1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 44(1): 80-84, 2020 Jan 08.
Artigo em Chinês | MEDLINE | ID: mdl-32343074

RESUMO

The supply chain management of medical consumables in hospitals is an important guarantee for the improvement of clinical diagnosis and treatment. It requires continuous re-engineering and optimization on procurement and supplier management, costs and efficiency of daily operation. Based on the practical case of Shanghai Yueyang Integrated Traditional Chinese Medicine and Western Medicine Hospital, the study discusses the practical path and key points as well as improvement results in hospital medical consumables supply chain re-engineering via SPD model. Also, the research can provide references on medical consumables supply chain management to large and medium-size hospitals.


Assuntos
Equipamentos Descartáveis/provisão & distribuição , Hospitais , China , Custos e Análise de Custo
2.
Artigo em Chinês | WPRIM | ID: wpr-942703

RESUMO

The supply chain management of medical consumables in hospitals is an important guarantee for the improvement of clinical diagnosis and treatment. It requires continuous re-engineering and optimization on procurement and supplier management, costs and efficiency of daily operation. Based on the practical case of Shanghai Yueyang Integrated Traditional Chinese Medicine and Western Medicine Hospital, the study discusses the practical path and key points as well as improvement results in hospital medical consumables supply chain re-engineering via SPD model. Also, the research can provide references on medical consumables supply chain management to large and medium-size hospitals.


Assuntos
China , Custos e Análise de Custo , Equipamentos Descartáveis/provisão & distribuição , Hospitais
3.
Burns ; 45(7): 1621-1624, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31371231

RESUMO

Recent global concern regarding the impact of plastic waste on the environment has resulted in efforts to utilise reusable drink containers. Research is lacking regarding temperature dissociation of drinks in reusable thermoplastic cups. This study aimed to compare the cooling time of two common hot drinks sold at a UK retailer, in the three vessels they are sold; ceramic, disposable paper (with and without lid) and reusable thermoplastic cups (with and without lid). All temperatures were collated from 250 ml volumes of black Americano coffee or café latte in the three different containers. The cooling time was measured every sixty seconds using a standardised digital thermocouple thermometer until a threshold liquid temperature of 43 °C was reached. All experiments were performed in triplicate and temperatures converted to a dimensionless logarithmic scale prior to statistical analysis. Cooling time was significantly slower for lidded cups irrespective of material. Unlidded thermoplastic cups significantly slowed cooling times for both black Americano coffee and café latte compared to ceramic and unlidded disposable paper cups. The growing trend in reusable cups does not in itself pose an increased risk of scald injury. However, we consider that the potentially increased ambulatory behaviour associated with using a lidded rather than unlidded cup may increase scald risk. We propose that further consumer guidance should be disseminated regarding the use of any lidded takeaway container to prevent scalds in both adults and children.


Assuntos
Queimaduras , Cerâmica , Café , Utensílios de Alimentação e Culinária , Temperatura Alta , Plásticos , Bebidas , Equipamentos Descartáveis , Humanos , Termômetros
5.
Hand (N Y) ; 14(2): 271-276, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29183168

RESUMO

BACKGROUND: The US health care sector has substantial financial and environmental footprints. As literature continues to study the differences between wide-awake hand surgery (WAHS) and the more traditional hand surgery with sedation & local anesthesia, we sought to explore the opportunities to enhance the sustainability of WAHS through analysis of the respective costs and waste generation of the 2 techniques. METHODS: We created a "minimal" custom pack of disposable surgical supplies expressly for small hand surgery procedures and then measured the waste from 178 small hand surgeries performed using either the "minimal pack" or the "standard pack," depending on physician pack choice. Patients were also asked to complete a postoperative survey on their experience. Data were analyzed using 1- and 2-way ANOVAs, 2-sample t tests, and Fisher exact tests. RESULTS: As expected, WAHS with the minimal pack produced 0.3 kg (13%) less waste and cost $125 (55%) less in supplies per case than sedation & local with the standard pack. Pack size was found to be the driving factor in waste generation. Patients who underwent WAHS reported slightly greater pain and anxiety levels during their surgery, but also reported greater satisfaction with their anesthetic choice, which could be tied to the enthusiasm of the physician performing WAHS. CONCLUSIONS: Surgical waste and spending can be reduced by minimizing the materials brought into the operating room in disposable packs. WAHS, as a nascent technique, may provide an opportunity to drive sustainability by paring back what is considered necessary in these packs. Moreover, despite some initial anxiety, many patients report greater satisfaction with WAHS. All told, our study suggests a potentially broader role for WAHS, with its concomitant emphases on patient satisfaction and the efficient use of time and resources.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Anestesia Local , Equipamentos Descartáveis/economia , Eficiência Organizacional , Equipamentos e Provisões Hospitalares/economia , Mãos/cirurgia , Ansiedade/etiologia , Humanos , Hipnóticos e Sedativos/uso terapêutico , Eliminação de Resíduos de Serviços de Saúde , Salas Cirúrgicas , Medição da Dor , Satisfação do Paciente , Pennsylvania
7.
J Endourol ; 31(3): 314-319, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27981854

RESUMO

INTRODUCTION & OBJECTIVES: Transurethral enucleation of the prostate for the management of benign prostatic obstruction (BPO) involves two steps: the enucleation and morcellation procedure. The aim of our study was to assess the efficacy of a morcellator device using disposable and reusable blades with different settings of morcellation speed. METHODS: A prospective randomized study was initiated for patients with symptomatic BPO undergoing Thulium laser enucleation of the prostate. Mechanical tissue morcellation was performed using the Piranha™ morcellator (R. Wolf, Knittlingen, Germany) with disposable or reusable blades at 850 (n = 24) or 1500 revolutions per minute (rpm) (n = 24). Patient characteristics, intraoperative complications, and the morcellation rate (g/min) were recorded. Data are expressed as median and interquartile range (IQR). RESULTS: Forty-eight patients were randomized using disposable (n = 24) or reusable blades (n = 24). For reusable blades, the morcellation rate did not increase when changing the morcellation speed from 850 to 1500 rpm (5 vs 4.53 g/min, p = 0.843). The morcellation rate increased significantly when changing the morcellation speed from 850 to 1500 rpm using single-use blades (4.77 vs 10 g/min, p ≤ 0.014). The morcellation rate was not different at 850 rpm between reusable and single-use blades (5 vs 4.77 g/min, p = 0.671). Conversely, the morcellation rate was significantly different at 1500 rpm between reusable and single-use blades (4.53 vs 10 g/min, p ≤ 0.017). The total morcellation rate (at 850 and 1500 rpm) was significantly increased using single-use blades compared to reusable blades (7.67 vs 4.8 g/min, p ≤ 0.026). Interestingly, enucleated weight (g) and the morcellation rate (g/min) correlated inversely using single-use blades at 1500 rpm (r = -0.742, p ≤ 0.004). Only one superficial bladder injury occurred at 1500 rpm, which needed no further interventions. CONCLUSIONS: The Piranha morcellator facilitates efficient tissue removal with single-use and reusable blades. Disposable morcellator blades increase tissue removal significantly at 1500 rpm.


Assuntos
Equipamentos Descartáveis , Reutilização de Equipamento , Terapia a Laser/métodos , Morcelação/instrumentação , Hiperplasia Prostática/cirurgia , Ressecção Transuretral da Próstata/instrumentação , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Int Angiol ; 35(4): 406-10, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26934561

RESUMO

BACKGROUND: A previous study using electrical stimulation of the common peroneal nerve (geko™) to activate the venous muscle pump measured blood flow in both the femoral and popliteal veins. Increased blood flow by as much as 60% was demonstrated in the femoral vein. Such an increase is assumed to be as a result of an increase in venous flow from the deep calf veins; however this has yet to be confirmed. The aim of this study was to conduct direct measurements in these deep calf veins to confirm this assumption in healthy individuals. METHODS: This was a single centre open-label intra-subject healthy volunteer comparison of blood flow in the peroneal, posterior tibial and gastrocnemial veins with and without the geko™ device. The device was applied to 18 volunteers. Peak venous velocity (PV) and ejected volume per individual stimulus (VS) and volume flow (VF) was determined using ultrasound. RESULTS: Peak velocity (PV) increased 216% in the peroneal vein, by 112% in the posterior tibial vein and by 137% in the gastrocnemial vein (P<0.001). Ejected volume per stimulus increased by 113% in the peroneal vein, by 38% in the posterior tibial vein and by 50% in the gastrocnemial vein (P<0.003). Associated volume flows during the muscle contraction were increased by 36%, 25% and 17%, respectively (P=0.05) CONCLUSIONS: This is the first time that neuromuscular electro-stimulation has been shown to be an effective method of increasing flow in the axial deep veins of the calf. Significant increases in velocity and volume flow in response to the electrical stimulus were seen in all three veins studied. Enhancements of both blood velocity and volume flow are key factors in the prevention of venous stasis and ultimately deep vein thrombosis (DVT). Further studies are justified to determine the efficacy of the device in the prevention of DVT.


Assuntos
Equipamentos Descartáveis , Terapia por Estimulação Elétrica/instrumentação , Contração Isométrica , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/inervação , Nervo Fibular/fisiologia , Veias/fisiologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Desenho de Equipamento , Feminino , Voluntários Saudáveis , Humanos , Londres , Extremidade Inferior , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Ultrassonografia , Veias/diagnóstico por imagem , Adulto Jovem
9.
Biosens Bioelectron ; 64: 625-32, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25441411

RESUMO

The use of live bacterial reporters as sensing entities in whole-cell biosensors allows the investigation of the biological effects of a tested sample, as well as the bioavailability of its components. Here we present a proof of concept for a new design for online continuous water monitoring flow-cell biosensor, incorporating recombinant reporter bacteria, engineered to generate an optical signal (fluorescent or bioluminescent) in the presence of the target compound(s). At the heart of the flow-cell is a disposable chip made of porous aluminum oxide (PAO), which retains the sensor microorganisms on its rigid planar surface, while its high porosity allows an undisturbed access both to the sample and to essential nutrients. The ability of the bacterial reporters to detect model toxic chemicals was first demonstrated using a "naked" PAO chip placed on solid agar, and later in a chip encased in a specially designed flow-through configuration which enables continuous on-line monitoring. The applicability of the PAO chip to simultaneous online detection of diverse groups of chemicals was demonstrated by the incorporation of a 6-member sensor array into the flow-through chip. The selective response of the array was also confirmed in spiked municipal wastewater effluents. Sensing activity was retained by the bacteria after 12-weeks storage of freeze-dried biochips, demonstrating the biochip potential as a simple minimal maintenance "plug-in" cartridge. This low-cost and easy to handle PAO-based flow-cell biosensor may serve as a basis for a future platform for water quality monitoring.


Assuntos
Óxido de Alumínio/química , Fenômenos Fisiológicos Bacterianos/efeitos dos fármacos , Bioensaio/instrumentação , Monitoramento Ambiental/instrumentação , Análise de Injeção de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Poluentes Químicos da Água/análise , Reatores Biológicos/microbiologia , Técnicas Biossensoriais/instrumentação , Equipamentos Descartáveis , Desenho de Equipamento , Análise de Falha de Equipamento , Medições Luminescentes/instrumentação , Miniaturização , Porosidade , Transdutores , Poluentes Químicos da Água/farmacologia , Qualidade da Água
10.
Can J Physiol Pharmacol ; 93(4): 223-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25494822

RESUMO

OBJECTIVE: To evaluate the toxicity of extracts from disposable chopsticks, toothpicks, and paper cups on L-929 cells. METHODS: We followed national standards to prepare the extracts from disposable chopsticks, toothpicks, and paper cups used for the cell culture media, and the morphology of L-929 cells was observed with an optical microscope. The loss rate for adherent cells was evaluated with the trypan blue exclusion method, and cell proliferation was determined using the WST-1 assay. RESULTS: Compared with the control group, the cells cultured in media containing the extracts showed signs of apoptosis and necrosis after culturing for 4 or 7 days, and the loss rate for adherent cells was significantly increased (P < 0.05). An obvious decrease in cell viability was also observed (P < 0.05). CONCLUSION: The extracts from disposable chopsticks, toothpicks, and paper cups can affect the growth and proliferation of L-929 cells and are potentially toxic to humans.


Assuntos
Apoptose/efeitos dos fármacos , Qualidade de Produtos para o Consumidor , Utensílios de Alimentação e Culinária , Fibroblastos/efeitos dos fármacos , Papel , Extratos Vegetais/toxicidade , Madeira/química , Animais , Adesão Celular/efeitos dos fármacos , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , China , Células Clonais , Dispositivos para o Cuidado Bucal Domiciliar/efeitos adversos , Equipamentos Descartáveis , Fibroblastos/citologia , Fibroblastos/patologia , Camundongos , Necrose , Testes de Toxicidade , Madeira/efeitos adversos
11.
Sleep Breath ; 19(3): 769-74, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25245174

RESUMO

BACKGROUND: Expiratory positive airway pressure (EPAP) nasal devices provide a new therapeutic option for obstructive sleep apnea (OSA). METHODS: Here, we review the literature about treatment of OSA with EPAP, which has been shown to reduce the apnea/hypopnea index (AHI) and daytime sleepiness. RESULTS: Patients generally prefer EPAP to continuous positive airway pressure (CPAP), and there are no serious adverse effects from its use. Although CPAP more effectively improves sleep apnea, a recent study showed similar outcomes in symptom improvement using EPAP. Patients with mild to moderate OSA who do not tolerate CPAP are appropriate candidates for EPAP. However, there are few well-designed clinical trials that evaluate efficacy. CONCLUSIONS: More studies are needed to assess the efficacy of and compliance with EPAP nasal devices, to define which patients will benefit from EPAP therapy, and to compare EPAP to other alternative OSA therapies.


Assuntos
Respiração com Pressão Positiva/instrumentação , Apneia Obstrutiva do Sono/terapia , Equipamentos Descartáveis , Desenho de Equipamento , Humanos , Satisfação do Paciente , Qualidade de Vida/psicologia , Apneia Obstrutiva do Sono/psicologia , Resultado do Tratamento
12.
Biomed Mater Eng ; 24(6): 3589-96, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25227072

RESUMO

This paper proposes a bio-potential measurement apparatus including a wireless device for transmitting acupuncture bio-potential information to a remote control station for health conditions analysis and monitor. The key technology of this system is to make replaceable foam-rubber cushions, double-side conducting tapes, chip and antenna on the radio frequency identification (RFID) tag. The foam-rubber cushions can be wetted with salt-water and contact with the acupuncture points to reduce contact resistance. Besides, the double-side conducting tapes are applied to fix foam-rubber cushions. Thus, one can peel the used cushions or tapes away and supply new ones quickly. Since the tag is a flexible plastic substrate, it is easy to deploy on the skin. Besides, the amplifier made by CMOS technology on RFID chip could amplify the signals to improve S/N ratio and impedance matching. Thus, cloud server can wirelessly monitor the health conditions. An example shows that the proposed system can be used as a wireless health condition monitor, the numerical method and the criteria are given to analyze eleven bio-potentials for the important acupunctures of eleven meridians on a person's hands and legs. Then a professional doctor can know the performance of an individual and the cross-linking effects of the organs.


Assuntos
Equipamentos Descartáveis , Eletroacupuntura/instrumentação , Eletrodos , Dispositivo de Identificação por Radiofrequência , Processamento de Sinais Assistido por Computador/instrumentação , Telemedicina/instrumentação , Tecnologia sem Fio/instrumentação , Amplificadores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Cloreto de Sódio
13.
Anal Biochem ; 457: 85-90, 2014 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-24747413

RESUMO

In this work we present a rapid, selective, and highly sensitive detection of α-solanine and α-chaconine using cholinesterase-based sensors. The high sensitivity of the devices is brought by the use of a genetically modified acetylcholinesterase (AChE), combined with a one-step detection method based on the measurement of inhibition slope. The selectivity was obtained by using butyrylcholinesterase (BChE), an enzyme able to detect these two toxins with differential inhibition kinetics. The enzymes were immobilized via entrapment in PVA-AWP polymer directly on the working electrode surface. The analysis of the resulting inhibition slope was performed employing linear regression function included in Matlab. The high toxicity of α-chaconine compared to α-solanine due to a better affinity to the active site was proved. The inhibition of glycoalkaloids (GAs) mixture was performed over AChE enzyme wild-type AChE and BChE biosensors resulting in the detection of synergism effect. The developed method allows the detection of (GAs) at 50 ppb in potato matrix.


Assuntos
Acetilcolinesterase/metabolismo , Técnicas Biossensoriais/instrumentação , Butirilcolinesterase/metabolismo , Equipamentos Descartáveis , Solanina/análogos & derivados , Acetilcolinesterase/genética , Butirilcolinesterase/genética , Engenharia Genética , Solanina/química , Solanum tuberosum/química
14.
BMC Pregnancy Childbirth ; 13: 136, 2013 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-23800194

RESUMO

BACKGROUND: Every year an estimated three million neonates die globally and two hundred thousand of these deaths occur in Pakistan. Majority of these neonates die in rural areas of underdeveloped countries from preventable causes (infections, complications related to low birth weight and prematurity). Similarly about three hundred thousand mother died in 2010 and Pakistan is among ten countries where sixty percent burden of these deaths is concentrated. Maternal and neonatal mortality remain to be unacceptably high in Pakistan especially in rural areas where more than half of births occur. METHOD/DESIGN: This community based cluster randomized controlled trial will evaluate the impact of an Emergency Obstetric and Newborn Care (EmONC) package in the intervention arm compared to standard of care in control arm. Perinatal and neonatal mortality are primary outcome measure for this trial. The trial will be implemented in 20 clusters (Union councils) of District Rahimyar Khan, Pakistan. The EmONC package consists of provision of maternal and neonatal health pack (clean delivery kit, emollient, chlorhexidine) for safe motherhood and newborn wellbeing and training of community level and facility based health care providers with emphasis on referral of complicated cases to nearest public health facilities and community mobilization. DISCUSSION: Even though there is substantial evidence in support of effectiveness of various health interventions for improving maternal, neonatal and child health. Reduction in perinatal and neonatal mortality remains a big challenge in resource constrained and diverse countries like Pakistan and achieving MDG 4 and 5 appears to be a distant reality. A comprehensive package of community based low cost interventions along the continuum of care tailored according to the socio cultural environment coupled with existing health force capacity building may result in improving the maternal and neonatal outcomes. The findings of this proposed community based trial will provide sufficient evidence on feasibility, acceptability and effectiveness to the policy makers for replicating and scaling up the interventions within the health system.


Assuntos
Agentes Comunitários de Saúde/educação , Parto Obstétrico/instrumentação , Acessibilidade aos Serviços de Saúde , Tocologia/educação , Tocologia/instrumentação , Serviços de Saúde Rural/provisão & distribuição , Adolescente , Adulto , Peso ao Nascer , Equipamentos Descartáveis/provisão & distribuição , Feminino , Humanos , Recém-Nascido de Baixo Peso , Recém-Nascido , Serviços de Saúde Materna/provisão & distribuição , Mortalidade Materna , Pessoa de Meia-Idade , Paquistão , Educação de Pacientes como Assunto , Mortalidade Perinatal , Gravidez , Encaminhamento e Consulta , Projetos de Pesquisa , Adulto Jovem
16.
Neurourol Urodyn ; 32(5): 460-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23023996

RESUMO

AIMS: To test the null hypothesis that a novel disposable "tampon like" electrostimulation device (Pelviva(®)) is no better than unsupervised pelvic floor muscle exercise for treatment of urinary incontinence in women. METHODS: Pre/post-intervention assessor blinded, single center RCT. A total of 123 community dwelling self referred women with symptoms of stress, urge, or mixed incontinence were randomly assigned to one of two 12-week duration treatments: Pelviva(®) used for 30 min a day plus unsupervised pelvic floor muscle exercise or unsupervised exercises alone. Outcome measures included ICIQ-UI (primary), ICIQ FLUTSex and global impression of severity and improvement (secondary) completed at recruitment, after 4 weeks of unsupervised exercise and immediately post-treatment. Diary of exercise frequency/type, overall impression, and usage of device was completed mid- and post-treatment. RESULTS: Pelviva(®) plus exercise produced significantly better outcome than unsupervised exercise alone: 5 points (45%) versus 1 point (10%) for ICIQ-UI (P = 0.014); 67% versus 33% for leak frequency (P = 0.005); 40% versus 20% for leak interference with life (P = 0.018). Incontinence was less bothersome during sex to a greater extent in the Pelviva(®) group (P = 0.026). Women were enthusiastic about the device, found it comfortable/easy to use and experienced no adverse events. CONCLUSIONS: The Pelviva(®) device plus unsupervised exercise is more successful than unsupervised pelvic floor muscle exercise alone in treating urinary incontinence. The device is easy/comfortable to use, there are no apparent adverse incidents, and women can manage their incontinence in the privacy of their own home. The product will be launched 2013.


Assuntos
Equipamentos Descartáveis , Terapia por Estimulação Elétrica/instrumentação , Incontinência Urinária por Estresse/terapia , Incontinência Urinária de Urgência/terapia , Adulto , Terapia por Estimulação Elétrica/efeitos adversos , Inglaterra , Desenho de Equipamento , Feminino , Humanos , Modelos Lineares , Modelos Logísticos , Pessoa de Meia-Idade , Contração Muscular , Satisfação do Paciente , Diafragma da Pelve/fisiopatologia , Qualidade de Vida , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Comportamento Sexual , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento , Incontinência Urinária por Estresse/diagnóstico , Incontinência Urinária por Estresse/fisiopatologia , Incontinência Urinária de Urgência/diagnóstico , Incontinência Urinária de Urgência/fisiopatologia
17.
Bioanalysis ; 5(1): 21-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23256469

RESUMO

BACKGROUND: Disposable pipette extraction with reversed-phase sorbent is proposed for the fast and simple GC determination of the antipsychotic drugs chlorpromazine, olanzapine, clozapine and biperiden - an anticholinergic drug - in human urine. The method was validated and successfully applied to postmortem urine samples. The analytical run was 11 min and lidocaine was used as the internal standard. RESULTS: The developed method showed good linearity, over the range of 0.34 to 5 ng/µl, for all compounds. The within-day and between-day precision and accuracy assays revealed values ≤15%, while the recoveries ranged from 85 to 120%. LOD and LOQ ranged from 0.28 to 0.42 ng/µl and from 0.85 to 3.58 ng/µl, respectively. CONCLUSION: The developed method is a user-friendly technique, which is simple and fast.


Assuntos
Métodos Analíticos de Preparação de Amostras/instrumentação , Antipsicóticos/isolamento & purificação , Antipsicóticos/urina , Biperideno/isolamento & purificação , Biperideno/urina , Equipamentos Descartáveis , Urinálise/instrumentação , Antipsicóticos/química , Biperideno/química , Cromatografia Gasosa , Humanos , Nitrogênio/análise , Fósforo/análise , Reprodutibilidade dos Testes , Fatores de Tempo
18.
Anesth Analg ; 115(1): 31-7, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22504214

RESUMO

BACKGROUND: There is still controversy regarding the optimal strategy for managing postoperative nausea and vomiting (PONV) in high-risk surgical populations. Although acustimulation at the P6 acupoint has been demonstrated to be effective in preventing PONV, the effect of this nonpharmacologic therapy on the patient's recovery with respect to resumption of normal activities of daily living has not been previously assessed when it is used as part of a multimodal antiemetic regimen. Therefore, we designed this randomized, sham-controlled, and double-blind study to assess the efficacy of a disposable acupressure device (Pressure Right®; Pressure Point Inc., Grand Rapids, MI) on the incidence of emetic episodes and quality of recovery when used in combination with ondansetron and dexamethasone for antiemetic prophylaxis. METHODS: One hundred ASA physical status I and II patients undergoing major laparoscopic procedures were randomly assigned to either a control group (n = 50) receiving a "sham" acustimulation device or an acupressure group (n = 50) receiving a disposable Pressure Right device placed bilaterally at the P6 point 30 to 60 minutes before induction of anesthesia. All patients received a standardized general anesthetic. A combination of ondansetron, 4 mg IV, and dexamethasone, 4 mg IV, was administered during surgery for antiemetic prophylaxis in both study groups. The incidence of nausea and vomiting and the need for "rescue" antiemetic therapy were assessed at specific time intervals for up to 72 hours after surgery. The recovery profiles and quality of recovery questionnaires were evaluated at 48 hours and 72 hours after surgery. Patient satisfaction with the management of their PONV was assessed at the end of the 72-hour study period. RESULTS: The 2 study groups did not differ in their demographic characteristics or risk factors for PONV. The incidence of vomiting at 24 hours was significantly decreased in the acupressure group (10% vs 26%, P = 0.04, 95% confidence interval for absolute risk reduction 1%-31%). The overall incidence of vomiting from 0 to 72 hours after surgery was also significantly decreased from 30% to 12% in the acupressure group (P = 0.03, 95% confidence interval 2%-33%). Furthermore, adjunctive use of the acupressure device seemed to enhance patient satisfaction with their PONV management and quality of recovery at 48 hours after surgery. However, the recovery times to hospital discharge, resumption of normal physical activities, and return to work did not differ significantly between the 2 study groups. CONCLUSION: Use of the Pressure Right acupressure device in combination with antiemetic drugs provided a reduction in the incidence of vomiting from 0 to 72 hours after surgery with an associated improvement in patient satisfaction with their PONV management. However, recovery and outcome variables failed to demonstrate any improvement with the addition of the acupressure device.


Assuntos
Acupressão/instrumentação , Equipamentos Descartáveis , Laparoscopia/efeitos adversos , Náusea e Vômito Pós-Operatórios/prevenção & controle , Adulto , Antieméticos/administração & dosagem , Distribuição de Qui-Quadrado , Terapia Combinada , Dexametasona/administração & dosagem , Método Duplo-Cego , Desenho de Equipamento , Feminino , Humanos , Los Angeles , Masculino , Pessoa de Meia-Idade , Ondansetron/administração & dosagem , Satisfação do Paciente , Náusea e Vômito Pós-Operatórios/etiologia , Estudos Prospectivos , Antagonistas da Serotonina/administração & dosagem , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
19.
Nefrologia ; 31(6): 656-63, 2011.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-22130280

RESUMO

BACKGROUND: Despite the discrepancy in results from Spanish studies on the costs of dialysis, it is assumed that peritoneal dialysis (PD) is more efficient than haemodialysis (HD). OBJECTIVES: To analyse the costs and added value of HD and PD outsourcing agreements in Galicia, the medical transport for HD and the relationship between the cost of the agreement and the cost of consumables used in continuous ambulatory peritoneal dialysis (CAPD) with bicarbonate. METHODS: The cost of the outsourcing agreements and the staff was obtained from official publications. The cost of PD and medical transport were calculated using health service data for one month and extrapolating it to one year. The cost of CAPD consumables was provided by the suppliers. The added value was calculated from the investments generated for each agreement treating 40 patients. RESULTS: Expressed as patient/year, the mean costs for treatment were €21595 and €25664 in HD and PD, respectively. Medical transport varied between €3323 and €6338, while those of the CAPD agreement and consumables were €19268 and €12057, respectively. The added value was greater with the HD agreement, especially considering the jobs created. CONCLUSIONS: One cannot generalise that the cost of PD, which is significantly influenced by prescriptions, is lower than that of HD. It would be appropriate to review the additional cost to consumables in the CAPD agreement. The added value generated by dialysis agreements should be considered in future studies and in health planning. More controlled studies are needed to better understand this issue.


Assuntos
Serviços Terceirizados/economia , Diálise Peritoneal/economia , Diálise Renal/economia , Bicarbonatos/economia , Análise Custo-Benefício , Custos e Análise de Custo , Soluções para Diálise/economia , Equipamentos Descartáveis/economia , Financiamento Governamental/estatística & dados numéricos , Pessoal de Saúde/economia , Humanos , Falência Renal Crônica/economia , Falência Renal Crônica/terapia , Programas Nacionais de Saúde/economia , Diálise Peritoneal/instrumentação , Diálise Peritoneal Ambulatorial Contínua/economia , Mecanismo de Reembolso , Diálise Renal/instrumentação , Previdência Social/economia , Espanha , Transporte de Pacientes/economia
20.
Optom Vis Sci ; 87(7): E475-81, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20473237

RESUMO

PURPOSE: This study was designed to qualitatively and quantitatively characterize the surface morphology of four unworn conventional hydrogel contact lenses (omafilcon, hioxifilcon, nelfilcon A, and ocufilcon B) and two silicone-hydrogel contact lenses (senofilcon A and comfilcon A) without surface treatment. METHODS: Surface roughness was assessed using atomic force microscopy in Tapping Mode to determine the representative roughness parameters mean surface roughness (Ra), mean square roughness (Rms), kurtosis (Rku), and skewness (Rsk). To date, these last two parameters have not been used to characterize contact lens surfaces. Rku provides information on the distribution of spikes above and below the mean line, and Rsk provides information about the asymmetric roughness of surfaces. The surface topography of the lenses was also mapped in detail. RESULTS: In all the lenses, higher Ra and Rms values were obtained when larger surface areas were examined. The daily replacement contact lenses (nelfilcon A and ocufilcon B) showed the highest Ra and Rms values but according to their Rku scores, their surface profiles were less spiky than the remaining lenses. On the contrary, the lowest Ra and Rms values were recorded for comfilcon A and omafilcon A, which also exhibited the spikiest surface profiles. All the materials except the hioxifilcon showed a predominance of peaks (Rsk >0) over troughs. CONCLUSIONS: The shape parameters Rku and Rsk are useful for characterizing contact lens surfaces, because they provide different yet complementary information to that offered by Ra and Rms. Precise knowledge of the shape profile of a contact lens surface will give an idea of its susceptibility to deposit formation or colonization by microorganisms.


Assuntos
Lentes de Contato Hidrofílicas , Microscopia de Força Atômica , Equipamentos Descartáveis , Desenho de Equipamento , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Silicones , Propriedades de Superfície