Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.760
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 281(8): 4161-4173, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38573516

RESUMO

PURPOSE: To study outcome after cochlear implantation using the Cochlear Implant (CI) outcome assessment protocol based on the International Classification of Functioning, Disability and Health (ICF) model (CI-ICF). METHODS: Raw data of a prospective, longitudinal, multicenter study was analyzed. Seventy-two CI candidates were assessed preoperatively and six months postoperatively using the CI-ICF protocol. Following tools were used: (1) Work Rehabilitation Questionnaire (WORQ), (2) Abbreviated Profile of Hearing Aid Benefit (APHAB), (3) Audio Processor Satisfaction Questionnaire (APSQ), (4) Speech, Spatial, and Qualities of Hearing Scale (SSQ12), (5) Hearing Implant Sound Quality Index (HISQUI19), (6) Nijmegen CI Questionnaire (NCIQ) (7) pure tone audiometry, (8) speech audiometry, (9) sound localization. RESULTS: There was a significant improvement of speech discrimination in quiet (p = 0.015; p < 0.001) and in noise (p = 0.041; p < 0.001), sound detection (p < 0.001), tinnitus (p = 0.026), listening (p < 0.001), communicating with-receiving-spoken messages (p < 0.001), conversation (p < 0.001), family relationships (p < 0.001), community life (p = 0.019), NCIQ total score and all subdomain scores (p < 0.001). Subjective sound localization significantly improved (p < 0.001), while psychometric sound localization did not. There was no significant subjective deterioration of vestibular functioning and no substantial change in sound aversiveness. CI users reported a high level of implant satisfaction postoperatively. CONCLUSION: This study highlights the positive impact of cochlear implantation on auditory performance, communication, and subjective well-being. The CI-ICF protocol provides a holistic and comprehensive view of the evolution of CI outcomes.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Adulto , Estudos Longitudinais , Percepção da Fala , Inquéritos e Questionários , Classificação Internacional de Funcionalidade, Incapacidade e Saúde , Resultado do Tratamento , Satisfação do Paciente , Avaliação da Deficiência , Adulto Jovem , Avaliação de Resultados em Cuidados de Saúde , Audiometria de Tons Puros , Adolescente
2.
Fa Yi Xue Za Zhi ; 40(1): 15-19, 2024 Feb 25.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38500456

RESUMO

OBJECTIVES: To study the application of CE-Chirp in the evaluation of hearing impairment in forensic medicine by testing the auditory brainstem response (ABR) in adults using CE-Chirp to analyze the relationship between the V-wave response threshold of CE-Chirp ABR test and the pure tone hearing threshold. METHODS: Subjects (aged 20-77 with a total of 100 ears) who underwent CE-Chirp ABR test in Changzhou De'an Hospital from January 2018 to June 2019 were selected to obtain the V-wave response threshold, and pure tone air conduction hearing threshold tests were conducted at 0.5, 1.0, 2.0 and 4.0 kHz, respectively, to obtain pure tone listening threshold. The differences and statistical differences between the average pure tone hearing threshold and V-wave response threshold were compared in different hearing levels and different age groups. The correlation, differences and statistical differences between the two tests at each frequency were analyzed for all subjects. The linear regression equation for estimating pure tone hearing threshold for all subjects CE-Chirp ABR V-wave response threshold was established, and the feasibility of the equation was tested. RESULTS: There was no statistical significance in the CE-Chirp ABR response threshold and pure tone hearing threshold difference between different hearing level groups and different age groups (P>0.05). There was a good correlation between adult CE-Chirp ABR V-wave response threshold and pure tone hearing threshold with statistical significance (P<0.05), and linear regression analysis showed a significant linear correlation between the two (P<0.05). CONCLUSIONS: The use of CE-Chirp ABR V-wave response threshold can be used to evaluate subjects' pure tone hearing threshold under certain conditions, and can be used as an audiological test method for forensic hearing impairment assessment.


Assuntos
Perda Auditiva , Audição , Adulto , Humanos , Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Audição/fisiologia , Perda Auditiva/diagnóstico , Audiometria de Tons Puros/métodos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia
3.
Br J Haematol ; 204(5): 2016-2024, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38500389

RESUMO

BACKGROUND: Despite numerous studies, the true scenario of hearing loss in beta-thalassaemia remains rather nebulous. MATERIALS AND METHODS: Pure tone audiometry, chelation therapy, demographics and laboratory data of 376 patients (mean age 38.5 ± 16.6 years, 204 females, 66 non-transfusion-dependent) and 139 healthy controls (mean age 37.6 ± 17.7 years, 81 females) were collected. RESULTS: Patient and control groups did not differ for age (p = 0.59) or sex (p = 0.44). Hypoacusis rate was higher in patients (26.6% vs. 7.2%; p < 0.00001), correlated with male sex (32.6% in males vs. 21.8% in females; p = 0.01) and it was sensorineural in 79/100. Hypoacusis rate correlated with increasing age (p = 0.0006) but not with phenotype (13/66 non-transfusion-dependent vs. 87/310 transfusion-dependent patients; p = 0.16). Sensorineural-notch prevalence rate did not differ between patients (11.4%) and controls (12.2%); it correlated with age (p = 0.01) but not with patients' sex or phenotype. Among adult patients without chelation therapy, the sensorineural hypoacusis rate was non-significantly lower compared to chelation-treated patients while it was significantly higher compared to controls (p = 0.003). CONCLUSIONS: Sensorineural hypoacusis rate is high in beta-thalassaemia (about 21%) and it increases with age and in males while disease severity or chelation treatment seems to be less relevant. The meaning of sensorineural-notch in beta-thalassaemia appears questionable.


Assuntos
Talassemia beta , Humanos , Talassemia beta/complicações , Talassemia beta/terapia , Masculino , Feminino , Adulto , Estudos de Casos e Controles , Pessoa de Meia-Idade , Itália/epidemiologia , Adulto Jovem , Terapia por Quelação , Perda Auditiva/epidemiologia , Perda Auditiva/etiologia , Adolescente , Audiometria de Tons Puros , Perda Auditiva Neurossensorial/epidemiologia , Perda Auditiva Neurossensorial/etiologia , Prevalência
4.
Ann Otol Rhinol Laryngol ; 133(4): 400-405, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38197374

RESUMO

OBJECTIVE: Hyperbaric oxygen therapy (HBOT) is an accepted treatment option for sudden sensorineural hearing loss (SSNHL), but it is still recommended in combination with corticosteroids. We investigated the efficacy of salvage HBOT in refractory SSNHL that does not respond to corticosteroid combination therapy. METHODS: Eighty-four patients were included, who had unilateral SSNHL with an improvement of pure-tone average (PTA) less than 10 dB after using intratympanic plus systemic corticosteroids (combined therapy) as the initial therapy. The control group (n = 66) received no further treatment, and the HBOT group (n = 18) received additional treatment with HBOT (10 sessions in total with 2.5 atmospheres absolute for 1 hour). RESULTS: No differences in PTA or WDS were found between the 2 groups. However, the mean hearing gain in the HBOT group (16.8 ± 4.49 dB) was significantly higher than that in the control group (4.45 ± 1.03 dB) (P = .015). The proportion of patients with hearing recovery (hearing gain of 10 dB or more) after treatment was significantly higher in HBOT group (38.9%) than in the control group (10.6%). CONCLUSIONS: In patients with refractory SSNHL after steroid combined therapy, salvage HBOT showed a significant effect on hearing gain and recovery rate.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Oxigenoterapia Hiperbárica , Humanos , Perda Auditiva Súbita/terapia , Perda Auditiva Neurossensorial/terapia , Glucocorticoides/uso terapêutico , Dexametasona/uso terapêutico , Esteroides , Terapia de Salvação , Resultado do Tratamento , Audiometria de Tons Puros
5.
J Acoust Soc Am ; 154(6): 3821-3832, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109406

RESUMO

Auditory enhancement is a spectral contrast aftereffect that can facilitate the detection of novel events in an ongoing background. A single-interval paradigm combined with roved frequency content between trials can yield as much as 20 dB enhancement in young normal-hearing listeners. This study compared such enhancement in 15 listeners with sensorineural hearing loss with that in 15 age-matched adults and 15 young adults with normal audiograms. All groups were presented with stimulus levels of 70 dB sound pressure level (SPL) per component. The two groups with normal hearing were also tested at 45 dB SPL per component. The hearing-impaired listeners showed very little enhancement overall. However, when tested at the same high (70-dB) level, both young and age-matched normal-hearing listeners also showed substantially reduced enhancement, relative to that found at 45 dB SPL. Some differences in enhancement emerged between young and older normal-hearing listeners at the lower sound level. The results suggest that enhancement is highly level-dependent and may also decrease somewhat with age or slight hearing loss. Implications for hearing-impaired listeners may include a poorer ability to adapt to real-world acoustic variability, due in part to the higher levels at which sound must be presented to be audible.


Assuntos
Surdez , Perda Auditiva Neurossensorial , Percepção da Fala , Adulto Jovem , Humanos , Estimulação Acústica , Perda Auditiva Neurossensorial/diagnóstico , Som , Audiometria de Tons Puros , Limiar Auditivo
6.
Otol Neurotol ; 44(8): 780-785, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37464465

RESUMO

OBJECTIVES: The objectives of this study are to (i) estimate the incidence of vestibular schwannoma (VS) among patients in an integrated healthcare system who present for evaluation of sudden sensorineural hearing loss (SSNHL) and (ii) evaluate the efficacy of empiric steroid therapy on audiologic recovery among SSNHL patients ultimately diagnosed with VS. METHODS: A retrospective chart review was performed on patients presenting with SSNHL in 2021 at a multicenter integrated healthcare system serving over 4 million members. Patient demographics, audiometric data, VS diagnosis, therapeutic steroid intervention, and data regarding treatment response were recorded. A clinically significant audiometric improvement was defined as (i) an increase of 15% in word recognition score, (ii) a decrease of 15 dB in four-frequency pure-tone average (PTA) using frequencies of 500, 1000, 2000, and 4000 Hz, or (iii) a PTA of <20 dB on follow-up audiogram. RESULTS: Six hundred fifty-eight patients were reviewed, of which 309 (56.0% male; mean, 57.5 years) met the inclusion criteria with audiometric data and magnetic resonance imaging data. Ten patients (70.0% male; mean, 51.3 years) were found to have VS. Of these, five patients received oral steroid therapy alone, and five had combination therapy (oral + intratympanic steroid injections). No patients received intratympanic steroid therapy alone. Median PTA improvement with steroid therapy was 3.1-dB hearing loss, and median word recognition score improvement was 16.5%. Six of 10 patients demonstrated clinically significant audiometric improvement with steroid therapy. CONCLUSION: This study represents the largest US-based study showcasing the prevalence of VS in patients originally presenting with SSNHL. It also reinforces previous findings that VS does not preclude trials of steroid therapy.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Neuroma Acústico , Humanos , Masculino , Feminino , Estudos Retrospectivos , Neuroma Acústico/complicações , Neuroma Acústico/tratamento farmacológico , Dexametasona , Perda Auditiva Súbita/tratamento farmacológico , Perda Auditiva Súbita/diagnóstico , Perda Auditiva Neurossensorial/tratamento farmacológico , Perda Auditiva Neurossensorial/etiologia , Perda Auditiva Neurossensorial/diagnóstico , Injeção Intratimpânica , Esteroides/uso terapêutico , Resultado do Tratamento , Glucocorticoides , Audiometria de Tons Puros
8.
Otol Neurotol ; 44(5): 453-461, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37167445

RESUMO

OBJECTIVE: Children with high-frequency severe-to-profound hearing loss and low-frequency residual hearing who do not derive significant benefit from hearing aids are now being considered for cochlear implantation. Previous research shows that hearing preservation is possible and may be desirable for the use of electroacoustic stimulation (EAS) in adults, but this topic remains underexplored in children. The goal of this study was to explore factors relating to hearing preservation, acceptance, and benefits of EAS for children. STUDY DESIGN: Retrospective review. SETTING: Tertiary academic medical center. PATIENTS: Forty children (48 ears) with preoperative low-frequency pure-tone averages of 75 dB HL or less at 250 and 500 Hz (n = 48). INTERVENTION: All patients underwent cochlear implantation with a standard-length electrode. MAIN OUTCOME MEASURE: Low-frequency audiometric thresholds, speech perception, and EAS usage were measured at initial stimulation, and 3 and 12 months postoperatively. Outcomes were compared between children with and without hearing preservation, and between EAS users and nonusers. RESULTS: Hearing was preserved at similar rates as adults but worse for children with an enlarged vestibular aqueduct. Fewer than half of children who qualified to use EAS chose to do so, citing a variety of audiologic and nonaudiologic reasons. No differences were detected in speech perception scores across the groups for words, sentences, or sentences in noise tests. CONCLUSIONS: Neither hearing preservation nor EAS use resulted in superior speech perception in children with preoperative residual hearing; rather, all children performed well after implantation.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Percepção da Fala , Adulto , Humanos , Criança , Estimulação Acústica/métodos , Resultado do Tratamento , Limiar Auditivo/fisiologia , Perda Auditiva Neurossensorial/cirurgia , Implante Coclear/métodos , Percepção da Fala/fisiologia , Audiometria de Tons Puros
9.
Ear Hear ; 44(5): 1014-1028, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36790447

RESUMO

OBJECTIVE: Minimally traumatic surgical techniques and advances in cochlear implant (CI) electrode array designs have allowed acoustic hearing present in a CI candidate prior to surgery to be preserved postoperatively. As a result, these patients benefit from combined electric-acoustic stimulation (EAS) postoperatively. However, 30% to 40% of EAS CI users experience a partial loss of hearing up to 30 dB after surgery. This additional hearing loss is generally not severe enough to preclude use of acoustic amplification; however, it can still impact EAS benefits. The use of electrocochleography (ECoG) measures of peripheral hair cell and neural auditory function have shed insight into the pathophysiology of postimplant loss of residual acoustic hearing. The present study aims to assess the long-term stability of ECoG measures and to establish ECoG as an objective method of monitoring residual hearing over the course of EAS CI use. We hypothesize that repeated measures of ECoG should remain stable over time for EAS CI users with stable postoperative hearing preservation. We also hypothesize that changes in behavioral audiometry for EAS CI users with loss of residual hearing should also be reflected in changes in ECoG measures. DESIGN: A pool of 40 subjects implanted under hearing preservation protocol was included in the study. Subjects were seen at postoperative visits for behavioral audiometry and ECoG recordings. Test sessions occurred 0.5, 1, 3, 6, 12 months, and annually after 12 months postoperatively. Changes in pure-tone behavioral audiometric thresholds relative to baseline were used to classify subjects into two groups: one group with stable acoustic hearing and another group with loss of acoustic hearing. At each test session, ECoG amplitude growth functions for several low-frequency stimuli were obtained. The threshold, slope, and suprathreshold amplitude at a fixed stimulation level was obtained from each growth function at each time point. Longitudinal linear mixed effects models were used to study trends in ECoG thresholds, slopes, and amplitudes for subjects with stable hearing and subjects with hearing loss. RESULTS: Preoperative, behavioral audiometry indicated that subjects had an average low-frequency pure-tone average (125 to 500 Hz) of 40.88 ± 13.12 dB HL. Postoperatively, results showed that ECoG thresholds and amplitudes were stable in EAS CI users with preserved residual hearing. ECoG thresholds increased (worsened) while ECoG amplitudes decreased (worsened) for those with delayed hearing loss. The slope did not distinguish between EAS CI users with stable hearing and subjects with delayed loss of hearing. CONCLUSIONS: These results provide a new application of postoperative ECoG as an objective tool to monitor residual hearing and understand the pathophysiology of delayed hearing loss. While our measures were conducted with custom-designed in-house equipment, CI companies are also designing and implementing hardware and software adaptations to conduct ECoG recordings. Thus, postoperative ECoG recordings can potentially be integrated into clinical practice.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva , Humanos , Estimulação Acústica , Audiometria de Resposta Evocada/métodos , Implante Coclear/métodos , Perda Auditiva/reabilitação , Surdez/reabilitação , Audiometria de Tons Puros , Limiar Auditivo , Estimulação Elétrica
10.
Ear Hear ; 44(4): 894-899, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36693145

RESUMO

OBJECTIVES: Systemic steroids are the most common first-line therapy in sudden sensorineural hearing loss (SSNHL), with significant improvement in hearing outcomes in over 60% of patients. It is unknown why 40% of patients do not respond to systemic steroid therapy. Salvage treatment includes intratympanic steroids (ITS) and hyperbaric oxygenation (HBO) therapy, with inconsistent results reported. This study aimed to compare the results of ITS and HBO therapy in patients with SSNHL that previously failed systemic steroid therapy. DESIGN: This is a comparative retrospective nonrandomized interventional cohort study, enrolling 126 patients with SSNHL. Out of these, 35 patients received HBO therapy, 43 patients received ITS, and 48 patients did not receive any second-line therapy (control group). Pure-tone audiograms were performed before and after the salvage therapy in the IT and HBO groups and at the same time interval in the control group. Study variables included age, time until therapy initiation, tinnitus status, and hearing outcomes, with a cutoff criteria of cumulative >30 dB improvement on all frequencies indicating recovery. RESULTS: ITS and HBO therapy were associated with statistically significant hearing recovery at all frequencies compared to systemic steroids. The results show an average hearing improvement of 13.6 dB overall frequencies (250 to 8000 Hz) after ITS therapy and 7.4 dB in HBO therapy in comparison to the control group. Presence of significant hearing improvement positively correlated with age, ITS therapy, and HBO therapy. Presence of tinnitus before therapy was negatively correlated with hearing improvement. Patients with tinnitus present at the start of therapy improve 4.67 dB less on average compared to those without tinnitus. ITS therapy significantly reduced tinnitus compared to the other two treatment options. Patients with tinnitus present before therapy significantly improve hearing at low frequencies, compared to the control group. CONCLUSIONS: ITS and HBO therapy show superior hearing results compared to observation alone after failed oral steroid therapy for SSNHL. ITS shows an additional positive impact on tinnitus reduction and shows superior hearing outcomes after salvage therapy.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Oxigenoterapia Hiperbárica , Zumbido , Humanos , Estudos Retrospectivos , Dexametasona , Oxigenoterapia Hiperbárica/métodos , Zumbido/terapia , Estudos de Coortes , Terapia de Salvação/métodos , Resultado do Tratamento , Audição , Perda Auditiva Súbita/terapia , Perda Auditiva Neurossensorial/terapia , Audiometria de Tons Puros/métodos
11.
Hear Res ; 427: 108663, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36502543

RESUMO

Noise exposure may damage the synapses that connect inner hair cells with auditory nerve fibers, before outer hair cells are lost. In humans, this cochlear synaptopathy (CS) is thought to decrease the fidelity of peripheral auditory temporal coding. In the current study, the primary hypothesis was that higher middle ear muscle reflex (MEMR) thresholds, as a proxy measure of CS, would be associated with smaller values of the binaural intelligibility level difference (BILD). The BILD, which is a measure of binaural temporal coding, is defined here as the difference in thresholds between the diotic and the antiphasic versions of the digits in noise (DIN) test. This DIN BILD may control for factors unrelated to binaural temporal coding such as linguistic, central auditory, and cognitive factors. Fifty-six audiometrically normal adults (34 females) aged 18 - 30 were tested. The test battery included standard pure tone audiometry, tympanometry, MEMR using a 2 kHz elicitor and 226 Hz and 1 kHz probes, the Noise Exposure Structured Interview, forward digit span test, extended high frequency (EHF) audiometry, and diotic and antiphasic DIN tests. The study protocol was pre-registered prior to data collection. MEMR thresholds did not predict the DIN BILD. Secondary analyses showed no association between MEMR thresholds and the individual diotic and antiphasic DIN thresholds. Greater lifetime noise exposure was non-significantly associated with higher MEMR thresholds, larger DIN BILD values, and lower (better) antiphasic DIN thresholds, but not with diotic DIN thresholds, nor with EHF thresholds. EHF thresholds were associated with neither MEMR thresholds nor any of the DIN outcomes, including the DIN BILD. Results provide no evidence that young, audiometrically normal people incur CS with impacts on binaural temporal processing.


Assuntos
Orelha Média , Reflexo , Feminino , Humanos , Adulto Jovem , Estimulação Acústica , Limiar Auditivo , Músculos , Audiometria de Tons Puros
12.
Clin Otolaryngol ; 48(2): 151-157, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36268807

RESUMO

OBJECTIVE: To evaluate the effect of Neurotec® herbal capsule (100 mg twice a day for 3 months) on the tinnitus symptoms in comparison with the placebo. DESIGN: A double-blind randomised clinical trial. SETTING: Otolaryngology clinic of Baqiyatallah Hospital. PARTICIPANTS: Patients suffering from subjective tinnitus. MAIN OUTCOME MEASURES: Pure tone audiometry was measured at .5, 1, 2, 4 and 6 kHz frequencies before and after the third month of intervention. In addition, Tinnitus Handicap Inventory (THI) questionnaire as well as visual analogue scale (VAS) for tinnitus loudness, daily annoyance, daily life or sleep disturbance, daily perception and mood alteration were evaluated. RESULTS: Finally, 103 (69 males and 34 females) patients with a mean age of 51.33 ± 13.91 years were analysed. In contrast with control group, patients in intervention group showed a remarkable decrease in THI score after 3 months of treatment (p < .05). Although both groups had improvements in VAS scores, mood disturbance, daily tinnitus perception and daily life alteration scores were only improved in the intervention group. The mean pure tone air and bone conduction were not significantly different between the control and the intervention group at baseline and 3 months after the intervention at .5, 1, 2 and 4 kHz (p > .05). CONCLUSION: A 3-month treatment with Neurotec capsules in addition to patient education is of benefit for managing symptoms in patients with chronic tinnitus.


Assuntos
Rosa , Zumbido , Urtica dioica , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Zumbido/diagnóstico , Audiometria de Tons Puros , Escala Visual Analógica
13.
Int J Audiol ; 62(10): 938-945, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35980257

RESUMO

OBJECTIVE: User-operated audiometry faces multiple barriers. One of these is the concern of audiologists that patients (non-experts) placing headphones by themselves results in invalid hearing thresholds due to greater placement variability. DESIGN: Comparative study. Participants took the AMTAS pure-tone air-conduction audiometry under two different conditions, expert and non-expert circumaural headphone placement for five frequencies within the range 250-8000 Hz. Questionnaires were also used to gain insight into the usability of the user-operated audiometry system - as well as the participants' perceived handling of the audiometry headphones. STUDY SAMPLE: Thirty participants (mean age 67.5 years). RESULTS: No statistically significant mean differences in hearing thresholds between the expert and non-expert conditions were found. The mean system usability scale score was 84.5. Handling the headphones was also rated as being easy (30%) or very easy (60%) by most non-experts. CONCLUSION: The conclusion of the study is that non-experts can be trusted to properly equip a pair of circumaural audiometry headphones for the correct conduction of pure-tone audiometry with only a few digital instructions.


Assuntos
Audiometria , Audição , Humanos , Idoso , Limiar Auditivo , Audiometria de Tons Puros/métodos , Estimulação Acústica , Inquéritos e Questionários
14.
Int J Audiol ; 62(2): 182-191, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35195500

RESUMO

OBJECTIVE: To monitor ototoxicity, air conduction (AC) extended high frequency (EHF) thresholds can be measured up to 16 kHz. However, conductive hearing loss might influence these results. This is unfortunate because the EHF thresholds are important to follow the impact of ototoxic medication during therapy. Therefore a suitable bone conduction (BC) transducer and norm values for EHF BC measurements are needed. DESIGN: In this study three different BC transducers were used: the B71 (Radioear), the KH70 (Präcitronic), and the KLH96 (Westra). Hearing thresholds were measured from 0.125 to 16 kHz using AC transducers (Telephonics TDH39, Sennheiser HDA200), and BC thresholds from 0.25 to 8 kHz with the B71, and from 0.25 to 16 kHz with the KLH96 and KH70. STUDY SAMPLE: 60 ears of 30 normal hearing subjects were measured. RESULTS: The KLH96 showed the highest output for the high frequencies, and distortion measurements were similar to the KH70. The results show that EHF measurements are possible using the KLH96 and KH70 bone conductors. CONCLUSION: EHF BC measurements are reliable when using the KLH96 and KH70 bone conductors. The extended force sensitivity of the used artificial mastoid should be determined for a proper EHF BC calibration.


Assuntos
Condução Óssea , Ototoxicidade , Humanos , Audiometria/métodos , Limiar Auditivo , Calibragem , Estimulação Acústica/métodos , Audiometria de Tons Puros , Transdutores
15.
Laryngoscope ; 133(2): 383-388, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35548932

RESUMO

OBJECTIVE: This study aimed to determine the optimal protocol of hyperbaric oxygen therapy (HBOT) according to various treatment settings for sudden sensorineural hearing loss (SSNHL). METHODS: A 112 patients with SSNHL were enrolled in this prospective study. All patients were treated with systemic steroid therapy, intratympanic steroid therapy, and HBOT. According to the pressure and duration of HBOT (10 sessions in total), the patients were divided into three groups: group 1, 2.5 atmospheres absolute (ATA) for 1 h; group 2, 2.5 ATA for 2 h; and group 3, 1.5 ATA for 1 h. The pure-tone average (PTA), word discrimination score (WDS), and mean gain were compared. RESULTS: A total of 105 patients completed the 3-month follow-up, and 6 patients were excluded. Differences among groups were found in PTA, WDS, and mean gain. In the post-hoc analysis, group 3 had significantly lower WDS and mean gain than groups 1 and 2; however, group 2 showed no significant differences from group 1. The proportion of patients with hearing recovery after treatment was significantly higher in group 1 (57.6%) and group 2 (58.8%) than in group 3 (31.3%). CONCLUSIONS: When HBOT (10 sessions) was combined with corticosteroids as the initial therapy for SSNHL, a higher pressure (1.5 ATA vs. 2.5 ATA) provided better treatment results; however, increasing the duration (1 h vs. 2 h) under 2.5 ATA did not result in a significant difference. Therefore, HBOT for SSNHL may be performed at 2.5 ATA for 1 h in 10 sessions. Laryngoscope, 133:383-388, 2023.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Oxigenoterapia Hiperbárica , Humanos , Oxigenoterapia Hiperbárica/métodos , Estudos Prospectivos , Perda Auditiva Neurossensorial/terapia , Perda Auditiva Súbita/terapia , Glucocorticoides/uso terapêutico , Resultado do Tratamento , Esteroides , Audiometria de Tons Puros
16.
Am J Audiol ; 31(4): 1279-1292, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36442042

RESUMO

PURPOSE: Normative auditory brainstem response (ABR) data for infants and young children are available for 0.25-4 kHz, limiting clinical assessment to this range. As such, the high-frequency hearing sensitivity of infants and young children remains unknown until behavioral testing can be completed, often not until late preschool or early school ages. The purpose of this study was to obtain normative ABR data at 6 and 8 kHz in young infants. METHOD: Participants were 173 full-term infants seen clinically for ABR testing at 0.4-6.7 months chronological age (M = 1.4 months, SD = 1.0), 97% of whom were ≤ 12 weeks chronological age. Stimuli included 6 and 8 kHz tone bursts presented at a rate of 27.7/s or 30.7/s using Blackman window gating with six cycles (6 kHz) or eight cycles (8 kHz) rise/fall time and no plateau. Presentation levels included 20, 40, and 60 dB nHL. The ABR threshold was estimated in 5- to 10-dB steps. RESULTS: As previously observed with lower frequency stimuli, ABR waveforms obtained in response to 6 and 8 kHz tone bursts decreased in latency with increasing intensity and increasing age. Latency was shorter for 8-kHz tone bursts than 6-kHz tone bursts. Data tables are presented for clinical reference for infants ≤ 4 weeks, 4.1-8 weeks, and 8.1-12 weeks chronological age including median ABR latency for Waves I, III, and V and the upper and lower boundaries of the 90% prediction interval. Interpeak Latencies I-III, III-V, and I-V are also reported. CONCLUSION: The results from this study demonstrate that ABR assessment at 6 and 8 kHz is feasible for young infants within a standard clinical appointment and provide reference data for clinical interpretation of ABR waveforms for frequencies above 4 kHz.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Audição , Lactente , Criança , Humanos , Pré-Escolar , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Audiometria de Tons Puros/métodos , Limiar Auditivo/fisiologia , Audição/fisiologia , Estimulação Acústica/métodos
17.
Orv Hetil ; 163(42): 1682-1689, 2022 Oct 16.
Artigo em Húngaro | MEDLINE | ID: mdl-36244011

RESUMO

Introduction: Tinnitus is a sound without an external sound stimulus, usually only perceived by the sufferer. Inner ear damage might be found in its background, although many other possible causes exist. Therefore, there is a need for a detailed examination in all cases. Method: In the present investigation, 100 patients (38 men, 62 women; mean age +/- SD: 59 years +/- 11.3) suffering from tinnitus were enrolled. The data and examination results of these patients were analysed in detail. The outcomes of the brain MRI, carotid-vertebral ultrasound, cervical X-ray, pure-tone audiometry, and tinnitometry were analyzed regarding the detailed examinations. Results: In terms of tinnitus laterality, left-sided (34%) and both-sided (53%) were the most frequent ones. The frequency of the examinations was the following: audiometry and tinnitometry (100%), cervical X-ray (80%), cerebral MRI (76%) and carotid-vertebral Doppler ultrasound (21%). Cervical spondylosis/spondyloarthrosis (69 patients), vascular encephalopathy (56 patients) and atherosclerosis of the carotid artery (20 patients) were observed as the most common aberrations. Using the audiometry, normal hearing was detected in 14%, slight sensorineural hearing loss in 25%, moderate sensorineural hearing loss in 44% and severe sensorineural hearing loss in 17%. Tinnitometry detected tinnitus with a mean frequency of 4200 +/- 2200 Hz and intensity of 40 +/- 14.4 dB. Conclusion: The detailed examination of patients suffering from tinnitus is essential in multidisciplinary therapy planning. Possible complications in other organs can also be detected using the carotid-vertebral ultrasound as screening method. Based on the cervical X-ray, the somatosensory tinnitus form can be observed. Pure-tone audiometry and tinnitometry help detect hearing loss combined with tinnitus, pitch, and loudness, which are also essential in therapy planning.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva , Zumbido , Estimulação Acústica , Audiometria de Tons Puros/efeitos adversos , Audiometria de Tons Puros/métodos , Feminino , Perda Auditiva Neurossensorial/diagnóstico , Humanos , Masculino , Zumbido/diagnóstico , Zumbido/etiologia , Zumbido/terapia
18.
Lasers Med Sci ; 37(9): 3485-3494, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35947315

RESUMO

To verify the effect of photobiomodulation therapy (PBMT) in individuals with chronic tinnitus without hearing loss, 20 patients who met the inclusion criteria were randomly divided into group 1: active low-level laser (LLL) and group 2: equipment without laser (placebo). Upon anamnesis, data collection, and audiological exams, the Tinnitus Handicap Inventory (THI) and the Visual-Analog Scale (EVA) were applied to measure the level of discomfort with tinnitus and the level of discomfort before and after laser treatment. The protocol used included 12 active LLL sessions for group 1 and not active for group 2, varying red and infrared wavelengths. There was a reduction in the disadvantage of individuals with tinnitus after the intervention and between the initial and final sessions, regardless of the intervention, although group 1 showed a greater reduction than group 2, regardless of point in time of assessment and number of session. There was no statistical difference as to group and point in time for the high-frequency audiometry and acuphenometry outcomes. Individuals with chronic tinnitus reduced the complaint, regardless of point in time and group of intervention; however, the group that received PBMT improved the level of satisfaction, regardless of point in time of assessment and number of session.


Assuntos
Perda Auditiva , Terapia com Luz de Baixa Intensidade , Zumbido , Humanos , Zumbido/radioterapia , Audiometria de Tons Puros , Escala Visual Analógica
19.
Acta Otolaryngol ; 142(6): 509-514, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35791801

RESUMO

BACKGROUND: The short- and long-term effects of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection on the medial olivocochlear reflex and outer hair cells in the cochlea remain largely unclear. AIMS: The aim of this study was to investigate the efferent auditory system effects in adult patients with COVID-19. MATERIALS AND METHODS: The study included 18-50 years old 44 volunteers: 26 individuals (52 ears) with COVID-19 in the study group and 18 healthy individuals (36 ears) in the control group. Otolaryngological examination, immitancemetric evaluation, distortion product otoacoustic emission (DPOAE), contralateral acoustic stimulation with DPOAE, audiometric evaluation, and high frequency audiometric evaluation were performed in all individuals participating in the study. RESULTS: In our study, patients with COVID-19 had significantly lower DPOAE results with or without broadband noise at only 6 kHz frequency and contralateral suppression results at all frequencies compared to healthy individuals. A statistically significant difference was found between the study and control groups according to whether the participants had a response in the high frequency audiometry at 12 and 16 kHz frequencies. CONCLUSIONS: COVID-19 affects many systems in the body. As a result of the findings obtained in the present study, it is shown that the auditory efferent system may also be affected.


Assuntos
COVID-19 , Estimulação Acústica , Adolescente , Adulto , Audiometria de Tons Puros , Cóclea/fisiologia , Transtornos da Audição , Humanos , Pessoa de Meia-Idade , Emissões Otoacústicas Espontâneas/fisiologia , SARS-CoV-2 , Adulto Jovem
20.
Eur Arch Otorhinolaryngol ; 279(12): 5885-5895, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35763084

RESUMO

PURPOSE: In the present study, a new procedure to perform automatic audiometry using multifrequency Auditory Steady-State Response (ASSR) is proposed. METHODS: The automatic audiometry procedure consists of detecting the presence of multifrequency ASSR in real-time using the sequential test strategy and by adjusting the stimulus intensity independently. The ASSR audiometric thresholds of 18 adult volunteers with normal hearing were determined by automatically (four simultaneous frequencies per ear) at modulation frequencies in the 80 Hz range. The exam time and the difference between ASSR thresholds and pure-tone behavioural hearing thresholds were estimated as performance measures. RESULTS: The results showed that automatic audiometry can reduce the number of intensity levels used to obtain the ASSR threshold by up to 58% when compared to audiometry without using the techniques applied in automatic audiometry. In addition, the average of the difference between ASSR thresholds and Pure-Tone Behavioural Hearing thresholds was around 19 dB, which is similar to the results reported in similar studies. CONCLUSIONS: The audiometric procedure proposed in this study is fully automatic, i.e., does not require any human supervision throughout the exam, and is able to significantly reduce the conventional exam time.


Assuntos
Audiometria de Resposta Evocada , Audição , Adulto , Humanos , Audiometria de Tons Puros/métodos , Audiometria de Resposta Evocada/métodos , Limiar Auditivo/fisiologia , Audição/fisiologia , Voluntários , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Estimulação Acústica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA