Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Anesth Analg ; 128(6): e88-e92, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31094779

RESUMO

Automated titration of intravenous anesthesia and analgesia using processed electroencephalography monitoring is no longer a novel concept. Closed-loop control of fluid administration to provide goal-directed fluid therapy has also been increasingly described. However, simultaneously combining 2 independent closed-loop systems together in patients undergoing major vascular surgery has not been previously detailed. The aim of this pilot study was to evaluate the clinical performance of fully automated hypnosis, analgesia, and fluid management using 2 independent closed-loop controllers in patients undergoing major vascular surgery before implementation within a larger study evaluating true patient outcomes.


Assuntos
Analgesia/métodos , Anestesia com Circuito Fechado/métodos , Hidratação/métodos , Hipnóticos e Sedativos/uso terapêutico , Monitorização Intraoperatória/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Idoso , Anestesia Intravenosa/métodos , Automação , Estudos de Viabilidade , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Manejo da Dor/métodos , Projetos Piloto , Resultado do Tratamento
2.
J Anesth ; 31(6): 911-914, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28831619

RESUMO

We investigated whether calcium chloride (CaCl2), a supplementary additive in carbon dioxide (CO2) absorbents, could affect carbon monoxide (CO) production caused by desflurane degradation, using a Japanese alkali-free CO2 absorbent Yabashi Lime®-f (YL-f), its CaCl2-free and 1% CaCl2-added derivatives, and other commercially available alkali-free absorbents with or without CaCl2. The reaction between 1 L of desflurane gas (3-10%) and 20 g of desiccated specimen was performed in an artificial closed-circuit anesthesia system for 3 min at 20 or 40 °C. The CO concentration was measured using a gas chromatograph equipped with a semiconductor sensor detector. The systems were validated by detecting dose-dependent CO production with an alkali hydroxide-containing CO2 absorbent, Sodasorb®. Compared with YL-f, the CaCl2-free derivative caused the production of significantly more CO, while the 1% CaCl2-added derivative caused the production of a comparable amount of CO. These phenomena were confirmed using commercially available absorbents AMSORB® PLUS, an alkali-free absorbent with CaCl2, and LoFloSorb™, an alkali-free absorbent without CaCl2. These results suggest that CaCl2 plays an important role in preventing CO generation caused by desflurane degradation with alkali hydroxide-free CO2 absorbents like YL-f.


Assuntos
Cloreto de Cálcio/química , Dióxido de Carbono/química , Monóxido de Carbono/química , Isoflurano/análogos & derivados , Álcalis/química , Anestesia com Circuito Fechado , Anestésicos Inalatórios/química , Anestésicos Inalatórios/metabolismo , Hidróxido de Cálcio/química , Desflurano , Hidróxidos/química , Isoflurano/química
3.
J Vet Med Sci ; 77(8): 961-5, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25843038

RESUMO

In the present study, we compare a new carbon dioxide (CO2) absorbent, Yabashi lime(®) with a conventional CO2 absorbent, Sodasorb(®) as a control CO2 absorbent for Compound A (CA) and Carbon monoxide (CO) productions. Four dogs were anesthetized with sevoflurane. Each dog was anesthetized with four preparations, Yabashi lime(®) with high or low-flow rate of oxygen and control CO2 absorbent with high or low-flow rate. CA and CO concentrations in the anesthetic circuit, canister temperature and carbooxyhemoglobin (COHb) concentration in the blood were measured. Yabashi lime(®) did not produce CA. Control CO2 absorbent generated CA, and its concentration was significantly higher in low-flow rate than a high-flow rate. CO was generated only in low-flow rate groups, but there was no significance between Yabashi lime(®) groups and control CO2 absorbent groups. However, the CO concentration in the circuit could not be detected (≤5ppm), and no change was found in COHb level. Canister temperature was significantly higher in low-flow rate groups than high-flow rate groups. Furthermore, in low-flow rate groups, the lower layer of canister temperature in control CO2 absorbent group was significantly higher than Yabashi lime(®) group. CA and CO productions are thought to be related to the composition of CO2 absorbent, flow rate and canister temperature. Though CO concentration is equal, it might be safer to use Yabashi lime(®) with sevoflurane anesthesia in dogs than conventional CO2 absorbent at the point of CA production.


Assuntos
Anestesia por Inalação/veterinária , Anestésicos Inalatórios , Hidróxido de Cálcio/uso terapêutico , Dióxido de Carbono , Cães , Éteres Metílicos , Adsorção , Anestesia com Circuito Fechado/instrumentação , Anestesia com Circuito Fechado/métodos , Anestesia com Circuito Fechado/veterinária , Anestesia por Inalação/métodos , Animais , Dióxido de Carbono/sangue , Carboxihemoglobina/análise , Cães/cirurgia , Feminino , Masculino , Oxigênio/sangue , Sevoflurano
4.
J Clin Monit Comput ; 28(1): 27-34, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23771652

RESUMO

To control the three components of general anesthesia (hypnosis, analgesia, and neuromuscular blockade), an automated closed-loop, anesthesia-drug delivery system (McSleepy) was developed. Bispectral index was used as the control variable for hypnosis, the analgoscore for analgesia, and phonomyography for neuromuscular blockade. McSleepy can be used to control the induction, maintenance and emergence from general anesthesia. To do so, a large touch screen is used to provide a user friendly interface, permitting bidirectional communication: the user giving information about the different stages of anesthesia, and the system prompting the anesthesiologist to perform certain actions such as mask ventilation, intubation or waking-up the patient using audio clips with voice commands. Several safety features were implemented to provide a secure and reliable anesthesia. Preliminary results of 15 patients are presented in this paper. Evaluation of McSleepy was done through an assessment of its clinical performance and using Varvel's performance indices. The system was found to be clinically useful by providing good precision in drug administration and reliable results for the duration of a general anesthesia.


Assuntos
Analgesia/métodos , Anestesia com Circuito Fechado/métodos , Hipnose/métodos , Intubação/métodos , Bloqueio Neuromuscular/métodos , Robótica , Telemedicina/métodos , Adulto , Idoso , Analgesia/instrumentação , Androstanóis/administração & dosagem , Anestesia com Circuito Fechado/instrumentação , Automação , Gráficos por Computador , Feminino , Humanos , Hipnose/instrumentação , Masculino , Pessoa de Meia-Idade , Bloqueio Neuromuscular/instrumentação , Piperidinas/administração & dosagem , Propofol/administração & dosagem , Remifentanil , Reprodutibilidade dos Testes , Rocurônio , Software , Interface Usuário-Computador
5.
Anesth Analg ; 112(2): 350-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21156973

RESUMO

BACKGROUND: Research has demonstrated the efficacy of closed-loop control of anesthesia using bispectral index (BIS) as the controlled variable. Model-based and proportional-integral-derivative (PID) controllers outperform manual control. We investigated the application of reinforcement learning (RL), an intelligent systems control method, to closed-loop BIS-guided, propofol-induced hypnosis in simulated intraoperative patients. We also compared the performance of the RL agent against that of a conventional PID controller. METHODS: The RL and PID controllers were evaluated during propofol induction and maintenance of hypnosis. The patient-hypnotic episodes were designed to challenge both controllers with varying degrees of interindividual variation and noxious surgical stimulation. Each controller was tested in 1000 simulated patients, and control performance was assessed by calculating the median performance error (MDPE), median absolute performance error (MDAPE), Wobble, and Divergence for each controller group. A separate analysis was performed for the induction and maintenance phases of hypnosis. RESULTS: During maintenance, RL control demonstrated an MDPE of -1% and an MDAPE of 3.75%, with 80% of the time at BIS(target) ± 5. The PID controller yielded a MDPE of -8.5% and an MDAPE of 8.6%, with 57% of the time at BIS(target) ± 5. In comparison, the MDAPE in the worst-controlled patient of the RL group was observed to be almost half that of the worst-controlled patient in the PID group. CONCLUSIONS: When compared with the PID controller, RL control resulted in slower induction but less overshoot and faster attainment of steady state. No difference in interindividual patient variation and noxious destabilizing challenge on control performance was observed between the 2 patient groups.


Assuntos
Anestesia com Circuito Fechado , Anestésicos Intravenosos/administração & dosagem , Inteligência Artificial , Simulação por Computador , Monitores de Consciência , Hipnose Anestésica , Modelos Teóricos , Monitorização Intraoperatória , Simulação de Paciente , Propofol/administração & dosagem , Anestésicos Intravenosos/farmacocinética , Relação Dose-Resposta a Droga , Humanos , Período Intraoperatório , Masculino , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Reconhecimento Automatizado de Padrão , Propofol/farmacocinética , Processamento de Sinais Assistido por Computador , Adulto Jovem
6.
Anesth Analg ; 112(2): 360-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21156984

RESUMO

Reinforcement learning (RL) is an intelligent systems technique with a history of success in difficult robotic control problems. Similar machine learning techniques, such as artificial neural networks and fuzzy logic, have been successfully applied to clinical control problems. Although RL presents a mathematically robust method of achieving optimal control in systems challenged with noise, nonlinearity, time delay, and uncertainty, no application of RL in clinical anesthesia has been reported.


Assuntos
Anestesia com Circuito Fechado , Anestésicos Intravenosos/administração & dosagem , Inteligência Artificial , Monitores de Consciência , Hipnose Anestésica , Modelos Teóricos , Monitorização Intraoperatória , Propofol/administração & dosagem , Anestésicos Intravenosos/farmacocinética , Relação Dose-Resposta a Droga , Humanos , Período Intraoperatório , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Reconhecimento Automatizado de Padrão , Propofol/farmacocinética , Processamento de Sinais Assistido por Computador
7.
Artigo em Inglês | MEDLINE | ID: mdl-19963562

RESUMO

Research has demonstrated the efficacy of closed-loop control of anesthesia using bispectral index (BIS) as the controlled variable, and the recent development of model-based, patient-adaptive systems has considerably improved anesthetic control. To further explore the use of model-based control in anesthesia, we investigated the application of fuzzy control in the delivery of patient-specific propofol-induced hypnosis. In simulated intraoperative patients, the fuzzy controller demonstrated clinically acceptable performance, suggesting that further study is warranted.


Assuntos
Hipnose , Propofol/farmacologia , Algoritmos , Anestesia com Circuito Fechado/métodos , Anestésicos Intravenosos/farmacologia , Simulação por Computador , Desenho de Equipamento , Lógica Fuzzy , Humanos , Período Intraoperatório , Modelos Estatísticos , Monitorização Intraoperatória , Reconhecimento Automatizado de Padrão , Propofol/farmacocinética , Software
8.
Anesth Analg ; 107(5): 1707-13, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18931236

RESUMO

BACKGROUND: Noninvasive positive-pressure ventilation (NPPV) with pressure support-ventilation and positive end-expiratory pressure are effective in providing oxygenation during intubation in hypoxemic patients. We hypothesized administration of oxygen (O2) using NPPV would more rapidly increase the end-tidal O2 concentration (ETO2) than preoxygenation using spontaneous ventilation (SV) in morbidly obese patients. METHODS: Twenty-eight morbidly obese patients were enrolled in this prospective randomized study. Administration of O2 for 5 min was performed either with SV group or with NPPV (pressure support = 8 cm H2O, positive end-expiratory pressure = 6 cm H2O) (NPPV group). ETO2 was measured using the anesthesia breathing circuit, and is expressed as a fraction of atmospheric concentration. The primary end-point was the number of patients with an ETo(2) >95% at the end of O2 administration. Secondary end-points included the time to reach the maximal ETO2 and the ETO2 at the conclusion of O2 administration. RESULTS: A larger proportion of patients achieved a 95% ETO2 at 5 min with NPPV than SV (13/14 vs 7/14, P = 0.01). The time to reach the maximal ETO2 was significantly less in the NPPV than in the SV group (185 +/- 46 vs 222 +/- 42 s, P = 0.02). The mean ETO2 at the conclusion of O2 administration was larger in the NPPV group than the SV group (96.9 +/- 1.3 vs 94.1 +/- 2.0%, P < 0.001). A modest, although significant, increase in gastric distension was observed in the NPPV group. No adverse effects were observed in either group. CONCLUSION: Administration of O2 via a facemask with NPPV in the operating room is safe, feasible, and efficient in morbidly obese patients. In this population NPPV provides a more rapid O2 administration, achieving a higher ETO2.


Assuntos
Oxigenoterapia Hiperbárica/métodos , Ventilação com Pressão Positiva Intermitente/métodos , Obesidade Mórbida/fisiopatologia , Oxigenoterapia/métodos , Respiração com Pressão Positiva/métodos , Adulto , Anestesia com Circuito Fechado , Humanos , Obesidade Mórbida/complicações , Oxigênio/sangue , Seleção de Pacientes , Respiração Artificial , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Volume de Ventilação Pulmonar
9.
IEEE Trans Biomed Eng ; 48(8): 874-89, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11499525

RESUMO

A model-based closed-loop control system is presented to regulate hypnosis with the volatile anesthetic isoflurane. Hypnosis is assessed by means of the bispectral index (BIS), a processed parameter derived from the electroencephalogram. Isoflurane is administered through a closed-circuit respiratory system. The model for control was identified on a population of 20 healthy volunteers. It consists of three parts: a model for the respiratory system, a pharmacokinetic model and a pharmacodynamic model to predict BIS at the effect compartment. A cascaded internal model controller is employed. The master controller compares the actual BIS and the reference value set by the anesthesiologist and provides expired isoflurane concentration references to the slave controller. The slave controller maneuvers the fresh gas anesthetic concentration entering the respiratory system. The controller is designed to adapt to different respiratory conditions. Anti-windup measures protect against performance degradation in the event of saturation of the input signal. Fault detection schemes in the controller cope with BIS and expired concentration measurement artifacts. The results of clinical studies on humans are presented.


Assuntos
Anestesia com Circuito Fechado/métodos , Anestésicos Inalatórios/farmacologia , Eletroencefalografia , Isoflurano/farmacologia , Monitorização Fisiológica/métodos , Adulto , Anestésicos Inalatórios/administração & dosagem , Anestésicos Inalatórios/farmacocinética , Eletrodos , Desenho de Equipamento , Feminino , Hemodinâmica , Humanos , Isoflurano/administração & dosagem , Isoflurano/farmacocinética , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Análise de Regressão , Processamento de Sinais Assistido por Computador
11.
Eur J Anaesthesiol ; 12(4): 357-61, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7588664

RESUMO

The laryngeal mask airway (LMA) provides a view of the larynx and moving vocal cords without loss of airway control and can be used in flexible fibreoptic bronchoscopy for both anaesthetized and awake patients. In this retrospective review of 200 consecutive patients over a 30 month period, bronchoscopy was successful via the LMA in all but one patient using a technique of topical anaesthesia and sedation. The LMA directs the fibrescope to the glottis, allows respiratory function to be monitored and oxygen to be given. Complication rates were similar to those reported for transnasal awake bronchoscopy. Insertion of the LMA in the awake fasted patient is safe and easily achieved.


Assuntos
Broncoscopia , Máscaras Laríngeas , Vigília , Adjuvantes Anestésicos/administração & dosagem , Anestesia com Circuito Fechado , Anestesia Local , Anestésicos Locais/administração & dosagem , Broncoscópios , Broncoscopia/efeitos adversos , Broncoscopia/métodos , Sedação Consciente , Jejum , Feminino , Tecnologia de Fibra Óptica , Humanos , Hipnóticos e Sedativos/administração & dosagem , Máscaras Laríngeas/efeitos adversos , Laringe/anatomia & histologia , Lidocaína/administração & dosagem , Masculino , Meperidina/administração & dosagem , Pessoa de Meia-Idade , Oxigênio/administração & dosagem , Medicação Pré-Anestésica , Propofol/administração & dosagem , Respiração , Estudos Retrospectivos , Prega Vocal/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA