Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Neurosurg Pediatr ; 23(2): 187-197, 2018 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-30497135

RESUMO

OBJECTIVEEndoscope-assisted hemispherotomy (EH) has emerged as a good alternative option for hemispheric pathologies with drug-resistant epilepsy.METHODSThis was a prospective observational study. Parameters measured included primary outcome measures (frequency, severity of seizures) and secondary outcomes (cognition, behavior, and quality of life). Blood loss, operating time, complications, and hospital stay were also taken into account. A comparison was made between the open hemispherotomy (OH) and endoscopic techniques performed by the senior author.RESULTSOf 59 cases (42 males), 27 underwent OH (8 periinsular, the rest vertical) and 32 received EH. The mean age was 8.65 ± 5.41 years (EH: 8.6 ± 5.3 years; OH: 8.6 ± 5.7 years). Seizure frequency per day was 7 ± 5.9 (EH: 7.3 ± 4.6; OH: 15.0 ± 6.2). Duration of disease (years since first episode) was 3.92 ± 1.24 years (EH: 5.2 ± 4.3; OH: 5.8 ± 4.5 years). Number of antiepileptic drugs per patient was 3.9 ± 1.2 (EH: 4.2 ± 1.2; OH: 3.8 ± 0.98). Values for the foregoing variables are expressed as the mean ± SD. Pathologies included the following: postinfarct encephalomalacia in 19 (EH: 11); Rasmussen's syndrome in 14 (EH: 7); hemimegalencephaly in 12 (EH: 7); hemispheric cortical dysplasia in 7 (EH: 4); postencephalitis sequelae in 6 (EH: 2); and Sturge-Weber syndrome in 1 (EH: 1). The mean follow-up was 40.16 ± 17.3 months. Thirty-nine of 49 (79.6%) had favorable outcomes (International League Against Epilepsy class I and II): in EH the total was 19/23 (82.6%) and in OH it was 20/26 (76.9%). There was no difference in the primary outcome between EH and OH (p = 0.15). Significant improvement was seen in the behavioral/quality of life performance, but not in IQ scores in both EH and OH (p < 0.01, no intergroup difference). Blood loss (p = 0.02) and hospital stay (p = 0.049) were less in EH.CONCLUSIONSEH was as effective as the open procedure in terms of primary and secondary outcomes. It also resulted in less blood loss and a shorter postoperative hospital stay.


Assuntos
Corpo Caloso/cirurgia , Epilepsia Resistente a Medicamentos/cirurgia , Hemisferectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Adolescente , Adulto , Perda Sanguínea Cirúrgica , Criança , Pré-Escolar , Cognição , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Feminino , Seguimentos , Hemisferectomia/efeitos adversos , Humanos , Lactente , Tempo de Internação , Imageamento por Ressonância Magnética , Masculino , Neuroendoscópios , Fotografação , Estudos Prospectivos , Qualidade de Vida , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
2.
Acta Neurochir (Wien) ; 160(2): 241-248, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29192373

RESUMO

BACKGROUND: The first choice to treat acute subdural hematoma (SDH) is a large craniotomy under general anesthesia. However, increasing age or comorbid burden of the patients may render invasive treatment strategy inappropriate. These medically frail patients with SDH may benefit from a combination of small craniotomy and endoscopic hematoma removal, which is less invasive and even available under local anesthesia. Although hematoma evacuation with a rigid endoscope for acute or subacute SDHs has been reported in the literature, use of a flexible endoscope may have distinct advantages. In this article, we attempted to clarify the utility of small craniotomy evacuation with a flexible endoscope for acute and subacute SDH in the elderly patients. METHOD: Between November 2013 and September 2016, a total of 17 patients with acute SDH (15 patients), subacute SDH (1 patient), or acute aggravation of chronic SDH (1 patient) underwent hematoma evacuation with a flexible endoscope at our hospital and were enrolled in this retrospective study. Either under local or general anesthesia, the SDH was removed with a flexible suction tube with the aid of the flexible endoscope through the small craniotomy (3 × 4 cm). Hematoma evacuation rate, improvement of clinical symptoms, and procedure-related complications were evaluated. RESULTS: Hematoma evacuation rate was satisfactory, and statistically significant clinical improvement was observed in postoperative Glasgow Coma Scale in all cases compared to the preoperative assessment. No procedure-related hemorrhagic complications were observed. CONCLUSIONS: The results reported here suggest that small craniotomy evacuation with a flexible endoscope is a safe, effective, and minimally invasive treatment for acute and subacute SDH in selected cases.


Assuntos
Craniotomia/métodos , Hematoma Subdural Agudo/cirurgia , Neuroendoscopia/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral , Anestesia Local , Feminino , Escala de Coma de Glasgow , Hematoma Subdural/cirurgia , Hematoma Subdural Crônico/cirurgia , Humanos , Masculino , Neuroendoscópios , Maleabilidade , Estudos Retrospectivos , Resultado do Tratamento
3.
Neurosci Res ; 119: 61-69, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28077288

RESUMO

In vivo Ca2+ imaging is a powerful method for the functional assessment of neural circuits. Although multi-photon excitation fluorescence microscopy has been widely used, observation of circuits in deep brain regions remains challenging. Recently, observing these deep regions has become possible via an endoscope consisting of an optical fiber bundle or gradient-index lens. We have designed a micro-endoscope system that enables simultaneous optical recording of fluorescence and electrical recording of neural activity. Using this system, we recorded auditory responses by simultaneously detecting changes in the fluorescence intensity of a Ca2+ indicator dye, multi-unit activities (MUA), and local field potentials (LFP) in the mouse's inferior colliculus (IC). Such simultaneous optical and electrical recordings enabled detailed comparison of electrically recorded phenomena (MUA and LFP) and optically recorded Ca2+ response. By systematically changing sound frequency and intensity, we determined the frequency tuning of the recording site. The best frequency shifted higher as the probe advanced more deeply, demonstrating that the system is capable of optically measuring the dorso-ventral organization of IC (i.e., tonotopicity). Thus, our new micro-endoscope system will be useful in the neurophysiological studies of a wide range of brain circuits, including those within the auditory system.


Assuntos
Percepção Auditiva/fisiologia , Mapeamento Encefálico/instrumentação , Colículos Inferiores/citologia , Colículos Inferiores/fisiologia , Vias Neurais/fisiologia , Neuroendoscópios , Neuroendoscopia/instrumentação , Estimulação Acústica , Potenciais de Ação/fisiologia , Animais , Mapeamento Encefálico/métodos , Cálcio/metabolismo , Indicadores e Reagentes/metabolismo , Colículos Inferiores/metabolismo , Camundongos , Microscopia de Fluorescência por Excitação Multifotônica
4.
Neurosurg Focus ; 41(3): E13, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27581309

RESUMO

OBJECTIVE Rigid endoscopes enable minimally invasive access to the ventricular system; however, the operative field is limited to the instrument tip, necessitating rotation of the entire instrument and causing consequent tissue compression while reaching around corners. Although flexible endoscopes offer tip steerability to address this limitation, they are more difficult to control and provide fewer and smaller working channels. A middle ground between these instruments-a rigid endoscope that possesses multiple instrument ports (for example, one at the tip and one on the side)-is proposed in this article, and a prototype device is evaluated in the context of a third ventricular colloid cyst resection combined with septostomy. METHODS A prototype neuroendoscope was designed and fabricated to include 2 optical ports, one located at the instrument tip and one located laterally. Each optical port includes its own complementary metal-oxide semiconductor (CMOS) chip camera, light-emitting diode (LED) illumination, and working channels. The tip port incorporates a clear silicone optical window that provides 2 additional features. First, for enhanced safety during tool insertion, instruments can be initially seen inside the window before they extend from the scope tip. Second, the compliant tip can be pressed against tissue to enable visualization even in a blood-filled field. These capabilities were tested in fresh porcine brains. The image quality of the multiport endoscope was evaluated using test targets positioned at clinically relevant distances from each imaging port, comparing it with those of clinical rigid and flexible neuroendoscopes. Human cadaver testing was used to demonstrate third ventricular colloid cyst phantom resection through the tip port and a septostomy performed through the lateral port. To extend its utility in the treatment of periventricular tumors using MR-guided laser therapy, the device was designed to be MR compatible. Its functionality and compatibility inside a 3-T clinical scanner were also tested in a brain from a freshly euthanized female pig. RESULTS Testing in porcine brains confirmed the multiport endoscope's ability to visualize tissue in a blood-filled field and to operate inside a 3-T MRI scanner. Cadaver testing confirmed the device's utility in operating through both of its ports and performing combined third ventricular colloid cyst resection and septostomy with an endoscope rotation of less than 5°. CONCLUSIONS The proposed design provides freedom in selecting both the number and orientation of imaging and instrument ports, which can be customized for each ventricular pathological entity. The lightweight, easily manipulated device can provide added steerability while reducing the potential for the serious brain distortion that happens with rigid endoscope navigation. This capability would be particularly valuable in treating hydrocephalus, both primary and secondary (due to tumors, cysts, and so forth). Magnetic resonance compatibility can aid in endoscope-assisted ventricular aqueductal plasty and stenting, the management of multiloculated complex hydrocephalus, and postinflammatory hydrocephalus in which scarring obscures the ventricular anatomy.


Assuntos
Desenho de Equipamento/normas , Imageamento por Ressonância Magnética/normas , Neuroendoscópios/normas , Neuroendoscopia/normas , Maleabilidade , Animais , Desenho de Equipamento/métodos , Feminino , Humanos , Neuroendoscopia/instrumentação , Neuroendoscopia/métodos , Suínos
6.
J Neurol Surg A Cent Eur Neurosurg ; 75(3): 207-16, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23939681

RESUMO

BACKGROUND: Recently, the authors demonstrated the technical feasibility of a transventricular translaminar terminalis ventriculostomy with a rigid endoscope. A major problem with this technique remains the contusion of the fornix at the foramen of Monro. Here, the authors evaluated alternative approaches and techniques, including the use of a flexible endoscope. MATERIAL AND METHODS: Feasibility of two approaches-anterior and posterior of the coronal suture-was evaluated on magnetic resonance images and in cadaveric brains. Two different trajectories were selected. Lamina terminalis (LT) fenestration was performed with a rigid and a flexible endoscope using two approaches in 10 fixed cadaver brains. RESULTS: Using the posterior approach 2 cm behind the coronal suture with the two endoscopes caused moderate to severe damage to foramen and fornix. Using the standard approach (Kocher point) with the flexible endoscope avoided damage of these structures. After completion of the anatomical investigation, the authors successfully performed a transventricular fenestration of the LT with the flexible endoscope in one clinical case. CONCLUSION: Rigid scopes provide brilliant optics and safe manipulation with the instruments. However, with the rigid scope, a transventricular opening of the LT is only possible with acceptance of structural damage to the foramen of Monro and the fornix. In contrast, opening of the LT via a transventricular route with preservation of the anatomical structures can be achieved with a flexible steerable endoscope even via a standard burr hole. Thus, if a standard third ventriculostomy is not feasible, endoscopic opening of the LT might represent an alternative, particularly with a flexible scope in experienced hands.


Assuntos
Ventrículos Cerebrais/cirurgia , Hipotálamo/cirurgia , Neuroendoscópios/normas , Neuroendoscopia/métodos , Ventriculostomia/métodos , Adulto , Humanos , Imageamento por Ressonância Magnética , Masculino , Neuroendoscopia/instrumentação , Neuroendoscopia/normas , Ventriculostomia/instrumentação , Ventriculostomia/normas
7.
J Neurosurg ; 102(6): 1142-6, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16028777

RESUMO

The authors present two cases in which enlarged Virchow-Robin spaces were located in the basal ganglia and the thalamomesencephalic region. The incidence of such huge cystic lesions is extremely rare. The expanding nature of these lesions, demonstrated by the patients' progressive symptoms due to compression of the adjacent brain parenchyma and obstructive hydrocephalus, mimicked that of brain tumors. The two patients were successfully treated by neuroendoscopic cystocisternostomy or ventriculocystostomy. To the authors' knowledge there have been only two published reports on expanding Virchow-Robin spaces that produced a compressive effect or consequent hydrocephalus and were directly fenestrated using neuroendoscopic techniques. Neuroendoscopy appears to offer an effective surgical option in the treatment of symptomatic Virchow-Robin spaces.


Assuntos
Neoplasias Encefálicas/diagnóstico , Transtornos Cerebrovasculares/diagnóstico , Transtornos Cerebrovasculares/cirurgia , Hidrocefalia/diagnóstico , Hidrocefalia/cirurgia , Gânglios da Base/patologia , Diagnóstico Diferencial , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neuroendoscópios , Procedimentos Neurocirúrgicos , Tálamo/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA