Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Soc Esp Oftalmol (Engl Ed) ; 94(8): 413-416, 2019 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31053369

RESUMO

Three cases of patients with decreased visual acuity and papillitis at onset with subsequent macular star development after a few weeks are presented. Complementary tests were unremarkable in all included patients. Based on this clinical context, they were diagnosed with Leber's idiopathic stellate neuroretinitis, were treated with corticosteroids, as well as with antibiotics in 2cases. All patients showed favourable outcomes, although signs of papillary atrophy were observed in the affected eyes. Leber's idiopathic stellate neuroretinitis diagnosis can be challenging due to the wide spectrum of conditions that have to be ruled out. In addition, macular star may appear later on, which should not exclude its diagnosis. Use of antibiotics and/or corticosteroids is controversial considering its benign nature, but should be considered in selected severe cases. Moreover, the routine use of complementary tests should be carefully evaluated, mainly those that can be aggressive and/or expensive, which should be rationally used.


Assuntos
Papiledema/diagnóstico por imagem , Retinite/diagnóstico por imagem , Adolescente , Corticosteroides/uso terapêutico , Adulto , Antibacterianos/uso terapêutico , Doxiciclina/uso terapêutico , Feminino , Humanos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Masculino , Papiledema/complicações , Papiledema/tratamento farmacológico , Retinite/complicações , Retinite/tratamento farmacológico , Tomografia de Coerência Óptica , Transtornos da Visão/etiologia , Acuidade Visual
2.
Invest Ophthalmol Vis Sci ; 41(10): 2960-6, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10967051

RESUMO

PURPOSE: To determine the accuracy and reproducibility of ultrasonographic (US) readings of optic disc elevations in patients with papilledema compared with confocal scanning laser ophthalmoscope (CSLO) measurements. METHODS: One randomly selected eye of 22 patients with idiopathic intracranial hypertension (IIH) and a variable degree of optic disc swelling underwent five and three repeated measurements of disc height using high-resolution ultrasonography (Biovision unit; Quantel Medical, Clermont-Ferrand, France) and CSLO (Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany), respectively. The same procedure was assessed in 14 subjects with variable degrees of physiologic optic disc cupping. US and HRT measurements from each group were individually compared with each other to estimate the accuracy of US readings in both disc conditions in comparison with HRT data. RESULTS: Ultrasonographic readings were positively correlated with HRT measurements in both swollen (r = 0.62, P: = 0.002) and excavated disc (r = 0.84, P: < 0.0002). The 95% limits of agreement between the instruments were 0.24 +/- 0.59 mm (mean +/- 2 SD) and 0. 05 +/- 0.3 mm for swelling and cupping measurements, respectively. The coefficient of variation was 7.63% and 1.8% for swelling and 7. 93% and 5.91% for cupping, with US and HRT, respectively. CONCLUSIONS: The results indicate that US and CSLO readings are correlated i: both disc swelling and cupping conditions, but to a different extent because of a significant discrepancy in papilledema. US assessment can be considered highly reproducible. Combined US and HRT optic disc analysis may be recommended in papilledema evaluation as long as a better correlation can be demonstrated in further studies.


Assuntos
Hipertensão Intracraniana/diagnóstico por imagem , Oftalmoscopia/métodos , Disco Óptico/diagnóstico por imagem , Papiledema/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Hipertensão Intracraniana/complicações , Masculino , Pessoa de Meia-Idade , Disco Óptico/patologia , Papiledema/etiologia , Reprodutibilidade dos Testes , Tomografia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA