1.
Undersea Hyperb Med ; 47(2): 229-234, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32574439

RESUMO

Introduction: Health care workers are vulnerable to workplace violence, including active shooter incidents. Little is known about how firearms could damage monoplace chamber acrylic and whether a breached pressurized chamber presents additional threat to the patient or bystanders. Methods: In a remote area where firearm discharge is permitted, we tested the durability of sections of monoplace hyperbaric chamber acrylic under various firearm discharges. Firearms were discharged at acrylic sections from a distance of 17 feet at 45 degrees and 10 degrees from perpendicular while wearing protective gear. Firearm calibers ranged from .22 caliber handgun to 5.56 mm AR-15 rifle. We also conducted similar testing on a monoplace hyperbaric chamber pressurized with >99% oxygen to a differential pressure of 14.7 psig (2.0 atmospheres absolute at sea level). Handguns were remotely fired at a distance of 12 feet from the chamber (30 degrees from perpendicular), while the rifles were fired at a distance of 60 feet from the chamber. Result: Higher-caliber handguns penetrated or fractured the acrylic sections only after multiple shots. The tested rifles caused full-thickness penetration and fracture with a single shot. However, the pressurized monoplace hyperbaric chamber required two shots from the AR-15 rifle, separated by approximately 60 mm, to penetrate the acrylic, resulting in rapid depressurization. The chamber otherwise remained intact, with no explosion or conflagration observed. Conclusion: An intact or pressurized chamber performs differently than stand-alone acrylic sections under firearms testing. In a worst-case active shooter scenario, the pressurized monoplace chamber tested posed no additional threat to bystanders beyond the significant risk of ricochet.


Assuntos
Análise de Falha de Equipamento/métodos , Armas de Fogo , Oxigenoterapia Hiperbárica
2.
BMC Pediatr ; 19(1): 188, 2019 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-31176379

RESUMO

BACKGROUND: In Indonesia, the burden of severe hyperbilirubinemia is higher compared to other countries. Whether this is related to ineffective phototherapy (PT) is unknown. The aim of this study is to investigate the performance of phototherapy devices in hospitals on Java, Indonesia. METHODS: In 17 hospitals we measured 77 combinations of 20 different phototherapy devices, with and without curtains drawn around the incubator/crib. With a model to mimic the silhouette of an infant, we measured the irradiance levels with an Ohmeda BiliBlanket Meter II, recorded the distance between device and model, and compared these to manufacturers' specifications. RESULTS: In nine hospitals the irradiance levels were less than required for standard PT: < 10 µW/cm2/nm and in eight hospitals irradiance failed to reach the levels for intensive phototherapy: 30 µW/cm2/nm. Three hospitals provided very high irradiance levels: > 50 µW/cm2/nm. Half of the distances between device and model were greater than recommended. Distance was inversely correlated with irradiance levels (R2 = 0.1838; P < 0.05). The effect of curtains on irradiance levels was highly variable, ranging from - 6.15 to + 15.4 µW/cm2/nm, with a mean difference (SD) of 1.82 (3.81) µW/cm2/nm (P = 0.486). CONCLUSIONS: In half of the hospitals that we studied on Java the levels of irradiance are too low and, in some cases, too high. Given the risks of insufficient phototherapy or adverse effects, we recommend that manufacturers provide radiometers so hospitals can optimize the performance of their phototherapy devices.


Assuntos
Hiperbilirrubinemia Neonatal/terapia , Luminescência , Fototerapia/instrumentação , Bilirrubina/sangue , Análise de Falha de Equipamento/métodos , Fluorescência , Humanos , Hiperbilirrubinemia Neonatal/sangue , Indonésia , Recém-Nascido , Decoração de Interiores e Mobiliário
3.
Eur Spine J ; 27(8): 1964-1971, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29948322

RESUMO

PURPOSE: Cement augmentation of pedicle screws is known to increase their mechanical strength. Aim was to evaluate the impact of cement augmentation on pedicle screw fatigue strength in dependence of the bone mineral density (BMD). METHODS: Twenty-one human L2 vertebral bodies from donors between 19 and 96 years of age were used for in vitro experiments. BMD was measured using quantitative computed tomography (QCT). Two pedicle screws were inserted in each specimen and unilaterally augmented with bone cement. Fatigue testing was performed using a cranio-caudal sinusoidal, cyclic load (0.5 Hz) with increasing compression force (100 N + 0.1 N/cycles). Results were evaluated for the BMD groups: normal: BMD > 120 mg/cm3, osteopenic: BMD 80-120 mg/cm3, and osteoporotic: BMD < 80 mg/cm3 bone mass. RESULTS: There was a significant correlation between fatigue force and BMD for the non-augmented and augmented screws (non-augmented R2 = 0.839, p < 0.001; augmented R2 = 0.551, p < 0.001). There was a significantly increased fatigue strength of the augmented screws over the non-augmented screws in the osteoporotic group (p = 0.001), while the differences in the other groups were not significant (normal p = 0.818/osteopenic p = 0.132). CONCLUSIONS: The benefit of pedicle screw cement augmentation significantly depends on the bone mineral density and has the greatest extent of increased fatigue strength in osteoporotic vertebrae. Preoperative measurement of the BMD is strongly recommended to predict the benefit of augmentation and reinforce the decision for cement augmentation. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Cimentos Ósseos/uso terapêutico , Densidade Óssea/fisiologia , Vértebras Lombares/cirurgia , Osteoporose/fisiopatologia , Parafusos Pediculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Cadáver , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Osteoporose/diagnóstico por imagem , Falha de Prótese , Tomografia Computadorizada por Raios X , Adulto Jovem
4.
J Neural Eng ; 14(4): 046011, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28351998

RESUMO

OBJECTIVE: Performance of many dielectric coatings for neural electrodes degrades over time, contributing to loss of neural signals and evoked percepts. Studies using planar test substrates have found that a novel bilayer coating of atomic-layer deposited (ALD) Al2O3 and parylene C is a promising candidate for neural electrode applications, exhibiting superior stability to parylene C alone. However, initial results from bilayer encapsulation testing on non-planar devices have been less positive. Our aim was to evaluate ALD Al2O3-parylene C coatings using novel test paradigms, to rigorously evaluate dielectric coatings for neural electrode applications by incorporating neural electrode topography into test structure design. APPROACH: Five test devices incorporated three distinct topographical features common to neural electrodes, derived from the utah electrode array (UEA). Devices with bilayer (52 nm Al2O3 + 6 µm parylene C) were evaluated against parylene C controls (N ⩾ 6 per device type). Devices were aged in phosphate buffered saline at 67 °C for up to 311 d, and monitored through: (1) leakage current to evaluate encapsulation lifetimes (>1 nA during 5VDC bias indicated failure), and (2) wideband (1-105 Hz) impedance. MAIN RESULTS: Mean-times-to-failure (MTTFs) ranged from 12 to 506 d for bilayer-coated devices, versus 10 to >2310 d for controls. Statistical testing (log-rank test, α = 0.05) of failure rates gave mixed results but favored the control condition. After failure, impedance loss for bilayer devices continued for months and manifested across the entire spectrum, whereas the effect was self-limiting after several days, and restricted to frequencies <100 Hz for controls. These results correlated well with observations of UEAs encapsulated with bilayer and control films. SIGNIFICANCE: We observed encapsulation failure modes and behaviors comparable to neural electrode performance which were undetected in studies with planar test devices. We found the impact of parylene C defects to be exacerbated by ALD Al2O3, and conclude that inferior bilayer performance arises from degradation of ALD Al2O3 when directly exposed to saline. This is an important consideration, given that neural electrodes with bilayer coatings are expected to have ALD Al2O3 exposed at dielectric boundaries that delineate electrode sites. Process improvements and use of different inorganic coatings to decrease dissolution in physiological fluids may improve performance. Testing frameworks which take neural electrode complexities into account will be well suited to reliably evaluate such encapsulation schemes.


Assuntos
Óxido de Alumínio/normas , Materiais Revestidos Biocompatíveis/normas , Eletrodos Implantados/normas , Desenho de Equipamento/normas , Análise de Falha de Equipamento/métodos , Polímeros/normas , Xilenos/normas , Desenho de Equipamento/instrumentação , Microeletrodos/normas , Microeletrodos/tendências , Fatores de Tempo
5.
Strahlenther Onkol ; 193(5): 351-366, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28251250

RESUMO

Quality assurance (QA) guidelines are essential to provide uniform execution of clinical trials with uniform quality hyperthermia treatments. This document outlines the requirements for appropriate QA of all current superficial heating equipment including electromagnetic (radiative and capacitive), ultrasound, and infrared heating techniques. Detailed instructions are provided how to characterize and document the performance of these hyperthermia applicators in order to apply reproducible hyperthermia treatments of uniform high quality. Earlier documents used specific absorption rate (SAR) to define and characterize applicator performance. In these QA guidelines, temperature rise is the leading parameter for characterization of applicator performance. The intention of this approach is that characterization can be achieved with affordable equipment and easy-to-implement procedures. These characteristics are essential to establish for each individual applicator the specific maximum size and depth of tumors that can be heated adequately. The guidelines in this document are supplemented with a second set of guidelines focusing on the clinical application. Both sets of guidelines were developed by the European Society for Hyperthermic Oncology (ESHO) Technical Committee with participation of senior Society of Thermal Medicine (STM) members and members of the Atzelsberg Circle.


Assuntos
Ensaios Clínicos como Assunto/instrumentação , Ensaios Clínicos como Assunto/normas , Hipertermia Induzida/instrumentação , Hipertermia Induzida/normas , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde/normas , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/normas , Alemanha , Raios Infravermelhos , Internacionalidade , Micro-Ondas
6.
IEEE Trans Neural Syst Rehabil Eng ; 25(9): 1500-1509, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28114026

RESUMO

Lower extremity amputees suffer from mobility limitations which will result in a degradation of their quality of life. Wearable sensors are frequently used to assess spatio-temporal, kinematic and kinetic parameters providing the means to establish an interactive control of the amputee-prosthesis-environment system. Gait events and the gait phase detection of an amputee's locomotion are vital for controlling lower limb prosthetic devices. The paper presents an approach to real-time gait event detection for lower limb amputees using a wireless gyroscope attached to the shank when performing level ground and ramp activities. The results were validated using both healthy and amputee subjects and showed that the time differences in identifying Initial Contact (IC) and Toe Off (TO) events were larger in a transfemoral amputee when compared to the control subjects and a transtibial amputee (TTA). Overall, the time difference latency lies within a range of ±50 ms while the detection rate was 100% for all activities. Based on the validated results, the IC and TO events can be accurately detected using the proposed system in both control subjects and amputees when performing activities of daily living and can also be utilized in the clinical setup for rehabilitation and assessing the performance of lower limb prosthesis users.


Assuntos
Acelerometria/instrumentação , Membros Artificiais , Biorretroalimentação Psicológica/métodos , Transtornos Neurológicos da Marcha/reabilitação , Transtornos Neurológicos da Marcha/radioterapia , Marcha , Monitorização Ambulatorial/instrumentação , Adulto , Amputados/reabilitação , Biorretroalimentação Psicológica/instrumentação , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Masculino , Desempenho Psicomotor , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
7.
J Appl Biomater Funct Mater ; 14(4): e483-e489, 2016 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-27647391

RESUMO

BACKGROUND: Wear associated with hip components represents the main clinical problem in these patients, and it is important to develop new techniques for more accurate measurements of that wear. Currently, the gravimetric method is the gold standard for assessing mass measurements in preclinical evaluations. However, this method does not give other information such as volumetric loss or surface deviation. This work aimed to develop and validate a new technique to quantify ceramic volume loss from in vitro experiments using micro-computed tomography (micro-CT). METHODS: An alumina (BIOLOX® forte) femoral head (Ø = 28 mm) was used. Mass and volume loss were approached by gravimetric method (using a four decimal place digital microbalance) and by using Skyscan 1176 microtomographic system, respectively. RESULTS: Standard error and coefficient of variance of both gravimetric and experimental groups demonstrated the reliability of the micro-CT analysis technique. CONCLUSIONS: In conclusion, the findings of the present study suggest that this new protocol could be considered an important tool for wear assessment and that we have found a reliable metrological protocol for volumetric analysis of ceramic femoral head prostheses, demonstrating that the micro-CT technique can be an important tool for wear assessment.


Assuntos
Óxido de Alumínio , Cerâmica , Análise de Falha de Equipamento/métodos , Prótese de Quadril , Microtomografia por Raio-X/métodos , Humanos
8.
Diving Hyperb Med ; 46(1): 38-42, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27044461

RESUMO

BACKGROUND: It would be desirable to safely and continuously measure blood pressure noninvasively under hyperbaric and/or hyperoxic conditions, in order to explore haemodynamic responses in humans under these conditions. METHODS: A systematic analysis according to 'failure mode and effects analysis' principles of a commercially available beat-by-beat non-invasive blood pressure monitoring device was performed using specifications provided by the manufacturer. Possible failure modes related to pressure resistance and fire hazard in hyperbaric and oxygen-enriched environments were identified and the device modified accordingly to mitigate these risks. The modified device was compared to an unaltered device in five healthy volunteers under normobaric conditions. Measurements were then performed under hyperbaric conditions (243 kPa) in five healthy subjects. RESULTS: Modifications required included: 1) replacement of the carbon brush motorized pump by pressurized air connected through a balanced pressure valve; 2) modification of the 12V power supply connection in the multiplace hyperbaric chamber, and 3) replacement of gas-filled electrolytic capacitors by solid equivalents. There was concurrence between measurements under normobaric conditions, with no significant differences in blood pressure. Measurements under pressure were achieved without problems and matched intermittent measurement of brachial arterial pressure. CONCLUSION: The modified system provides safe, stable, continuous non-invasive blood pressure trends under both normobaric and hyperbaric conditions.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Pressão Sanguínea/fisiologia , Oxigenoterapia Hiperbárica , Pressão Atmosférica , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Frequência Cardíaca/fisiologia , Humanos , Pletismografia/instrumentação , Reprodutibilidade dos Testes
9.
J Biomed Mater Res B Appl Biomater ; 101(8): 1456-62, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23744622

RESUMO

Further development of ceramic materials for total hip replacement aim to increase fracture toughness and further reduce the incidence of bearing fracture. Edge loading due to translational mal positioning (microseparation) has replicated stripe wear, wear rates, and bimodal wear debris observed on retrievals. This method has replicated the fracture of early zirconia ceramic-on-ceramic bearings. This has shown the necessity of introducing microseparation conditions to the gait cycle when assessing the tribological performance of new hip replacement bearings. Two novel ceramic matrix composite materials, zirconia-toughened alumina (ZTA) and alumina-toughened zirconia (ATZ), were developed by Mathys Orthopädie GmbH. In this study, ATZ-on-ATZ and ZTA-on-ZTA bearing combinations were tested and compared with alumina-on-alumina (Al2O3-on-Al2O3) bearings under adverse microseparation and edge loading conditions using the Leeds II physiological anatomical hip joint simulator. The wear rate (±95% confidence limit) of ZTA-on-ZTA was 0.14 ± 0.10 mm(3)/million cycles and that of ATZ-on-ATZ was 0.06 ± 0.004 mm(3)/million cycles compared with a wear rate of 0.74 ± 1.73 mm(3)/million cycles for Al2O3-on-Al2O3 bearings. Stripe wear was evident on all bearing combinations; however, the stripe formed on the ATZ and ZTA femoral heads was thinner and shallower that that formed on the Al2O3 heads. Posttest phase composition measurements for both ATZ and ZTA materials showed no significant change in the monoclinic zirconia content. ATZ-on-ATZ and ZTA-on-ZTA showed superior wear resistance properties when compared with Al2O3-on-Al2O3 under adverse edge loading conditions.


Assuntos
Artroplastia de Quadril/instrumentação , Materiais Biocompatíveis/química , Cerâmica/química , Prótese de Quadril , Óxido de Alumínio/química , Animais , Bovinos , Análise de Falha de Equipamento/métodos , Articulação do Quadril/patologia , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Desenho de Prótese , Falha de Prótese , Propriedades de Superfície , Zircônio/química
10.
Acta Biomater ; 9(7): 7545-55, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23541600

RESUMO

The degradation of zirconia-based ceramic components for total hip arthroplasty (head and cup) has been the topic of many works. However, the correlation between what is measured in vivo and what is expected from in vitro simulations on hip simulators may be sometimes feeble, especially where zirconia component are concerned, mainly due to a lack of representativeness of in vitro experiments. The present study seeks to explore the combined effects of hydrothermal ageing and wear on zirconia components. It shows that hydrothermal ageing increases the roughness of zirconia components, which in turn might increase the wear rate of the polyethylene counterparts. Moreover, the friction during hip simulation increases the ageing rate of the zirconia components. This auto-accelerating degradation may explain some of the poor long-term in vivo results of zirconia hip prostheses reported in the literature. Finally, it is shown that zirconia-toughened alumina components may be free from this combined degradation.


Assuntos
Óxido de Alumínio/química , Artroplastia de Quadril/instrumentação , Biomimética/métodos , Cerâmica/química , Análise de Falha de Equipamento/métodos , Zircônio/química , Óxido de Alumínio/análise , Artroplastia de Quadril/métodos , Cerâmica/análise , Fricção , Dureza , Prótese de Quadril , Temperatura Alta , Teste de Materiais , Pressão , Zircônio/análise
12.
Europace ; 15(1): 55-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23089188

RESUMO

AIM: To find out whether it is possible to anaesthetize patients safely without analgesia and sedation, using burst pacing prolonged until the patient becomes unconscious. METHODS: One hundred and four patients undergoing implantation or reimplantation of a cardioverter-defibrillator were included. Patients randomized into Group B underwent prolonged burst pacing without analgesia and sedation. Patients in Group T underwent a T-wave shock under analgesia and sedation. Blood samples for measurement of serum neuron-specific enolase were taken before surgery and 6, 24, and 48 h after the procedure. RESULTS: From the 104 patients, 51 were randomly assigned to Group B and 53 to Group T. Four patients from Group B were switched to Group T (ventricular fibrillation not induced by burst pacing). The clinical characteristics of both groups were similar. The mean total time of cardiac arrest was significantly longer in Group B (23.0 ± 4.4 s, median 22.7) vs. Group T (10.3 ± 3.0 s, median 10.0), P < 0.0001 (Mann-Whitney U-test). The effectiveness of both induction methods was similar (92.1% in Group B and 100% in Group T). The mean neuron-specific enolase levels after 6, 24, and 48 h were similar in Groups B and T (13.1 ± 6.3 and 11.6 ± 5.8 mg/L, 14.5 ± 7.5 and 13.4 ± 6.0 mg/L, and 14.9 ± 5.9 and 12.2 ± 6.0 mg/L, respectively) as were these levels compared with baseline neuron-specificenolase levels (14.0 ± 5.9 and 13.4 ± 4.0 mg/L, respectively), P = NS for all. CONCLUSION: Despite a longer time of total cardiac arrest, prolonged burst pacing appears to be a safe and effective method for induction of ventricular fibrillation during cardioverter-defibrillator testing, which enables omission of analgesia and sedation or general anaesthesia.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/métodos , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle , Idoso , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
J R Soc Interface ; 10(79): 20120849, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23221990

RESUMO

High-performance biological materials such as nacre, spider silk or bone have evolved a staggered microstructure consisting of stiff and strong elongated inclusions aligned with the direction of loading. This structure leads to useful combinations of stiffness, strength and toughness, and it is therefore increasingly mimicked in bio-inspired composites. The performance of staggered composites can be tuned; for example, their mechanical properties increase when the overlap between the inclusions is increased. However, larger overlaps may lead to excessive tensile stress and fracture of the inclusions themselves, a highly detrimental failure mode. Fracture of the inclusions has so far only been predicted using highly simplified models, which hinder our ability to properly design and optimize engineered staggered composites. In this work, we develop a new failure criterion that takes into account the complex stress field within the inclusions as well as initial defects. The model leads to an 'optimum criterion' for cases where the shear tractions on the inclusions is uniform, and a 'conservative' criterion for which the tractions are modelled as point forces at the ends of the overlap regions. The criterion can therefore be applied for a wide array of material behaviour at the interface, even if the details of the shear load transfer is not known. The new criterion is validated with experiments on staggered structures made of millimetre-thick alumina tablets, and by comparison with data on nacre. Formulated in a non-dimensional form, our new criterion can be applied on a wide variety of engineered staggered composites at any length scale. It also reveals new design guidelines, for example high aspect ratio inclusions with weak interfaces are preferable over inclusions with low aspect ratio and stronger interfaces. Together with existing models, this new criterion will lead to optimal designs that harness the full potential of bio-inspired staggered composites.


Assuntos
Materiais Biomiméticos/química , Análise de Falha de Equipamento/métodos , Substâncias Macromoleculares/química , Modelos Teóricos , Estresse Mecânico , Óxido de Alumínio/química , Elasticidade , Nácar/química , Resistência ao Cisalhamento , Resistência à Tração
14.
J Bone Joint Surg Br ; 94(7): 901-7, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22733943

RESUMO

We analysed 54 alumina ceramic-on-ceramic bearings from total hip replacements retrieved at one centre after a mean duration of 3.5 years (0.2 to 10.6) in situ. These implants were obtained from 54 patients (16 men and 38 women) with a mean age of 67 years (33 to 88) who underwent revision for a variety of reasons. Posterior edge loading was found in the majority of these retrievals (32 out of 54). Anterosuperior edge loading occurred less often but produced a higher rate of wear. Stripe wear on the femoral heads had a median volumetric wear rate of 0.2 mm(3)/year (0 to 7.2). The wear volume on the femoral heads corresponded to the width of edge wear on the matching liner. Anteversion of the acetabular component was found to be a more important determinant than inclination for wear in ceramic bearings. Posterior edge loading may be considered to be a normal occurrence in ceramic-on-ceramic bearings, with minimal clinical consequences. Edge loading should be defined as either anterosuperior or posterior, as each edge loading mechanism may result in different clinical implications.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Óxido de Alumínio , Artroplastia de Quadril/métodos , Cerâmica , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Suporte de Carga
15.
J Mater Sci Mater Med ; 23(6): 1533-42, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22454139

RESUMO

A novel material combination of a large diameter Biolox(®) Delta zirconia-toughened-alumina (ZTA) head and a pitch-based carbon fibre reinforced poly ether-ether-ketone (CFR-PEEK) MOTIS(®) cup has been studied. The acetabular cups were inclined at three angles and tested using Durham Hip Simulators. The different inclination angles used did not have a significant effect on the wear rates (ANOVA, p = 0.646). Averaged over all cups, the wear rates were calculated to be 0.551 ± 0.115 mm(3)/10(6) cycles and 0.493 ± 0.107 mm(3)/10(6) cycles taking into account two types of soak controls; loaded at room temperature and unloaded at 37 °C respectively. Averaged across all femoral heads, the wear rate was 0.243 ± 0.031 mm(3)/10(6) cycles. The temperature change of the lubricant caused by the frictional heat was measured in situ. Friction factors measured using the Durham Friction Simulator were lower for the worn CFR-PEEK cups compared with unworn. This correlated with the decreased surface roughness. Even though relatively high friction was observed in these hemispherical hard-on-soft bearings, the wear rate is encouragingly low.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/química , Prótese de Quadril , Falha de Prótese , Absorção , Óxido de Alumínio , Benzofenonas , Fenômenos Biomecânicos , Líquidos Corporais/fisiologia , Carbono , Fibra de Carbono , Cerâmica , Análise de Falha de Equipamento/métodos , Fricção , Temperatura Alta/efeitos adversos , Humanos , Técnicas In Vitro , Cetonas , Microscopia de Força Atômica , Polietilenoglicóis , Polímeros , Propriedades de Superfície , Zircônio
16.
Opt Express ; 20(2): 854-63, 2012 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-22274431

RESUMO

Damage tests are carried out at 1064nm to measure the laser resistance of TiO(2)/Al(2)O(3) and HfO(2)/Al(2)O(3) antireflection coatings grown by atomic layer deposition (ALD). The damage results are determined by S-on-1 and R-on-1 tests. Interestingly, the damage performance of ALD coatings is similar to those grown by conventional e-beam evaporation process. A decline law of damage resistance under multiple irradiations is revealed. The influence of growth temperature on damage performance has been investigated. Result shows that the crystallization of TiO(2) layer at higher temperature could lead to numerous absorption defects that reduce the laser-induced damage threshold (LIDT). In addition, it has been found that using inorganic compound instead of organic compound as precursors for ALD process maybe effectively prevent carbon impurities in films and will increase the LIDT obviously.


Assuntos
Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Lasers , Óptica e Fotônica/instrumentação , Óptica e Fotônica/métodos , Óxido de Alumínio/química , Háfnio/química , Modelos Teóricos , Óxidos/química , Propriedades de Superfície , Titânio/química
17.
J Bone Joint Surg Br ; 94(1): 37-42, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22219245

RESUMO

Alumina-alumina bearings are among the most resistant to wear in total hip replacement. Examination of their surfaces is one way of comparing damage caused by wear of hip joints simulated in vitro to that seen in explanted bearings. The aim of this study was to determine whether second-generation ceramic bearings exhibited a better pattern of wear than those reported in the literature for first-generation bearings. We considered both macro- and microscopic findings. We found that long-term alumina wear in association with a loose acetabular component could be categorised into three groups. Of 20 specimens, four had 'low wear', eight 'crescent wear' and eight 'severe wear', which was characterised by a change in the physical shape of the bearing and a loss of volume. This suggests that the wear in alumina-alumina bearings in association with a loose acetabular component may be variable in pattern, and may explain, in part, why the wear of a ceramic head in vivo may be greater than that seen after in vitro testing.


Assuntos
Óxido de Alumínio , Análise de Falha de Equipamento/métodos , Prótese de Quadril , Falha de Prótese/etiologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril , Feminino , Cabeça do Fêmur , Humanos , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Propriedades de Superfície
20.
AJR Am J Roentgenol ; 196(2): 437-45, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21257898

RESUMO

OBJECTIVE: Implantation of a spinal cord stimulator (SCS) is one option for pain control in individuals with chronic lumbosacral radicular or axial lumbar pain. The expected positioning of SCSs based on the location of pain, the types of electrodes (percutaneous vs surgical paddle), and the types of electrode arrays and the potential complications have not been described to date in the radiology literature. MATERIALS AND METHODS: A 5-year retrospective review of the radiology information system at our institution revealed 24 patients with images of 36 SCSs. Those images were reviewed to identify the location and type of electrodes as well as the location of the lead within the spinal canal. Not all implantable pulse generators were within the radiologic field of view. Complications identified by reviewing medical records were correlated with imaging findings. RESULTS: Fourteen different types of electrodes were identified. Most were placed in the thoracic spine only, but six thoracolumbar and two cervical spine electrodes were also present. We measured the position of the electrodes within the spinal canal on 26 CT studies of the 24 patients. On 22 of 26 CT studies, the electrodes were placed in the epidural space in the posterior one third of the spinal canal. Complications included misplaced, retained, and broken leads; puncture of the thecal sac; infection; and hematoma. CONCLUSION: Radiologists should be familiar with the different types of electrodes and typical spinal locations of electrodes, leads, and implantable pulse generators. Improper placement of electrodes may lead to ineffective pain relief or to other complications.


Assuntos
Dor nas Costas/etiologia , Dor nas Costas/terapia , Terapia por Estimulação Elétrica/efeitos adversos , Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados/efeitos adversos , Análise de Falha de Equipamento/métodos , Próteses e Implantes/efeitos adversos , Medula Espinal/diagnóstico por imagem , Idoso , Dor nas Costas/diagnóstico por imagem , Doença Crônica , Terapia por Estimulação Elétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mielografia , Postura , Estudos Retrospectivos , Traumatismos da Coluna Vertebral/complicações , Tomografia Computadorizada por Raios X , Resultado do Tratamento