Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Esthet Restor Dent ; 36(3): 453-459, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37705502

RESUMO

OBJECTIVE: To evaluate the effect of coffee thermocycling (CTC) on the surface roughness (Ra ) and stainability of denture base materials with different chemical compositions fabricated by using additive and subtractive manufacturing. MATERIALS AND METHODS: Disk-shaped specimens were additively (FREEPRINT denture, AM) or subtractively (G-CAM, GSM and M-PM, SM) fabricated from three pink denture base materials in different chemical compositions (n = 10). Ra was measured before and after polishing, while color coordinates were measured after polishing. Specimens were subjected to CTC (5000 cycles) and measurements were repeated. Color differences (ΔE00 ) after CTC were calculated. Ra among different time intervals within materials was evaluated by using repeated measures analysis of variance (ANOVA), while 1-way ANOVA was used to evaluate the Ra of different materials within each time interval and the ΔE00 values. Color coordinates within each material were compared by using paired samples t-tests (α = 0.05). RESULTS: Ra before polishing was the highest for all materials (p < 0.001), while SM had its lowest Ra after CTC and AM had its lowest Ra after polishing (p ≤ 0.008). Before polishing, AM had the highest Ra among the materials (p < 0.001). After polishing, SM had higher Ra than AM (p < 0.001). After CTC, GSM had the lowest Ra (p ≤ 0.048). SM had the lowest (p ≤ 0.031) and AM had the highest (p < 0.001) ΔE00 . CTC decreased the a* and b* values of SM and AM (p ≤ 0.017), and increased the L* values of AM (p < 0.001). CONCLUSIONS: Polishing significantly reduced the surface roughness of all materials. CTC did not increase the surface roughness of materials above the clinically acceptable threshold. Only AM had perceptible color change when previously reported threshold values for denture base materials were considered. CLINICAL SIGNIFICANCE: Tested denture base materials may have similar surface stability after coffee thermocycling. However, subtractively manufactured denture base materials may have improved color stability when subjected to long-term coffee consumption.


Assuntos
Café , Bases de Dentadura , Propriedades de Superfície , Polimento Dentário , Teste de Materiais , Cor
2.
J Esthet Restor Dent ; 36(3): 477-483, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37877244

RESUMO

OBJECTIVE: The purpose of this in vitro study was to evaluate the effect of potassium aluminum sulfate (alum) application on the stainability and translucency of computer-aided design and computer-aided manufacturing (CAD-CAM) materials after coffee thermocycling (CTC). MATERIALS AND METHODS: Disk-shaped specimens (Ø10 × 1 mm; N = 200) were fabricated by using additively (Crowntec [CT] and Varseo Smile Crown Plus [VS]) and subtractively manufactured (Brilliant Crios [RCR], CEREC Block [FC], and Vita Enamic [VE]) CAD-CAM materials and polished. All specimens were randomly divided into two groups as alum applied and control (n = 10). All specimens were then subjected to CTC (10,000 cycles at 5-55°C) and color coordinates were measured at each time interval. Color differences (ΔE00 ) and relative translucency parameters (RTPs) were calculated and the data were statistically analyzed (a = 0.05). RESULTS: Among tested time intervals, alum applied specimens had their lowest ΔE00 after alum application (p ≤ 0.006), except for FC (p = 0.177). In addition, alum applied RCR had lower ΔE00 values than its control specimens (p = 0.029). Alum applied specimens had their lowest RTP after CTC (p < 0.001) and alum application decreased the RTP of CT (p = 0.010). CTC reduced the RTP of all materials in control groups (p < 0.001). Alum applied CT had higher RTP than its control specimens (p = 0.049). CONCLUSIONS: Alum application's effect on color change varied depending on the material and alum mostly resulted in clinically acceptable changes in translucency. CTC led to unacceptable color and translucency changes based on previously reported threshold values. CLINICAL SIGNIFICANCE: Optical properties of CAD-CAM materials and the sustainability of these properties over time is critical for longevity. Alum may improve the color stability of reinforced composite resin when subjected to long-term coffee consumption.


Assuntos
Compostos de Alúmen , Café , Porcelana Dentária , Cor , Teste de Materiais , Propriedades de Superfície , Cerâmica , Desenho Assistido por Computador
3.
BMC Oral Health ; 22(1): 321, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35915423

RESUMO

The long-term color stability and gloss retention of resin composites are among the crucial factors that affect the clinical longevity of esthetic restorations, especially in anterior teeth. This study evaluated the effect of artificial aging by immersion in different storage media and thermocycling on color and gloss of dental single-shade resin composite (Omnichroma) versus multi-shade one (Filtek Z350XT). One hundred resin-composite disc-shaped specimens were used, 50 from each group, Omnichroma and Filtek Z350XT. Ten specimens from each material acted as control group (incubated in saliva). For each material, 40 specimens were divided according to the artificial-aging protocol (immersion at 37 °C for 12 days or thermocycling for 10,000 cycles) and storage media (tea, red wine). Color and gloss were measured before and after artificial aging. Color difference (∆E00) was compared with perceptibility threshold and acceptability threshold. Data were statistically analyzed; independent t test was used to compare results between two tested materials, while two-way ANOVA was used to compare results among the different immersion media within the same material. Artificial aging (immersion or thermocycling) in tea and red wine led to significant color changes and gloss reduction in both materials (P < 0.05), in contrast to control group. Red wine produced highest color differences. Both dental resin-composites; the single-shade (Omnichroma) and multi-shade (Filtek Z350XT) displayed unacceptable discoloration and gloss reduction after artificial-aging in tea and red-wine by immersion or thermocycling simulating one-year clinical-service.


Assuntos
Resinas Compostas , Chá , Cor , Humanos , Teste de Materiais , Propriedades de Superfície
4.
Materials (Basel) ; 15(12)2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35744291

RESUMO

Potassium aluminum sulfate (alum) is a known adjuvant, which has been used as a mordant in textile industry for color fixation. This material has potential to be incorporated into dentistry for color stability, yet its toxicity first needs to be evaluated. The present study aimed to evaluate the cytotoxic potential of potassium aluminum sulfate (alum) on fibroblasts when applied onto feldspathic ceramic before and after thermocycling. Forty-eight feldspathic ceramic specimens were divided into four groups (FC: no alum application or thermocycling; FCT: thermocycling without alum application; FA: alum application without thermocycling; FAT: alum application and thermocycling) (n = 12). Cell viability was assessed by using a tetrazolium salt 3-[4,5-dimethylthiazol-2-yl]-2,5-diphnyltetrazolium bromide assay at 24 and 72 h, and cell cultures without any ceramic specimens served as control (C). One sample from each material group was further analyzed with energy dispersive X-ray spectroscopy (EDX). Cell viability at different time intervals within each group was analyzed with Friedman tests, while Kruskal−Wallis tests were used to compare the test groups within each time interval. Pairwise comparisons were further resolved by using Wilcoxon tests (a = 0.05). C had lower (p = 0.01) and FA had higher (p = 0.019) cell viability after 72 h. After 24 h, the highest cell viability was observed in C (p ≤ 0.036). After 72 h, the differences between C and FA, C and FAT, FC and FA, and FCT and FAT were nonsignificant (p > 0.05). Cell viability was not affected by alum application or thermocycling at any time interval (p ≥ 0.631). EDX analysis showed an increase in potassium concentration in FA and FAT when compared with FC and FCT. Regardless of the time interval, alum application onto feldspathic ceramic and thermocycling did not influence the cell viability.

5.
Bol. malariol. salud ambient ; 62(3): 498-507, 2022. tab, graf
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1397150

RESUMO

La alta prevalencia de desgaste dental erosivo producido por la ingestión frecuente de bebidas gaseosas, se ha convertido en uno de los principales problemas de salud bucal en niños, adolescentes y adultos jóvenes, cuyo tratamiento deviene en desafío para los profesionales de la salud. La investigación se propuso evaluar el efecto erosivo exógeno de las bebidas gaseosas, sobre el tejido dentario mediante el proceso de termociclado in vitro, en el que se sometieron 50 premolares extraídos a la experiencia de exposición a una bebida gaseosa, bajo condiciones de experimentación, resultando una diferencia significativa entre el peso inicial pre termociclado en cada pieza y el peso final obtenido después del proceso, lo cual demuestra el efecto negativo del consumo de bebidas gaseosas. En ese mismo sentido, y como parte de esta investigación, se evaluó los efectos beneficiosos de los probióticos como la L-alanina como suplemento de las bacterias beneficiosas a la salud bucal como el Lactobalilos rhamnosus GG que logran detener el avance de bacterias patógenas y oportunistas como el Streptococcus mutans. Los resultados mostraron que a medida que aumenta la concentración del probiótico, mayor es la disminución del número de unidades formadoras de colonias y de las biopelículas de Streptococcus mutans. Además, la investigación aborda la percepción del riesgo en estudiantes, de ingestión de bebidas gaseosas en la erosión dentaria y los criterios que sobre el tema tienen sus profesores tutores(AU)


The high prevalence of erosive dental wear caused by the frequent ingestion of soft drinks has become one of the main oral health problems in children, adolescents and young adults, whose treatment becomes a challenge for health professionals. The research aimed to evaluate the exogenous erosive effect of soft drinks on dental tissue through the in vitro thermocycling process, in which 50 extracted premolars were subjected to the experience of exposure to a soft drink, under experimental conditions, resulting in a significant difference between the initial pre-thermocycling weight in each piece and the final weight obtained after the process, which demonstrates the negative effect of the consumption of soft drinks. In that same sense, and as part of this research, the beneficial effects of probiotics such as L-alanine were evaluated as a supplement for beneficial bacteria for oral health such as Lactobalilos rhamnosus GG, which manage to stop the advance of pathogenic and opportunistic bacteria such as Streptococcus mutans. The results showed that as the concentration of the probiotic increases, the decrease in the number of colony-forming units and biofilms of Streptococcus mutans is greater. In addition, the research addresses the perception of risk in students, of ingestion of soft drinks in dental erosion and the criteria that their tutor teachers have on the subject(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Arginina , Streptococcus mutans , Biofilmes , Lacticaseibacillus rhamnosus , Desgaste dos Dentes , Bactérias , Erosão Dentária , Bebidas Gaseificadas , Saúde Bucal , Probióticos , Ingestão de Alimentos
6.
J Esthet Restor Dent ; 33(8): 1132-1138, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34390305

RESUMO

OBJECTIVE: To investigate the effect of thickness, cement shade, and coffee thermocycling (CTC) on the optical properties of zirconia reinforced lithium silicate (ZLS) paired with different shades of a resin cement. MATERIALS AND METHODS: Thirty ZLS specimens were prepared in two different thicknesses (0.8 and 1.5 mm) and three different resin cement shades (Tr, A2, and A3) were applied (n = 5). Color determinations were done before and after 5000 CTC by using a noncontact spectroradiometer. Color change due to CTC and relative translucency parameter (RTP) before and after CTC were calculated by using CIEDE2000. Data were analyzed using ANOVA and Bonferroni-corrected t-tests(α = 0.05). RESULTS: Material thickness and resin cement shade (P < 0.001) affected baseline color. Material thickness affected color difference (P = 0.025). Thickness, resin cement shade, and CTC (P ≤ 0.0001) affected RTP. The difference between the color changes of the 0.8- and 1.5-mm specimens combined with A2 shade cement after CTC was significant (P = 0.01). RTPs of all pairs decreased after CTC (P < 0.001). CONCLUSIONS: Cement shade and material thickness affected the baseline color. The thickness of ZLS affected the color change after CTC only with A2 resin cement and the color change was less when the ZLS was thicker. CTC reduced the translucency of all pairs. CLINICAL SIGNIFICANCE: Clinicians and patients should be aware of a potential color change after long-term coffee consumption when zirconia reinforced lithium silicate is used particularly for laminate veneers with A2 shade of the tested resin cement.


Assuntos
Porcelana Dentária , Lítio , Cerâmica , Café , Cor , Desenho Assistido por Computador , Humanos , Teste de Materiais , Cimentos de Resina , Silicatos , Propriedades de Superfície , Zircônio
7.
J Dent ; 73: 19-23, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29597040

RESUMO

OBJECTIVE: To evaluate the effect of shading technique and thickness on the color stability and translucency of translucent zirconia after coffee thermocycling. METHODS: Specimens in different thicknesses (1; 1.5; 2 mm) (n = 4 for each thickness) were sectioned from translucent preshaded zirconia (Pre) and externally shaded zirconia (Ext). After sintering, specimens were glazed and subjected to 10,000 thermocycling in coffee solution. The color coordinates of specimens were measured with a spectroradiometer before and after coffee thermocyling. Color differences and relative translucency parameter (RTP) values were calculated with CIEDE2000 color difference and TPCIEDE2000 formulas. ANOVA was used to analyze the CIEDE2000 color difference and RTP values (α = 0.05). RESULTS: According to 2-way ANOVA, no significant effect of shading technique and thickness on the color difference values was found (P > .05). According to 3-way ANOVA, a significant interaction between the shading technique and thickness (P < .0001) was found for RTP. The RTP parameter decreased with the increase in the thickness. Ext specimens presented significantly higher RTP than Pre specimens (P < .0001), except for between Ext 1 mm and Pre 1 mm (P = .179). CONCLUSIONS: Neither shading technique nor tested thicknesses affected the color of translucent zirconia. Shading technique and thickness affected the RTP of translucent zirconia. The RTP was inversely affected with the thickness of the material. Externally shaded zirconia presented higher RTP than preshaded zirconia for specimens thicker than 1 mm. CLINICAL SIGNIFICANCE: Discoloration with coffee was insignificant for the tested translucent zirconia in tested thicknesses (1, 1.5, 2 mm). When a translucent restoration is intended, thinner externally shaded translucent zirconia restorations should be preferred instead of preshaded translucent zirconia.


Assuntos
Cor , Materiais Dentários/química , Teste de Materiais , Zircônio/química , Cerâmica/química , Café/efeitos adversos , Desenho Assistido por Computador , Porcelana Dentária , Planejamento de Prótese Dentária/métodos , Técnicas In Vitro , Pigmentação em Prótese , Propriedades de Superfície
8.
J Dent ; 71: 38-42, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29402640

RESUMO

OBJECTIVE: To compare the effect of material and thickness on the color stability and relative translucency parameters (RTP) for monolithic ceramics subjected to coffee thermocycling. METHODS: Four specimens each at thicknesses of 0.5, 0,7 and 1 mm were sectioned from monolithic ceramics [preshaded monolithic zirconia (MonZr), lithium disilicate (LDS) and zirconia reinforced lithium silicate (ZLS)]. The specimens were glazed and subjected to 5000 coffee thermocycling. The color coordinates of specimens were determined with a spectroradiometer and color differences and RTP values were calculated with CIEDE2000 color difference and TPCIEDE2000 formulas. ANOVA was used to analyze CIEDE2000 color difference and RTP values (α = .05). RESULTS: For the color difference data, the 2-way ANOVA revealed a significant interaction between material and different thickness (P = .002). Except for 0.5 mm thick ZLS material, all materials in all thicknesses studied presented color changes within the clinically acceptable limits after coffee thermocycling. For the RTP data, the 3-way ANOVA revealed a highly significant interaction between material and different thicknesses (P < .001). CONCLUSIONS: Material type and thickness can be expected to affect color change and relative translucency of the restorations made with preshaded MonZr, LDS and ZLS materials. Except for 0.5 mm thick ZLS material, color changes of all studied materials were within the clinically acceptable limits. Except ZLS material, color changes of other materials were not significantly affected by thickness. Staining in coffee was not found to affect translucency, and the materials' translucency parameters were ranked from high to low as LDS, ZLS and MonZr at each thickness studied.


Assuntos
Cerâmica/química , Desenho Assistido por Computador , Pigmentação em Prótese , Café , Cor , Porcelana Dentária/química , Planejamento de Prótese Dentária , Humanos , Lítio , Compostos de Lítio , Teste de Materiais , Silicatos , Propriedades de Superfície , Zircônio/química
9.
Artigo em Inglês | WPRIM | ID: wpr-23636

RESUMO

OBJECTIVES: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide (Al₂O₃) particles at different pressures. MATERIALS AND METHODS: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and χ² tests (α = 0.05). RESULTS: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. CONCLUSIONS: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.


Assuntos
Adesivos , Envelhecimento , Óxido de Alumínio , Fadiga , Microscopia Eletrônica de Varredura , Cimentos de Resina
10.
Artigo em Inglês | WPRIM | ID: wpr-169360

RESUMO

PURPOSE: The aim of this study was to investigate whether the application of nano-structured alumina coating to the surface of Y-TZP could enhance the bond strength with resin cement. MATERIALS AND METHODS: A total of 80 zirconia plates were prepared and divided into four groups. : 1) airborne particle abrasion treatment (A) : 2) Rocatec treatment after airborne particle abrasion (R) : 3) nano-structured alumina coating treatment after polishing (PC) and 4) nano-structured alumina coating after airborne particle abrasion (AC). Alumina coating was formed by the hydrolysis of aluminium nitride (AlN) powder and heat treatment at 900℃. Coating patterns were observed with FE-SEM. Resin block was bonded to treated zirconia ceramics using resin cement. The shear bond strengths were measured before and after thermocycling. RESULTS: The FE-SEM images show a dense and uniform nano-structured alumina coating structure, which enhances shear bond strength by increasing micro mechanical interlocking to resin cement. PC and AC groups showed higher shear bond strengths than A and R groups before and after thermocycling. A and R groups displayed significant drops in shear bond strength after thermocycling. However, PC and AC groups did not show any meaningful decreases in shear bond strength after thermocycling. CONCLUSION: Treatment of Y-TZP ceramics with nano-structured alumina coating could significantly increase their shear bond strength.


Assuntos
Óxido de Alumínio , Cerâmica , Temperatura Alta , Hidrólise , Cimentos de Resina
11.
Mater Sci Eng C Mater Biol Appl ; 54: 69-75, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26046269

RESUMO

The aim of this study was to investigate the effects of temperature change and immersion in two common beverages on the mechanical and tribological properties for three different types of dental restorative materials. Thermocycling procedure was performed for simulating temperature changes in oral conditions. Black tea and soft drink were considered for beverages. Universal composite, universal nanohybrid composite and universal nanofilled composite, were used as dental materials. The nanoindentation and nanoscratch experiments were utilized to determine the elastic modulus, hardness, plasticity index and wear resistance of the test specimens. The results showed that thermocycling and immersion in each beverage had different effects on the tested dental materials. The mechanical and tribological properties of nanohybrid composite and nanocomposite were less sensitive to temperature change and to immersion in beverages in comparison with those of the conventional dental composite.


Assuntos
Bebidas Gaseificadas , Resinas Compostas/química , Materiais Dentários/química , Nanocompostos/química , Chá , Temperatura , Módulo de Elasticidade , Dureza , Fenômenos Mecânicos , Nanotecnologia , Propriedades de Superfície
12.
Artigo em Inglês | WPRIM | ID: wpr-28671

RESUMO

PURPOSE: This study was performed to evaluate shear bond strength (SBS) between three dual-cured resin cements and silica coated zirconia, before and after thermocycling treatment. MATERIALS AND METHODS: Sixty specimens were cut in 15 x 2.75 mm discs using zirconia. After air blasting of 50 microm alumina, samples were prepared by tribochemical silica coating with Rocatec(TM) plus. The specimens were divided into three groups according to the dual-cure resin cement used: (1) Calibra silane+Calibra(R), (2) Monobond S+Multilink(R) N and (3) ESPN sil+RelyX(TM) Unicem Clicker. After the resin cement was bonded to the zirconia using a Teflon mold, photopolymerization was carried out. Only 10 specimens in each group were thermocycled 6,000 times. Depending on thermocycling treatment, each group was divided into two subgroups (n=10) and SBS was measured by applying force at the speed of 1 mm/min using a universal testing machine. To find out the differences in SBS according to the types of cements and thermocycling using the SPSS, two-way ANOVA was conducted and post-hoc analysis was performed by Turkey's test. RESULTS: In non-thermal aged groups, SBS of Multilink group (M1) was higher than that of Calibra (C1) and Unicem (U1) group (P<.05). Moreover, even after thermocycling treatment, SBS of Multilink group (M2) was higher than the other groups (C2 and U2). All three cements showed lower SBS after the thermocycling than before the treatments. But Multilink and Unicem had a significant difference (P<.05). CONCLUSION: In this experiment, Multilink showed the highest SBS before and after thermocycling. Also, bond strengths of all three cements decreased after thermocycling.


Assuntos
Óxido de Alumínio , Cerâmica , Fungos , Politetrafluoretileno , Cimentos de Resina , Dióxido de Silício
13.
Angle Orthod ; 84(4): 649-55, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24446920

RESUMO

OBJECTIVE: To evaluate the combined effects of material type, surface treatment, and thermocycling on the bond strength of orthodontic brackets to materials used for the fabrication of provisional crowns. MATERIALS AND METHODS: Four materials were included in this study (ProTemp, Trim Plus, Trim II, and Superpont C+B). Sixty cylindrical specimens (1 × 3 cm) were prepared from each material and equally divided into three groups. The first group was ground with silica carbide paper, the second was polished with pumice, and the last group was sandblasted with 50-µm aluminum oxide particles. Stainless-steel maxillary central incisor brackets (Victory Series, 3M) were bonded to the provisional material specimens with Transbond XT light-cured composite resin, and half of the specimens from each group were thermocycled 500 times in 5°C and 55°C water baths. Then the brackets were debonded with shear testing, and the results were statistically analyzed by three-way analysis of variance and Tukey's multiple-comparison tests at α  =  0.05. Adhesive Remnant Index (ARI) was also identified. RESULTS: Before and after thermocycling, ProTemp materials showed the highest shear bond strength with orthodontic brackets (10.3 and 13.1 MPa, respectively). The statistical analysis indicated an interaction among the three independent variables (P < .05) and statistically significant differences in bond strength among provisional materials (P < .001), surface treatments (P < .001), and thermocycling (P < .05). According to the ARI, most groups demonstrated adhesive failure. CONCLUSIONS: The provisional material type, surface treatment, and artificial aging have a significant effect on bond strength. Sandblasting treatment exerts a beneficial effect on shear bond strength.


Assuntos
Coroas , Colagem Dentária , Materiais Dentários/química , Braquetes Ortodônticos , Resinas Acrílicas/química , Óxido de Alumínio/química , Compostos Inorgânicos de Carbono/química , Resinas Compostas/química , Corrosão Dentária/métodos , Polimento Dentário/métodos , Restauração Dentária Temporária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Ácidos Polimetacrílicos/química , Cimentos de Resina/química , Resistência ao Cisalhamento , Silicatos/química , Compostos de Silício/química , Aço Inoxidável/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
14.
J Prosthodont ; 23(2): 117-23, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23890275

RESUMO

PURPOSE: The purpose of this in vitro study was to compare the shear bond strength of an airborne-particle abraded zirconia, an acid-etched zirconia (Piranha solution), an Alloy Primer treated zirconia, and a silaned zirconia to enamel, all bonded with a phosphate-methacrylate resin luting agent. MATERIALS AND METHODS: Seventy extracted intact human molars were collected, cleaned, and mounted in autopolymerizing acrylic resin, with the experimental surface of the teeth exposed. The specimens were randomly divided into seven groups of zirconia specimens (4 mm diameter, 2 mm thick). Group 1: Airborne-particle abrasion; group 2: Airborne-particle abrasion and Z-PRIME Plus; group 3: Airborne-particle abrasion and alloy primer; group 4: Piranha solution 7:1; group 5: Piranha solution 7:1 and Z-PRIME Plus; group 6: Piranha solution 7:1 and Alloy primer; group 7: CoJet and silane. All specimens were luted with a phosphate-methacrylate resin luting agent (Panavia F2.0) and stored in distilled water for 1 day, then thermocycled (5°C and 55°C) for 500 cycles and tested for shear bond strength (SBS), measured in MPa, with a universal testing machine at a 0.55 mm/min crosshead speed. All specimens were inspected under a scanning electron microscope to determine mode of failure. The mean values and standard deviations of all specimens were calculated for each group. A one-way ANOVA was performed, and multiple pairwise comparisons were then completed with post hoc Tukey test (alpha = 0.05). RESULTS: The airborne-particle abrasion and Z-PRIME Plus group resulted in a significantly higher SBS than the other groups (21.11 ± 6.32 MPa) (p < 0.001). The CoJet and silane group (15.99 ± 8.92 MPa) and airborne-particle abrasion and alloy primer group (11.07 ± 4.34 MPa) showed high shear bond strength but not statistically significant from the airborne-particle abrasion group (14.23 ± 5.68 MPa). Failure mode was predominately mixed in groups 1, 2, 3, and 7 with islands of retained resin on the zirconia and enamel surfaces; however, groups 4, 5, and 6 showed mostly adhesive failures, which left the zirconia surface free of the adhesive materials. No cohesive failures of the substrates (ceramic, resin, or enamel) were observed. CONCLUSION: Airborne-particle abrasion followed by the application of a zirconia primer produced the highest bond strength to enamel. Therefore, it can be recommended as a promising surface treatment method to achieve a durable bond to densely sintered zirconia ceramics.


Assuntos
Cerâmica/química , Colagem Dentária , Esmalte Dentário/ultraestrutura , Materiais Dentários/química , Ítrio/química , Zircônio/química , Condicionamento Ácido do Dente/métodos , Óxido de Alumínio/química , Bis-Fenol A-Glicidil Metacrilato/química , Corrosão Dentária/métodos , Análise do Estresse Dentário/instrumentação , Humanos , Peróxido de Hidrogênio/química , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Cimentos de Resina/química , Resistência ao Cisalhamento , Silanos/química , Estresse Mecânico , Ácidos Sulfúricos/química , Propriedades de Superfície , Temperatura , Tionas/química , Fatores de Tempo , Água/química
15.
Artigo em Coreano | WPRIM | ID: wpr-211541

RESUMO

An increasing demand for esthetic restorations has led to the development of new ceramic systems. In-Ceram, a glass-infiltrated alumina ceramic has three to four times greater flexural strength than other ceramic glass material. Because of its high strength, In-Ceram has been suggested as inlay, crown, laminate veneer and core material for resin bonded fixed partial dentures. This clinical application requires a stable resin bond to In-Ceram core. The purpose of this study was to evaluate the shear bond strength between In-Ceram core and resin cements according to various surface treatments and storage conditions. The surface of each In-Ceram core sample was subjected to one of the following treatments and then bonded to Panavia 21 or Variolink II resin cement. ; (1) sandblasting with 110 micrometer aluminum oxide powder, (2) sandblasting and silanization, (3) sandblasting and Siloc treatment, (4) sandblasting and Targis link application. Each of eight bonding groups was tested in shear bond strengths after the following storage times and thermocycling. ; A) 24 hours storage in distilled water at 371C, B) 5 weeks storage in dis tilled water at 37 C, C) 5 weeks storage in distilled water at 371C and thermocycled 2,000 ther mocycling for every 10 days(totally 10,000 thermocycling) in 51C - 551C bath. The bond failure modes were observed with scanning electron microscope (SEM). The results were as follows : 1. The shear bond strengths of sandblasting group were significantly lesser than the other groups after 24 hours water storage. 2. No significant difference of bonding strengths was found between storage time conditions (24 hours and 5 weeks). The shear bond strengths showed a tendency to decrease in Variolink II bonding groups and to increase in Panavia 21 bonding groups. 3. After thermocycling, the shear bond strengths of all groups were significantly decreased (p<0.01) and Targis link group exhibited significantly greater strengths than the other groups(p<0.05). 4. Panavia 21 bonding groups exhibited significantly greater bonding strengths in sandblasting group(p<0.01) and silane group(p<0.05) than Variolink II bonding groups. 5. In observation of bond failure modes, Targis link group showed cohesive failure in resin part and silane group and Siloc group showed complex failure and sandblasting group showed adhesive failure between In-Ceram and resin.


Assuntos
Adesivos , Óxido de Alumínio , Banhos , Cerâmica , Coroas , Prótese Parcial Fixa , Vidro , Restaurações Intracoronárias , Cimentos de Resina , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA