. Other postoperative complication showed no difference. CONCLUSIONS: Despite the higher rate of intraoperative femoral crack, outcomes of Al-Al THA for LCPD were comparable to those for ONFH. Similar to ONFH, Al-Al THA may be a reliable treatment option for LCPD.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/métodos , Necrose da Cabeça do Fêmur/epidemiologia , Necrose da Cabeça do Fêmur/cirurgia , Doença de Legg-Calve-Perthes/cirurgia , Desenho de Prótese/métodos , Adulto , Idade de Início , Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos , Estudos de Coortes , Feminino , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Seguimentos , Humanos , Doença de Legg-Calve-Perthes/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
2.
J Korean Med Sci ; 31(1): 80-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26770042

RESUMO

The aim of this study was to examine the incidence and trends of clinically relevant venous thromboembolism (VTE) including deep vein thrombosis (DVT) and pulmonary embolism (PE) after hip and knee replacement arthroplasty (HKRA) in Korea. Between January 1 and December 31, 2010, 22,127 hip replacement arthroplasty (HRA) patients and 52,882 knee replacement arthroplasty (KRA) patients were enrolled in the analysis using the administrative claims database of the Health Insurance Review and Assessment Service (HIRA). All available parameters including procedure history and clinically relevant VTE during the 90 days after HKRA were identified based on diagnostic and electronic data interchange (EDI) codes. The overall incidence of VTE, DVT, and PE during the 90 days was 3.9% (n=853), 2.7% (n=597), and 1.5% (n=327) after HRA, while the incidence was 3.8% (n=1,990), 3.2% (n=1,699), and 0.7% (n=355) after KRA. The incidence of VTE after HKRA was significantly higher in patients who had previous VTE history (odds ratio [OR], 10.8 after HRA, OR, 8.5 after KRA), chronic heart failure (2.1, 1.3), arrhythmia (1.8, 1.7), and atrial fibrillation (3.4, 2.1) than in patients who did not. The VTE incidence in patients with chemoprophylaxis was higher than that in patients without chemoprophylaxis. The incidence of VTEs revealed in this retrospective review was not low compared with the results of the studies targeting other Asian or Caucasian populations. It may warrant routine prevention including employment of chemoprophylaxis. However, the limitation of the reviewed data mandates large scale prospective investigation to affirm this observation.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Tromboembolia Venosa/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Programas Nacionais de Saúde , Razão de Chances , República da Coreia/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Tromboembolia Venosa/epidemiologia
3.
J Arthroplasty ; 28(1): 132-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23164837

RESUMO

We evaluated the outcomes of 64 consecutive revision total hip arthroplasties with an alumina-on-alumina bearing surface in 61 patients with osteolysis. No implants had been rerevised nor was osteolysis detected at a mean of 9.8 years (range, 7.0-13.1 years) postoperatively. There was 1 case of stem loosening but no cup loosening or alumina bearing fractures. Two surgical procedures were performed for an infection in 1 patient. Three dislocations occurred in 3 hips; all were treated with closed reduction and abduction bracing for 3 months. No further dislocations occurred. With any reoperation or radiographic evidence of osteolysis or loosening as the end point, the 7-year survival rate was 96.9% (95% confidence interval, 90.8%-100%). The alumina-on-alumina bearing surfaces used for revision total hip arthroplasty in patients with osteolysis were found to produce encouraging clinical results and implant survival rates at a minimum of 7 years postoperatively.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril , Prótese de Quadril , Osteólise/cirurgia , Adulto , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , Adulto Jovem
4.
Arch Orthop Trauma Surg ; 133(3): 413-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23212650

RESUMO

PURPOSE: In an alumina-on-alumina total hip arthroplasty (THA), recommended with a small inclination angle <45°, the acetabular component (cup) may be positioned more medially to be covered almost completely by host bone. The purpose of this study was to identify the correlating factors and to evaluate the outcomes of medial placement of the cup in patients with alumina-on-alumina THAs. METHODS: Using the propensity score matching with age, gender, body mass index, initial diagnosis, and the length of follow-up as variables, 38 hips with a medialized cup and 38 hips with a non-medialized one were identified from 389 hips in 347 who patients underwent primary alumina-on-alumina THA and followed up for more than 7 years. Clinical and radiological outcomes were compared between the two groups. RESULTS: Preoperative acetabular medial wall thickness and the cup inclination angle were significantly smaller in the medialization group compared to the non-medialization group. Center edge angle, cup size, and coverage by host bone were not significantly different between the two groups. The hip center of rotation was significantly medialized in the medialization group. The Harris hip scores were not significantly different between the two groups. No component loosening or osteolysis was observed and no revision was required in either groups. CONCLUSIONS: Thin acetabular medial wall and a small inclination angle of the cup were the correlating factors of medial placement of the cup in patients who underwent an alumina-on-alumina THA. Medial placement did not lead to differences in the clinical or radiological outcomes.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Próteses Articulares Metal-Metal , Osteoartrite do Quadril/cirurgia , Adolescente , Adulto , Idoso , Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Materiais Biocompatíveis , Feminino , Articulação do Quadril , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Desenho de Prótese , Adulto Jovem
5.
Clin Orthop Relat Res ; 470(12): 3530-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22826015

RESUMO

BACKGROUND: THA in patients younger than 30 years presents challenges because of uncertainties regarding the long-term survivorship of prostheses. Alumina-on-alumina bearings, which exhibit little long-term wear, may be a reasonable option but the long-term survivorship is unknown. QUESTIONS/PURPOSES: We determined (1) the survival rate of alumina-on-alumina bearings in patients younger than 30 years after a 10-year followup, (2) the incidence of audible hip clicking and squeaking, (3) radiographic evidence of osteolysis, and (4) the effects on pregnancy, childbirth, and career choice. METHODS: We retrospectively reviewed 62 patients who had 75 THAs with alumina-on-alumina bearings followed more than 10 years (average, 11.5; range, 10-13.5 years). Mean patient age at the time of surgery was 24 years (range, 18-30 years). All operations were performed using the same cementless implant at a single center. We determined survival, presence of osteolysis, and function (Harris hip score, WOMAC). RESULTS: The 10-year survival rate of alumina-on-alumina bearings in THAs, with revision for any reason as the end point, was 98.9%. Audible hip clicking and squeaking were identified in 10 hips and two hips, respectively. No osteolysis was detected. None of the 11 patients who became pregnant had been affected by their THA during pregnancy or childbirth. Seven of the 14 patients who were unemployed at the time of index surgery stated that their THA affected their job choice. CONCLUSIONS: We found a high 10-year survival of cementless alumina-on-alumina bearings in THAs in patients younger than 30 years. Lifetime events such as job choice, pregnancy, and childbirth should be considered when choosing THA for patients younger than 30 years. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Artropatias/cirurgia , Adolescente , Adulto , Fatores Etários , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Escolha da Profissão , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Artropatias/diagnóstico por imagem , Artropatias/fisiopatologia , Estimativa de Kaplan-Meier , Masculino , Ruído , Osteólise/etiologia , Parto , Gravidez , Desenho de Prótese , Falha de Prótese , Radiografia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
J Arthroplasty ; 27(2): 324.e9-324.e12, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21435828

RESUMO

Although the incidence of malignant tumors in patients undergoing total hip arthroplasties (THAs) is known to be lower than the general population, there exist several reports on the development of malignant tumors at the site of THAs. We report another case of malignant fibrous histiocytoma at the site of a THA, which was developed in an older patient who presented a cystic mass around the total hip prosthesis using a ceramic-on-ceramic bearing system, even without evidence of osteolysis or loosening of implants. This is the second case associated with an aluminum oxide prosthesis in English literature.


Assuntos
Óxido de Alumínio/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Neoplasias Ósseas/diagnóstico , Bursite/diagnóstico , Articulação do Quadril , Prótese de Quadril/efeitos adversos , Histiocitoma Fibroso Maligno/diagnóstico , Idoso de 80 Anos ou mais , Artrografia , Artroplastia de Quadril/instrumentação , Neoplasias Ósseas/etiologia , Neoplasias Ósseas/terapia , Terapia Combinada , Erros de Diagnóstico , Evolução Fatal , Feminino , Necrose da Cabeça do Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Histiocitoma Fibroso Maligno/etiologia , Histiocitoma Fibroso Maligno/terapia , Humanos , Imageamento por Ressonância Magnética , Osteonecrose/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
J Bone Joint Surg Am ; 92(8): 1715-9, 2010 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-20660234

RESUMO

We previously reported the five-to-six-year results of the use of third-generation alumina-on-alumina bearings in a consecutive series of 100 primary cementless total hip arthroplasties. This report presents the longer-term outcomes of these same bearings, at a minimum of ten years postoperatively. Eighty-six of eighty-eight hips available for the study retained the original bearings at the time of the latest follow-up. Thirteen hips were associated with noise, and six hips demonstrated fretting of the femoral neck on radiographs. Two hips required a change of the bearings because of a ceramic head fracture. The ten-year survival rate of the alumina-on-alumina total hip prostheses, with revision of any implant for any reason as the end point, was 99.0%. On the basis of those results, we concluded that the rate of survival of primary cementless total hip prostheses with third-generation alumina-on-alumina bearings is excellent at ten years. However, the risk of ceramic fracture, noise, and impingement between the metal neck and the ceramic liner should be a concern to surgeons, and patients should be informed of these risks before surgery.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artropatias/cirurgia , Adolescente , Adulto , Idoso , Óxido de Alumínio , Materiais Biocompatíveis , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
8.
J Biomed Mater Res B Appl Biomater ; 85(1): 204-9, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17854069

RESUMO

We aimed to investigate the transfer of metal to both ceramic (alumina) and metal (cobalt-chrome) heads that were scraped by a titanium alloy surface under different load conditions. The ceramic and metal heads for total hip arthroplasties were scraped by an acetabular metal shell under various loads using a creep tester. Microstructural changes in the scraped area were visualized with a scanning electron microscope, and chemical element changes were assessed using an energy dispersive X-ray spectrometry. Changes in the roughness of the scraped surface were evaluated by a three-dimensional surface profiling system. Metal transfer to the ceramic and metal heads began to be detectable at a 10 kg load, which could be exerted by one-handed force. The surface roughness values significantly increased with increasing test loads in both heads. When the contact force increased, scratching of the head surface occurred in addition to the transfer of metal. The results documented that metallic debris was transferred from the titanium alloy acetabular shell to both ceramic and metal heads by minor scraping. This study suggests that the greatest possible effort should be made to protect femoral heads, regardless of material, from contact with metallic surfaces during total hip arthroplasty.


Assuntos
Acetábulo/patologia , Óxido de Alumínio/química , Ligas de Cromo/química , Cabeça do Fêmur/patologia , Teste de Materiais , Metais/química , Desenho de Prótese , Acetábulo/anatomia & histologia , Ligas/química , Artroplastia de Quadril , Materiais Revestidos Biocompatíveis/química , Análise de Falha de Equipamento , Cabeça do Fêmur/anatomia & histologia , Prótese de Quadril , Humanos , Falha de Prótese , Estresse Mecânico , Propriedades de Superfície , Titânio/química
10.
Clin Orthop Relat Res ; 458: 106-10, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17179781

RESUMO

Advances in technology have reduced the risk of fracture of ceramic total hip arthroplasty implants, but concerns remain about fracture of both components. We retrospectively reviewed 133 patients (157 hips) who had cementless alumina-on-alumina total hip arthroplasties with a sandwich-type acetabular component. Six patients (seven hips) died and five patients (six hips) were interviewed by telephone (95% followup). The 122 patients (144 hips) examined had a minimum followup of 36 months (average, 45 months; range, 36-68 months). All acetabular cups and femoral stems were radiographically stable at the last followup. Five hips in five patients (3.5%) were revised because of ceramic liner fractures. Ceramic liner fractures occurred at a mean of 35 months (range, 24-48 months) postoperatively. Acetabular cups in the fracture group (n = 5) were more anteverted than those in the nonfracture group (n = 139). In three patients the fracture apparently occurred during squatting, resulting in hyperflexion and wide hip abduction. Early ceramic liner fracture was associated with impingement associated with excessive anteversion of the acetabular cup in Korean patients who habitually squat.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Cimentos Ósseos , Prótese de Quadril , Complicações Pós-Operatórias , Falha de Prótese , Adolescente , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Cimentos Ósseos/uso terapêutico , Cerâmica , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Reoperação , Estudos Retrospectivos
11.
J Biomed Mater Res B Appl Biomater ; 78(1): 70-5, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16506182

RESUMO

Ceramic-on-ceramic bearing surfaces in total hip arthroplasties (THAs) are an attractive alternative coupling and may offer a promising option for young active patients. We evaluated the clinical results of 72 contemporary primary cementless alumina-on-alumina THAs performed in 61 patients younger than 40 years (mean age, 30 years), after a 5-year minimum follow-up. Most patients (97%) were able to return to their prearthritic activity levels, and none changed occupation because of a postoperative hip joint problem. No implant loosened radiographically and no stem or cup was revised. Ceramic wear was undetectable in 24 hips, where differentiation of the femoral head from the cup was possible on radiographs and no osteolysis was observed. One ceramic fracture following a major motor vehicle accident and a recurrent subluxation-associated ceramic liner edge fracture attributed to inadequate hip muscle tone occurred. We believe that this alternative articulation offers a promising option for young active patients. However, our findings also suggest that contemporary ceramic implant fracture is not a potential, but a real danger. Careful preoperative patient evaluation, proper indications for ceramic bearings, and meticulous surgical techniques are recommended to minimize the possibility of modern ceramic failure.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril , Materiais Biocompatíveis , Prótese de Quadril , Adulto , Feminino , Seguimentos , Humanos , Masculino , Fatores de Tempo
12.
J Bone Joint Surg Am ; 87(3): 530-5, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15741618

RESUMO

BACKGROUND: Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contemporary alumina-on-alumina total hip arthroplasties with regard to wear, osteolysis, and fracture of the ceramic after a minimum duration of follow-up of five years. METHODS: We evaluated the results of a consecutive series of 100 primary alumina-on-alumina total hip arthroplasties that had been performed with use of a metal-backed socket and a cementless stem in eighty-four patients. All of the patients were sixty-five years of age or younger (mean age, forty-one years), and a single surgeon performed all of the procedures. After a minimum duration of follow-up of sixty months, one patient (one hip) had died and four patients (six hips) had been lost to follow-up, leaving a total of seventy-nine patients (ninety-three hips) available for study. All of these patients were evaluated clinically and radiographically with special attention to wear, periprosthetic osteolysis, and ceramic failure. RESULTS: The mean Harris hip score was 97 points at the time of the latest follow-up evaluation. All prostheses demonstrated radiographic evidence of bone ingrowth. No implant was loose radiographically, and no implant was revised. Ceramic wear was not detectable in the thirty-seven hips in which the femoral head could be differentiated from the cup on radiographs. Periprosthetic osteolysis was not observed in any hip. A fracture of the alumina femoral head and a peripheral chip fracture of the alumina insert occurred in one hip following a motor-vehicle accident. CONCLUSIONS: The results of contemporary alumina-on-alumina total hip arthroplasty with a metal-backed socket and a cementless stem were encouraging after a minimum duration of follow-up of five years. We believe that these improved alumina-on-alumina bearing implants offer a promising option for younger, active patients.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Adolescente , Adulto , Idoso , Óxido de Alumínio , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Osteólise/etiologia , Desenho de Prótese , Falha de Prótese , Radiografia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA