1.
Med Phys ; 51(2): 1421-1432, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38207016

RESUMO

BACKGROUND: The recent rediscovery of the FLASH effect, a normal tissue sparing phenomenon observed in ultra-high dose rate (UHDR) irradiations, has instigated a surge of research endeavors aiming to close the gap between experimental observation and clinical treatment. However, the dependences of the FLASH effect and its underpinning mechanisms on beam parameters are not well known, and large-scale in vivo studies using murine models of human cancer are needed for these investigations. PURPOSE: To commission a high-throughput, variable dose rate platform providing uniform electron fields (≥15 cm diameter) at conventional (CONV) and UHDRs for in vivo investigations of the FLASH effect and its dependences on pulsed electron beam parameters. METHODS: A murine whole-thoracic lung irradiation (WTLI) platform was constructed using a 1.3 cm thick Cerrobend collimator forming a 15 × 1.6 cm2 slit. Control of dose and dose rate were realized by adjusting the number of monitor units and couch vertical position, respectively. Achievable doses and dose rates were investigated using Gafchromic EBT-XD film at 1 cm depth in solid water and lung-density phantoms. Percent depth dose (PDD) and dose profiles at CONV and various UHDRs were also measured at depths from 0 to 2 cm. A radiation survey was performed to assess radioactivation of the Cerrobend collimator by the UHDR electron beam in comparison to a precision-machined copper alternative. RESULTS: This platform allows for the simultaneous thoracic irradiation of at least three mice. A linear relationship between dose and number of monitor units at a given UHDR was established to guide the selection of dose, and an inverse-square relationship between dose rate and source distance was established to guide the selection of dose rate between 20 and 120 Gy·s-1 . At depths of 0.5 to 1.5 cm, the depth range relevant to murine lung irradiation, measured PDDs varied within ±1.5%. Similar lateral dose profiles were observed at CONV and UHDRs with the dose penumbrae widening from 0.3 mm at 0 cm depth to 5.1 mm at 2.0 cm. The presence of lung-density plastic slabs had minimal effect on dose distributions as compared to measurements made with only solid water slabs. Instantaneous dose rate measurements of the activated copper collimator were up to two orders of magnitude higher than that of the Cerrobend collimator. CONCLUSIONS: A high-throughput, variable dose rate platform has been developed and commissioned for murine WTLI electron FLASH radiotherapy. The wide field of our UHDR-enabled linac allows for the simultaneous WTLI of at least three mice, and for the average dose rate to be modified by changing the source distance, without affecting dose distribution. The platform exhibits uniform, and comparable dose distributions at CONV and UHDRs up to 120 Gy·s-1 , owing to matched and flattened 16 MeV CONV and UHDR electron beams. Considering radioactivation and exposure to staff, Cerrobend collimators are recommended above copper alternatives for electron FLASH research. This platform enables high-throughput animal irradiation, which is preferred for experiments using a large number of animals, which are required to effectively determine UHDR treatment efficacies.


Assuntos
Cobre , Elétrons , Humanos , Animais , Camundongos , Aceleradores de Partículas , Pulmão , Água , Dosagem Radioterapêutica , Radiometria
2.
Med Phys ; 50(11): 7245-7251, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37334736

RESUMO

BACKGROUND: Hydrated electrons, which are short-lived products of radiolysis in water, increase the optical absorption of water, providing a pathway toward near-tissue-equivalent clinical radiation dosimeters. This has been demonstrated in high-dose-per-pulse radiochemistry research, but, owing to the weak absorption signal, its application in existing low-dose-per-pulse radiotherapy provided by clinical linear accelerators (linacs) has yet to be investigated. PURPOSE: The aims of this study were to measure the optical absorption associated with hydrated electrons produced by clinical linacs and to assess the suitability of the technique for radiotherapy (⩽ 1 cGy per pulse) applications. METHODS: 40 mW of 660-nm laser light was sent five passes through deionized water contained in a 10 × 4 × $\times 4\times$ 2 cm3 glass-walled cavity by using four broadband dielectric mirrors, two on each side of the cavity. The light was collected with a biased silicon photodetector. The water cavity was then irradiated by a Varian TrueBeam linac with both photon (10 MV FFF, 6 MV FFF, 6 MV) and electron beams (6 MeV) while monitoring the transmitted laser power for absorption transients. Radiochromic EBT3 film measurements were also performed for comparison. RESULTS: Examination of the absorbance profiles showed clear absorption changes in the water when radiation pulses were delivered. Both the amplitude and the decay time of the signal appeared consistent with the absorbed dose and the characteristics of the hydrated electrons. By using literature value for the hydrated electron radiation chemical yield (3.0±0.3), we inferred doses of 2.1±0.2 mGy (10 MV FFF), 1.3±0.1 mGy (6 MV FFF), 0.45±0.06 mGy (6 MV) for photons, and 0.47±0.05 mGy (6 MeV) for electrons, which differed from EBT3 film measurements by 0.6%, 0.8%, 10%, and 15.7%, respectively. The half-life of the hydrated electrons in the solution was ∼ 24 µ $\umu$ s. CONCLUSIONS: By measuring 660-nm laser light transmitted through a cm-scale, multi-pass water cavity, we observed absorption transients consistent with hydrated electrons generated by clinical linac radiation. The agreement between our inferred dose and EBT3 film measurements suggests this proof-of-concept system represents a viable pathway toward tissue-equivalent dosimeters for clinical radiotherapy applications.


Assuntos
Elétrons , Dosímetros de Radiação , Fótons/uso terapêutico , Imagens de Fantasmas , Aceleradores de Partículas , Água , Dosagem Radioterapêutica , Radiometria/métodos
3.
J Radiat Res ; 62(5): 833-840, 2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34247250

RESUMO

X-ray induced molecular luminescence (XML) is a phenomenon that can be utilized for clinical, deep-tissue functional imaging of tailored molecular probes. In this study, a survey of common or clinically approved fluorophores was carried out for their megavoltage X-ray induced excitation and emission characteristics. We find that direct scintillation effects and Cherenkov generation are two possible ways to cause these molecules' excitation. To distinguish the contributions of each excitation mechanism, we exploited the dependency of Cherenkov radiation yield on X-ray energy. The probes were irradiated by constant dose of 6 MV and 18 MV X-ray radiation, and their relative emission intensities and spectra were quantified for each X-ray energy pair. From the ratios of XML, yield for 6 MV and 18 MV irradiation we found that the Cherenkov radiation dominated as an excitation mechanism, except for aluminum phthalocyanine, which exhibited substantial scintillation. The highest emission yields were detected from fluorescein, proflavin and aluminum phthalocyanine, in that order. XML yield was found to be affected by the emission quantum yield, overlap of the fluorescence excitation and Cherenkov emission spectra, scintillation yield. Considering all these factors and XML emission spectrum respective to tissue optical window, aluminum phthalocyanine offers the best XML yield for deep tissue use, while fluorescein and proflavine are most useful for subcutaneous or superficial use.


Assuntos
Corantes Fluorescentes/efeitos da radiação , Luminescência , Avaliação Pré-Clínica de Medicamentos , Desenho de Equipamento , Fluoresceína/efeitos da radiação , Humanos , Indóis/efeitos da radiação , Isoindóis/efeitos da radiação , Azul de Metileno/efeitos da radiação , Compostos Organometálicos/efeitos da radiação , Aceleradores de Partículas , Proflavina/efeitos da radiação , Protoporfirinas/efeitos da radiação , Solventes , Espectrometria de Fluorescência , Verteporfina/efeitos da radiação , Raios X
4.
Radiat Oncol ; 16(1): 139, 2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34321029

RESUMO

BACKGROUND: Mega-voltage fan-beam Computed Tomography (MV-FBCT) holds potential in accurate determination of relative electron density (RED) and proton stopping power ratio (SPR) but is not widely available. OBJECTIVE: To demonstrate the feasibility of MV-FBCT using a medical linear accelerator (LINAC) with a 2.5 MV imaging beam, an electronic portal imaging device (EPID) and multileaf collimators (MLCs). METHODS: MLCs were used to collimate MV beam along z direction to enable a 1 cm width fan-beam. Projection data were acquired within one gantry rotation and preprocessed with in-house developed artifact correction algorithms before the reconstruction. MV-FBCT data were acquired at two dose levels: 30 and 60 monitor units (MUs). A Catphan 604 phantom was used to evaluate basic image quality. A head-sized CIRS phantom with three configurations of tissue-mimicking inserts was scanned and MV-FBCT Hounsfield unit (HU) to RED calibration was established for each insert configuration using linear regression. The determination coefficient ([Formula: see text]) was used to gauge the accuracy of HU-RED calibration. Results were compared with baseline single-energy kilo-voltage treatment planning CT (TP-CT) HU-RED calibration which represented the current standard clinical practice. RESULTS: The in-house artifact correction algorithms effectively suppressed ring artifact, cupping artifact, and CT number bias in MV-FBCT. Compared to TP-CT, MV-FBCT was able to improve the prediction accuracy of the HU-RED calibration curve for all three configurations of insert materials, with [Formula: see text] > 0.9994 and [Formula: see text] < 0.9990 for MV-FBCT and TP-CT HU-RED calibration curves of soft-tissue inserts, respectively. The measured mean CT numbers of blood-iodine mixture inserts in TP-CT drastically deviated from the fitted values but not in MV-FBCT. Reducing the radiation level from 60 to 30 MU did not decrease the prediction accuracy of the MV-FBCT HU-RED calibration curve. CONCLUSION: We demonstrated the feasibility of MV-FBCT and its potential in providing more accurate RED estimation.


Assuntos
Algoritmos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Calibragem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica
5.
Radiol Oncol ; 54(4): 495-504, 2020 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-32936784

RESUMO

Introduction Advanced, Monte Carlo (MC) based dose calculation algorithms, determine absorbed dose as dose to medium-in-medium (Dm,m) or dose to water-in-medium (Dw,m). Some earlier studies identified the differences in the absorbed doses related to the calculation mode, especially in the bone density equivalent (BDE) media. Since the calculation algorithms built in the treatment planning systems (TPS) should be dosimetrically verified before their use, we analyzed dose differences between two calculation modes for the Elekta Monaco TPS. We compared them with experimentally determined values, aiming to define a supplement to the existing TPS verification methodology. Materials and methods In our study, we used a 6 MV photon beam from a linear accelerator. To evaluate the accuracy of the TPS calculation approaches, measurements with a Farmer type chamber in a semi-anthropomorphic phantom were compared to those obtained by two calculation options. The comparison was made for three parts of the phantom having different densities, with a focus on the BDE part. Results Measured and calculated doses were in agreement for water and lung equivalent density materials, regardless of the calculation mode. However, in the BDE part of the phantom, mean dose differences between the calculation options ranged from 5.7 to 8.3%, depending on the method used. In the BDE part of the phantom, neither of the two calculation options were consistent with experimentally determined absorbed doses. Conclusions Based on our findings, we proposed a supplement to the current methodology for the verification of commercial MC based TPS by performing additional measurements in BDE material.


Assuntos
Densidade Óssea , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Modelos Anatômicos , Aceleradores de Partículas , Fótons
6.
Int J Radiat Oncol Biol Phys ; 108(4): 851-855, 2020 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-32665111

RESUMO

Oman is a high-income Middle Eastern country. Over the past 50 years, the country's health care system has undergone revolutionary changes to meet the health care needs of its population, driven by high oil and gas revenues. It currently has a very efficient universal health care system. There are 2 linear accelerators in the country and 6 radiation oncologists. A new cancer research center is currently under construction. The major challenge that could affect the delivery of radiation therapy in the future is sustenance of the health care achievements in view of a growing population and the reliance on public funding for health care delivery.


Assuntos
Atenção à Saúde/economia , Previsões , Radio-Oncologistas/provisão & distribuição , Radioterapia (Especialidade)/tendências , Institutos de Câncer , Educação Médica , Arquitetura de Instituições de Saúde , Feminino , Humanos , Masculino , Programas Nacionais de Saúde/classificação , Programas Nacionais de Saúde/organização & administração , Neoplasias/epidemiologia , Omã/epidemiologia , Aceleradores de Partículas/provisão & distribuição , Radioterapia (Especialidade)/economia , Radioterapia (Especialidade)/instrumentação , Radioterapia (Especialidade)/organização & administração , Sistema de Registros , Distribuição por Sexo , Assistência de Saúde Universal
7.
Strahlenther Onkol ; 196(7): 608-616, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32303782

RESUMO

INTRODUCTION: Stereotactic body radiation therapy (SBRT) is considered an effective and safe treatment in patients with low- and intermediate-risk prostate cancer (PC). However, due to a lack of long-term follow-up and late toxicity data, this treatment is not universally accepted. The present study aimed to evaluate outcome and early and late toxicity in a cohort of patients with low- and intermediate-risk PC treated prospectively with linear accelerator (linac)-based SBRT. PATIENTS AND METHODS: Patients with low- or intermediate-risk (NCCN criteria) PC were included. All patients received linac-based SBRT to 35 Gy in 5 fractions delivered on alternate days. Endpoints were toxicity, biochemical relapse-free survival (BRFS), metastatic progression-free survival (mPFS), and overall survival (OS). RESULTS: From 2012 to 2018, 178 patients were treated. Median baseline prostate-specific antigen (iPSA) was 6.37 ng/ml (range 1.78-20). Previous transurethral resection of the prostate (TURP) was present in 23 (12.9%) patients. Median follow-up was 58.9 months (range 9.7-89.9). BRFS rates at 1, 3, and 5 years were 98.3 (95% confidence interval, CI, 94.7-99.4%), 94.4 (95%CI 89.4-97), and 91.6% (95%CI 85.4-95.2), respectively. In univariate analysis, performance status (PS), iPSA, and nadir PSA (nPSA) were correlated with BRFS. In multivariable analysis iPSA and nPSA remained significant. BRFS rates at 5 years were 94.9% (95%CI 86.8-98) for International Society of Urological Pathology (ISUP) grade group 1, 93.2% (95%CI 80.5-97.7) for ISUP group 2, and 74.8% (95%CI 47.1-89.5) for ISUP group 3. At 1, 3, and 5 years, mPFS rates were 98.8 (95%CI 95.5-99.7), 96.2 (95%CI 91.9-98.3), and 92.9% (95%CI 87.2-96.2), respectively; OS rates were 100, 97.2 (95%CI 92.9-98.9), and 95.1% (95%CI 90-97.6), respectively. One (0.56%) case of grade 3 acute genitourinary (GU), one case of acute gastrointestinal (GI), and one case of grade 3 late GU toxicity were observed. GI toxicity positively correlated with prostate volume. CONCLUSION: At long-term follow-up, linac-based SBRT continues to be a valid option for the management localized PC. Biochemical control remains high at 5 years, albeit with some concerns regarding the optimal schedule for unfavorable intermediate-risk PC. Considering the excellent prognosis, patient selection is crucial for prevention of severe late toxicity.


Assuntos
Adenocarcinoma/radioterapia , Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Adenocarcinoma/sangue , Adenocarcinoma/patologia , Adenocarcinoma/cirurgia , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Fracionamento da Dose de Radiação , Gastroenteropatias/etiologia , Ablação por Ultrassom Focalizado de Alta Intensidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Aceleradores de Partículas , Intervalo Livre de Progressão , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Radiocirurgia/efeitos adversos , Fatores de Risco , Ressecção Transuretral da Próstata , Resultado do Tratamento , Carga Tumoral , Transtornos Urinários/etiologia
9.
Phys Med Biol ; 65(7): 075003, 2020 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-31995531

RESUMO

The beam quality correction factor, [Formula: see text], which corrects for the difference in the ionization chamber response between the reference and clinical beam quality, is an integral part of radiation therapy dosimetry. The uncertainty of [Formula: see text] is one of the most significant sources of uncertainty in the dose determination. To improve the accuracy of available [Formula: see text] data, four partners calculated [Formula: see text] factors for 10 ionization chamber models in linear accelerator beams with accelerator voltages ranging from 6 MV to 25 MV, including flattening-filter-free (FFF) beams. The software used in the calculations were EGSnrc and PENELOPE, and the ICRU report 90 cross section data for water and graphite were included in the simulations. Volume averaging correction factors were calculated to correct for the dose averaging in the chamber cavities. A comparison calculation between partners showed a good agreement, as did comparison with literature. The [Formula: see text] values from TRS-398 were higher than our values for each chamber where data was available. The [Formula: see text] values for the FFF beams did not follow the same [Formula: see text], [Formula: see text] relation as beams with flattening filter (values for 10 MV FFF beams were below fits made to other data on average by 0.3%), although our FFF sources were only for Varian linacs.


Assuntos
Fótons/uso terapêutico , Radiometria/instrumentação , Algoritmos , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Eficiência Biológica Relativa , Incerteza , Água
10.
Med Phys ; 47(3): 1291-1304, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31834640

RESUMO

PURPOSE: In this work, the fabrication, operation, and evaluation of a probe-format graphite calorimeter - herein referred to as Aerrow - as an absolute clinical dosimeter of high-energy photon beams while in the presence of a B = 1.5 T magnetic field is described. Comparable to a cylindrical ionization chamber (IC) in terms of utility and usability, Aerrow has been developed for the purpose of accurately measuring absorbed dose to water in the clinic with a minimum disruption to the existing clinical workflow. To our knowledge, this is the first reported application of graphite calorimetry to magnetic resonance imaging (MRI)-guided radiotherapy. METHODS: Based on a previously numerically optimized and experimentally validated design, an Aerrow prototype capable of isothermal operation was constructed in-house. Graphite-to-water dose conversions as well as magnetic field perturbation factors were calculated using Monte Carlo, while heat transfer and mass impurity corrections and uncertainties were assessed analytically. Reference dose measurements were performed in the absence and presence of a B = 1.5 T magnetic field using Aerrow in the 7 MV FFF photon beam of an Elekta MRI-linac and were directly compared to the results obtained using two calibrated reference-class IC types. The feasibility of performing solid phantom-based dosimetry with Aerrow and the possible influence of clearance gaps is also investigated by performing reference-type dosimetry measurements for multiple rotational positions of the detector and comparing the results to those obtained in water. RESULTS: In the absence of the B-field, as well as in the parallel orientation while in the presence of the B-field, the absorbed dose to water measured using Aerrow was found to agree within combined uncertainties with those derived from TG-51 using calibrated reference-class ICs. Statistically significant differences on the order of (2-4)%, however, were observed when measuring absorbed dose to water using the ICs in the perpendicular orientation in the presence of the B-field. Aerrow had a peak-to-peak response of about 0.5% when rotated within the solid phantom regardless of whether the B-field was present or not. CONCLUSIONS: This work describes the successful use of Aerrow as a straightforward means of measuring absolute dose to water for large high-energy photon fields in the presence of a 1.5 T B-field to a greater accuracy than currently achievable with ICs. The detector-phantom air gap does not appear to significantly influence the response of Aerrow in absolute terms, nor does it contribute to its rotational dependence. This work suggests that the accurate use of solid phantoms for absolute point dose measurement is possible with Aerrow.


Assuntos
Calorimetria/instrumentação , Imageamento por Ressonância Magnética , Aceleradores de Partículas , Imagens de Fantasmas , Fótons/uso terapêutico , Radioterapia Guiada por Imagem/instrumentação , Água , Temperatura Alta , Radiometria , Incerteza
11.
Int J Clin Oncol ; 25(1): 43-50, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31168726

RESUMO

Boron neutron capture therapy (BNCT) has a unique property of tumor-cell-selective heavy-particle irradiation. BNCT can form large dose gradients between cancer cells and normal cells, even if the two types of cells are mingled at the tumor margin. This property makes it possible for BNCT to be used for pre-irradiated locally recurrent tumors. Shallow-seated, locally recurrent lesions have been treated with BNCT because of the poor penetration of neutrons in the human body. BNCT has been used in clinical studies for recurrent malignant gliomas and head and neck cancers using neutron beams derived from research reactors, although further investigation is warranted because of the small number of patients. In the latter part of this review, the development of accelerator-based neutron sources is described. BNCT for common cancers will become available at medical institutes that are equipped with an accelerator-based BNCT system. Multiple metastatic lung tumors have been investigated as one of the new treatment candidates because BNCT can deliver curative doses of radiation to the tumors while sparing normal lung tissue. Further basic and clinical studies are needed to move toward an era of accelerator-based BNCT when more patients suffering from refractory cancers will be treated.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Nêutrons/uso terapêutico , Aceleradores de Partículas/instrumentação , Humanos , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/radioterapia , Neoplasias/patologia , Neoplasias/radioterapia
12.
Phys Med ; 61: 94-102, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31151586

RESUMO

PURPOSE: To assess the capability of different types of detectors to measure relative output factors (OF) at high dose per pulse by comparison with alanine dosimeters, which are independent of dose rate. METHODS: Measurements were made in 9 MeV and 7 MeV electron beams produced by a Novac7 accelerator for intraoperative radiotherapy. Applicators with diameter of 10-7-6-5 and 4 cm were used. The dose per pulse varied from about 30 mGy, for the 10 cm reference applicator, to about 70 mGy, for the 4 cm applicator. Five types of plane-parallel ionization chambers (PTW Advanced Markus, Markus and Roos, IBA PPC40 and PPC05), two types of silicon diodes (PTW 60017 and IBA EFD3G) and a PTW 60019 microDiamond were considered. For the ionization chambers, correction factors for ion recombination effects were determined for each applicator using a modified two-voltage-analysis method that includes the free-electron component. RESULTS: Reference OF values were determined by alanine dosimeters with a standard combined uncertainty of 0.8%. Deviations from the reference OFs were generally within 1.5% for all the detectors, hence within the 95% confidence interval of alanine measurements. Larger deviations of up to about 2% obtained in a few cases are consistent with a 0.7% long-term reproducibility of OF measurements. CONCLUSIONS: Comparison with alanine measurements demonstrated that all the detectors considered in this work can be used to measure OFs in high dose-per-pulse electron beams with an accuracy better than 2%, provided that appropriate corrections for ion recombination effects are applied when using ionization chambers.


Assuntos
Elétrons/uso terapêutico , Doses de Radiação , Aceleradores de Partículas , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
13.
J Appl Clin Med Phys ; 20(6): 178-183, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30884060

RESUMO

PURPOSE: The aim of the current study was to evaluate the backscatter dose and energy spectrum from the Lipiodol with flattening filter (FF) and flattening filter-free (FFF) beams. Moreover, the backscatter range, that was defined as the backscatter distance (BD) are revealed. METHODS: 6 MVX FF and FFF beams were delivered by TrueBeam. Two dose calculation methods with Monte Carlo calculation were used with a virtual phantom in which the Lipiodol (3 × 3 × 3 cm3 ) was located at a depth of 5.0 cm in a water-equivalent phantom (20 × 20 × 20 cm3 ). The first dose calculation was an analysis of the dose and energy spectrum with the complete scattering of photons and electrons, and the other was a specified dose analysis only with scattering from a specified region. The specified dose analysis was divided into a scattering of primary photons and a scattering of electrons. RESULTS: The lower-energy photons contributed to the backscatter, while the high-energy photons contributed the difference of the backscatter dose between the FF and FFF beams. Although the difference in the dose from the scattered electrons between the FF and FFF beams was within 1%, the difference of the dose from the scattered photons between the FF and FFF beams was 5.4% at a depth of 4.98 cm. CONCLUSIONS: The backscatter range from the Lipiodol was within 3 mm and depended on the Compton scatter from the primary photons. The backscatter dose from the Lipiodol can be useful in clinical applications in cases where the backscatter region is located within a tumor.


Assuntos
Elétrons , Óleo Etiodado/química , Método de Monte Carlo , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Fótons , Humanos , Doses de Radiação
14.
J Nucl Med ; 60(3): 424-428, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30237213

RESUMO

15O (half-life, 122 s) is a useful radionuclide for PET applications. Current production of 15O typically makes use of the 14N(d,n)15O, 15N(p,n)15O, or 16O(p,pn)15O reactions using an accelerator. A novel approach for the production of 15O is via the 16O(γ,n)15O reaction using an electron linear accelerator. Photonuclear reactions using an electron linear accelerator may allow for feasible and economical production of 15O compared with the current methods. Methods: In this work, experiments using a repurposed Clinac were conducted using oxygen-containing alumina as a target material to study the production rate of 15O. Additional studies were conducted using a water target cell. Simulations using Geant4 were conducted to predict the activity and power dissipation in the target. Results: Bremsstrahlung radiation from the electron beam, and consequently 15O production via photonuclear reactions, is enhanced when a high-Z material, tungsten, is placed in front of the target. The alumina irradiations provided preliminary data to optimize the beam parameters and target configuration. The optimal thickness of tungsten was 1.4 mm for both the simulated and the measured studies of alumina. Simulations of irradiated water targets showed that tungsten thicker than 1.4 mm resulted in fewer photons available to activate the water; thus, a higher current was required to achieve a fixed dose. Alternatively, for a constant tungsten thickness, more power was deposited in the target with increasing beam energy, requiring a lower current to achieve a fixed dose. Actual irradiations of a water target yielded a quantity of 15O in the water that was consistent with expectations based on irradiations of alumina. Conclusion: Several parameters should be considered regarding the photonuclear production of 15O for an average patient dose of 1,850 MBq (50 mCi) in 10 mL. This work illustrates a variety of machine parameters capable of achieving a reasonable patient dose. Our simulations show that the power deposited in the target for these parameters is less than that in commercially operated cyclotron targets for the production of 18F. Thus, this work demonstrates that the photonuclear production of 15O may be a new production path for this useful radionuclide.


Assuntos
Radioisótopos de Oxigênio/química , Oxigênio/química , Radioquímica/métodos , Óxido de Alumínio/química , Aceleradores de Partículas , Radioquímica/instrumentação , Água/química
15.
Appl Radiat Isot ; 140: 121-125, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30015040

RESUMO

Fuel configurations for a subcritical neutron multiplier, which was embedded in a beam-shaping assembly and irradiated by electrons from a linear accelerator, were examined to maximize the production of the epithermal neutron flux for boron neutron capture therapy. The epithermal neutron flux at the treatment position increased as the area per uranium fuel plate increased and was estimated to be 2 × 109 cm-2 s-1 when the subcritical neutron multiplier was irradiated by a 4.4 kW (0.22 mA) beam of 20 MeV electrons.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Desenho de Equipamento , Nêutrons Rápidos , Humanos , Método de Monte Carlo , Neoplasias/radioterapia , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Urânio
16.
Med Phys ; 45(7): 3315-3320, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29672860

RESUMO

PURPOSE: Cherenkov light during MV radiotherapy has recently found imaging and therapeutic applications but is challenged by relatively low fluence. Our purpose is to investigate the feasibility of increasing Cherenkov light production during MV radiotherapy by increasing photon energy and applying specialized beam-hardening filtration. METHODS: GAMOS 5.0.0, a GEANT4-based framework for Monte Carlo simulations, was used to model standard clinical linear accelerator primary photon beams. The photon source was incident upon a 17.8 cm3 cubic water phantom with a 94 cm source to surface distance. Dose and Cherenkov production was determined at depths of 3-9 cm. Filtration was simulated 15 cm below the photon beam source. Filter materials included aluminum, iron, and copper with thicknesses of 2-20 cm. Histories used depended on the level of attenuation from the filter, ranging from 100 million to 2 billion. Comparing average dose per history also allowed for evaluation of dose-rate reduction for different filters. RESULTS: Overall, increasing photon beam energy is more effective at improving Cherenkov production per unit dose than is filtration, with a standard 18 MV beam yielding 3.3-4.0× more photons than 6 MV. Introducing an aluminum filter into an unfiltered 2400 cGy/min 10 MV beam increases the Cherenkov production by 1.6-1.7×, while maintaining a clinical dose rate of 300 cGy/min, compared to increases of ~1.5× for iron and copper. Aluminum was also more effective than the standard flattening filter, with the increase over the unfiltered beam being 1.4-1.5× (maintaining 600 cGy/min dose rate) vs 1.3-1.4× for the standard flattening filter. Applying a 10 cm aluminum filter to a standard 18 MV, photon beam increased the Cherenkov production per unit dose to 3.9-4.3× beyond that of 6 MV (vs 3.3-4.0× for 18 MV with no aluminum filter). CONCLUSIONS: Through a combination of increasing photon energy and applying specialized beam-hardening filtration, the amount of Cherenkov photons per unit radiotherapy dose can be increased substantially.


Assuntos
Aceleradores de Partículas , Fótons/uso terapêutico , Radioterapia/instrumentação , Radioterapia/métodos , Alumínio , Simulação por Computador , Cobre , Humanos , Ferro , Método de Monte Carlo , Imagens de Fantasmas , Água
17.
J Appl Clin Med Phys ; 19(2): 211-217, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29450985

RESUMO

PURPOSE: Lipiodol, which was used in transcatheter arterial chemoembolization before liver stereotactic body radiation therapy (SBRT), remains in SBRT. Previous we reported the dose enhancement in Lipiodol using 10 MV (10×) FFF beam. In this study, we compared the dose enhancement in Lipiodol and evaluated the probability of electron generation (PEG) for the dose enhancement using flattening filter (FF) and flattening filter free (FFF) beams. METHODS: FF and FFF for 6 MV (6×) and 10× beams were delivered by TrueBeam. The dose enhancement factor (DEF), energy spectrum, and PEG was calculated using Monte Carlo (MC) code BEAMnrc and heavy ion transport code system (PHITS). RESULTS: DEFs for FF and FFF 6× beams were 7.0% and 17.0% at the center of Lipiodol (depth, 6.5 cm). DEFs for FF and FFF 10× beams were 8.2% and 10.5% at the center of Lipiodol. Spectral analysis revealed that the FFF beams contained more low-energy (0-0.3 MeV) electrons than the FF beams, and the FF beams contained more high-energy (>0.3 MeV) electrons than the FFF beams in Lipiodol. The difference between FFF and FF beam DEFs was larger for 6× than for 10×. This occurred because the 10× beams contained more high-energy electrons. The PEGs for photoelectric absorption and Compton scattering for the FFF beams were higher than those for the FF beams. The PEG for the photoelectric absorption was higher than that for Compton scattering. CONCLUSIONS: FFF beam contained more low-energy photons and it contributed to the dose enhancement. Energy spectra and PEGs are useful for analyzing the mechanisms of dose enhancement.


Assuntos
Elétrons , Óleo Etiodado/administração & dosagem , Neoplasias/cirurgia , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Radiometria/métodos , Dosagem Radioterapêutica
18.
Phys Med ; 45: 106-116, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29472074

RESUMO

PURPOSE: To investigate the feasibility of using the ratio of dose-area product at 20 cm and 10 cm water depths (DAPR20,10) as a beam quality specifier for radiotherapy photon beams with field diameter below 2 cm. METHODS: Dose-area product was determined as the integral of absorbed dose to water (Dw) over a surface larger than the beam size. 6 MV and 10 MV photon beams with field diameters from 0.75 cm to 2 cm were considered. Monte Carlo (MC) simulations were performed to calculate energy-dependent dosimetric parameters and to study the DAPR20,10 properties. Aspects relevant to DAPR20,10 measurement were explored using large-area plane-parallel ionization chambers with different diameters. RESULTS: DAPR20,10 was nearly independent of field size in line with the small differences among the corresponding mean beam energies. Both MC and experimental results showed a dependence of DAPR20,10 on the measurement setup and the surface over which Dw is integrated. For a given setup, DAPR20,10 values obtained using ionization chambers with different air-cavity diameters agreed with one another within 0.4%, after the application of MC correction factors accounting for effects due to the chamber size. DAPR20,10 differences among the small field sizes were within 1% and sensitivity to the beam energy resulted similar to that of established beam quality specifiers based on the point measurement of Dw. CONCLUSIONS: For a specific measurement setup and integration area, DAPR20,10 proved suitable to specify the beam quality of small photon beams for the selection of energy-dependent dosimetric parameters.


Assuntos
Fótons/uso terapêutico , Radiometria/métodos , Dosagem Radioterapêutica , Ar , Radioisótopos de Cobalto/uso terapêutico , Simulação por Computador , Método de Monte Carlo , Aceleradores de Partículas , Incerteza , Água
19.
J Neurosurg ; 128(1): 215-221, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28298033

RESUMO

Essential tremor and Parkinson's disease-associated tremor are extremely prevalent within the field of movement disorders. The ventral intermediate (VIM) nucleus of the thalamus has been commonly used as both a neuromodulatory and neuroablative target for the treatment of these forms of tremor. With both deep brain stimulation and Gamma Knife radiosurgery, there is an abundance of literature regarding the surgical planning, targeting, and outcomes of these methodologies. To date, there have been no reports of frameless, linear accelerator (LINAC)-based thalomotomies for tremor. The authors report the case of a patient with tremor-dominant Parkinson's disease, with poor tremor improvement with medication, who was offered LINAC-based thalamotomy. High-resolution 0.9-mm isotropic MR images were obtained, and simulation was performed via CT with 1.5-mm contiguous slices. The VIM thalamic nucleus was determined using diffusion tensor imaging (DTI)-based segmentation on FSL using probabilistic tractography. The supplemental motor and premotor areas were the cortical target masks. The authors centered their isocenter within the region of the DTI-determined target and treated the patient with 140 Gy in a single fraction. The DTI-determined target had coordinates of 14.2 mm lateral and 8.36 mm anterior to the posterior commissure (PC), and 3 mm superior to the anterior commissure (AC)-PC line, which differed by 3.30 mm from the original target determined by anatomical considerations (15.5 mm lateral and 7 mm anterior to the PC, and 0 mm superior to the AC-PC line). There was faint radiographic evidence of lesioning at the 3-month follow-up within the target zone, which continued to consolidate on subsequent scans. The patient experienced continued right upper-extremity resting tremor improvement starting at 10 months until it was completely resolved at 22 months of follow-up. Frameless LINAC-based thalamotomy guided by DTI-based thalamic segmentation is a feasible method for achieving radiosurgical lesions of the VIM thalamus to treat tremor.


Assuntos
Imagem de Tensor de Difusão , Radiocirurgia , Radioterapia Guiada por Imagem , Tremor/diagnóstico por imagem , Tremor/radioterapia , Idoso de 80 Anos ou mais , Humanos , Imagem por Ressonância Magnética Intervencionista , Masculino , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/fisiopatologia , Doença de Parkinson/radioterapia , Aceleradores de Partículas , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Tálamo , Tremor/fisiopatologia
20.
Clin Transl Oncol ; 20(3): 402-410, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28776310

RESUMO

PURPOSE: Planning for radiation oncology requires reliable estimates of both demand for radiotherapy and availability of technological resources. This study compares radiotherapy resources in the 17 regions of the decentralised Spanish National Health System (SNHS). MATERIALS AND METHODS: The Sociedad Española de Oncología Radioterápica (SEOR) performed a cross-sectional survey of all Spanish radiation oncology services (ROS) in 2015. We collected data on SNHS radiotherapy units, recording the year of installation, specific features of linear accelerators (LINACs) and other treatment units, and radiotherapeutic techniques implemented by region. Any machine over 10 years old or lacking a multileaf collimator or portal imaging system was considered obsolete. We performed a k-means clustering analysis using the Hartigan-Wong method to test associations between the gross domestic regional product (GDRP), the number of LINACs per million population and the percentage of LINACs over 10 years old. RESULTS: The SNHS controls 72 (61%) of the 118 Spanish ROS and has 180 LINACs, or 72.5% of the total public and private resources. The mean rate of LINACs per million population is 3.9 for public ROS, and 42% (n = 75) of the public accelerators were obsolete in 2015: 61 due to age and 14 due to technological capability. There was considerable regional variation in terms of the number and technological capacity of radiotherapy units; correlation between GRDP and resource availability was moderate. CONCLUSION: Despite improvements, new investments are still needed to replace obsolete units and increase access to modern radiotherapy. Regular analysis of ROS in each Spanish region is the only strategy for monitoring progress in radiotherapy capacity.


Assuntos
Aceleradores de Partículas/provisão & distribuição , Radioterapia (Especialidade)/instrumentação , Radioterapia/instrumentação , Humanos , Programas Nacionais de Saúde , Espanha