Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Zhongguo Zhen Jiu ; 43(8): 921-4, 2023 Aug 12.
Artigo em Chinês | MEDLINE | ID: mdl-37577889

RESUMO

OBJECTIVE: To compare the clinical effect between heat-sensitive moxibustion and mild moxibustion for migraine without aura. METHODS: A total of 54 patients with migraine without aura were randomized into an observation group (27 cases, 2 cases dropped off) and a control group (27 cases, 2 cases dropped off). The basic western medication treatment was adopted in the two groups. In the control group, mild moxibustion was applied at Shuaigu (GB 8), Fengchi (GB 20) and Yanglingquan (GB 34) on the affected side. In the observation group, the frequent acupoint areas of the affected side i.e. Shuaigu (GB 8), Fengchi (GB 20), Taiyang (EX-HN 5), Taichong (LR 3), Yanglingquan (GB 34) were determined, 3 acupoints with strong heat-sensitive sensation were selected each time and mild moxibustion was adopted. The treatment was given once a day, 5 times of treatment was as one course and 2 courses were required in the two groups. Before and after treatment, the scores of migraine symptom, visual analogue scale (VAS), migraine specific quality of life questionnaire (MSQ) were observed, and the clinical efficacy was evaluated after treatment in the two groups. RESULTS: After treatment, the scores of migraine symptom and VAS were decreased compared with those before treatment (P<0.01), while the MSQ scores were increased compared with those before treatment (P<0.01) in the two groups. After treatment, the scores of migraine symptom and VAS in the observation group were lower than those in the control group (P<0.05), while the MSQ score in the observation group was higher than that in the control group (P<0.01). The total effective rate was 92.0% (23/25) in the observation group, which was superior to 72.0% (18/25) in the control group (P<0.05). CONCLUSION: Both heat-sensitive moxibustion and mild moxibustion can effectively alleviate the clinical symptoms, improve the headache degree and life quality in patients with migraine without aura, the clinical efficacy of heat-sensitive moxibustion is superior to that of mild moxibustion.


Assuntos
Terapia por Acupuntura , Enxaqueca sem Aura , Moxibustão , Humanos , Enxaqueca sem Aura/terapia , Temperatura Alta , Qualidade de Vida , Pontos de Acupuntura , Resultado do Tratamento
2.
Lipids Health Dis ; 15: 19, 2016 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-26823374

RESUMO

BACKGROUND: The 3D structure and functions of ENPP4, a protein expressed on the surface of Bacillus Calmette-Guerin (BCG)-activated macrophages, are unknown. In this study, we analyzed the 3D structure of ENPP4 and determined its tumoricidal effects on MCA207 cells. RESULTS: Homology modeling showed that Arg305, Tyr341, Asn291, and Asn295 are important residues in substrate, adenosine triphosphate (ATP), binding. A molecular dynamics study was also carried out to study the stability of ENPP4 (including zinc atoms) as well as its ligand-enzyme complex. BCG increased ENPP4 expression in macrophages, and specific blocking of ENPP4 in BCG-activated macrophages (BAMs) significantly reduced their cytotoxicity against MCA207 cells. CONCLUSIONS: These results indicate that zinc remains inside the ENPP4 protein, a BCG activated tumoricidal macrophage protein, throughout the simulation. Important information for the design of new inhibitors was obtained.


Assuntos
Macrófagos/metabolismo , Simulação de Acoplamento Molecular , Mycobacterium bovis/fisiologia , Diester Fosfórico Hidrolases/química , Homologia Estrutural de Proteína , Sequência de Aminoácidos , Animais , Anticorpos/metabolismo , Domínio Catalítico , DNA Complementar/genética , Feminino , Camundongos Endogâmicos C57BL , Dados de Sequência Molecular , Diester Fosfórico Hidrolases/metabolismo , Filogenia , Proteínas Recombinantes/metabolismo , Reprodutibilidade dos Testes , Alinhamento de Sequência , Software , Especificidade por Substrato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA