Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 158, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378564

RESUMO

BACKGROUND: One of the major contributors to disability in Knee osteoarthritis (KOA) patients is weakness in the Quadriceps Femoris muscle. Neuromuscular electrical stimulation (NMES) has been used in rehabilitation for patients suffering from muscle weakness. Thus, the purpose of the study was to assess the effectiveness of NMES and exercise therapy, for improving pain, muscle weakness and function among patients with KOA. METHODS: A randomized controlled trial was conducted with 75 female patients diagnosed with KOA. Participants were divided into three intervention groups: NMES-only, exercise therapy (Exs) alone, and a combination of NMES and exercise (NMES + Exs). All patients underwent 12 supervised treatment sessions, three times a week. Outcome measures included pain intensity measured by visual analog scale (VAS), knee flexion range of motion (FROM), thigh muscle girth (TG), thickness of the Vastus Medialis Oblique (VMO), timed up and go test (TUG), six-minute walk test (6MWT), and WOMAC scores. Statistical analyses (ANOVA and Kruskal-Wallis) methods were done to compare the amounts at the baseline, immediately after treatment and after 12 weeks. RESULTS: The NMES group exhibited a significant reduction in pain at the 12-week follow-up compared to the other groups(p = 0.022). The NMES + Exs group showed better outcomes in terms of FROM, TG, and VMO thickness post-intervention (p < 0.0001, p < 0.004, p = 0.003, respectively) and at the 12-week follow-up (p < 0.0001, p < 0.0001, p < 0.0001, respectively). Additionally, NMES was superior in improving TUG and 6MWT post-intervention (p < 0.0001, p = 0.038, respectively) and during the follow-up assessments (p < 0.0001, p = 0.029, respectively). The NMES + Exs group achieved better WOMAC stiffness scores at both post-intervention and follow-up evaluations (p < 0.0001, p < 0.0001, respectively). Furthermore, at the 12-week follow-up, NMES + Exs group outperformed the others in WOMAC pain and function subscales (p = 0.003, p = 0.017, respectively), while the NMES group demonstrated better WOMAC total scores compared to the other groups (p = 0.007). CONCLUSION: The combination of NMES and exercise seems to be an efficient approach for managing KOA, as it enhances knee flexion range and TG, increases VMO thickness, and improves WOMAC scores. On the other hand, NMES alone was found to be effective in improving the physical function of KOA patients. TRIAL REGISTRATION: IRCT20101228005486N7 (06-02-2020).


Assuntos
Terapia por Estimulação Elétrica , Osteoartrite do Joelho , Humanos , Feminino , Músculo Quadríceps , Terapia por Estimulação Elétrica/métodos , Seguimentos , Equilíbrio Postural , Estudos de Tempo e Movimento , Dor , Debilidade Muscular , Estimulação Elétrica
2.
BMC Musculoskelet Disord ; 25(1): 114, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326840

RESUMO

BACKGROUND: Approximately 80% of all proximal humeral fractures (PHFs) are non-displaced or minimally displaced fractures, which can be treated with conservative treatment. This study investigated the effect of interferential current (IFC) added to orthopedic rehabilitation on shoulder function, pain, and disability in patients with PHF. METHODS: This study was a prospective, double-blind, randomized, placebo-controlled conducted in physical medicine and rehabilitation outpatient clinic. Thirty-five patients were randomly separated into the IFC group (n = 18) and the sham group (n = 17). The orthopedic rehabilitation program was applied to all patients by the same physiotherapist three times a week for four weeks. Patients in the IFC group received the intervention for 20 minutes 3 times a week before the exercise. The same pads were performed for the sham group, but no electrical stimulation was applied. Constant-Murley score (CMS) for shoulder function, visual analog scale (VAS) activity pain, disabilities of the arm, shoulder, and hand (DASH) score, and paracetamol intake were recorded post-treatment, at 6 weeks and 18 weeks post-treatment. RESULTS: The demographic and fracture characteristics were not different between the groups. Significant differences were observed in the IFC and sham group in intragroup comparisons of total CMS, VAS activity pain, DASH score, and paracetamol intake over time (p < 0.001). Significant improvement over time was valid for all pairwise comparisons in both groups. However, no significant differences were detected between the IFC and sham group. CONCLUSION: IFC added to orthopedic rehabilitation could not appear to be an electrotherapy modality that could potentially benefit shoulder function and disability in patients with PHF.


Assuntos
Acetaminofen , Fraturas do Ombro , Humanos , Estudos Prospectivos , Resultado do Tratamento , Método Duplo-Cego , Fraturas do Ombro/terapia , Dor
3.
Neurogastroenterol Motil ; 35(11): e14618, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37288650

RESUMO

BACKGROUND/PURPOSE: Gastrointestinal (GI) dysmotility is categorized by muscle or nerve dysfunctions in any portion of the GI tract, which leads to abnormalities in GI motor and sensory function. Symptoms may vary depending on the organ affected and can be debilitating. Treatment usually involves diet and lifestyle changes. Pharmacotherapy is limited in effectiveness with various side effects. Transcutaneous electrical stimulation (TES), a noninvasive, needleless technique that provides electrical stimulation using cutaneous non-needle electrodes, has become increasingly popular. It has been shown to be beneficial in treating GI motility disorders. METHODS: This review paper navigates through the different TES techniques, including transcutaneous peripheral nerve (vagal/sacral/tibial nerves) electrical stimulation, transcutaneous electrical acustimulation (stimulation via acupuncture point), transcutaneous interferential current therapy, and transcutaneous electrical nerve stimulation. KEY RESULTS: As we delve deeper, we explore the promising effects of TES on dysphagia, gastroesophageal reflux disease, functional dyspepsia, gastroparesis, postoperative ileus, constipation, and irritable bowel syndrome. The literature at hand speaks volumes about the therapeutic prowess of this noninvasive technique. CONCLUSION & INFERENCES: The time is ripe to evaluate further the full therapeutic potential of TES, a noninvasive, nonpharmaceutical, nonsurgical, and home-based self-administrative technique in managing GI motility disorders.


Assuntos
Gastroenteropatias , Estimulação Elétrica Nervosa Transcutânea , Humanos , Estimulação Elétrica Nervosa Transcutânea/métodos , Constipação Intestinal , Motilidade Gastrointestinal/fisiologia
4.
Physiother Theory Pract ; 39(6): 1133-1140, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35171084

RESUMO

BACKGROUND: Labor pain is one of the most severe pains experienced by a woman during her life. Interferential current (IFC) is a type of transcutaneous electrical stimulation that can reduce pain, especially deep ones. OBJECTIVE: This randomized controlled clinical trial (RCT) aimed to study the effects of quadripolar IFC on pain and the duration of the active phase of labor in primiparous women. METHOD: In this RCT, 60 primiparous women were randomized into two groups of IFC and sham IFC. The IFC group received IFC in two periods. The sham group received sham IFC. Primary outcomes were labor pain in different times of active phase and duration of active phase, and secondary outcomes were delivery satisfaction; the number of infants transferred to neonatal intensive care units (NICUs), fetal heart rate (FHR) disorders, Apgar score, partograph variables, and adverse side effects were recorded. RESULT: Between-group changes showed a significant decrease in labor pain during the active phase in the IFC group compared to the sham IFC group (mean difference (MD) = -0.95; 95% confidence interval (95% CI) = -1.35 to -0.55; P < .001). The mean of active phase duration was significantly shorter in the IFC group than in the sham IFC group (MD = -38.25; 95% CI = -62.84 to -13.67; P = .003). CONCLUSION: This study showed the effectiveness of interferential electrical stimulation during labor to reduce pain and duration of the active phase, which can be valuable in improving the quality of care and encouraging natural childbirth.


Assuntos
Terapia por Estimulação Elétrica , Dor do Parto , Estimulação Elétrica Nervosa Transcutânea , Gravidez , Feminino , Recém-Nascido , Humanos , Dor do Parto/diagnóstico , Dor do Parto/terapia , Medição da Dor , Estimulação Elétrica
5.
Physiother Theory Pract ; 39(10): 2087-2098, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-35505631

RESUMO

BACKGROUND: Interferential current (IFC) is a non-pharmacological therapy often used to reduce pain intensity. However, there is no scientific evidence of the biological effects of the adjustment of IFC intensity of stimulation. OBJECTIVE: To investigate whether the adjustment of IFC intensity influences pain on cutaneous sensory threshold (CST), pressure pain threshold (PPT) and pain intensity in healthy subjects under mechanically induced pain. METHODS: This is a placebo-controlled randomized trial. One hundred and two healthy university students blinded to intervention were randomized using opaque sealed envelopes to the following groups: 1) sensory IFC (n = 24); 2) fixed motor IFC (n = 26); 3) adjusted motor IFC (n = 27); and 4) placebo IFC (n = 25). After 40 minutes of stimulation or placebo, subjects were evaluated by an investigator blinded to group allocation. CST (von Frey filaments), PPT (algometry), and pain intensity (11-point numerical scale) were measured. RESULTS: Adjusted motor IFC promoted a significant reduction of CST (hand: mean difference (MD) = 2.39, confidence intervals (CI) = 1.39-3.38; and forearm: MD = 3.01, CI = 2.87-3.14) compared to placebo. Adjusted motor IFC increased PPT significantly (hand: MD = 27.59, CI = 26.80-28.37; and forearm: MD = 34, CI = 25.74-42.25) when compared to placebo. Adjusted motor IFC reduced pain intensity by 4.01 points (CI = 3.64-4.55) when compared to placebo. No adverse events were observed. CONCLUSIONS: Adjusted motor IFC intensity increased PPT and CST and also reduced pain intensity in healthy subjects under mechanically induced pain.


Assuntos
Dor , Estimulação Elétrica Nervosa Transcutânea , Humanos , Voluntários Saudáveis , Dor/etiologia , Limiar da Dor , Medição da Dor , Mãos
6.
Artigo em Inglês | MEDLINE | ID: mdl-36293928

RESUMO

Electrical currents are didactic contents widely applied in the training of physiotherapy students, but the treatment is considered a stressful situation for both the patient who receives it and the student who applies it. The aim of this study was to evaluate the stress-associated autonomic response of physiotherapy students receiving interferential current by measuring and analysing heart rate variability. An observational case-control study was conducted. Ninety healthy male volunteers, all physiotherapy degree students, were enrolled while attending laboratory practice during the 2020-2021 academic year. Participants were randomly allocated to a sham electrotherapy group (44 subjects), in which heart rate variability was recorded for 10 min, both at rest and during the application of sham technique on the lower back (10 min), and an electrotherapy group (46 subjects), applying the same procedure with the electrical current flowing. Outcome measures included baseline (seated position) and postintervention (prone position) time domain parameter, diameters of the Poincaré plot 1 and 2, stress score, and sympathetic/parasympathetic ratio. The sham electrotherapy group exhibited significant increases in time domain parameter (p = 0.027) and diameters of the Poincaré plot 1 (p = 0.032), with a small effect size (d ≤ 0.5). The electrotherapy group exhibited significant increases in time domain parameter and diameters of the Poincaré plot 1 and 2 (p < 0.001) and decreases in the stress score and sympathetic/parasympathetic ratio (p < 0.001), with a large effect size (d > 0.8) other than for the time domain parameter (d = 0.42), indicating increased parasympathetic and decreased sympathetic activity. After interventions, there were significant differences between groups in diameters of the Poincaré plot 2 (p < 0.001), stress score (p = 0.01) and sympathetic/parasympathetic ratio (p = 0.003), with moderate effect size (d > 0.5). The application of the interferential current technique produces stress-associated autonomic response characterized by greater parasympathetic activity and decreased sympathetic activity. Further studies are needed to determine possible adverse effects.


Assuntos
Terapia por Estimulação Elétrica , Humanos , Masculino , Estudos de Casos e Controles , Frequência Cardíaca/fisiologia , Modalidades de Fisioterapia/educação , Estudantes
7.
Medicina (Kaunas) ; 58(1)2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35056448

RESUMO

Background and Objectives: Transcutaneous electrical stimulation of low- and medium-frequency currents is commonly used in pain management. Interferential current (IFC) therapy, a medium frequency alternating current therapy that reportedly reduces skin impedance, can reach deeper tissues. IFC therapy can provide several different treatment possibilities by adjusting its parameters (carrier frequency, amplitudemodulated frequency, sweep frequency, sweep mode or swing pattern, type of application (bipolar or quadripolar), time of application and intensity). The objective of this review article is to discuss the literature findings on the analgesic efficacy of IFC therapy. Conclusions: According to the literature, IFC therapy shows significant analgesic effects in patients with neck pain, low back pain, knee osteoarthritis and post-operative knee pain. Most of the IFC parameters seem not to influence its analgesic effects. We encourage further studies to investigate the mechanism of action of IFC therapy.


Assuntos
Terapia por Estimulação Elétrica , Dor Lombar , Estimulação Elétrica Nervosa Transcutânea , Analgésicos/uso terapêutico , Humanos , Dor Lombar/terapia , Manejo da Dor
8.
J Back Musculoskelet Rehabil ; 35(2): 363-371, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34180407

RESUMO

BACKGROUND: Electrotherapy is part of a physician's toolbox for treating various musculoskeletal conditions, including radicular pain, but the preferred modality is yet unclear. OBJECTIVE: To compare the short-term efficacy of three electrotherapeutic modalities in relieving lumbar disc herniation (LDH)-induced radicular pain. METHODS: Fourteen patients with LDH-induced radicular pain attended a single session of electrotherapy, which included four 10-min consecutive treatments: transcutaneous electrical nerve stimulation (TENS), interferential (IF) stimulation, a combined treatment with pulsed ultrasound and IF current (CTPI), and a sham control. Treatments were randomized and the straight leg raise (SLR) degree was measured immediately before and after each treatment. RESULTS: Each of the three active modalities significantly improved the SLR score. The most prominent improvement was observed in the CTPI condition, followed by IF and, finally, TENS. The sham stimulation did not affect the SLR scores. CONCLUSIONS: A single session with either TENS, IF current or CTPI is sufficient to improve the range of motion and degree of radicular pain associated with LDH. CTPI appears to be the most effective modality of the three, possibly due to greater penetration efficiency of the induced current. The effects of a long-term treatment schedule are yet to be identified.


Assuntos
Terapia por Estimulação Elétrica , Deslocamento do Disco Intervertebral , Estimulação Elétrica Nervosa Transcutânea , Humanos , Deslocamento do Disco Intervertebral/complicações , Deslocamento do Disco Intervertebral/terapia , Dor/complicações , Resultado do Tratamento , Ondas Ultrassônicas
9.
Neuromodulation ; 25(8): 1403-1409, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34405486

RESUMO

OBJECTIVES: Transcutaneous electrical nerve stimulation (TENS) and interferential currents (IFC) are pain electrotherapies with questioned efficacy. Studies of their effects on tactile acuity of individuals with nonspecific chronic low back pain (NSCLBP) are limited, hence, this study. MATERIALS AND METHODS: Thirty-three individuals with NSCLBP randomly allocated into three groups completed this study. Data collected from participants included age, gender, and anthropometric characteristics of height, weight, body mass index, and percentage body fat measured with standard instruments. Also, participants' tactile acuity, pain intensity, and disability were assessed before and after interventions with digital caliper, numerical pain rating scale, and Roland-Morris Disability Questionnaire, respectively. Interventions consisted of stretching, strengthening, and stabilization exercises to all three groups in addition of TENS to group 1 and IFC to group 2, respectively, for five weeks. Descriptive statistics of mean and standard deviation summarized the data. Inferential statistics of paired t-test, independent t-test, and analysis of variance tested the level of significance among variables at p ≤ 0.05. RESULTS: Tactile acuity was significantly (p < 0.05) increased after TENS intervention only, while pain intensity was significantly (p < 0.05) reduced after the three interventions. The result showed no gender difference in tactile acuity values among the participants. CONCLUSIONS: TENS increases the tactile acuity of individuals with NSCLBP, whereas IFC demonstrated no significant change in tactile acuity.


Assuntos
Terapia por Estimulação Elétrica , Dor Lombar , Estimulação Elétrica Nervosa Transcutânea , Humanos , Dor Lombar/diagnóstico , Dor Lombar/terapia , Manejo da Dor , Medição da Dor , Resultado do Tratamento
10.
Diagnostics (Basel) ; 11(12)2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34943411

RESUMO

Interferential current therapy (ICT) is an electrotherapeutic intervention that combines the advantages of high permeability from middle frequency currents and efficient tissue stimulation from low frequency currents, delivering the maximum current with high tissue permeability. The aim was to evaluate the effects of ICT on heart rate variability (HRV) and on pain perception in patients with non-specific chronic low back pain (NSCLBP). In the study, 49 patients with NSCLBP were randomly divided into an experimental (EG) and a sham group (SG). All participants received a single intervention, ICT, or simulated intervention. Outcome measures including baseline (sit-down position) and postintervention (prone position) pain, heart rate (HR), time domain parameter (rMSSD), diameters of the Poincaré plot (SD1, SD2), stress score (SS), and sympathetic/parasympathetic (S/PS) ratio were investigated. In both groups, significant statistical differences were found in perceived pain and in all HRV parameters except in HRmax. Between-group comparisons showed statistically significant differences in all variables except for HRmin and HRmean in favor of the experimental group. These changes reported an increase in parasympathetic activity (rMSSD) (p < 0.05) and a decrease in sympathetic activity (increase in SD2 and decrease in SS) (p < 0.001) and perceived pain (p < 0.001), with a greater size effect (η2 = 0.44) in favor of the experimental group. In conclusion, a single session of ICT can shift the autonomic balance towards increase parasympathetic dominance and decrease the sympathetic dominance and intensity of pain perceived by patients with NSCLBP.

11.
Neuromodulation ; 23(8): 1061-1081, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32017319

RESUMO

BACKGROUND: In the last 20 years, studies have shown that large bowel function can be modified by neural stimulation. While still in its infancy, this area of research is beginning to show promise. METHODS: This overview brings together systematic reviews and meta-analyses of electrical stimulation used to treat colonic disorders (fecal incontinence, constipation, slow transit constipation [STC], irritable bowel syndrome [IBS-C], and spina bifida-neurogenic bowel). Different methods of electrical stimulation including through sacral nerves, paraspinal, transabdominal, and using electroacupuncture over the ankle or knee and direct stimulation of the bowel are reviewed. RESULTS AND DISCUSSION: Most evidence is low level (pilot and small cohort studies) but with more RCTs appearing. Sacral nerve stimulation (SNS) does improve urinary dysfunction and fecal incontinence but not constipation. It is expensive with high rates of reoperation. Transcutaneous stimulation with interferential current (IFC, alternating current at KHz frequency with 2 channels out of phase) does improve constipation and may provide benefit as an adjuvant to behavioral or exercise therapies. Acupuncture and electro-acupuncture (low/very low-level evidence) may have a benefit for constipation. CONCLUSION: SNS is effective but expensive and limited to extreme patients. Transcutaneous stimulation is noninvasive and cheap and IFC may be effective for constipation, but many parameters need to be optimized and higher level evidence provided from studies (sham, blinding, and larger patient numbers). The next 20 years should be exciting in the field as higher level studies are performed.


Assuntos
Colo/fisiopatologia , Constipação Intestinal , Terapia por Estimulação Elétrica , Incontinência Fecal , Constipação Intestinal/terapia , Estimulação Elétrica , Eletroacupuntura , Incontinência Fecal/terapia , Humanos , Metanálise como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Nervos Espinhais , Revisões Sistemáticas como Assunto , Resultado do Tratamento
12.
Arch Physiother ; 10: 2, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31938571

RESUMO

BACKGROUND: Hemiplegic Shoulder Pain (HSP) is among common complications occurring after stroke leading to disability. This study was conducted to compare the effects of electrical Interferential Current stimulation (IFC) and Electrical Acupuncture (EAC) on pain intensity, range of motion, and functional ability in patients with HSP and also comparing the two modalities regarding improvement of above indices. METHODS: In this randomized clinical trial, 46 patients with HSP caused by ischemic stroke were recruited and assigned into 2 groups. Conventional exercise trainings were applied for both groups. Group A received additional IFC with medium frequency of 4000 HZ, and Group B received additional EAC two times a week for a total of 10 sessions. Pain severity, daily function, and shoulder Range of Motion (ROM) were evaluated using Visual Analogue Scale (VAS), Shoulder Pain and Disability Index (SPADI), and goniometry, respectively before and 5 weeks after the treatment. RESULTS: Both groups showed relative improvement in pain severity, SPADI score, and its subscales, and also active and passive shoulder ROM after the treatment. However, IFC group compared to EAC group had higher mean changes of active ROM in abduction (28.00 ± 3.81 vs. 12.25 ± 2.39) and functional subscale of SPADI (11.45 ± 1.88 vs. 5.80 ± 1.66) after the treatment. On the contrary, EAC group showed higher percentage of VAS changes (46.14 ± 6.88 vs. 34.28 ± 5.52), indicating better pain improvement compared to IFC group. Other parameters did not show significant difference between two groups. CONCLUSION: Both IFC and EAC caused short term improvement in functional state, increased motion, and decreased pain in patients with HSP. Although pain control was more evident in acupuncture group, IFC resulted in better effects on function and active ROM of abduction, and seems to have higher efficacy. TRIAL REGISTRATION: This clinical trial was registered in the Iranian Registry of Clinical Trials at 2016-07-16 with a registry number of IRCT201602153217N10.

13.
Clin Rehabil ; 33(6): 1027-1034, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30764635

RESUMO

OBJECTIVE: To investigate the effectiveness of interferential current implementation following total knee arthroplasty surgery. DESIGN: Double-blind randomized controlled study. SETTING: Orthopedics and traumatology in-patient clinic. PARTICIPANTS: From an initial enrollment of 132 patients, 113 who met the study inclusion criteria were randomly separated into two groups: the interferential current group ( n = 57) and the sham current group ( n = 56). A total of 98 patients completed the study: 49 in the interferential current group and 49 in the sham group. INTERVENTION: Patients in the interferential current group received interferential current treatment for 30 minutes, twice a day for five days postoperatively. For the patients in the sham interferential current treatment group, the same pads were applied to the patients for the same time periods but no electrical stimulation was applied. MAIN OUTCOME MEASURES: Patients were assessed in respect of pain, range of motion (ROM), edema, and the amount of paracetamol used at baseline and on the 5th and 30th days after surgery. RESULTS: No significant difference was determined between the groups in respect of pain, ROM, and edema at days 0, 5, and 30. At the end of the 5th day, the amount of paracetamol used was significantly lower in the interferential current group ( P < 0.05). CONCLUSION: In this study, both groups showed significant improvements in pain, ROM, and edema with no significant difference between the groups. Although there was a significant difference in paracetamol intake of the two groups, this cannot be argued as showing the effectiveness of interferential current.


Assuntos
Artroplastia do Joelho , Edema/terapia , Dor Pós-Operatória/terapia , Amplitude de Movimento Articular , Estimulação Elétrica Nervosa Transcutânea , Acetaminofen/uso terapêutico , Idoso , Analgésicos não Narcóticos/uso terapêutico , Método Duplo-Cego , Feminino , Humanos , Masculino , Cuidados Pós-Operatórios , Complicações Pós-Operatórias/terapia , Escala Visual Analógica
14.
Neuromodulation ; 22(6): 669-679, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30451336

RESUMO

OBJECTIVES: Postoperative ileus occurs in approximately 5-15% of patients following major abdominal surgery, and poses a substantial clinical and economic burden. Electrical stimulation has been proposed as a means to aid postoperative gastrointestinal (GI) recovery, but no methods have entered routine clinical practice. A systematic review was undertaken to assess electrical stimulation techniques and to evaluate their clinical efficacy in order to identify promising areas for future research. MATERIALS AND METHODS: Literature was searched using MEDLINE, EMBASE, Google Scholar and by assessing relevant clinical trial databases. Studies investigating the use of electrical stimulation for postoperative GI recovery were included, regardless of methods used or outcomes measured. A critical review was constructed encompassing all included studies and evaluating and synthesizing stimulation techniques, protocols, and clinical outcomes. RESULTS: A broad range of neuromodulation strategies and protocols were identified and assessed. Improved postoperative GI recovery following electrical stimulation was reported by 55% of studies (10/18), most commonly those assessing transcutaneous electrical nerve stimulation and electroacupuncture therapy (7/10). Several studies reported shorter time to first flatus and stool, shorter duration of hospital stay, and reduced postoperative pain. However, inconsistent reporting and limitations in trial design were common, compromising a definitive determination of electrical stimulation efficacy. CONCLUSIONS: Electrical stimulation appears to be a promising methodology to aid postoperative GI recovery, but greater attention to mechanisms of action and clinical trial quality is necessary for progress. Future research should also aim to apply validated and standardized gut recovery outcomes and consistent neuromodulation methodologies.


Assuntos
Trato Gastrointestinal/fisiologia , Cuidados Pós-Operatórios/métodos , Recuperação de Função Fisiológica/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Eletrodos Implantados , Humanos , Íleus/etiologia , Íleus/terapia , Cuidados Pós-Operatórios/instrumentação , Estimulação Elétrica Nervosa Transcutânea/instrumentação
15.
Hong Kong Physiother J ; 39(2): 133-142, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31889764

RESUMO

BACKGROUND: Knee osteoarthritis (KOA) is a common degenerative articular disease that causes disability and poor quality of life (QoL) of the individuals. Electrotherapeutic agents such as therapeutic ultrasound (US), interferential current (IFC), and infrared radiation are used in the treatment. It is not clear which of these agents is the best in improving these variables. OBJECTIVE: The study aimed to compare the effects of the combined application of US and IFC therapies and infrared radiation on pain, functional activities, and QoL in people with KOA. METHODS: In a randomized controlled study, 60 participants were randomized into two groups, the combination therapy group (CTG) and the infrared radiation group (IRG). Each group received 15-min treatment three times per week for 12 weeks. The visual analog scale (VAS) was used to assess the pain, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) for functional activities and the Short Form Health Survey questionnaire for QoL. RESULTS: Participants in the CTG had a significant ( p < 0 . 05 ) reduction in pain and significant ( p < 0 . 05 ) improvement in functional activities and QoL compared to the IRG. CONCLUSION: The results of this study support the use of the combination of IFC and US therapies to reduce pain and improve function and QoL for KOA patients.

16.
Pain Manag ; 8(6): 465-474, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30394194

RESUMO

AIM: To evaluate whether active interferential current (AIC) before pilates exercises improves pain faster than placebo interferential current (PIC) in patients with chronic nonspecific low back pain (CNLBP). METHODS: A total of 142 patients with CNLBP were treated with AIC or PIC before pilates exercises. Pain intensity was measured daily before and after treatment by Pain Numerical Rating Scale. Statistical analysis was performed using survival analysis for Kaplan-Meier method. RESULTS: The AIC group presented 30% reduction of pain one session, 50% reduction of pain two sessions and 100% reduction of pain three sessions faster than the PIC group and these improvements were statistically significant (p < 0.05). CONCLUSION: The AIC before pilates exercises can reduce pain faster than PIC in patients with CNLBP.


Assuntos
Dor Crônica/terapia , Terapia por Estimulação Elétrica , Técnicas de Exercício e de Movimento , Dor Lombar/terapia , Adulto , Dor Crônica/complicações , Terapia Combinada , Feminino , Humanos , Dor Lombar/complicações , Masculino , Pessoa de Meia-Idade , Medição da Dor , Resultado do Tratamento
17.
Trials ; 19(1): 518, 2018 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-30249298

RESUMO

BACKGROUND: In recent years, the number of arthroscopic shoulder surgeries has increased given that the intervention is minimally invasive. However, postoperative pain is one of the most common symptoms of patients who undergo arthroscopic surgery. Although pharmacological treatments and brachial plexus blocks for reducing pain are currently used, the adherence rate of interventions is low, and adverse effects often occur. Chimsband, made up of silver and optic fibres, is a novel taping therapy that stimulates patients' acupoints and is expected to relieve pain with few adverse effects. The aim of this study is to explore the effectiveness of Chimsband to relieve pain following arthroscopic shoulder surgery. METHODS/DESIGN: This is a randomised, parallel, controlled, exploratory clinical trial. Thirty participants who undergo arthroscopic shoulder surgery will be randomly allocated to an intervention or a control group. Both groups will receive 10 sessions of interferential current therapy within a period of 2 weeks, while the intervention group will additionally receive taping therapy after undergoing physical therapy. Two follow-up visits will be scheduled after the last treatment session. The primary outcome variable will be the difference in the visual analogue scale (VAS) scores between baseline and first follow-up evaluation after the end of 10 treatment sessions. The secondary outcomes will be VAS at the end of the second week, shoulder pain and disability index, range of motion, VAS while sleeping, questionnaire of blood stasis pattern identification at two follow-up visits, and number of bands used per visit. Outcomes will be evaluated at baseline, 2 weeks from visit 1 (+ within 6 days) after commencement, and at 4 weeks from visit 1 (+ within 6 days) follow-up. DISCUSSION: This study will be the first clinical trial to explore the effect and safety of Chimsband on postoperative shoulder pain. It would provide clinical evidence to conduct further taping therapy studies for relieving musculoskeletal pain. TRIAL REGISTRATION: Korean Clinical Trial Registry, KCT0002355 . Registered on 13 June 2017.


Assuntos
Artroscopia , Dor Pós-Operatória/prevenção & controle , Articulação do Ombro/cirurgia , Dor de Ombro/prevenção & controle , Fita Cirúrgica , Pontos de Acupuntura , Adulto , Idoso , Artroscopia/efeitos adversos , Fenômenos Biomecânicos , Avaliação da Deficiência , Terapia por Estimulação Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/fisiopatologia , Projetos Piloto , Ensaios Clínicos Controlados Aleatórios como Assunto , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , República da Coreia , Articulação do Ombro/fisiopatologia , Dor de Ombro/diagnóstico , Dor de Ombro/etiologia , Dor de Ombro/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
18.
Neuromodulation ; 21(7): 669-675, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29498773

RESUMO

BACKGROUND: Transcutaneous electrical stimulation (TES) using interferential current (IFC) is a new therapeutic treatment for constipation. Clinical studies show that TES-IFC for 3-6 months improves colonic transit, but it is not clear if short-term stimulation affects transit or the effect requires longer to develop. The aim of this study was to determine if TES-IFC for only four days affects oral-rectal transit time in healthy pigs. METHODS: Twenty-two 4-5-week old large white female piglets had transit studies during week 4 and week 5 by placing a capsule containing 18 radiopaque plastic markers in the esophagus under anesthetic followed by x-rays at 6, 30, 54, and 78 hours. Animals were randomly assigned to active or control groups. The active group received TES for 30 min daily for four days. Interferential current was applied through four electrodes (4 × 4 cm), with two para-spinal just below the last rib and two on the belly at the same level. Stimulation was at 4000 Hz and 4080-4160 Hz with currents crossing through the abdominal cavity. RESULTS: Whole bowel transit times ranged from 7.7 to 72.2 hours, stomach transit from <1 to 63 hours, and bowel with rectum transit time from 5 to 53 hours. Transit times were the same for the control (median 28.4 hours) and TES-IFC (23.0 hours) groups in the prestimulation and stimulation weeks (control 23.0, TES-IFC 19.8 hours) with no change within or between groups. CONCLUSION: Four days of half-hour TES-IFC daily in healthy 5-week-old piglets did not change oral-rectal transit time.


Assuntos
Abdome/inervação , Trânsito Gastrointestinal/fisiologia , Boca/fisiologia , Reto/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Abdome/diagnóstico por imagem , Animais , Feminino , Boca/diagnóstico por imagem , Boca/inervação , Distribuição Aleatória , Reto/diagnóstico por imagem , Reto/inervação , Suínos , Fatores de Tempo
19.
Pain Manag ; 8(2): 71-77, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29451431

RESUMO

The aim of the study will be to compare different types of analgesic electrical currents in relation to the pressure pain threshold and sensory comfort in healthy individuals. A total of 100 individuals will be randomly assigned to four groups: transcutaneous electrical nerve stimulation, interferential current, Aussie current or placebo. The electrical stimulation will be administered with a strong level for 30 min and to the placebo group, the electrodes will be positioned while the equipment will remain switched off. The pressure pain threshold and sensory comfort will be measured with an algometer and the visual analogue scale, respectively. The level of significance will be p < 0.05. STUDY REGISTRATION: NCT01950728 (clinical trials).


Assuntos
Manejo da Dor/métodos , Limiar da Dor , Estimulação Elétrica Nervosa Transcutânea/métodos , Humanos , Dor/prevenção & controle , Medição da Dor/métodos , Projetos de Pesquisa
20.
Neuromodulation ; 21(7): 676-681, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29164818

RESUMO

BACKGROUND: Transcutaneous electrical stimulation (TES) for one to two months has produced some improvement in treatment-resistant slow-transit constipation (STC) in children. Optimal parameters for treatment are not known. It is possible that more improvement would occur with stimulation for longer. This study examined the effectiveness of stimulation for six months. METHODS: Children with STC confirmed by nuclear transit study (NTS) were enrolled prospectively. All had chronic constipation for greater than two years and had failed medical treatment. TES was performed for one hour/day for six months using the INF 4160 (Fuji Dynamics) portable stimulator and 4 cm × 4 cm electrodes near the belly button and on the back. Families kept bowel diaries and completed PEDSQLCore QOL (4.0) questionnaires before and at end of treatment. RESULTS: Sixty-two children (34 females; seven years, 2-16 year) with STC were studied. Defecation frequency increased in 57/62 (91%, mean ± SEM pre- 1.49 ± 0.20 vs. post- 3.25 ± 0.25 defecation/week, p < 0.0001) with the number with ≥3BA increasing from 6 to 37 (10-59%). Soiling frequency decreased from 4.8 to 1.1 days/week (p <0.001). Abdominal pain decreased from 1.7 to 0.3 days/week (<0.0001), and spontaneous urge to defecate improved. Quality of life (p < 0.01), mean transit index and gastric emptying on NTS improved (p < 0.005). CONCLUSION: Treatment-resistant STC responds to TES using interferential current across the abdomen when given daily for many months. Battery operated stimulators allowed stimulation at home for an hour each day. Stimulation for six months produced clinically significant improvement in defecation frequency, soiling, abdominal pain, urge to defecate, and quality of life in half of these chronic patients.


Assuntos
Abdome/inervação , Constipação Intestinal/terapia , Serviços de Assistência Domiciliar , Estimulação Elétrica Nervosa Transcutânea/métodos , Adolescente , Fatores Etários , Criança , Pré-Escolar , Defecação/efeitos dos fármacos , Feminino , Seguimentos , Trânsito Gastrointestinal/fisiologia , Humanos , Laxantes/uso terapêutico , Masculino , Modalidades de Fisioterapia , Estudos Retrospectivos , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA