Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 170
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Fa Yi Xue Za Zhi ; 40(1): 15-19, 2024 Feb 25.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38500456

RESUMO

OBJECTIVES: To study the application of CE-Chirp in the evaluation of hearing impairment in forensic medicine by testing the auditory brainstem response (ABR) in adults using CE-Chirp to analyze the relationship between the V-wave response threshold of CE-Chirp ABR test and the pure tone hearing threshold. METHODS: Subjects (aged 20-77 with a total of 100 ears) who underwent CE-Chirp ABR test in Changzhou De'an Hospital from January 2018 to June 2019 were selected to obtain the V-wave response threshold, and pure tone air conduction hearing threshold tests were conducted at 0.5, 1.0, 2.0 and 4.0 kHz, respectively, to obtain pure tone listening threshold. The differences and statistical differences between the average pure tone hearing threshold and V-wave response threshold were compared in different hearing levels and different age groups. The correlation, differences and statistical differences between the two tests at each frequency were analyzed for all subjects. The linear regression equation for estimating pure tone hearing threshold for all subjects CE-Chirp ABR V-wave response threshold was established, and the feasibility of the equation was tested. RESULTS: There was no statistical significance in the CE-Chirp ABR response threshold and pure tone hearing threshold difference between different hearing level groups and different age groups (P>0.05). There was a good correlation between adult CE-Chirp ABR V-wave response threshold and pure tone hearing threshold with statistical significance (P<0.05), and linear regression analysis showed a significant linear correlation between the two (P<0.05). CONCLUSIONS: The use of CE-Chirp ABR V-wave response threshold can be used to evaluate subjects' pure tone hearing threshold under certain conditions, and can be used as an audiological test method for forensic hearing impairment assessment.


Assuntos
Perda Auditiva , Audição , Adulto , Humanos , Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Audição/fisiologia , Perda Auditiva/diagnóstico , Audiometria de Tons Puros/métodos , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia
2.
Ear Hear ; 44(4): 894-899, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36693145

RESUMO

OBJECTIVES: Systemic steroids are the most common first-line therapy in sudden sensorineural hearing loss (SSNHL), with significant improvement in hearing outcomes in over 60% of patients. It is unknown why 40% of patients do not respond to systemic steroid therapy. Salvage treatment includes intratympanic steroids (ITS) and hyperbaric oxygenation (HBO) therapy, with inconsistent results reported. This study aimed to compare the results of ITS and HBO therapy in patients with SSNHL that previously failed systemic steroid therapy. DESIGN: This is a comparative retrospective nonrandomized interventional cohort study, enrolling 126 patients with SSNHL. Out of these, 35 patients received HBO therapy, 43 patients received ITS, and 48 patients did not receive any second-line therapy (control group). Pure-tone audiograms were performed before and after the salvage therapy in the IT and HBO groups and at the same time interval in the control group. Study variables included age, time until therapy initiation, tinnitus status, and hearing outcomes, with a cutoff criteria of cumulative >30 dB improvement on all frequencies indicating recovery. RESULTS: ITS and HBO therapy were associated with statistically significant hearing recovery at all frequencies compared to systemic steroids. The results show an average hearing improvement of 13.6 dB overall frequencies (250 to 8000 Hz) after ITS therapy and 7.4 dB in HBO therapy in comparison to the control group. Presence of significant hearing improvement positively correlated with age, ITS therapy, and HBO therapy. Presence of tinnitus before therapy was negatively correlated with hearing improvement. Patients with tinnitus present at the start of therapy improve 4.67 dB less on average compared to those without tinnitus. ITS therapy significantly reduced tinnitus compared to the other two treatment options. Patients with tinnitus present before therapy significantly improve hearing at low frequencies, compared to the control group. CONCLUSIONS: ITS and HBO therapy show superior hearing results compared to observation alone after failed oral steroid therapy for SSNHL. ITS shows an additional positive impact on tinnitus reduction and shows superior hearing outcomes after salvage therapy.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva Súbita , Oxigenoterapia Hiperbárica , Zumbido , Humanos , Estudos Retrospectivos , Dexametasona , Oxigenoterapia Hiperbárica/métodos , Zumbido/terapia , Estudos de Coortes , Terapia de Salvação/métodos , Resultado do Tratamento , Audição , Perda Auditiva Súbita/terapia , Perda Auditiva Neurossensorial/terapia , Audiometria de Tons Puros/métodos
3.
Int J Audiol ; 62(10): 938-945, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35980257

RESUMO

OBJECTIVE: User-operated audiometry faces multiple barriers. One of these is the concern of audiologists that patients (non-experts) placing headphones by themselves results in invalid hearing thresholds due to greater placement variability. DESIGN: Comparative study. Participants took the AMTAS pure-tone air-conduction audiometry under two different conditions, expert and non-expert circumaural headphone placement for five frequencies within the range 250-8000 Hz. Questionnaires were also used to gain insight into the usability of the user-operated audiometry system - as well as the participants' perceived handling of the audiometry headphones. STUDY SAMPLE: Thirty participants (mean age 67.5 years). RESULTS: No statistically significant mean differences in hearing thresholds between the expert and non-expert conditions were found. The mean system usability scale score was 84.5. Handling the headphones was also rated as being easy (30%) or very easy (60%) by most non-experts. CONCLUSION: The conclusion of the study is that non-experts can be trusted to properly equip a pair of circumaural audiometry headphones for the correct conduction of pure-tone audiometry with only a few digital instructions.


Assuntos
Audiometria , Audição , Humanos , Idoso , Limiar Auditivo , Audiometria de Tons Puros/métodos , Estimulação Acústica , Inquéritos e Questionários
4.
Am J Audiol ; 31(4): 1279-1292, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36442042

RESUMO

PURPOSE: Normative auditory brainstem response (ABR) data for infants and young children are available for 0.25-4 kHz, limiting clinical assessment to this range. As such, the high-frequency hearing sensitivity of infants and young children remains unknown until behavioral testing can be completed, often not until late preschool or early school ages. The purpose of this study was to obtain normative ABR data at 6 and 8 kHz in young infants. METHOD: Participants were 173 full-term infants seen clinically for ABR testing at 0.4-6.7 months chronological age (M = 1.4 months, SD = 1.0), 97% of whom were ≤ 12 weeks chronological age. Stimuli included 6 and 8 kHz tone bursts presented at a rate of 27.7/s or 30.7/s using Blackman window gating with six cycles (6 kHz) or eight cycles (8 kHz) rise/fall time and no plateau. Presentation levels included 20, 40, and 60 dB nHL. The ABR threshold was estimated in 5- to 10-dB steps. RESULTS: As previously observed with lower frequency stimuli, ABR waveforms obtained in response to 6 and 8 kHz tone bursts decreased in latency with increasing intensity and increasing age. Latency was shorter for 8-kHz tone bursts than 6-kHz tone bursts. Data tables are presented for clinical reference for infants ≤ 4 weeks, 4.1-8 weeks, and 8.1-12 weeks chronological age including median ABR latency for Waves I, III, and V and the upper and lower boundaries of the 90% prediction interval. Interpeak Latencies I-III, III-V, and I-V are also reported. CONCLUSION: The results from this study demonstrate that ABR assessment at 6 and 8 kHz is feasible for young infants within a standard clinical appointment and provide reference data for clinical interpretation of ABR waveforms for frequencies above 4 kHz.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Audição , Lactente , Criança , Humanos , Pré-Escolar , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Audiometria de Tons Puros/métodos , Limiar Auditivo/fisiologia , Audição/fisiologia , Estimulação Acústica/métodos
5.
Orv Hetil ; 163(42): 1682-1689, 2022 Oct 16.
Artigo em Húngaro | MEDLINE | ID: mdl-36244011

RESUMO

Introduction: Tinnitus is a sound without an external sound stimulus, usually only perceived by the sufferer. Inner ear damage might be found in its background, although many other possible causes exist. Therefore, there is a need for a detailed examination in all cases. Method: In the present investigation, 100 patients (38 men, 62 women; mean age +/- SD: 59 years +/- 11.3) suffering from tinnitus were enrolled. The data and examination results of these patients were analysed in detail. The outcomes of the brain MRI, carotid-vertebral ultrasound, cervical X-ray, pure-tone audiometry, and tinnitometry were analyzed regarding the detailed examinations. Results: In terms of tinnitus laterality, left-sided (34%) and both-sided (53%) were the most frequent ones. The frequency of the examinations was the following: audiometry and tinnitometry (100%), cervical X-ray (80%), cerebral MRI (76%) and carotid-vertebral Doppler ultrasound (21%). Cervical spondylosis/spondyloarthrosis (69 patients), vascular encephalopathy (56 patients) and atherosclerosis of the carotid artery (20 patients) were observed as the most common aberrations. Using the audiometry, normal hearing was detected in 14%, slight sensorineural hearing loss in 25%, moderate sensorineural hearing loss in 44% and severe sensorineural hearing loss in 17%. Tinnitometry detected tinnitus with a mean frequency of 4200 +/- 2200 Hz and intensity of 40 +/- 14.4 dB. Conclusion: The detailed examination of patients suffering from tinnitus is essential in multidisciplinary therapy planning. Possible complications in other organs can also be detected using the carotid-vertebral ultrasound as screening method. Based on the cervical X-ray, the somatosensory tinnitus form can be observed. Pure-tone audiometry and tinnitometry help detect hearing loss combined with tinnitus, pitch, and loudness, which are also essential in therapy planning.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva , Zumbido , Estimulação Acústica , Audiometria de Tons Puros/efeitos adversos , Audiometria de Tons Puros/métodos , Feminino , Perda Auditiva Neurossensorial/diagnóstico , Humanos , Masculino , Zumbido/diagnóstico , Zumbido/etiologia , Zumbido/terapia
6.
Eur Arch Otorhinolaryngol ; 279(12): 5885-5895, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35763084

RESUMO

PURPOSE: In the present study, a new procedure to perform automatic audiometry using multifrequency Auditory Steady-State Response (ASSR) is proposed. METHODS: The automatic audiometry procedure consists of detecting the presence of multifrequency ASSR in real-time using the sequential test strategy and by adjusting the stimulus intensity independently. The ASSR audiometric thresholds of 18 adult volunteers with normal hearing were determined by automatically (four simultaneous frequencies per ear) at modulation frequencies in the 80 Hz range. The exam time and the difference between ASSR thresholds and pure-tone behavioural hearing thresholds were estimated as performance measures. RESULTS: The results showed that automatic audiometry can reduce the number of intensity levels used to obtain the ASSR threshold by up to 58% when compared to audiometry without using the techniques applied in automatic audiometry. In addition, the average of the difference between ASSR thresholds and Pure-Tone Behavioural Hearing thresholds was around 19 dB, which is similar to the results reported in similar studies. CONCLUSIONS: The audiometric procedure proposed in this study is fully automatic, i.e., does not require any human supervision throughout the exam, and is able to significantly reduce the conventional exam time.


Assuntos
Audiometria de Resposta Evocada , Audição , Adulto , Humanos , Audiometria de Tons Puros/métodos , Audiometria de Resposta Evocada/métodos , Limiar Auditivo/fisiologia , Audição/fisiologia , Voluntários , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Estimulação Acústica
7.
J Laryngol Otol ; 134(12): 1044-1051, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33153510

RESUMO

OBJECTIVE: Binaural hearing is facilitated by neural interactions in the auditory pathway. Ageing results in impairment of localisation and listening in noisy situations without any significant hearing loss. The present study focused on comparing the binaural encoding of a speech stimulus at the subcortical level in middle-aged versus younger adults, based on speech-evoked auditory brainstem responses. METHODS: Thirty participants (15 young adults and 15 middle-aged adults) with normal hearing sensitivity (less than 15 dB HL) participated in the study. The speech-evoked auditory brainstem response was recorded monaurally and binaurally with a 40-ms /da/ stimulus. Fast Fourier transform analysis was utilised. RESULTS: An independent sample t-test revealed a significant difference between the two groups in fundamental frequency (F0) amplitude recorded with binaural stimulation. CONCLUSION: The present study suggested that ageing results in degradation of F0 encoding, which is essential for the perception of speech in noise.


Assuntos
Estimulação Acústica/métodos , Tronco Encefálico/fisiologia , Perda Auditiva/diagnóstico , Percepção da Fala/fisiologia , Adolescente , Adulto , Idoso , Envelhecimento , Audiometria de Tons Puros/métodos , Vias Auditivas/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Análise de Fourier , Testes Auditivos/métodos , Humanos , Pessoa de Meia-Idade , Ruído/efeitos adversos , Adulto Jovem
8.
Int Tinnitus J ; 23(1): 52-57, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31469529

RESUMO

OBJECTIVES: To evaluate the efficacy and safety of low-level light therapy (LLLT) using new irradiation parameters for chronic unilateral tinnitus with cochlear dysfunction. DESIGN: A single-blind, randomized clinical trial. SETTING: Tertiary-care hospital center. PARTICIPANTS: Participants who had a history of chronic unilateral tinnitus (≥ 3 months) and pure-tone thresholds greater than 15dB (averaged for 3k, 4k, and 6k Hz). MAIN OUTCOME MEASURES: Numerical rating scales (NRS) measuring loudness, duration, and annoyance, the tinnitus handicap inventory (THI), and psychoacoustical matches of tinnitus loudness and minimum masking levels (MML). RESULTS: Thirty-eight participants were received either a 100-mW diode laser at 830-nm (TINI group; n=19) or placebo (sham group; n=19) irradiation through the tympanic membrane. No adverse events were reported during 2 weeks of 10-interventions (20 minutes/day, five days/week). The NRS measuring duration of tinnitus and psychoacoustical matches of tinnitus loudness significantly decreased over times in the TINI group (p<0.05). However, post-hoc analysis revealed that there was no significant decrease of tinnitus among different time points (baseline, during LLLT, immediately after LLLT, and two weeks after LLLT). There was no placebo effect in the Sham group. Participants who improved the duration by at least one point or improved the loudness matches by more than 5 dB SL two weeks after LLLT tended to have worse pure-tone thresholds. It may suggest that further study is needed in patients with worse pure-tone thresholds to evaluate the therapeutic efficacy of LLLT. CONCLUSION: Although this preliminary result is insufficient to support the therapeutic efficacy of new laser device for chronic tinnitus, further study is needed in a large number of selected patients.


Assuntos
Avaliação da Deficiência , Terapia com Luz de Baixa Intensidade/métodos , Segurança do Paciente , Qualidade de Vida , Zumbido/radioterapia , Audiometria de Tons Puros/métodos , Doença Crônica , Feminino , Seguimentos , Humanos , Masculino , Valores de Referência , Medição de Risco , Método Simples-Cego , Zumbido/diagnóstico , Zumbido/psicologia , Resultado do Tratamento
9.
Int Tinnitus J ; 23(1): 58-63, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31469530

RESUMO

The aim the present study is to evaluate ocular and cervical Vestibular Evoked Myogenic Potentials (VEMPs) of adult individuals with and without tinnitus who have normal hearing. Thirty one patients who have normal hearing, complaining about unilateral or bilateral subjective tinnitus and 30 volunteers who without tinnitus and vestibular complains were enrolled into the present study. Following examination by of Ear Nose Throat (ENT) physician, Tinnitus Disability Questionnaire (TDQ), pure tone audiometry (125-16.000 Hz) speech tests, oVEMP and cVEMP tests were applied to all participants. Fourteen individuals with normal hearing and tinnitus were male (44%) and 17 (56%) were female with an age average of 35.8 ± 10.2.30 years; the control group consisted of 16 males (53%) and 14 females (47%) with an age average of 37.5 ± 12 years. Two individuals of the tinnitus group had bilateral tinnitus and 29 individuals had unilateral tinnitus. A statistically significant difference in individuals without tinnitus and tinnitus must be normal at work between test answers that are not available 125-16000 Hz range Air Conduction (AC) hearing thresholds, speech tests, cVEMP and oVEMP responses. Tinnitus may appear due to many reasons. Vestibular system is one of the conditions that can cause tinnitus. According to the findings obtained from adult individuals with normal hearing, the vestibular system does not cause tinnitus.


Assuntos
Estimulação Acústica/métodos , Avaliação da Deficiência , Zumbido/diagnóstico , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Adulto , Audiometria de Tons Puros/métodos , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Padrões de Referência , Medição de Risco , Índice de Gravidade de Doença , Inquéritos e Questionários , Testes de Função Vestibular
10.
J Int Adv Otol ; 15(1): 56-61, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31058596

RESUMO

OBJECTIVES: The recurrence rate of sudden sensorineural hearing loss (SSNHL) varies from 0.8% to 40%. However, to the best of our knowledge, no data on long-term hearing variations are present in the literature. The aim of this observational study was to analyze long-term variations of the hearing threshold in unilateral SSNHL without recurrence. MATERIALS AND METHODS: A total of 50 patients affected by unilateral SSNHL were evaluated. Patients underwent a treatment consisting of intravenous corticosteroids. Clinical and audiometric features were recorded. Patients underwent pure tone audiometry at a mean follow-up of 5.26±2.28 years. Differences between the affected and unaffected ear were analyzed. RESULTS: Comparing the post-treatment and follow-up audiograms, there was a worsening of hearing in the unaffected ear. On the contrary, no significant difference over time was found for the affected ear. 54% of patients showed no changes over time, 26% showed worsening, and 20% showed an improvement in hearing. The variation correlated with alcohol consumption and the presence of vasculopathies. An average improvement of hearing over time was observed at low frequencies. CONCLUSION: The time evolution in SSNHL is not predictable on the basis of the clinical and audiometric data. The majority the patients shows no changes in hearing loss in the affected ear. Patients who consume alcohol or have vasculopathies also have a higher risk of worsening of hearing. Further prospective studies are mandatory to better assess variations over time and their relationship with the effect of aging on hearing.


Assuntos
Audiometria de Tons Puros/métodos , Limiar Auditivo/fisiologia , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Súbita/fisiopatologia , Administração Intravenosa , Corticosteroides/administração & dosagem , Corticosteroides/uso terapêutico , Adulto , Idoso , Consumo de Bebidas Alcoólicas/efeitos adversos , Feminino , Seguimentos , Audição/efeitos dos fármacos , Audição/fisiologia , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Súbita/diagnóstico , Perda Auditiva Súbita/tratamento farmacológico , Humanos , Oxigenoterapia Hiperbárica/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Doenças Vasculares/complicações , Doenças Vasculares/epidemiologia
11.
Eur Arch Otorhinolaryngol ; 276(8): 2171-2180, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31115686

RESUMO

OBJECTIVES: Even though many patients undergoing auditory steady-state response (ASSR) testing have some degree of hearing loss, some have normal hearing and ASSR often overestimates the behavioral thresholds in this group. In most commercial ASSR systems such as Chartr EP, a default correction factor is applied to compensate for this difference. Little is known, however, as how the correction factor compensates for the difference between ASSR and pure tone audiometry (PTA) thresholds as a function of carrier or modulation frequency (MF) in a commercial ASSR system. Our goal is to evaluate this relationship. METHODS: Twenty-four normal hearing adults were examined for both PTA and ASSR (Chartr EP system, GN Otometrics). ASSR thresholds were obtained at three MFs (20, 40, and 80 Hz). The difference scores were obtained by subtracting PTA from ASSR thresholds at each frequency for each subject. The corrected ASSR thresholds, then, were compared with the PTA thresholds across MFs and carrier frequencies. RESULTS: The default correction factors in the ASSR equipment differed significantly from the difference scores at all MFs and carrier frequencies (n = 24, p < 0.005). The correlation between corrected ASSR and PTA thresholds at most MFs and carrier frequencies were medium to poor. CONCLUSIONS: At most MFs and carrier frequencies, the default correction factors defined by the manufacturer do not compensate for the difference between ASSR and PTA thresholds in normal hearing adults. The use of the default correction factors in Chartr EP system for the normal hearing adults needs special considerations.


Assuntos
Audiometria de Tons Puros , Limiar Auditivo/fisiologia , Perda Auditiva , Estimulação Acústica/métodos , Adulto , Audiometria de Tons Puros/instrumentação , Audiometria de Tons Puros/métodos , Audiometria de Tons Puros/psicologia , Feminino , Voluntários Saudáveis , Perda Auditiva/diagnóstico , Perda Auditiva/fisiopatologia , Perda Auditiva/psicologia , Humanos , Masculino , Motivação , Projetos de Pesquisa
12.
Eur Arch Otorhinolaryngol ; 276(6): 1643-1647, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30949825

RESUMO

INTRODUCTION: As average life-expectancy increases, a sufficient hearing rehabilitation for elderly patients with severe-to-profound sensorineural hearing loss becomes more important. Cochlear implantation is a relatively safe surgical procedure also for elderly patients, the higher risk is caused by general anesthesia. We report on four patients who underwent cochlear implantation under local anesthesia. METHODS: After detailed preoperative examinations (audiological tests, imaging, genetic tests, evaluation of motivation and compliance of the patient), four patient with severe-to-profound hearing loss were selected for cochlear implantation under local anesthesia. For the electrode insertion, we used the posterior suprameatal approach technique. Pre- and postoperative pure tone audiometry and speech-perception tests were conducted to prove the success of the procedure. RESULTS: The mentioned technique was applied; the average length of the operation was 52 min. The intraoperative measurements showed normal impedance and normal neuronal response telemetry, all the patients had sound experience during the intraoperative examination of the engineer. No complications were observed. The postoperative audiological tests showed a significant increase in the hearing perception. CONCLUSION: Cochlear implantation under local anesthesia is a safe and fast procedure for elderly patients. The intraoperative sound experience can give an extra motivation in the postoperative rehabilitation. Our results prove that by carefully selected elderly patients cochlear implantation can assure a significant increase in speech perception. We can establish that the new posterior suprameatal approach technique combined with local anesthesia presents a viable future option for those patients who were inoperable beforehand because of high risks of general anesthesia.


Assuntos
Anestesia Local/métodos , Implante Coclear/métodos , Perda Auditiva Neurossensorial , Idoso , Audiometria de Tons Puros/métodos , Feminino , Perda Auditiva Neurossensorial/etiologia , Perda Auditiva Neurossensorial/psicologia , Perda Auditiva Neurossensorial/cirurgia , Humanos , Masculino , Seleção de Pacientes , Percepção da Fala , Resultado do Tratamento
13.
J Int Adv Otol ; 15(1): 87-93, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30924771

RESUMO

OBJECTIVES: This study uses a new approach for classifying the human ethnicity according to the auditory brain responses (electroencephalography [EEG] signals) with a high level of accuracy. Moreover, the study presents three different algorithms used to classify the human ethnicity using auditory brain responses. The algorithms were tested on Malays and Chinese as a case study. MATERIALS AND METHODS: The EEG signal was used as a brain response signal, which was evoked by two auditory stimuli (Tones and Consonant Vowels stimulus). The study was carried out on Malaysians (Malay and Chinese) with normal hearing and with hearing loss. A ranking process for the subjects' EEG data and the nonlinear features was used to obtain the maximum classification accuracy. RESULTS: The study formulated the classification of Normal Hearing Ethnicity Index and Sensorineural Hearing Loss Ethnicity Index. These indices classified the human ethnicity according to brain auditory responses by using numerical values of response signal features. Three classification algorithms were used to verify the human ethnicity. Support Vector Machine (SVM) classified the human ethnicity with an accuracy of 90% in the cases of normal hearing and sensorineural hearing loss (SNHL); the SVM classified with an accuracy of 84%. CONCLUSION: The classification indices categorized or separated the human ethnicity in both hearing cases of normal hearing and SNHL with high accuracy. The SVM classifier provided a good accuracy in the classification of the auditory brain responses. The proposed indices might constitute valuable tools for the classification of the brain responses according to the human ethnicity.


Assuntos
Eletroencefalografia/instrumentação , Potenciais Evocados Auditivos/fisiologia , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva/fisiopatologia , Estimulação Acústica/métodos , Adulto , Algoritmos , Audiometria de Tons Puros/métodos , China/epidemiologia , China/etnologia , Etnicidade/estatística & dados numéricos , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/etnologia , Humanos , Idioma , Malásia/etnologia , Masculino , Pessoa de Meia-Idade , Ruído/efeitos adversos , Percepção da Fala/fisiologia , Máquina de Vetores de Suporte/normas
14.
Brain Behav ; 9(4): e01242, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30895749

RESUMO

INTRODUCTION: Some tinnitus subjects habituate to their tinnitus but some others do not and complain of its annoyance tremendously. Normal sensory memory and change detection processes are needed for detecting the tinnitus signal as a prediction error and habituation to tinnitus. The purpose of this study was to compare auditory mismatch negativity as the index of sensory memory and change detection among the studied groups to search for the factors involving in the perception of tinnitus and preventing habituation in decompensated tinnitus subjects. METHODS: Electroencephalography was recorded from scalp electrodes in compensated tinnitus, decompensated tinnitus, and no tinnitus control subjects. Mismatch negativity was obtained using the oddball paradigm with frequency, duration, and silent gap deviants. Amplitude, latency, and area under the curve of mismatch negativities were compared among the three studied groups. RESULTS: The results showed lower mismatch negativity amplitude and area under the curve for the higher frequency deviant and for the silent gap deviant in decompensated tinnitus group compared to normal control and compensated tinnitus group. CONCLUSIONS: This study revealed a deficit in sensory memory and change detection processing in decompensated tinnitus subjects. This causes persistent prediction errors; tinnitus signal is consistently detected as a new signal and activates the brain salience network and consequently prevents habituation to tinnitus. Mismatch negativity is proposed as an index for monitoring tinnitus rehabilitation.


Assuntos
Percepção Auditiva/fisiologia , Zumbido/fisiopatologia , Estimulação Acústica/métodos , Adulto , Audiometria de Tons Puros/métodos , Encéfalo/fisiologia , Eletroencefalografia , Potenciais Evocados Auditivos/fisiologia , Feminino , Humanos , Masculino , Memória/fisiologia
15.
Ann Otol Rhinol Laryngol ; 128(1): 50-55, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30345805

RESUMO

OBJECTIVES:: The aim of this study was to assess the feasibility and safety of ossiculoplasty under local anesthesia in an office setting without sedation. METHODS:: Between May 2017 and November 2017, patients who presented with conductive hearing loss and known isolated ossicular discontinuities were offered ossiculoplasty under local anesthesia. Inclusion criteria included age ⩾ 18 years, adequate transcanal access, and the ability to lie supine for up to 45 minutes. Exclusion criteria included associated tympanic membrane perforation and the presence of middleear or mastoid cholesteatoma or infection. RESULTS:: Fourteen patients underwent the procedure. The mean age was 48.3 years (range, 19-74 years). Six were primary and 8 revision cases. There were 8 partial and 6 total prosthesis placements. The mean operative time was 34 minutes (range, 26-43 minutes). All patients tolerated the procedure to completion. There were no intraoperative complications. The mean air conduction pure-tone average was 76.6 dB and the mean bone conduction pure-tone average was 27.2 dB, with a preoperative air-bone gap of 49.9 dB. Air conduction pure-tone average significantly improved to 45.2 dB ( P < .0001). Air-bone gap significantly improved to 17.8 dB ( P < .0001). CONCLUSIONS:: Ossiculoplasty using partial or total prostheses can be safely performed in the office setting under local anesthesia without sedation in carefully selected patients. This has potentially significant patient and system benefits.


Assuntos
Procedimentos Cirúrgicos Ambulatórios/métodos , Ossículos da Orelha/cirurgia , Perda Auditiva Condutiva/cirurgia , Substituição Ossicular , Complicações Pós-Operatórias , Timpanoplastia , Anestesia Local/métodos , Audiometria de Tons Puros/métodos , Condução Óssea , Estudos de Viabilidade , Feminino , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Substituição Ossicular/efeitos adversos , Substituição Ossicular/métodos , Projetos Piloto , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/cirurgia , Reoperação/métodos , Resultado do Tratamento , Timpanoplastia/efeitos adversos , Timpanoplastia/métodos
16.
Am J Audiol ; 27(3): 368-369, 2018 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-30178035

RESUMO

PURPOSE: The purpose of this letter is to respond to Dr. Peck's (2018) letter to the editor regarding the use of the term "nonorganic" to describe hearing loss, demonstrated by the pure tone audiogram that cannot be explained or is greater than what can be explained by a physiological auditory disorder. CONCLUSIONS: We prefer the term "nonorganic" rather than the term "false and exaggerated hearing loss." "Nonorganic," in our view, is a nonjudgmental term and, as stated by Austen and Lynch (2004), implies "as little as possible about its cause" (p. 450).


Assuntos
Estimulação Acústica/métodos , Audiometria de Tons Puros/métodos , Limiar Auditivo/fisiologia , Perda Auditiva Funcional/diagnóstico , Terminologia como Assunto , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
17.
J Speech Lang Hear Res ; 61(8): 2126-2137, 2018 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-30073277

RESUMO

Purpose: Researchers have long noted speech recognition variability that is not explained by the pure-tone audiogram. Previous work (Souza, Wright, Blackburn, Tatman, & Gallun, 2015) demonstrated that a small number of listeners with sensorineural hearing loss utilized different types of acoustic cues to identify speechlike stimuli, specifically the extent to which the participant relied upon spectral (or temporal) information for identification. Consistent with recent calls for data rigor and reproducibility, the primary aims of this study were to replicate the pattern of cue use in a larger cohort and to verify stability of the cue profiles over time. Method: Cue-use profiles were measured for adults with sensorineural hearing loss using a syllable identification task consisting of synthetic speechlike stimuli in which spectral and temporal dimensions were manipulated along continua. For the first set, a static spectral shape varied from alveolar to palatal, and a temporal envelope rise time varied from affricate to fricative. For the second set, formant transitions varied from labial to alveolar and a temporal envelope rise time varied from approximant to stop. A discriminant feature analysis was used to determine to what degree spectral and temporal information contributed to stimulus identification. A subset of participants completed a 2nd visit using the same stimuli and procedures. Results: When spectral information was static, most participants were more influenced by spectral than by temporal information. When spectral information was dynamic, participants demonstrated a balanced distribution of cue-use patterns, with nearly equal numbers of individuals influenced by spectral or temporal cues. Individual cue profile was repeatable over a period of several months. Conclusion: In combination with previously published data, these results indicate that listeners with sensorineural hearing loss are influenced by different cues to identify speechlike sounds and that those patterns are stable over time.


Assuntos
Estimulação Acústica/métodos , Audiometria de Tons Puros/métodos , Sinais (Psicologia) , Perda Auditiva Neurossensorial/psicologia , Fonética , Estimulação Acústica/psicologia , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Percepção da Fala
18.
Am J Audiol ; 27(3): 272-282, 2018 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-29946686

RESUMO

PURPOSE: The purpose of this study was to examine contralateral inhibition of transient evoked otoacoustic emissions (TEOAEs) in young adults with normal hearing as a function of ear and sex. METHOD: Young female (n = 50) and male (n = 50) adults with normal hearing participated. TEOAEs were measured bilaterally with 80 dB peSPL nonlinear clicks and 60 dB peSPL linear clicks with and without a contralateral broadband noise elicitor at 65 dB SPL. Absolute TEOAE inhibition and normalized TEOAE inhibition (i.e., percentage of inhibition) were examined. RESULTS: With both 80 and 60 dB peSPL evoking stimuli, there were significant main effects of ear and sex (p < .05). TEOAE levels were larger in women and in the right ear. There were no statistically significant main effects of ear and sex on absolute TEOAE inhibition (p > .05). Significant main effects of ear and sex were, however, found with normalized TEOAE inhibition (p < .05; greater in men and in the left ear). Statistically significant negative correlations and significant linear predictive relations were found between TEOAE levels and normalized TEOAE inhibitions in both ears (p < .001). There is no evidence of the same with absolute inhibition of TEOAEs (p > .05). CONCLUSIONS: If one considers that efferent inhibition of TEOAEs is an absolute quantity, the significant effect of ear and sex on normalized inhibition and the negative association and linear predictive relationship between TEOAE level and inhibition can be viewed as spurious effects. As such, contralateral inhibition of TEOAEs does not suggest sex or ear laterality effects.


Assuntos
Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Lateralidade Funcional/fisiologia , Inibição Neural , Emissões Otoacústicas Espontâneas/fisiologia , Adolescente , Adulto , Análise de Variância , Audiometria de Tons Puros/métodos , Vias Auditivas/fisiologia , Estudos de Coortes , Feminino , Voluntários Saudáveis , Humanos , Modelos Lineares , Masculino , Valor Preditivo dos Testes , Fatores Sexuais , Adulto Jovem
19.
Otolaryngol Pol ; 72(6): 31-36, 2018 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-30647200

RESUMO

INTRODUCTION: Distorted processing of auditory information has a negative impact on the child's cognitive development. There are only a few studies conducted by Polish researchers determining normative values of psychoacoustic tests in auditory processing disorders. They are inconsistent due to different methodologies and research protocols. OBJECTIVE: The aim of this work is to determine the reference values of selected psychoacoustic tests for the population of Polish children between 7 and 12 years of age. MATERIAL AND METHOD: The study group consisted of 213 healthy children from 7 to 12 years of age. The condition for including the child in the study was an intellectual norm, proper sound sensitivity, proper development of children's voice and speech. All children underwent two auditory temporal processing tests. The diagnostic procedure used a standardized Frequency Pattern Test (FPT) and Duration Pattern Test (DPT). The tests were carried out in accordance with the authors' recommendations, using the original versions available on the CD for 60 dB SL intensity, simultaneously for the right and left ear. RESULTS: The reference values for FPT and DPT tests were determined at various age ranges in children aged 7-12. It has been shown that auditory functions change with the child's age and development. Reference values including age, language, cultural and educational differences were prepared. CONCLUSIONS: Development of reference values for individual tests for the Polish children population is a key element in reliable diagnosis of auditory processing.


Assuntos
Testes de Impedância Acústica/métodos , Audiometria de Tons Puros/métodos , Percepção Auditiva/fisiologia , Limiar Auditivo/fisiologia , Estimulação Acústica/métodos , Transtornos da Percepção Auditiva/diagnóstico , Criança , Feminino , Humanos , Masculino , Polônia , Valores de Referência
20.
Ear Nose Throat J ; 96(10-11): E47-E52, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29121385

RESUMO

We performed a prospective interventional study to evaluate correlations between hearing thresholds determined by pure-tone audiometry (PTA) and auditory steady-state response (ASSR) testing in two types of patients with hearing loss and a control group of persons with normal hearing. The study was conducted on 240 ears-80 ears with conductive hearing loss, 80 ears with sensorineural hearing loss, and 80 normal-hearing ears. We found that mean threshold differences between PTA results and ASSR testing at different frequencies did not exceed 15 dB in any group. Using Pearson correlation coefficient calculations, we determined that the two responses correlated better in patients with sensorineural hearing loss than in those with conductive hearing loss. We conclude that measuring ASSRs can be an excellent complement to other diagnostic methods in determining hearing thresholds.


Assuntos
Audiometria de Resposta Evocada/estatística & dados numéricos , Audiometria de Tons Puros/estatística & dados numéricos , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Neurossensorial/fisiopatologia , Estimulação Acústica , Adulto , Audiometria de Resposta Evocada/métodos , Audiometria de Tons Puros/métodos , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos/fisiologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA