Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 299
Filtrar
Mais filtros

Medicinas Complementares
Tipo de documento
Intervalo de ano de publicação
1.
J Agric Food Chem ; 72(11): 5975-5982, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38462975

RESUMO

Due to the high toxicity of aflatoxin B1 and its risks to human health, we developed a click reaction-mediated automated fluorescent immunosensor (CAFI) for sensitive detection of aflatoxin B1 based on the Cu(I)-catalyzed click reaction. With its large specific surface area, a copper-based metal-organic framework (Cu-MOF) was synthesized to adsorb and enrich the copper ion (Cu(II)) and then load the complete antigen (BSA-AFB1). After the immunoreaction, Cu(II) inside the Cu-MOF-Antigen conjugate would be reduced to Cu(I) in the presence of sodium ascorbate, which triggered the click reaction between the fluorescent donor-modified DNA and the receptor-modified complementary DNA to lead to a fluorescence signal readout. The whole reaction steps were finished by the self-developed automated immunoreaction device. This CAFI method showed a limit of detection (LOD) of 0.48 pg/mL as well as a 670-fold enhancement in sensitivity compared to conventional ELISA, revealing its great potential in practical applications and automated detection.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Humanos , Cobre , Aflatoxina B1/análise , Imunoensaio/métodos , Técnicas Biossensoriais/métodos , Corantes , Limite de Detecção
2.
J Agric Food Chem ; 71(41): 14967-14978, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37803933

RESUMO

The synthesis of a hapten and antigen for the preparation of a monoclonal antibody (mAb) for buprofezin is described. The recognition mechanism of hapten and buprofezin by monoclonal antibodies (mAb-19F2) is described. The effectiveness of the mAb-19F2 immunoassay technique was assessed, and the effective detection of buprofezin in tea samples was achieved through the establishment of indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) and colloidal gold immunochromatography assay (GICA). The mAb-19F2 subtype was IgG1, with an IC50 of 1.8 ng/mL and a linear range (IC20-IC80) of 0.6-5.4 µg/L, and had a cross-reaction rate of less than 0.18% with 29 other pesticides (neonicotinoids and insect growth regulators). The study identified π-π stacking interactions between hapten and TYR-61 at the mAb-19F2 site and alkyl/phosphate interactions with TRP-105 and ARG-103. The ic-ELISA had an IC50 of 12.9 ng/mL in green tea and 5.65 ng/mL in black tea, with a recovery rate of 92.4%-101.0% and RSD of 2.1%-4.8%. The GICA had a limit of detection (LOD) was 500 ng/mL, with the complete disappearance of the test lines visible to the naked eye. The limit of quantitation (LOQ, IC20) was determined to be 16.8 ng/mL. Additionally, the developed GICA showed no cross-reactivity with neonicotinoid pesticides. The recovery rate of tea spiked recovered samples was 83.6%-92.2%, with an RSD of 5.3%-12.6%, and the results were consistent with the LC/MS method. This study is important for the real-time detection of buprofezin residues to ensure food safety and human health.


Assuntos
Anticorpos Monoclonais , Praguicidas , Humanos , Anticorpos Monoclonais/química , Imunoensaio/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Haptenos , Neonicotinoides , Chá
3.
J Appl Lab Med ; 8(5): 856-870, 2023 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-37473432

RESUMO

BACKGROUND: Vitamin D supplementation is common practice for neonates and infants due to limited stores of vitamin D at birth. Although not commonly encountered, vitamin D toxicity can occur due to over-supplementation. However, toxic concentrations are often not included in method validation experiments, and assays often are not validated in the neonatal population. METHODS: We compared serial 25 hydroxy vitamin D [25(OH)D] measurements in pre-term neonates receiving 25(OH)D supplementation and identified 12 patients wherein concentrations of 25(OH)D were above 50 ng/mL (125 nM) that required additional investigations as the 25(OH)D results did not match the clinical picture. Available samples were compared across 4 immunoassay platforms (LIAISON XL, Roche Cobas e602, Abbott Alinity i, and Siemens Centaur XP) and LC-MS/MS. RESULTS: Concentrations of 25(OH)D observed on one individual immunoassay platform (LIAISON XL) fluctuated substantially between subsequent blood draws in select neonates with elevated concentrations. Serum samples from these patients showed variable agreement between LC-MS/MS and other immunoassay platforms. These fluctuations were not explained by the presence of 3-epimer-25(OH)D or 24,25(OH)2D. CONCLUSIONS: Although we were unable to identify a cause for the variable elevated results, our findings suggest that neonatal 25(OH)D measurements alone should not be used for assessment of nutritional monitoring, and that clinical correlation and other laboratory parameters including ionized calcium should be considered.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Recém-Nascido , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Imunoensaio/métodos , Laboratórios
4.
Clin Chem ; 69(7): 754-762, 2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37253044

RESUMO

BACKGROUND: Human chorionic gonadotropin (hCG) detection is indicative of pregnancy and can be indicative of some forms of cancerous tumors. The hCG drug itself, however, is a performance enhancing substance used by male athletes to increase testosterone production. Antidoping testing for hCG is conducted in urine, often on immunoanalyzer platforms, many of which utilize biotin-streptavidin dependent immunoassays in which the presence of biotin in samples is a known confounding factor. While biotin interference in serum has been well-studied, the extent of biotin interference in urine has not. METHODS: Ten active male individuals underwent a 2-week hCG administration protocol concurrent with supplementation with biotin (20 mg/day) or placebo. Urine and serum samples were collected throughout the study and analyzed for hCG and biotin concentrations. RESULTS: Urinary biotin levels in the hCG + biotin group increased 500-fold over baseline and 29-fold over corresponding serum biotin levels after biotin supplementation. When using a biotin-dependent immunoassay, the hCG + placebo group produced hCG-positive results (hCG ≥ 5 mIU/mL) in 71% of urine samples, while the hCG + biotin group produced positive results in only 19% of samples. Both groups had elevated hCG values in serum measurements by a biotin-dependent immunoassay and in urine when using a biotin-independent immunoassay. Urinary hCG measurements and biotin levels from the hCG + biotin group showed a negative correlation (Spearman r = -0.46, P < 0.0001) when measured using a biotin-dependent immunoassay. CONCLUSIONS: Biotin supplementation can severely suppress urinary hCG values in assays utilizing biotin-streptavidin binding methods and therefore these types of assays are not recommended for use in urine samples containing high levels of biotin. Clinicaltrials.gov Registration Number: NCT05450900.


Assuntos
Biotina , Gonadotropina Coriônica , Gravidez , Feminino , Humanos , Masculino , Estreptavidina , Imunoensaio/métodos , Suplementos Nutricionais
5.
Mikrochim Acta ; 190(6): 232, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37213023

RESUMO

A simple label-free electrochemical immunosensor for ovarian cancer (OC) detection was developed using a hierarchical microporous carbon material fabricated from waste coffee grounds (WCG). The analysis method exploited near-field communication (NFC) and a smartphone-based potentiostat. Waste coffee grounds were pyrolyzed with potassium hydroxide and used to modify a screen-printed electrode. The modified screen-printed electrode was decorated with gold nanoparticles (AuNPs) to capture a specific antibody. The modification and immobilization processes were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The sensor had an effective dynamic range of 0.5 to 50.0 U mL-1 of cancer antigen 125 (CA125) tumor marker with a correlation coefficient of 0.9995. The limit of detection (LOD) was 0.4 U mL-1. A comparison of the results obtained from human serum analysis with the proposed immunosensor and the results obtained from the clinical method confirmed the accuracy and precision of the proposed immunosensor.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Neoplasias Ovarianas , Feminino , Humanos , Carbono , Nanopartículas Metálicas/química , Ouro/química , Café , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Neoplasias Ovarianas/diagnóstico
6.
Talanta ; 260: 124586, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37105083

RESUMO

Ochratoxin A (OTA) is a nephrotoxic and carcinogenic mycotoxin frequently found in coffee, which directly impacts human health and the economy of many countries. For this reason, there has been a growing need for simple and sensitive tools for the on-site detection of this mycotoxin. In this study, we developed a label-free impedimetric immunosensor to detect OTA. The biosensor was built on a thin-film gold electrode evaporated on glass substrtes, modified with a self-assembled cysteamine monolayer and anti-OTA antibodies. Atomic force microscopy and Microspectroscopy RAMAN confirmed the successful functionalization of the electrodes. The biosensor performance was evaluated by electrochemical impedance spectroscopy and the measurements indicated a linear relationship between the change in the impedance values and the OTA concentration in the range from 0.5 to 100 ng mL-1 with a limit of detection of 0.15 ng mL-1. The biosensor was highly selective and did not suffer matrix interference when analyzed in coffee samples. Furthermore, considering the small sample volumes, the short time required for analysis, and the possibility of miniaturization, the developed biosensor represents a promising analytical device for on-site coffee quality analyses.


Assuntos
Técnicas Biossensoriais , Micotoxinas , Humanos , Café , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Eletrodos , Técnicas Eletroquímicas/métodos , Limite de Detecção
7.
Appl Microbiol Biotechnol ; 107(9): 2887-2896, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36995382

RESUMO

Immunoassays are efficient for the phytochemical analysis of various matrices. However, producing an appropriate recombinant antibody for small molecules is challenging, resulting in costly analyses. In this study, we aimed to develop recombinant fragment antigen-binding (Fab) antibodies against miroestrol, a potent phytoestrogen marker of Pueraria candollei. Two expression cassettes of Fab were established for the production of active Fab antibodies using SHuffle® T7 Escherichia coli cells. The orientation of variable fragment heavy chain (VH) and variable fragment light chain (VL) in the expression vector constructs influences the reactivity, stability, and binding specificity of the resultant Fab. Stability testing of antibodies demonstrated that Fab is a more stable form of recombinant antibody than a single-chain variable fragment (ScFv) antibody in all conditions. Based on the obtained Fab, the ELISA specifically detected miroestrol in the range of 39.06-625.00 ng/mL. The intra- and inter-assay precisions were 0.74-2.98% and 6.57-9.76%, respectively. The recovery of authentic miroestrol spiked into samples was 106.70-110.14%, and the limit of detection was 11.07 ng/mL. The results for P. candollei roots and products determined using our developed ELISA with Fab antibody and an ELISA with anti-miroestrol monoclonal antibody (mAb) were consistent (R2 = 0.9758). The developed ELISA can be applied for the quality control of miroestrol derived from P. candollei. Therefore, the appropriate expression platform of Fab resulted in the stable binding specificity of the recombinant antibody and was applicable for immunoassays.Key points• ELISAs with Fab has higher sensitivity than that with ScFv.• Fab is more stable than ScFv.• Fab-based ELISA can be used for miroestrol determination of Pueraria candollei.


Assuntos
Pueraria , Anticorpos de Cadeia Única , Ensaio de Imunoadsorção Enzimática/métodos , Fitoestrógenos/análise , Imunoensaio/métodos , Anticorpos de Cadeia Única/genética , Pueraria/química , Escherichia coli/genética
8.
Anal Methods ; 15(4): 529-536, 2023 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-36628955

RESUMO

With the popularity of herbal tea in China, many food fraudsters have added illegal drugs to herbal tea to enhance its functions, among which aminopyrine is widely abused as an antipyretic and analgesic. Presently, there is no immunoassays for aminopyrine, and it is difficult to achieve real-time detection in the field. Based on a polyclonal antibody of aminopyrine with high specificity and sensitivity, an optimal combination of coating antigen/antibody was obtained by screening different coating antigens. On this basis, a sensitive ic-ELISA method was established to detect aminopyrine in herbal tea. The detection limit of the ic-ELISA was 0.18 ng mL-1, which was much lower than the 100 ng mL-1 required as a standard. The method had good consistency with LC-MS in the detection of actual samples and could be used as a reliable method for the detection of aminopyrine in herbal tea.


Assuntos
Chás de Ervas , Aminopirina , Imunoensaio/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos
9.
Biosens Bioelectron ; 222: 115001, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36516634

RESUMO

P-glycoprotein (P-gp), a transmembrane glycoprotein widely expressed on the surface of various cells, is highly associated with multidrug resistance (MDR) that heralds the malignant progress of disease after drug treatment. Notably, there have been reported that serum P-gp is a potential marker for assessing the progression of disease resistance. Currently, there are few methods for point-of-care serum P-gp detection. In this study, we proposed a gold nanoparticles/electrochemically reduced graphene oxide@carbon nanotube (AuNPs/ERGO@CNT) modified immunosensor based on a one-step electrochemical co-reduction method. The limit of detection (LOD) of our constructed electrochemical immunosensor for P-gp detection reached 0.13 ng/mL, and the detection results in serum were consistent with ELISA. The developed immunosensor is expected to provide a scientific basis for the clinical application of serum P-gp monitoring and integrated medicine.


Assuntos
Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , Nanocompostos , Ouro , Imunoensaio/métodos , Membro 1 da Subfamília B de Cassetes de Ligação de ATP , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Limite de Detecção , Subfamília B de Transportador de Cassetes de Ligação de ATP
10.
Food Chem ; 404(Pt A): 134482, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36252380

RESUMO

Hormone residues in food and drinking water endanger human health, therefore, on-site analysis techniques of superior performance are important for monitoring this risk. In this study, an ultra-sensitive photothermal lateral flow immunoassay (LFIA) for quantification of 17ß-estradiol (E2) has been developed. Anti-E2 antibody modified black phosphorus-Au (BP-Au) nanocomposite was developed as a photothermal contrast signal probe and the temperature at test-zone was recorded with an infrared camera. Under the irradiation of 808 nm laser at test-zone, it gave temperatures negatively related to the concentrations of E2 in samples. Under optimal detecting conditions, the developed photothermal LFIA exhibited a limit of detection of 50 pg mL-1, over 100-fold more sensitive than visual LFIA, and a linear range of 3 orders of magnitude. This method has been successfully applied to water, milk, and milk powder samples.


Assuntos
Estradiol , Leite , Humanos , Animais , Limite de Detecção , Imunoensaio/métodos , Estradiol/análise , Leite/química , Fósforo/análise , Anticorpos , Ouro/química
11.
Food Chem ; 404(Pt A): 134552, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36272299

RESUMO

Immunochromatographic methods are acknowledged analytic assay to analyze capsaicinoids. Immunomagnetic solid-phase extraction (IMSPE) coupled with time-resolved fluorescence immunochromatographic assay (TRFICA) was proposed to quantify capsaicinoids in oil samples. Monoclonal antibodies (mAb) were synthesized with CNBr-Magnetic Crystarose 4B particles (CNBr-MCPs) under mild condition. The resultant CNBr-MCPs@mAb were conjugated high affinity mAbs on its surface, which was utilized to extract capsaicinoids from lipid matrices via antibodies-antigens capture. Under the optimized conditions, the whole IMSPE procedure was achieved within 15 min, and quantified by TRFICA strips. The results showed coefficients up to 0.9975 and the visual detection limit as low as 0.6 µg kg-1. The recoveries were ranging from 88.3 % to 112.4 % with the intra-day and inter-day precision lower than 11.6 %. Finally, the proposed IMSPE-TRFICA method was successfully used to detect capsaicinoids in lipid matrices, which has great utility to quantify capsaicinoids and adulteration detect vegetable oils.


Assuntos
Óleos de Plantas , Extração em Fase Sólida , Extração em Fase Sólida/métodos , Imunoensaio/métodos , Cromatografia de Afinidade/métodos , Óleos de Plantas/química , Contaminação de Alimentos/análise , Anticorpos Monoclonais
12.
Food Chem ; 406: 135065, 2023 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-36462351

RESUMO

Aminopyrine is a nonsteroidal anti-inflammatory drug only for medical purposes, however, it has been illegally added in traditional Chinese herbal teas for fraud activity recently. In this study, a specific antibody against aminopyrine with IC50 of 3.00 ng/mL was obtained for the first time by a rational hapten design. Furthermore, an ultrasensitive gold nanoparticles immunochromatographic assay (AuNPs-ICA) for determination of aminopyrine based on a portable reader was firstly developed, with cut-off value of 100.00 ng/mL, limit of detection (LOD) of 4.80 ng/mL and limit of quantification (LOQ) of 5.71 ng/mL for herbal tea, respectively. The recovery rates ranged from 93.21 % to 105.61 %, with inter-assay coefficient of variation (CV) from 1.08 % to 3.82 %. Additionally, 24 blind samples were examined simultaneously by AuNPs-ICA and LC-MS/MS, demonstrating a good consistency for each other. The proposed AuNPs-ICA is an ultrasensitive and reliable tool for on-site surveillance screening of fraud additives in herbal tea.


Assuntos
Nanopartículas Metálicas , Chás de Ervas , Ouro/química , Cromatografia Líquida , Aminopirina , Nanopartículas Metálicas/química , Espectrometria de Massas em Tandem , Imunoensaio/métodos , Limite de Detecção , Cromatografia de Afinidade/métodos
13.
Nanotechnology ; 33(48)2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-35998539

RESUMO

In this work, an electrochemical immunosensor based on black phosphorus nanosheets (BPNS)/poly(allylamine hydrochloride) (PAH) nanocomposite modified glassy carbon electrode was developed for the detection of ovarian cancer biomarker HE4. PAH has been applied to retain BPNS in its original honeycomb structure and to anchor biomolecules electrostatically on the transducer surface. The as synthesized nanocomposite was characterized by zeta potential analysis, scanning electron microscopy, x-ray photoelectron spectroscopy, transmission electron microscopy, high-resolution transmission electron microscopy. Subsequently, the performance of the electrochemical immunosensor was evaluated through cyclic voltammetry, differential pulse voltammetry and electrochemical impedance spectroscopy. Under the optimal condition, the developed electrochemical immunosensor permitted to detect HE4 with a linear range of 0.1-300 ng ml-1and a detection limit of 0.01 ng ml-1. The developed sensor exhibited good selectivity and specificity to HE4 with negligible interference effect from common biomolecules like bovine serum albumin, lysozyme, protamine, glucose, fructose, hemoglobin and fetal bovine serum. Further, practical application of developed electrochemical immunosensor was demonstrated in spiked human serum which showed satisfactory recovery percentages.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Eletrodos , Humanos , Imunoensaio/métodos , Limite de Detecção , Fósforo , Poliaminas
14.
Ann Clin Lab Sci ; 52(3): 504-506, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35777806

RESUMO

OBJECTIVE: Total and free prostate specific antigens (PSA) have been used as diagnostic markers for monitoring progress of therapy in patients with prostate cancer as well as for screening purpose. Roche total and free PSA immunoassay utilizes biotinylated antibody in assay design. As a result, both assays are affected by elevated serum biotin levels. Recently, Roche reformulated these assays to reduce biotin interference. We evaluated biotin interference in these products. MATERIALS AND METHODS: We prepared three serum pools with one pool containing high amount of total PSA. Then aliquots of each serum pool were further supplemented with various concentrations of biotin (100-1500 ng/mL) followed by measuring both total and free PSA using Roche total and free PSA immunoassay and Cobas e411 analyzer. RESULTS: We observed no significant interference of biotin in both total and free PSA assays up to biotin concentration of 1200 ng/mL. CONCLUSION: We concluded that newly reformulated total and free PSA immunoassays are virtually free from biotin interference.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Biotina/química , Humanos , Imunoensaio/métodos , Masculino , Antígeno Prostático Específico/química , Neoplasias da Próstata/diagnóstico
15.
BMC Womens Health ; 22(1): 232, 2022 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-35710471

RESUMO

BACKGROUND: The optimal management of patients in reproductive endocrinology relies on the accuracy and validity of sex hormone assays. Endogenous or exogenous substances can compete with the analyte. This competition can result in interfering errors and falsely indicate elevated serum levels. Obvious interference in estradiol assays appears to occur rarely. Consequently, clinicians who are not familiar with the potential of interference could be misled. In addition to unnecessary investigations and interventions and severe mental stress, falsely elevated estradiol results can result in missed or delayed fertility opportunities. CASE: A 28-year-old female with pregnancy demand was diagnosed with polycystic ovary syndrome, Hashimoto's thyroiditis and subclinical hypothyroidism. She was found to have persistently elevated levels of serum estradiol in the early follicular phase (between 527 and 642 pg/mL). Screening workup was performed for nearly 11 months to find the causes. Serum tumor biomarkers were normal. Abdominal and pelvic computed tomography were negative for adrenal or adnexal masses. A left mesosalpinx cyst and benign pathological results were achieved by laparoscopic surgery. Hormonal substances and dietary supplements were absent, as determined by dietary records. Ultrasound confirmed follicles could grow slowly and eventually ovulate. Falsely elevated estradiol levels were suspected due to the discrepancy among high estradiol levels, follicle growth and normal gonadotropin levels. Immunological interference by heterophile antibody was finally verified by two competitive chemiluminescent immunoassay platforms (estradiol levels in the early follicle phase: 619 pg/mL, Siemens ADVIA CENTAUR and 60 pg/mL, Beckman, DxI 800). Successful clinical pregnancy was eventually achieved by combining induced ovulation, ultrasound monitoring and intercourse guidance. CONCLUSIONS: Analytical interference and laboratory error should be suspicious at first when the clinical characteristics contradict the laboratory results of serum hormones. Measuring serum estradiol with another immunoassay platform is an easy and non-time-consuming method to exclude the heterophile interfering.


Assuntos
Anticorpos Heterófilos , Hipotireoidismo , Adulto , Estradiol , Feminino , Fertilidade , Humanos , Imunoensaio/métodos , Gravidez
16.
Biosens Bioelectron ; 207: 114148, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35286945

RESUMO

It is tremendously desirable for the timely and effective detection of cancer to facilitate the ultra-highly sensitive monitoring of tumor marker in clinical serum sample. In this study, an electromagnetic and chemical synergistically enabled recyclable immunoassay based on surface-enhanced Raman scattering (SERS) was proposed by realizing the anisotropic growth of sea-urchin-like gold nanoflowers (Au NFs) on two-dimensional red phosphorus (RP) nanoplates. Besides the achieved enhancement factor as high as 2.24 × 106, it was found that the photocatalytic and SERS activities were kept at a high level for the hybrid substrate of RP/Au NFs throughout 7 cycles of immunoassay. In combination with a non-metallic immunoprobe, the limit of detection was drove to 7.41 × 10-5 IU·mL-1 for cancer antigen 19-9. The comparative experiments of nonspecific monitoring verified the promising selectivity of this strategy. Considering the intriguing features of high sensitivity, recyclability, and specificity, the proposed multifunctional RP/Au NFs exhibited its superior role in the early detection of cancer and can be adapted for point-of-care diagnosis.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Antígeno CA-19-9 , Ouro , Imunoensaio/métodos , Fósforo , Análise Espectral Raman/métodos
17.
Ther Drug Monit ; 44(5): 683-695, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35358108

RESUMO

BACKGROUND: A high-throughput and highly efficient analytical platform for urine drug screening is critical in both clinical and forensic settings. Mass spectrometry (MS) has better sensitivity and specificity than conventional immunoassays (IA); however, not all laboratories have the necessary resources and workforce to operate MS. The goal of this study was to evaluate a multidrug biochip with 20 discrete testing regions (DTRs) for high-throughput urine drug screening (UDS). METHODS: The Randox DOA Ultra Urine (DOAULT URN) biochip employs chemiluminescent IA to detect various analytes, including stimulants, hallucinogens, sedatives, narcotics, and dextromethorphan. The verification included the evaluation of the limits of detection (LOD), stability of calibrators and controls, cross-reactivity, carryover, interference, and overall performance. RESULTS: LODs < quality control low for each DTR. The reconstituted calibrators were stable for up to 2 weeks at -20°C. Controls were stable for 4-6 hours at 22-25°C, with <20% within-day and ≤23% between-day imprecision. The accuracy of the controls (%bias) was within ±20% of the target concentration, except for dextromethorphan at -23.8%. No interference was observed with common over-the-counter medications. No carryover was detected in the high-concentration samples. Satisfactory cross-reactivity (≥50%) with known analytes produced presumptive positive results, with readings higher than the proposed decision points. The overall biochip performance of 165 confirmed samples showed 98.0% sensitivity, 96.9% specificity, and 97.5% efficiency. CONCLUSIONS: The DOAULT URN biochip is a multidrug analyte IA capable of detecting dozens of parent drugs and their metabolites in urine. It offers clinical and forensic laboratories an alternative UDS tool with LODs comparable to those of MS.


Assuntos
Dextrometorfano , Tecnologia , Avaliação Pré-Clínica de Medicamentos , Humanos , Imunoensaio/métodos , Limite de Detecção
18.
J Lipid Res ; 63(5): 100204, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35337847

RESUMO

Vitamin D is an important fat-soluble prohormone with pleiotropic effects on human health, such as immunomodulation of the innate and adaptive immune system. There is an unmet clinical need for a rapid screening platform for 25-hydroxyvitamin D (25OH-D) determination without chromatographic separation that offers better precision and accuracy than immunoassays. Here, we introduce a high-throughput method for assessing vitamin D status from blood specimens based on direct infusion-MS/MS (DI-MS/MS) following click derivatization using 2-nitrosopyridine. We developed an optimized liquid-phase extraction protocol to minimize ion suppression when directly infusing serum or plasma extracts via a capillary electrophoresis system for quantitative determination of 25OH-D. Acceptable reproducibility (mean coefficient of variation = 10.9%, n = 412), recovery (mean = 102% at 15, 30, and 45 nmol/l), and linearity (R2 > 0.998) were achieved for 25OH-D with lower detection limits (limit of detection ∼1.2 nmol/l, S/N ∼ 3), greater throughput (∼3 min/sample), and less bias than a commercial chemiluminescence immunoassay prone to batch effects. There was mutual agreement in 25OH-D concentrations from reference blood samples measured by DI-MS/MS as compared with LC-MS/MS (mean bias = 7.8%, n = 18). We also demonstrate that this method could reduce immunoassay misclassification of vitamin D deficiency in a cohort of critically ill children (n = 30). In conclusion, DI-MS/MS offers a viable alternative to LC-MS/MS for assessment of vitamin D status in support of large-scale studies in nutritional epidemiology as well as clinical trials to rapidly screen individual patients who may benefit from vitamin D supplementation.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Calcifediol , Criança , Cromatografia Líquida/métodos , Humanos , Imunoensaio/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Vitaminas
19.
J Nat Med ; 76(3): 521-545, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35171397

RESUMO

Phytoproducts are involved in various fields of industry. Small-molecule (Mw < 900 Da) organic compounds can be used to indicate the quality of plant samples in the perspective of efficacy by measuring the necessary secondary metabolites and in the perspective of safety by measuring the adulterant level of toxic compounds. The development of reliable detection methods for these compounds in such a complicated matrix is challenging. The lateral flow immunoassay (LFA) is one of the immunoassays well-known for its simplicity, portability, and rapidity. In this review, the general principle, components, format, and application of the LFA for phytoproducts are discussed.


Assuntos
Imunoensaio , Compostos Fitoquímicos , Imunoensaio/métodos , Compostos Fitoquímicos/isolamento & purificação
20.
Ann Clin Lab Sci ; 52(1): 161-163, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35181630

RESUMO

OBJECTIVE: Interleukin -6 (IL-6) is an important diagnostic test in COVID-19 patients to determine whether to initiate tocilizumab therapy or mechanical ventilation. We investigated potential interference of biotin in Roche IL-6 assay which utilizes biotinylated antibody. METHODS: We prepared three serum pools from left-over specimens which showed IL-6 values over 40 pg/mL. Then aliquots of each serum pool were further supplemented with various amounts of biotin expected in patients taking biotin supplement and then IL-6 values were measured again using Roche IL-6 assay on the Cobas e411 analyzer. RESULTS: We observed negative interference of biotin in IL-6 assay but interference was bimodal as maximum negative interference was observed with 100 ng/mL biotin but not with 1000 ng/mL. However, no interference was observed in the presence of 25 ng/mL biotin. CONCLUSIONS: Biotin showed negative interference with IL-6 assay.


Assuntos
Biotina/sangue , Imunoensaio/métodos , Interleucina-6/sangue , Artefatos , Biotina/farmacologia , COVID-19/sangue , Suplementos Nutricionais , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA