Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Bodyw Mov Ther ; 36: 62-68, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37949601

RESUMO

OBJECTIVES: The stiffness of median nerve increases in carpal tunnel syndrome (CTS) even at mild stage of syndrome which could be regarded as a diagnostic criterion. The aim of this study was to evaluate the immediate effects of neurodynamic technique on median nerve stiffness and cross-sectional area (CSA) at wrist and elbow in individuals with CTS. MATERIAL AND METHODS: It was a quasi-experimental study. Twenty patients were recruited for this study. They were included if aged 18-65 years and diagnosed with CTS based on electrodiagnostic and clinical findings. The exclusion criteria were previous surgeries at wrist or elbow. Patients were assessed by shear wave sono-elastography before and immediately after one session of neurodynamic mobilization technique (NDM). The primary outcome measure was the stiffness of the median nerve at wrist and the secondary outcomes were nerve stiffness at elbow and CSA of nerve at wrist and elbow. RESULTS: Median nerve stiffness and CSA decreased significantly at wrist immediately after a session of NDM. These parameters also decreased at elbow but were not statistically significant. CONCLUSION: One session of NDM reduced the stiffness and CSA of median nerve at wrist in patients with CTS as detected by sono-elastography verifying that sono-elastography is able to quickly detect the immediate biomechanical changes of the median nerve.


Assuntos
Síndrome do Túnel Carpal , Técnicas de Imagem por Elasticidade , Articulação do Cotovelo , Humanos , Nervo Mediano/diagnóstico por imagem , Síndrome do Túnel Carpal/diagnóstico por imagem , Punho/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia
2.
Lasers Med Sci ; 38(1): 248, 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37906312

RESUMO

The aim of this study was to evaluate the effects of high intensity laser therapy (HILT) on pain, functional status, hand grip strength, and median nerve cross-sectional area by ultrasonography in patients with carpal tunnel syndrome. Sixty patients who were diagnosed with carpal tunnel syndrome were included in the study. The patients observed during the research were randomly divided into two groups with 30 patients in each group. Splint+ exercise and HILT (pulsed mode with a power of 8.0 W and energy density of 8 J/cm2 for 1.40 minutes for every 25 cm2, continuous mode with a power of 3.0 W and energy density of 80 J/cm2 for 11 minutes for each 25 cm2; total 10 sessions 5 days a week) were applied for 2 weeks for the first group, and splint+exercise and sham laser treatment were applied for 2 weeks for the second group. Randomization was undertaken with the assistance of a computer-generated random number table before beginning the treatment processes. The patients were evaluated with the determined scales before the treatment, at the end of the treatment, and at the 3rd month. Hydraulic hand dynamometer was used to measure hand grip strength, visual analog scale (VAS) for pain, Boston CTS Questionnaire to assess function, and ultrasonography to measure median nerve cross-sectional area. The impact of time on the change in VAS levels was found to be of statistical significance within each group of patients (p<0.001), but between-group comparisons did not yield significant results (p<0.454). The effects of time on variations in Boston CTS Questionnaire scores were found to have been of statistical significance for both groups (p<0.001), but significance was not subsequently observed when the results of the two groups were compared on a between-group basis (p=0.226 and p=0.973 for the FSS and SSS, respectively). While time had a statistically significant effect on the change in hand grip strength for both groups (p=0.000), between-group comparisons statistical significance finding in favor of HILT was found in the early period (p=0.012). The time-group association patterns of the groups showed significant difference (p=0.025). While time had a statistically significant effect on the changes in the median cross-sectional areas of the nerve for the patients of both treatment groups (p<0.001), between-group comparisons yielded no findings of statistical significance (p=0.438). The time-group relationship patterns of the groups were found to reflect statistical significance (p=0.001). In conclusion, the results of the research presented here have confirmed that hand grip strength may increase and the median nerve's cross-sectional area may decrease upon the application of high-intensity laser for individuals experiencing CTS. However, this effect was demonstrated here only in the short-term and the evidence was not maintained through the course of follow-up of a longer duration.


Assuntos
Síndrome do Túnel Carpal , Terapia com Luz de Baixa Intensidade , Humanos , Nervo Mediano/diagnóstico por imagem , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/radioterapia , Força da Mão , Estado Funcional , Terapia com Luz de Baixa Intensidade/métodos , Ultrassonografia , Dor , Resultado do Tratamento
3.
J Bodyw Mov Ther ; 35: 57-63, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37330803

RESUMO

OBJECTIVE: To explore effect of cupping and Kinesio-taping techniques on clinical and ultrasound outcomes of carpal tunnel syndrome (CTS) during pregnancy. METHODS: Thirty pregnant women suffering from CTS were randomly assigned into Kinesio-taping (n = 15) and cupping (n = 15) groups. In Kinesio-taping group, individuals underwent Kinesio-taping for three days, one day with no treatment, and three days with Kinesio-taping, continuing this procedure for four weeks. In cupping group, cupping was moved for 5 min with pressure of 50 mm-Hg on the carpal tunnel area. This procedure continued longitudinally in forearm area for 2 min. The therapeutic intervention of cupping group continued with eight sessions, two days a week for 4 weeks. Ultrasound outcomes including median nerve cross-sectional area through ultrasonography, and clinical outcomes including pain through visual analog scale and severity of symptoms and functional status through Boston questionnaire were measured in both groups before and after therapeutic program. RESULTS: In both groups, a significant reduction was observed in all variables after treatment compared to pre-treatment (P < 0.001). In inter-group comparison, a significant improvement was found in outcomes of Boston questionnaire and ultrasound results about median nerve cross-sectional area at pisiform and hook of hamate in cupping group compared to Kinesio-taping at end of four weeks (P < 0.001). CONCLUSION: Both cupping and Kinesio-taping improved clinical and ultrasound outcomes of CTS. However, efficacy of cupping compared to Kinesio-taping was better in improvement of median nerve cross-sectional area at hamate hook and pisiform levels, symptoms severity scale, and functional status scale, which makes the results clinically more applicable.


Assuntos
Fita Atlética , Síndrome do Túnel Carpal , Humanos , Feminino , Gravidez , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/terapia , Resultado do Tratamento , Nervo Mediano/diagnóstico por imagem , Ultrassonografia
4.
J Hand Surg Am ; 46(3): 250.e1-250.e5, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32698979

RESUMO

This case report presents an application of peripheral nerve stimulation to the median nerve to treat a patient with intractable pain due to a lipofibromatous hamartoma of the left upper extremity. Ultra high-frequency ultrasound was used to determine the boundaries of the hamartoma. The patient then underwent an ultrasound-guided implantation of 2 stimulator electrodes distal to the elbow along the median nerve with stimulation coverage achieved at 1.2 and 1.4 mA, respectively. After an uneventful procedure, the pain score immediately decreased from 9 out of 10 to less than 6 on a numeric rating scale. Two weeks after the procedure, the patient reported substantial pain relief, with an average pain level of 5 to 6 out of 10. Twelve months after implantation, the patient maintained significant pain relief, rating her average pain level as a 4 to 6 out of 10. Placement of a percutaneous peripheral nerve stimulator was safe and effective with no adverse events being reported at the 12-month follow-up.


Assuntos
Hamartoma , Dor Intratável , Estimulação Elétrica Nervosa Transcutânea , Feminino , Hamartoma/complicações , Hamartoma/diagnóstico por imagem , Humanos , Nervo Mediano/diagnóstico por imagem , Dor Intratável/terapia , Ultrassonografia de Intervenção
5.
J Comput Assist Tomogr ; 43(4): 539-546, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31268874

RESUMO

OBJECTIVE: The objective of this study was to investigate the changes in the blood oxygen level-dependent (BOLD) response in the ipsilateral primary somatosensory cortex (SI) and thalamus of patients with moyamoya disease (MMD) during sensory stimulation. METHODS: Sixty-four MMD patients, and 15 healthy volunteers were enrolled. Thirty-three MMD patients exhibited paroxysmal numbness or hypoesthesia in the unilateral limbs. Fifteen patients with acroparesthesia underwent unilateral encephaloduroarteriosynangiosis (EDAS). All volunteers underwent BOLD functional magnetic resonance imaging (BOLD-fMRI) under median nerve electrical stimulation (MNES). Blood oxygen level-dependent fMRI data were processed to obtain time-signal intensity curves in the activation areas of the bilateral SI and thalamus. Processed dynamic susceptibility contrast-enhanced magnetic resonance imaging data were used to measure the time to peak of the BOLD response in the regions of interest, including the bilateral SI, thalamus, and cerebellum. Changes in the time-signal intensity curve-related hemodynamic parameters in the ipsilateral SI and thalamus were examined between healthy controls, nonacroparesthesia patients, and asymptomatic and symptomatic sides of unilateral acroparesthesia patients during MNES. Changes in these parameters in MMD patients before and after EDAS were examined. RESULTS: Compared with healthy volunteers, 3 groups of MMD patients exhibited an increased peak of the positive BOLD response in the ipsilateral thalamus during MNES (0.65 ± 0.24 vs 0.79 ± 0.35, 0.94 ± 0.57, and 0.89 ± 0.50; P = 0.0335). The positive response peak in the ipsilateral SI markedly increased in MMD patients with acroparesthesia during MNES on the asymptomatic side (0.56 ± 0.37 vs 0.38 ± 0.27, P = 0.0243). The time to peak negative response in the ipsilateral SI was prolonged during MNES on the symptomatic side after EDAS (12.14 ± 8.90 seconds vs 18.86 ± 9.20 seconds, P = 0.0201). CONCLUSIONS: During sensory stimulation treatment, BOLD response changes occurred in the ipsilateral SI and thalamus of MMD patients. These changes enabled the contralateral hemisphere of the brain to better deal with sensory stimuli.


Assuntos
Estimulação Elétrica/métodos , Imageamento por Ressonância Magnética/métodos , Doença de Moyamoya/diagnóstico por imagem , Oxigênio/sangue , Córtex Somatossensorial , Tálamo , Adulto , Feminino , Humanos , Nervo Mediano/diagnóstico por imagem , Nervo Mediano/fisiologia , Plasticidade Neuronal , Córtex Somatossensorial/irrigação sanguínea , Córtex Somatossensorial/diagnóstico por imagem , Tálamo/irrigação sanguínea , Tálamo/diagnóstico por imagem
6.
J Manipulative Physiol Ther ; 42(5): 366-371, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31262581

RESUMO

OBJECTIVE: The aim of this study was to relate forearm anthropometric measures to ultrasound pronator teres depth to determine the necessary needle length to prevent median nerve (MN) injury during pronator teres dry needling. METHODS: We conducted a study employing a diagnostic accuracy prediction model (NCT03308279) at a Spanish university center. The study recruited 65 participants to predict the depth of the MN (measured with ultrasound) in the pronator teres using a decision tree algorithm to reduce the risk of MN puncture using 2 needle lengths (13 mm or 25 mm). The decision tree was developed by automatically selecting a cutoff for body mass index, forearm length and circumference, and pronator teres thickness. RESULTS: For forearm circumferences ≤27.5 cm, the predictive value for the 13-mm needle was 92%. For forearm circumferences >27.5 cm and forearm lengths ≤26.75 cm, the predictive value for the 25-mm needle was 100%. CONCLUSION: Based upon the findings of this study, we suggest that needle length should be selected according to forearm anthropometric measures to prevent MN injury during pronator teres dry needling.


Assuntos
Agulhamento Seco , Nervo Mediano/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Adulto , Algoritmos , Árvores de Decisões , Feminino , Antebraço/anatomia & histologia , Humanos , Doença Iatrogênica/prevenção & controle , Masculino , Traumatismos dos Nervos Periféricos/prevenção & controle , Estudos de Amostragem , Ultrassonografia
7.
Lymphat Res Biol ; 17(1): 78-86, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30358471

RESUMO

BACKGROUND: Multilayer bandaging used in complex decongestive therapy (CDT) may increase tissue pressure resulting in nerve entrapments. The aim of this study was to discover if median nerve damage is a consequence of CDT in patients with breast cancer-related lymphedema (BCRL). METHODS AND RESULTS: Eighty-two arms of 41 patients with BCRL were included. Mean age was 56.05 (8.16) years and all stages of lymphedema were equally included. Fifteen sessions of CDT was applied to all patients. The calculated volume of extremities, the quality of life (cancer adaptation of Ferrans-Powell), neuropathic pain (NP; Douleur Neuropathique 4), and disability (quick disabilities of arm, shoulder, and hand [Q-DASH]) tests were recorded before and after therapy. Skin and subcutaneous tissue thicknesses of volar and dorsal sides and median nerve cross-sectional area (CSA) at the level of carpal tunnel were measured using ultrasonography (US), before and after therapy. Carpal tunnel syndrome (CTS; 41.37%) and polyneuropathy (10.34%) were common findings confirmed by electromyography. Neuropathic pain profile was also found in 34.14% of patients. The arm volume of affected side, quality of life, and skin and subcutaneous tissue thicknesses were improved after therapy (p < 0.05). However, median nerve CSA, the NP, and Q-DASH scores were not changed after therapy. CONCLUSIONS: Although lymphedema is a painless condition, NP and CTS should not be ignored in patients with BCRL. US is an alternative, precise, and high technological method for evaluating treatment response. CDT is an effective and safe treatment according to volumetric calculations, US measurements of tissue thicknesses, and median nerve size.


Assuntos
Linfedema Relacionado a Câncer de Mama/terapia , Neoplasias da Mama/complicações , Carcinoma Ductal de Mama/complicações , Síndrome do Túnel Carpal/terapia , Bandagens Compressivas , Drenagem Linfática Manual/métodos , Neuralgia/prevenção & controle , Adulto , Idoso , Braço/diagnóstico por imagem , Braço/inervação , Braço/fisiopatologia , Braço/cirurgia , Linfedema Relacionado a Câncer de Mama/diagnóstico por imagem , Linfedema Relacionado a Câncer de Mama/etiologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/radioterapia , Carcinoma Ductal de Mama/cirurgia , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/etiologia , Eletromiografia , Exercício Físico , Feminino , Humanos , Nervo Mediano/diagnóstico por imagem , Nervo Mediano/fisiopatologia , Pessoa de Meia-Idade , Neuralgia/etiologia , Neuralgia/fisiopatologia , Estudos Prospectivos , Qualidade de Vida/psicologia , Higiene da Pele/métodos , Resultado do Tratamento , Ultrassonografia
8.
J Ultrasound Med ; 38(1): 113-122, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29892976

RESUMO

OBJECTIVES: To evaluate the efficacy of low-level laser therapy on median nerve stiffness by using strain elastography in carpal tunnel syndrome (CTS). METHODS: This study included 37 wrists of 34 patients with mild or moderate CTS between January 2016 and August 2016. The control group comprised 17 patients (18 wrists) with CTS who were treated with wrist splinting for 3 weeks. The low-level laser therapy group included 17 patients (19 wrists) with CTS who were treated with a combination of splinting and low-level laser therapy, which was applied 5 times per week for 3 weeks. Clinical assessment scales, including the Symptom Severity Scale (SSS) and Functional Status Score (FSS), were obtained from our database. The cross-sectional area by ultrasound and strain ratio by elastography were studied. The differences in the strain ratio, cross-sectional area, SSS, and FSS between pretreatment and posttreatment periods in the groups were compared by the paired-sample t test. The correlations between changes in the strain ratio and the cross-sectional area, SSS, and FSS were analyzed by Pearson correlation coefficients. RESULTS: The control group included 13 women and 4 men, and the therapy group included 14 women and 3 men. In the therapy group, the mean values of the strain ratio, cross-sectional area, SSS, and FSS decreased significantly after laser therapy (P < .001) in contrast to the control group. No significant correlation was observed between the decreasing degree of the strain ratio and the cross-sectional area, SSS, and FSS after laser therapy. CONCLUSIONS: The strain ratio and cross-sectional area of the median nerve decrease after low-level laser therapy. These changes may be related to the therapeutic effects of low-level laser therapy, such as nerve regeneration and improvement of the vascular supply.


Assuntos
Síndrome do Túnel Carpal/terapia , Técnicas de Imagem por Elasticidade/métodos , Terapia com Luz de Baixa Intensidade/métodos , Nervo Mediano/diagnóstico por imagem , Contenções , Adulto , Síndrome do Túnel Carpal/patologia , Síndrome do Túnel Carpal/radioterapia , Terapia Combinada/métodos , Feminino , Humanos , Masculino , Nervo Mediano/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia
10.
J Bodyw Mov Ther ; 22(2): 348-353, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29861232

RESUMO

OBJECTIVES: To use ultrasound imaging to show how the needles in dry needling applied in the carpal tunnel can reach the transverse carpal ligament, acting on it in the form of traction-stretching when the fascial winding technique is performed. The potential associated risks are also assessed. DESIGN: Validation study. PARTICIPANTS: Healthy volunteers (n = 18). METHODS: Four dry needling needles were applied to the carpal tunnel, only using anatomical references, according to the original approach known as "four-pole carpal dry needling", and manipulating the needles following the so-called fascial winding technique according to the authors, in the form of unidirectional rotation. An ultrasound recording of the distance reached was then performed, and compared with the mechanical action achieved on the transverse carpal ligament. RESULTS: 93.1% of the needles placed came into contact with the transverse carpal ligament with traction-stretching of the ligament observed when the needles were manipulated with the fascial winding technique in 80.6%. The mean distance from the tip of the needle to the median nerve was 3.75 mm, with CI95% [3.10, 4.41] and it was 7.78 mm with CI95% [6.64, 8.91] to the ulnar artery. Pain immediately after the technique concluded was of mild intensity, almost nil 10 min later, and non-existent after one week. CONCLUSION: Dry needling with fascial winding technique in the carpal tunnel using the four-pole carpal dry needling approach is valid for reaching and traction of the transverse carpal ligament, and may stretch it and relax it. It is also safe with regard to the median nerve and ulnar artery, with a very mild level of pain.


Assuntos
Ossos do Carpo/diagnóstico por imagem , Ligamentos/diagnóstico por imagem , Nervo Mediano/diagnóstico por imagem , Manipulações Musculoesqueléticas/métodos , Agulhas , Adulto , Idoso , Índice de Massa Corporal , Ossos do Carpo/anatomia & histologia , Fáscia , Feminino , Humanos , Ligamentos/anatomia & histologia , Masculino , Nervo Mediano/anatomia & histologia , Pessoa de Meia-Idade , Artéria Ulnar/anatomia & histologia , Artéria Ulnar/diagnóstico por imagem , Ultrassonografia
11.
Musculoskelet Sci Pract ; 36: 12-16, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29635191

RESUMO

INTRODUCTION: The carpal tunnel is a clinically important fibro-osseous conduit for the median nerve and associated tendons. It is mechanically dynamic, such that the dimensions of the tunnel and median nerve change with position, movement and application of externally applied force with mechanical devices. Therapeutic manual techniques that appear to move and change tunnel shape are part of clinical practice. The aim of this study was therefore to measure changes in dimensions of the carpal tunnel and median nerve with manual mobilization of the carpal bones. MATERIAL AND METHODS: An analytical descriptive study with 18 volunteer subjects and a total of 33 records was designed. Ultrasound measurements of the cross-sectional area (CSA), anteroposterior diameter (APD), transverse diameter (TD), perimeter, flattening ratio and circularity of the carpal tunnel and of the median nerve, were measured, both in the anatomical position of the wrist and during mobilization techniques of the carpal bones. RESULTS: During the mobilization technique, the tunnel (p = 0.003) CSA significantly increased. APD also increased significantly for the tunnel (<0.001) while TD decreased. The median nerve showed similar and significant (p < 0.001) changes than the tunnel. However, because several of the obtained differences where smaller than the SDD obtained in a previous study, these differences were considered as irrelevant. CONCLUSIONS: Manual mobilization of the carpal bones produced significant changes in the dimensions of the carpal tunnel.


Assuntos
Ossos do Carpo/diagnóstico por imagem , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/terapia , Nervo Mediano/diagnóstico por imagem , Manipulações Musculoesqueléticas/métodos , Tendões/diagnóstico por imagem , Punho/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Ultrassonografia , Adulto Jovem
12.
Muscle Nerve ; 58(2): 310-313, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29513382

RESUMO

INTRODUCTION: Magnet therapy has been proposed as a treatment for neurologic conditions. In this this trial we assessed the feasibility and efficacy of a magnet inserted into a wristband for carpal tunnel syndrome (CTS). METHODS: Twenty-two patients with mild to moderate CTS were randomized to wear a high-dose or low-dose "sham" magnetic wristband for 6 weeks. The primary outcome was the Symptom Severity Scale (SSS) of the Boston Carpal Tunnel Questionnaire. Secondary measures were nerve conduction studies (NCS), median nerve ultrasound, and compliance. RESULTS: Compliance for both groups was >90%. Improvements in the mean SSS, NCS, and median nerve ultrasound did not reach statistical significance. DISCUSSION: Magnet therapy via wristband is well-tolerated. Further investigations in larger populations are needed to determine efficacy. Muscle Nerve 58: 310-313, 2018.


Assuntos
Síndrome do Túnel Carpal/terapia , Imãs , Síndrome do Túnel Carpal/diagnóstico por imagem , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Nervo Mediano/diagnóstico por imagem , Pessoa de Meia-Idade , Condução Nervosa , Cooperação do Paciente , Resultado do Tratamento , Ultrassonografia
13.
Rheumatol Int ; 32(2): 409-15, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21120497

RESUMO

The objective of this study is to investigate the efficacy of low-level laser therapy (LLLT) in patients with carpal tunnel syndrome (CTS). Sixty patients with CTS were included in this placebo-controlled and double-blind study and randomly assigned to three treatment groups: active laser with a dosage of 1.2 J/per painful point, active laser with a dosage of 0.6 J/per painful point, and placebo groups. A total of 5 points across the median nerve trace were irradiated with Gal-Al-As diode laser. All groups were treated 5 times per week for 3 weeks. Clinical assessments included pain intensity, grip strength, symptom severity score (SSS), functional status score (FSS), nerve conduction studies, and cross-sectional area (CSA) of the median nerve as measured by ultrasonography. Compared to baseline, post-treatment VAS scores (group 1, P < 0.001; group 2, P < 0.001; group 3, P < 0.01), grip strength (P < 0.05), SSS scores (group 1, P < 0.001; group 2, P < 0.001; group 3, P < 0.01), and FSS scores (P < 0.05) improved significantly in all groups. Only sensorial nerve velocity measurements on the palmar region showed a significant improvement in both active laser groups (P < 0.01). There was no significant difference in any of the outcome measures among the groups. With the chosen laser type and dose regimen, the results suggested that LLLT was no more effective than placebo in CTS.


Assuntos
Síndrome do Túnel Carpal/fisiopatologia , Síndrome do Túnel Carpal/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Adulto , Idoso , Síndrome do Túnel Carpal/diagnóstico por imagem , Relação Dose-Resposta à Radiação , Método Duplo-Cego , Feminino , Humanos , Masculino , Nervo Mediano/diagnóstico por imagem , Nervo Mediano/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Ultrassonografia
14.
Acupunct Med ; 26(4): 231-3, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19098694

RESUMO

In an experiment on one of the authors, we used ultrasound to visualise an acupuncture needle completely perforating the median nerve at the acupuncture point PC6. During this procedure only a slight sensation occurred, and no pain. We conclude that, in individual cases, the median nerve might be perforated without causing pain or neurological problems.


Assuntos
Terapia por Acupuntura/instrumentação , Antebraço/inervação , Nervo Mediano/diagnóstico por imagem , Nervo Mediano/lesões , Agulhas/efeitos adversos , Pontos de Acupuntura , Terapia por Acupuntura/efeitos adversos , Terapia por Acupuntura/métodos , Adulto , Feminino , Antebraço/diagnóstico por imagem , Humanos , Dor/diagnóstico por imagem , Dor/etiologia , Medição da Dor , Qi , Sensação/fisiologia , Ultrassonografia
15.
Reg Anesth Pain Med ; 33(6): 558-65, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19258971

RESUMO

BACKGROUND AND OBJECTIVES: Peripheral nerve stimulation (PNS) may provide analgesia for neuropathic pain syndromes in that nerve distribution. PNS electrode placement using ultrasound (US) guidance for upper extremity pain syndromes has not been reported. Existing anchoring technology may allow permanent implantation without significant migration. METHODS: Three cadaver midhumeral fresh frozen upper extremity specimens were studied. US scanning was performed, targeting electrode placement at the radial, ulnar, and median nerves. Leads were anchored in the superficial fascia. The targeted nerves were exposed by careful dissection. Visual inspection for gross nerve damage, and electrode proximity to the nerve was performed. After confirmation of adequate lead placement, 2 extremities were sutured and placed in a continuous passive motion (CPM) machine for 21 hours to simulate activity. Each electrode was assessed for migration. RESULTS: Acceptable locations for US-guided electrode placement were: radial nerve approximately 10-14 cm superior to the lateral epicondyle; median nerve approximately 6 cm below the antecubital fossa; and ulnar nerve approximately 9 to 13 cm above the medial epicondyle. One electrode was placed at each site without difficulty. After careful exposure, visual inspection showed no gross nerve damage. Each electrode had at least 2 electrical contacts within 2 mm of the nerve sheath. At CPM termination, only the median nerve electrode on 1 cadaver extremity had migrated significantly. CONCLUSIONS: This new minimally invasive approach to lead placement requires further study to determine implantation criteria, optimal locations, anchoring techniques, and electrode design to define best clinical practice.


Assuntos
Nervo Mediano/diagnóstico por imagem , Neuralgia/terapia , Nervo Radial/diagnóstico por imagem , Estimulação Elétrica Nervosa Transcutânea/instrumentação , Nervo Ulnar/diagnóstico por imagem , Ultrassonografia de Intervenção , Extremidade Superior/inervação , Cadáver , Eletrodos , Estudos de Viabilidade , Humanos , Estimulação Elétrica Nervosa Transcutânea/métodos , Extremidade Superior/diagnóstico por imagem
16.
J Altern Complement Med ; 13(5): 585-91, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17604564

RESUMO

BACKGROUND: Pericard 6 (P6) is one of the most frequently used acupuncture points, especially in preventing nausea and vomiting. At this point, the median nerve is located very superficially. OBJECTIVES: To investigate the distance between the needle tip and the median nerve during acupuncture at P6, we conducted a prospective observational ultrasound (US) imaging study. We tested the hypothesis that de qi (a sensation that is typical of acupuncture needling) is evoked when the needle comes into contact with the epineural tissue and thereby prevents nerve penetration. SETTINGS/LOCATION: The outpatient pain clinic of the Medical University of Vienna, Austria. SUBJECTS: Fifty (50) patients receiving acupuncture treatment including P6 bilaterally. INTERVENTIONS: Patients were examined at both forearms using US (a 10-MHz linear transducer) after insertion of the needle at P6. OUTCOME MEASURES: The distance between the needle tip and the median nerve, the number of nerve contacts and nerve penetrations, as well as the number of successfully elicited de qi sensations were recorded. RESULTS: Complete data could be obtained from 97 cases. The mean distance from the needle tip to the nerve was 1.8 mm (standard deviation 2.2; range 0-11.3). Nerve contacts were recorded in 52 cases, in 14 of which the nerve was penetrated by the needle. De qi was elicited in 85 cases. We found no association between the number of nerve contacts and de qi. The 1-week follow-up showed no complications or neurologic problems. CONCLUSIONS: This is the first investigation demonstrating the relationship between acupuncture needle placement and adjacent neural structures using US technology. The rate of median nerve penetrations by the acupuncture needle at P6 was surprisingly high, but these seemed to carry no risk of neurologic sequelae. De qi at P6 does not depend on median nerve contact, nor does it prevent median nerve penetration.


Assuntos
Terapia por Acupuntura/instrumentação , Antebraço/diagnóstico por imagem , Antebraço/inervação , Nervo Mediano/diagnóstico por imagem , Agulhas , Pontos de Acupuntura , Terapia por Acupuntura/métodos , Adulto , Áustria , Feminino , Humanos , Masculino , Qi , Valores de Referência , Projetos de Pesquisa , Ultrassonografia
17.
J Radiol ; 71(10): 555-9, 1990 Oct.
Artigo em Francês | MEDLINE | ID: mdl-2280380

RESUMO

This experimental study presents a new method of neurography of the ulnar and median nerves. Subcutaneous injection of water soluble iodine contrast medium (Urotrast 75%-Krka Yugoslavia) in the vicinity of the nerve immediately followed by 12V D.C. electrostimulation resulted in proximal flow of contrast medium along the epineural space versus all other structures of the nerve trunk. On X-ray films epineural space appeared as two parallel linear shadows delineating a lucent stripe which comprises all other nerve structures. By means of this method nerve X-ray images of very high quality have been accomplished for significantly shorter time than required in other procedures. The method is harmless for the patient and easily applicable.


Assuntos
Nervo Mediano/diagnóstico por imagem , Nervo Ulnar/diagnóstico por imagem , Humanos , Métodos , Radiografia , Pesquisa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA