Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
NMR Biomed ; 29(3): 256-63, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26647020

RESUMO

An often-employed strategy to enhance signals in (31) P MRS is the generation of the nuclear Overhauser effect (NOE) by saturation of the water resonance. However, NOE allegedly increases the variability of the (31) P data, because variation is reported in NOE enhancements. This would negate the signal-to-noise (SNR) gain it generates. We hypothesized that the variation in NOE enhancement values is not caused by the variability in NOE itself, but is attributable to measurement uncertainties in the values used to calculate the enhancement. If true, the expected increase in SNR with NOE would improve the repeatability of (31) P MRS measurements. To verify this hypothesis, a repeatability study of native and NOE-enhanced (31) P MRSI was performed in the brains of seven healthy volunteers at 7 T. The repeatability coefficient (RC) and the coefficient of variation in repeated measurements (CoVrepeat ) were determined for each method, and the 95% limits of agreement (LoAs) between native and NOE-enhanced signals were calculated. The variation between the methods, defined by the LoA, is at least as great as that predicted by the RC of each method. The sources of variation in NOE enhancements were determined using variance component analysis. In the seven metabolites with a positive NOE enhancement (nine metabolite resonances assessed), CoVrepeat improved, on average, by 15%. The LoAs could be explained by the RCs of the individual methods for the majority of the metabolites, generally confirming our hypothesis. Variation in NOE enhancement was mainly attributable to the factor repeat, but between-voxel effects were also present for phosphoethanolamine and (glycero)phosphocholine. CoVrepeat and fitting error were strongly correlated and improved with positive NOE. Our findings generally indicate that NOE enhances the signal of metabolites, improving the repeatability of metabolite measurements. Additional variability as a result of NOE was minimal. These findings encourage the use of NOE-enhanced (31) P MRSI. Copyright © 2015 John Wiley & Sons, Ltd.


Assuntos
Encéfalo/metabolismo , Imageamento Tridimensional , Espectroscopia de Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Metaboloma , Fósforo , Reprodutibilidade dos Testes , Adulto Jovem
2.
NMR Biomed ; 28(11): 1570-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26492089

RESUMO

The design and construction of a dedicated RF coil setup for human brain imaging ((1)H) and spectroscopy ((31)P) at ultra-high magnetic field strength (7 T) is presented. The setup is optimized for signal handling at the resonance frequencies for (1)H (297.2 MHz) and (31)P (120.3 MHz). It consists of an eight-channel (1)H transmit-receive head coil with multi-transmit capabilities, and an insertable, actively detunable (31)P birdcage (transmit-receive and transmit only), which can be combined with a seven-channel receive-only (31)P array. The setup enables anatomical imaging and (31)P studies without removal of the coil or the patient. By separating transmit and receive channels and by optimized addition of array signals with whitened singular value decomposition we can obtain a sevenfold increase in SNR of (31)P signals in the occipital lobe of the human brain compared with the birdcage alone. These signals can be further enhanced by 30 ± 9% using the nuclear Overhauser effect by B1-shimmed low-power irradiation of water protons. Together, these features enable acquisition of (31)P MRSI at high spatial resolutions (3.0 cm(3) voxel) in the occipital lobe of the human brain in clinically acceptable scan times (~15 min).


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Lobo Occipital/metabolismo , Compostos de Fósforo/metabolismo , Espectroscopia de Prótons por Ressonância Magnética/instrumentação , Espectroscopia de Prótons por Ressonância Magnética/métodos , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Magnetismo/instrumentação , Masculino , Imagem Molecular/instrumentação , Lobo Occipital/anatomia & histologia , Fósforo/farmacocinética , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA