Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.125
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Orthop Traumatol ; 25(1): 12, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430413

RESUMO

BACKGROUND: Alumina particles from the grit blasting of Ti-alloy stems are suspected to contribute to aseptic loosening. An alumina-reduced stem surface was hypothesized to improve osseointegration and show comparable short-term outcomes to those of a standard stem. METHODS: In this prospective, double-blind, randomized trial, 26 standard (STD) and 27 experimental new technology (NT) stems were implanted. The latter were additionally treated by acid etching and ice blasting to remove alumina particles from the grit-blasting process. Follow-up occurred at 12 and 24 months. Bone mineral density (BMD) around the stem was measured by a dual-energy x-ray absorptiometry device (DEXA). Radiographs were reviewed for alterations. Clinical scoring comprised the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Harris Hip Score (HHS). Survival rates were calculated up to 50 months. RESULTS: Lower mean BMD and more severe cortical hypertrophies were found in the NT group. At 12 months, radiolucent lines were observed mostly in the metaphyseal zone for both groups, with a progression tendency in the NT group at 24 months. At 12 months, pain scores and the WOMAC total and physical activity scores were significantly lower in the NT group, without any differences thereafter. The number of NT stem revisions amounted to 6 (24%) and 11 (41%) at 24 and 50 months, respectively. CONCLUSION: In the NT group, unexpected catastrophic failure rates of 41% caused by early aseptic loosening were noted within 50 months. Compared with the STD stems, NT stems lead to poor clinical and radiographic results. LEVEL OF EVIDENCE: II. TRIAL REGISTRATION: NCT05053048.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Absorciometria de Fóton , Óxido de Alumínio , Artroplastia de Quadril/métodos , Seguimentos , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Método Duplo-Cego
2.
IEEE Trans Haptics ; 16(3): 379-390, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37436850

RESUMO

When using EMG biofeedback to control the grasping force of a myoelectric prosthesis, subjects need to activate their muscles and maintain the myoelectric signal within an appropriate interval. However, their performance decreases for higher forces, because the myoelectric signal is more variable for stronger contractions. Therefore, the present study proposes to implement EMG biofeedback using nonlinear mapping, in which EMG intervals of increasing size are mapped to equal-sized intervals of the prosthesis velocity. To validate this approach, 20 non-disabled subjects performed force-matching tasks using Michelangelo prosthesis with and without EMG biofeedback with linear and nonlinear mapping. Additionally, four transradial amputees performed a functional task in the same feedback and mapping conditions. The success rate in producing desired force was significantly higher with feedback (65.4±15.9%) compared to no feedback (46.2±14.9%) as well as when using nonlinear (62.4±16.8%) versus linear mapping (49.2±17.2%). Overall, in non-disabled subjects, the highest success rate was obtained when EMG biofeedback was combined with nonlinear mapping (72%), and the opposite for linear mapping with no feedback (39.6%). The same trend was registered also in four amputee subjects. Therefore, EMG biofeedback improved prosthesis force control, especially when combined with nonlinear mapping, which showed to be an effective approach to counteract increasing variability of myoelectric signal for stronger contractions.


Assuntos
Amputados , Membros Artificiais , Percepção do Tato , Humanos , Eletromiografia , Biorretroalimentação Psicológica , Desenho de Prótese
3.
Heart Vessels ; 38(10): 1288-1297, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37247091

RESUMO

Clinical trials have demonstrated the efficacy of a balloon-expandable covered stent (CS) for aortoiliac occlusive disease (AIOD). However, the real-world clinical outcomes and the underlying factors remain unclear. We assessed the clinical outcomes and factors associated with primary patency after implantation of a balloon-expandable CS for patients with complex AIOD. This prospective multicenter observational study enrolled 149 consecutive patients undergoing VIABAHN® VBX-CS (W.L. Gore & Associates, Flagstaff, AZ) implantation for complex AIOD (age, 74 ± 9 years; male, 74%; diabetes mellitus, 46%; renal failure on dialysis, 23%; chronic limb-threatening ischemia, 26%). The primary study endpoint was 1-year primary patency, and the secondary endpoints were procedural complications, freedom from occlusion, clinical-driven target lesion revascularization (CD-TLR), and surgical revision at 1 year. Risk factors for restenosis were explored using random survival forest analysis. The median follow-up period was 13.1 months (interquartile range 9.7-14.0 months). Procedural complications were observed in 6.7% of the patients. The 1-year primary patency was 94.8% (95% confidence interval 91.0-98.6%), while the 1-year freedom rate from occlusion, CD-TLR, and surgical revision rates were 96.5% (93.5-99.5%), 94.7% (90.9-98.6%), and 97.8% (95.4-100%), respectively. The presence of chronic total occlusion, aortic bifurcation lesion, the number of disease regions, and TASC-II classification was significantly associated with the restenosis risk. In contrast, the calcification severity, IVUS use, IVUS parameters were not associated with restenosis risk. We observed excellent 1-year real-world outcomes after implantation of a balloon-expandable CS for complex AIOD; only a few perioperative complications occurred.


Assuntos
Aterosclerose , Implante de Prótese Vascular , Procedimentos Endovasculares , Persea , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular , Stents , Implante de Prótese Vascular/efeitos adversos , Aterosclerose/etiologia , Artéria Femoral , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos
4.
Curr Oncol ; 30(4): 4153-4165, 2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-37185429

RESUMO

(1) Background: The adjustable trans-obturator male system (ATOMS) is a surgical device developed to treat post-prostatectomy incontinence (PPI) after prostate cancer treatment. We review the current literature on this anti-incontinence device with the intention of assessing the effectiveness, safety and duration of the silicone-covered scrotal port (SSP) ATOMS, the only generation of the device that is currently available. (2) Material and Methods: Non-systematic literature review is performed. Forty-eight full-text articles are assessed for eligibility. Case reports, expert opinions or commentaries without specific data reported (n = 6), studies with patients who underwent intervention before 2014 (IP or SP ATOMS; n = 10), and studies with incontinence after transurethral resection of the prostate (TUR-P; n = 2) are excluded for analysis. Thirty studies with SSP ATOMS are included in a qualitative synthesis that incorporates systematic reviews (n = 3), articles partially overlapping with other previously published studies (e.g., follow-up or series updates; n = 9), and studies focusing on specific populations (n = 8). Only articles revealing outcomes of SSP ATOMS were included in the quantitative synthesis of results (n = 10). (3) Results: the pooled data of 1515 patients from the 10 studies with SSP ATOMS confirmed very satisfactory results with this device after adjustment: dry rate: 63-82%, improved rate: 85-100%, complication rate: 7-33%, device infection rate: 2.7-6.2% and explant rate: 0-19%. The durability of the device is reassuring, with 89% of devices in place 5 years after implantation. (4) Conclusion: Despite the absence of randomized controlled studies, the literature findings confirm results of SSP ATOMS appear equivalent to those of artificial urinary sphincters (AUSs) in terms of continence, satisfaction and complications, but with a lower rate of revision in the long-term. A prospective study identified that patients with daily pad test results <900 mL and a Male Stress Incontinence Grading Scale (MSIGS) of not 4 (i.e., early and persistent stream or urine loss) are the best candidates. Future studies centered on the elder population at higher risk of impaired cognitive ability and in patients including radiation as prostate cancer treatment are needed.


Assuntos
Neoplasias da Próstata , Slings Suburetrais , Ressecção Transuretral da Próstata , Humanos , Masculino , Idoso , Estudos Prospectivos , Resultado do Tratamento , Desenho de Prótese , Neoplasias da Próstata/cirurgia
5.
J Mech Behav Biomed Mater ; 142: 105860, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37127011

RESUMO

The fretting corrosion at the head-neck interface of artificial hip joints is an important reason for the failure of prostheses. The Ti6Al4V alloy-zirconia-toughened alumina (ZTA) ceramic combination has been widely used to make the head and neck of artificial hip joints. In this study, its fretting corrosion behavior in simulated body fluid was studied by electrochemical monitoring, surface morphology characterization, and chemical composition analysis. A running condition fretting map (RCFM) of load and displacement was established, including three regimes, namely partial slip regime (PSR), mixed fretting regime (MFR), and gross slip regime (GSR). The friction dissipation energy increased gradually from the PSR to MFR and GSR. In the PSR, the damage mechanisms were slight abrasive wear and tribocorrosion at the edge of contact area, as well as extremely slight adhesive wear at the center. In the MFR, the damage mechanisms were mainly adhesive wear, abrasive wear, and corrosive wear. In the GSR, the damage mechanism was serious abrasive wear, fatigue wear, and corrosive wear combined with slight adhesive wear. Finally, an ion-concentration map was created, displaying the material-loss transition of different displacements and loads. The material loss increased with the increased displacement, and increased first and then decreased with the increased load.


Assuntos
Artroplastia de Quadril , Líquidos Corporais , Cáusticos , Prótese de Quadril , Humanos , Corrosão , Óxido de Alumínio , Ligas , Falha de Prótese , Propriedades de Superfície , Desenho de Prótese
6.
J Arthroplasty ; 38(7 Suppl 2): S346-S350, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37105332

RESUMO

BACKGROUND: Highly cross-linked polyethylene (HXLPE) is a widely used bearing surface in total hip arthroplasty (THA); long-term results in young patients are limited. We previously demonstrated excellent results in HXPLE on cobalt-chrome femoral heads at 15-year mean follow-up. The purpose of the present study was to investigate polyethylene wear rates, implant survivorships, wear-related revisions, and patient-reported outcomes (PROs) in a young patient cohort who had alumina ceramic on HXPLE coupling at an average 16-year follow-up. METHODS: This was a retrospective study of 128 hips that underwent THA with HXLPE on alumina ceramic bearings between March 1, 2004, and April 15, 2007. The patient's mean age was 38 years (range, 13 to 50). All THAs utilized HXPLE liners with alumina ceramic heads. The University of California, Los Angeles activity score and modified Harris hip scores were collected preoperatively and at each follow-up. Martell hip analysis suite was used for wear calculations. RESULTS: At average 16 years (range, 13 to 18), aseptic revision survivorship was 93.3% and osteolysis/wear survivorship was 99.2%. The mean linear wear rate was 0.0191 mm/year and mean volumetric wear rate was 19.43 mm3/y, both of which were clinically undetectable. We observed excellent PROs with a significant increase in mean modified Harris hip scores (43.6 to 87.4, P < .0001) and the University of California, Los Angeles activity scores (4.0 to 6.0, P < .0001). There were no statistically significant differences in PROs or wear rates between ceramic and cobalt-chrome groups. CONCLUSION: At a mean 16-year follow-up, young patients who had HXLPE on ceramic coupling had excellent wear properties, PROs, and acceptable survivorships.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Adulto , Polietileno , Estudos Retrospectivos , Cabeça do Fêmur/cirurgia , Óxido de Alumínio , Falha de Prótese , Desenho de Prótese , Cerâmica , Ligas de Cromo , Cobalto , Seguimentos
8.
J Arthroplasty ; 38(5): 855-861.e1, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36535447

RESUMO

BACKGROUND: Cementless total hip arthroplasty (THA) femoral stems are the most commonly selected prostheses in the United States. Optimal stem geometry remains controversial with excellent survivorship reported for many designs. We compared cause-specific stem revision of single-wedge versus double-wedge designs from a multicenter US cohort. METHODS: Data from an integrated healthcare network's total joint replacement registry were used to conduct a cohort study. Primary elective cementless THAs were identified (2001 to 2018). Implant exposure groups were classified by design geometry using the system proposed by Khanuja et al. Type 1 single-wedge (n = 11,082) and type 2 double-wedge (n = 32,380) designs were compared, and other design types were excluded; the final study cohort comprised 43,462 THAs. Cause-specific multivariable Cox regressions were used to evaluate risk for revision due to infection or aseptic reasons, including loosening, instability, periprosthetic fracture, or other reasons. RESULTS: After adjustment for covariates, a higher aseptic revision risk was observed for type 1 when compared to type 2 designs (hazard ratio = 1.91, 95% confidence interval = 1.33-2.75). When looking at specific revision reasons, revision for aseptic loosening (hazard ratio = 3.46, 95% confidence interval = 2.24-5.34) was higher for type 1 versus type 2 designs. No differences were found for septic revision, instability, periprosthetic fracture, or revisions for other reasons. CONCLUSIONS: Type 1 single-wedge designs were found to have a higher risk of revision due to aseptic loosening relative to type 2 double-wedge designs. Femoral stem geometry should be considered when selecting a cementless femoral implant. LEVEL OF EVIDENCE: Level III.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Estudos de Coortes , Falha de Prótese , Fatores de Risco , Reoperação , Desenho de Prótese , Resultado do Tratamento
9.
Arch Orthop Trauma Surg ; 143(3): 1679-1688, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35397656

RESUMO

BACKGROUND: Aseptic loosening remains a challenging problem after total hip arthroplasty. Accurate cup placement and supplementation of antioxidants in acetabular liners might reduce material failure rates. The aim of this study is to assess the effect of the cup position on the wear behaviour of UHMWPE-XE and UHMWPE-X liners in vivo using virtual radiographs. METHODS: We conducted a prospective, randomized, controlled, multicenter trial. Clinical data of 372 probands were analyzed. Anteroposterior pelvic X-rays of 324 patients immediately postoperatively and after 1 and 5 years were evaluated by the RayMatch® analysis software regarding cup position and wear behaviour. RESULTS: Mean cup anteversion was 20.3° (± 7.4) and inclination was 41.9° (± 7.0) postoperatively. 62.3% of all patients had an anteversion and inclination within the Lewinnek safe zone. Anterior and anterolateral approaches led to significantly higher cup anteversion compared to lateral approaches (27.3° ± 5.5; 20.9° ± 7.2; 17.5° ± 6.6; p < 0.001 and p = 0.001, respectively). Mean anteversion increased to 24.6° (± 8.0) after 1 year (p < 0.001). Only one revision occurred because of implant dislocation. Wear rates from UHMWPE-X and UHMWPE-XE did not differ significantly. Anteversion angles ≥ 25° correlated to increased polyethylene wear (23.7 µm/year ± 12.8 vs. 31.1 µm/year ± 22.8, p = 0.012) and this was amplified when inclination angles were ≥ 50° (23.6 µm/year ± 12.8 vs. 38.0 µm/year ± 22.7, p = 0.062). CONCLUSION: Anterior approaches lead to the highest inaccuracy of cup placement, but cup positioning outside the Lewinnek safe zone does not necessarily cause higher dislocation rates. Moreover, mean anteversion increased by approximately four degrees within the first year after operation, which is expected to be functional due to a regularization of pelvic tilt after intervention. Mid-term wear rates of UHMWPE-X and UHMWPE-XE liners are comparable, but steep cup positions lead to significantly increased polyethylene wear. In summary, a re-evaluation of target zones for intraoperative cup positioning might be considered. In the long-term reduced oxidative embrittlement could lead to superior wear behaviour of vitamin E-blended liners.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Polietileno , Estudos Prospectivos , Vitamina E , Seguimentos , Desenho de Prótese , Acetábulo/cirurgia , Luxações Articulares/cirurgia
10.
J Endovasc Ther ; 30(2): 312-315, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35184605

RESUMO

Purpose: Virtual reality (VR) has both a non-pharmacological analgesic and anxiolytic action that can be used as an alternative to general anesthesia for very high-risk patients. Case report: We present here the case of a patient treated for a complex endovascular thoracoabdominal aortic aneurysm exclusion using a 4-fenestrated aortic endograft using VR. The patient had no postoperative complications and was safely discharged from the hospital on postoperative day 6. Conclusion: This case demonstrates that the use of VR in addition to local anesthesia can be a safe alternative to general anesthesia.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Realidade Virtual , Humanos , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Anestesia Local , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Fatores de Tempo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia
11.
Arch Orthop Trauma Surg ; 143(2): 603-610, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34345935

RESUMO

BACKGROUND: Endo-exo prosthetics (EEP), which belongs to the transcutaneous osseointegrated prosthetic systems (TOPS), provides an alternative bone-anchored rehabilitation method for transfemoral amputees. It led to the question of whether transmitted forces from prosthetic feet are perceptible by osseoperception resulting in proprioceptive feedback of ground conditions. OBJECTIVES: The following hypotheses emerged for our trial with the null hypothesis: EEP fitting after transfemoral amputation does not influence osseoperception. Alternative hypothesis 1: EEP patients achieve better osseoperception results than transfemoral amputees fitted with socket prosthesis. Alternative hypothesis 2: EEP carriers achieve comparable results with regards to their osseoperception as non-amputees. METHODS: N = 25 patients with EEP (mean age = 50,6 ± 9,4, male/female = 15/10) N = 25 patients with socket prostheses (mean age = 52,6 ± 13,1, male/female = 19/6) and N = 25 healthy volunteers were included in the experimental case-control study. In three blinded test modules (V1, V2, V3), the participants had to identify different degrees of shore hardness (c) of different materials (rubber balls (shore = 5-25c), foam cushions (shore = 5-30c), foam mats (shore = 5-30c) with their prosthetic foot (or a personally defined foot in healthy volunteers) without footwear and had to rank them into the correct order according to their tactile sensation and the degree of hardness. A maximum of 10 points could be scored per run. RESULTS: This experimental observational study included N = 75 participants. The mean age for the entire cohort was 42.8 ± 16.6 years and the BMI was 26.0 ± 4.8. Our results show a significant level of differences in tactile osseoperception between all groups (p < 0.001). A correlation between the mean values of V1-3 and the PMQ2.0 as well as the mean values of K-Level and the prosthesis wearing time per day showed for PMQ (r = 0.387, p = 0.006) and K-level (r = 0.448, p = 0.001) which is a moderate effect according to Cohen. CONCLUSION: Our study results suggest that the EEP treatment can lead to an improvement in tactile sensory perception via the bone-anchored implant, which can lead to an increase in quality of life and improved gait safety.


Assuntos
Membros Artificiais , Qualidade de Vida , Humanos , Feminino , Masculino , Recém-Nascido , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Estudos de Casos e Controles , Resultado do Tratamento , Amputação Cirúrgica , Osseointegração
12.
Injury ; 53(12): 4114-4122, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36333155

RESUMO

AIM: Some amputees are unable to adequately ambulate using conventional socket prosthetics, osseointegrated prosthetics have been described as an alternative strategy in this patient group. This paper aims to assess the effect of osseointegrated prosthetics, commonly simply referred to as osseointegration, in transfemoral amputees on health-related quality of life and cost analysis. METHODS: Two centre analysis of patients receiving transcutaneous femoral osseointegration using The Osseointegration Group of Australia Osseointegration Prosthetic Limb (OGAP-OPL) implant. Retrospective health utility and cost analysis of prospectively collected patient reported health outcome data. Osseointegration cost was compared with the yearly cost of a poorly fitting conventional prosthetic determining cost/Quality Adjusted Life Year. RESULTS: Eighty amputees received osseointegration. Mean age was 39 years (range 20-57) and 66% were male (n = 53). The majority of subjects underwent unilateral (n = 62, 77.5%) rather than bilateral surgery (n = 18, 22.5%). Trauma was the most common indication (n = 59, 74%). Maximum follow up was 10.5-years. Mean preoperative EQ5D HUV in pooled data was 0.64 (SEM 0.025) increasing to 0.73 (0.036) at 5-years and 0.78 (0.051) at 6 years with continued improvement up to 10.5-years. In subgroup analysis those with a starting EQ5D HUV <0.60 reached a cost/QALY of <£30,000 at 5-years postoperatively and show statistically significant improvement in EQ5D HUV. The UK military experience was wholly positive with a mean starting EQ5D HUV of 0.48 (0.017) with significant (p < 0.05) improvement in EQ5D HUV at each time point and a resultant reducing cost/QALY at each time point being £28,616.89 at 5 years. CONCLUSION: There is both a quality of life and financial argument in favour of osseointegration in select patients with above transfemoral amputations. In those unable to mobilise satisfactorily with traditional prostheses and a pre-intervention score of <0.60, a consistent cost effectiveness and quality of life benefit can be seen. Such patients should be considered for osseointegration as these patients reap the maximum benefit and cost effectiveness of the device. This evidence lends strongly to the debate advocating the use of osseointegration through centrally funded resources, including the NHS.


Assuntos
Amputados , Membros Artificiais , Humanos , Masculino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Feminino , Osseointegração , Qualidade de Vida , Análise Custo-Benefício , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Amputação Cirúrgica
13.
J Neural Eng ; 19(4)2022 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-35944515

RESUMO

Objective.Lower-limb amputees suffer from a variety of health problems, including higher metabolic consumption and low mobility. These conditions are linked to the lack of a natural sensory feedback (SF) from their prosthetic device, which forces them to adopt compensatory walking strategies that increase fatigue. Recently, both invasive (i.e. requiring a surgery) and non-invasive approaches have been able to provide artificial sensations via neurostimulation, inducing multiple functional and cognitive benefits. Implants helped to improve patient mobility and significantly reduce their metabolic consumption. A wearable, non-invasive alterative that provides similar useful health benefits, would eliminate the surgery related risks and costs thereby increasing the accessibility and the spreading of such neurotechnologies.Approach.Here, we present a non-invasive SF system exploiting an optimally-calibrated (just noticeable difference-based) electro-cutaneous stimulation to encode intensity-modulated foot-ground and knee angle information personalized to the user's just noticeable perceptual threshold. This device was holistically evaluated in three transfemoral amputees by examination of metabolic consumption while walking outdoors, walking over different inclinations on a treadmill indoors, and balance maintenance in reaction to unexpected perturbation on a treadmill indoors. We then collected spatio-temporal parameters (i.e. gait dynamic and kinematics), and self-reported prosthesis confidence while the patients were walking with and without the SF.Main results.This non-invasive SF system, encoding different distinctly perceived levels of tactile and knee flexion information, successfully enabled subjects to decrease metabolic consumption while walking and increase prosthesis confidence. Remarkably, more physiological walking strategies and increased stability in response to external perturbations were observed while walking with the SF.Significance.The health benefits observed with the use of this non-invasive device, previously only observed exploiting invasive technologies, takes an important step towards the development of a practical, non-invasive alternative to restoring SF in leg amputees.


Assuntos
Amputados , Membros Artificiais , Fenômenos Biomecânicos , Retroalimentação , Marcha/fisiologia , Humanos , Desenho de Prótese , Caminhada/fisiologia
14.
BMC Musculoskelet Disord ; 23(1): 796, 2022 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-35987675

RESUMO

BACKGROUND: Total hip arthroplasty(THA)is widely used to treat end-stage hip disorders. Ceramic-on-ceramic total hip prostheses are widely used because of their durability. Alumina matrix composite (AMC), known as the fourth-generation ceramics, reduces implant fracture and wear rate compared to their predecessors. However, ceramic acetabular liner dissociation is a complication that necessitates revision of the AMC prostheses. To date, only few cases of AMC liner dissociation have been reported and all of which have been treated with revision surgery. Therefore, the prognosis of non-operated AMC liner dissociation remains unknown so far. CASE PRESENTATION: A 57-year-old man with avascular necrosis of the femoral head was treated with THA, wherein a Pinnacle® (DePuy, J&J, Warsaw, IN) acetabular cup and AMC liner were implanted. Intraoperative examination confirmed proper seating of the liner, whereas the initial postoperative radiograph revealed liner dissociation. The patient refused surgical revision due to the absence of symptoms and was discharged and followed-up. The patient made an uneventful recovery, and radiographic follow-up at 6-month post-operation showed that the liner was re-seated to its right position. No clinical or radiographic anomaly was found at the 15-month of postoperative follow-up. CONCLUSIONS: Here, we report an unprecedented case of AMC ceramic liner dissociation with spontaneous resolution. This case shows that ceramic liner dissociation could be asymptomatic, and careful postoperative examination of the patient is important. Spontaneous resolution is possible, but the underlying mechanism and the eligible patient to benefit from it must be investigated. Before clarifying these questions, revision surgery should be the first-line treatment.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Cerâmica , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação
15.
BMC Ophthalmol ; 22(1): 151, 2022 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-35366841

RESUMO

BACKGROUND: This prospective comparative study aimed to investigate the influence of diffractive trifocal intraocular lenses (IOLs) implantation on standard automated perimetry. METHODS: Patients with no diseases affecting the visual field had undergone cataract surgery following the implantation of trifocal or monofocal IOLs from July 2019 to August 2020 were recruited. The normality of the anterior and posterior segments and absence of glaucomatous optic nerve cupping were confirmed preoperatively by slit-lamp examination. Standard automated perimetry was performed using Humphrey Visual Field 10-2 testing, 2-3 months after cataract surgery in only one eye per patient. The mean deviation (MD) and foveal sensitivity were compared between IOLs in eyes with acceptable reliability indices and best-corrected visual acuity of 20/25 or better. RESULTS: Among the 83 eyes of the 83 patients included, 39 and 29 eyes eligible for perimetry analysis had trifocal and monofocal IOLs, respectively. The mean MD and foveal sensitivity in eyes with trifocal IOLs were significantly lower than those in eyes with monofocal IOLs (P < 0.021), with mean differences of 0.77 and 1.01 dB, respectively. CONCLUSION: The comparison in nonglaucomatous eyes demonstrated that the influence of trifocal IOLs on standard automated perimetry was greater than that of monofocal IOLs.


Assuntos
Lentes Intraoculares , Testes de Campo Visual , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Acuidade Visual
16.
Sci Rep ; 12(1): 5306, 2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35351910

RESUMO

The walking pattern and comfort of a person with lower limb amputation are determined by the prosthetic foot's diverse set of mechanical characteristics. However, most design methodologies are iterative and focus on individual parameters, preventing a holistic design of prosthetic feet for a user's body size and walking preferences. Here we refined and evaluated the lower leg trajectory error (LLTE) framework, a novel quantitative and predictive design methodology that optimizes the mechanical function of a user's prosthesis to encourage gait dynamics that match their body size and desired walking pattern. Five people with unilateral below-knee amputation walked over-ground at self-selected speeds using an LLTE-optimized foot made of Nylon 6/6, their daily-use foot, and a standardized commercial energy storage and return (ESR) foot. Using the LLTE feet, target able-bodied kinematics and kinetics were replicated to within 5.2% and 13.9%, respectively, 13.5% closer than with the commercial ESR foot. Additionally, energy return and center of mass propulsion work were 46% and 34% greater compared to the other two prostheses, which could lead to reduced walking effort. Similarly, peak limb loading and flexion moment on the intact leg were reduced by an average of 13.1%, lowering risk of long-term injuries. LLTE-feet were preferred over the commercial ESR foot across all users and preferred over the daily-use feet by two participants. These results suggest that the LLTE framework could be used to design customized, high performance ESR prostheses using low-cost Nylon 6/6 material. More studies with large sample size are warranted for further verification.


Assuntos
Perna (Membro) , Caminhada , , Humanos , Desenho de Prótese , Amplitude de Movimento Articular
17.
J Mech Behav Biomed Mater ; 127: 105072, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35033983

RESUMO

A novel polymer-on-metal hip joint prosthesis design that makes use of uni-directional articulations was developed and tested in this work. The new implant was tested using two polymer variants, virgin ultra-high molecular weight polyethylene (UHMWPE), and Vitamin E-infused highly crosslinked polyethylene (VEHXPE). The degrees of freedom of the ball-and-socket are reproduced by three cylindrical orthogonally-aligned articulations. This unconventional design leverages on the molecular orientation hardening mechanisms of the polyethylene and increased contact area to minimize wear. An experimental hip joint simulator was used to compare the gravimetric wear of the conventional ball-on-socket and the new implant. The new prosthesis including UHMWPE components produced a 78% reduction in wear, whereas the new prosthesis with VEHXPE components produced a 100% reduction in wear, as no measurable wear was detected. Machining marks on the acetabular cups of the new prosthesis were retained for both polyethylene variants, further demonstrating the low levels of wear exhibited by the new implants. Both polyethylene materials produced particles in the range of 0.1-1.0 µm, which are the most biologically active. Nonetheless, the extremely low wear rates are likely to induce minimal osteolysis effects. Furthermore, the novel design also offers an increase of more than 24% in the range of motion in flexion/extension when compared to a dual-mobility hip implant. A prototype of the prosthesis was implanted into a Thiel-embalmed human cadaver during a mock-surgery, which demonstrated high resistance to dislocation and the possibility of performing a figure of four position.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Articulação do Quadril/cirurgia , Humanos , Teste de Materiais , Polietileno , Polietilenos , Desenho de Prótese , Falha de Prótese , Vitamina E
18.
Eur J Orthop Surg Traumatol ; 32(6): 1127-1136, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34357474

RESUMO

INTRODUCTION: The optimum choice of bearing surfaces in total hip replacement (THR) in the younger and active patient remains controversial. The aim of this study was to report the 10 year clinical outcomes, and a median of 15 year implant survival and incidence of complications in a series of Alumina ceramic-on-ceramic THRs utilising an uncemented shell and cemented stem. METHODS: From January 2004 to December 2007, 175 consecutive patients (195 hips) underwent primary THR. The acetabular components was Trident Peripheral Self Locking (Stryker Orthopaedics) with a third-generation ceramic head and liner (Alumina ceramic, Stryker Orthopaedics). The stem utilised was an Exeter V-40 (Stryker Orthopaedics). Data were collated on demographics, surgical factors, clinical outcomes, radiographic outcomes and revision. RESULTS: 23 patients (27 THRs) died during the follow-up period at a median of 7.8 (3.8 to 9.0) years post-operatively due to causes unrelated to the THR. Median age at time of surgery was 55 (interquartile range 48-60) years. Median follow-up for surviving patients was 15.2 years. Survivorship for all-cause revision was 97.2%. Increasing patient age at time of surgery was associated with a higher OHS at 10 years (p = 0.022). 32 mm head diameter had an improved OHS at 3 months (p = 0.014) and 10 years (p = 0.030). Posterior surgical approach had a statistically significant better OHS at 3 months (p = 0.015) and 1 year (p < 0.001), but the effect was not significant at 10 years (p = 0.440). CONCLUSION: The findings of this study support excellent long-term outcomes and survivorship of Alumina ceramic-on-ceramic bearing in a hybrid THR in a younger population. Surgical factors leading to a more favourable outcome were the use of a 32 mm femoral head and a posterior approach. Increasing age at surgery demonstrated the most sustained improvement in 10 year clinical outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Cerâmica , Seguimentos , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
19.
Ann Vasc Surg ; 79: 273-278, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34644640

RESUMO

OBJECTIVES: Low profile endovascular aneurysm repair (EVAR) devices such as the Cordis INCRAFT AAA Stent Graft System may expand the category of patients suitable for endovascular repair. We report our experience with the INCRAFT system in treating ruptured abdominal aortic aneurysms (rAAA). METHODS: We included all patients presenting with rAAA from 2015 to 2019 in our hospital who were treated by percutaneous EVAR with the INCRAFT system. The primary outcome was technical success, referring to adequate stent graft placement. Secondary outcomes included completion of the procedure under local anesthesia and mortality at 30-days, one year and long-term follow-up. RESULTS: Fifteen male patients (mean age: 74 years, SD 6.7) were treated for rAAA with a median aneurysm diameter of 8.25 cm (SD 1.66). The device was successfully delivered and deployed in all subjects. Per-procedurally one type I endoleak required additional stent placement and one patient developed an acute thrombosis of the device main body and iliac limbs requiring thrombectomy. 80.0% of patients were successfully treated under local anesthesia only. The 30 day and one year mortality were 26.6% and 33.3% respectively. Long-term survival was 60.0% at a median follow-up period of 57 months, with two patients requiring late reintervention for an endoleak. CONCLUSIONS: The INCRAFT system can be used to percutaneously treat rAAA with a high technical success rate and mortality similar to reported in the literature for other devices. The large majority of procedures can be completed with only local anesthesia.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Anestesia Local , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
20.
Arch Orthop Trauma Surg ; 142(7): 1689-1695, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34269893

RESUMO

INTRODUCTION: The effectiveness of modern ceramic bearings has been well established in reducing the osteolysis associated with wear of the bearing surfaces in total hip arthroplasty (THA). However, there are limited mid- to long-term follow-up data for complications associated with ceramic bearings. MATERIALS AND METHODS: This case series analyzed 124 consecutive primary uncemented THAs in 108 patients with a mean age of 61 years using alumina ceramic-on-alumina ceramic bearing couples. Seventy THAs (56%) were evaluated at a minimum 14 years of follow-up; the mean follow-up period was 16 ± 1 years (14-20 years). Kaplan-Meier survivorship was determined with revision surgery for any reason as the end point. Complications were recorded focusing on osteolysis, ceramic fracture, and abnormal sounds until the final follow-up. Clinical data were scored according to the Merle d'Aubigne and Postel hip score at 14 years after THA. RESULTS: The survivorship was 93.5% (95% CI 86.7-97.0%) at 14-years postoperatively. Five patients (4.0%) underwent revision surgery due to instability or infection before 1-year postoperatively. Two patients (1.6%) underwent revision surgery due to ceramic liner fracture at 9- and 12-years postoperatively, respectively. There was no radiographic evidence of osteolysis. A total of 27 complications occurred: dislocations (n = 7/124), squeaking sounds (n = 3/124), clicking sounds (n = 6/124), ceramic liner fractures (n = 2/124), periprosthetic fractures (n = 4/124), deep infections (n = 2/124), transient sciatic nerve palsy (n = 2/124), and femoral stem breakage (n = 1/124). The Merle d'Aubigne and Postel hip score was 16.8 ± 1.4 points. CONCLUSIONS: The survivorship analysis demonstrates the uncemented THA using alumina ceramic bearings may provide favorable clinical outcome and can offer minimal wear at a minimum 14-year follow-up. Revision surgery was mostly required due to instability and infection in the short-term, and implant breakage in the mid- to long-term.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Cerâmica , Seguimentos , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Pessoa de Meia-Idade , Osteólise/etiologia , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA