Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Revista
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Retina ; 31(4): 686-91, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21386767

RESUMO

PURPOSE: To compare the anatomical and functional outcomes of 23-gauge pars plana vitrectomy (PPV) with Densiron-68 tamponade and 360° endolaser versus 20-gauge PPV with encircling scleral buckling (ESB) and an SF6 gas tamponade for the repair of primary pseudophakic retinal detachment with inferior retinal breaks. METHODS: Prospective, randomized, comparative, interventional study. Eighty-two eyes of 82 consecutive patients were randomly assigned to 1 of the 2 treatment groups: 23-gauge PPV/Densiron-68 (44 eyes, 54%) or 20-gauge PPV/ESB/SF6 (20%) (38 eyes, 46%). The inclusion criterion was the presence of primary pseudophakic retinal detachment with at least 1 retinal break between the 4- and 8-o'clock positions. The study protocol involved a minimum of 7 visits: baseline, day of surgery, 1 week, and 1, 3, 6, and 9 months postoperation. Densiron-68 removal was performed within 12 weeks of the initial surgery. Two surgical procedures were required in the Densiron group to remove the oil. RESULTS: After the primary procedure, the retina was reattached in 90% (40 of 44) of cases in the 23-gauge PPV/Densiron group and in 92% (35 of 38) of cases in the 20-gauge PPV/ESB/SF6 group (P = 0.2, Fisher's exact test). After resolution of redetachments, final anatomical success rate rose to 97% (43 of 44) in the 23-gauge PPV/Densiron group and 94% (36 of 38) in the 20-gauge PPV/SB/SF6 group (P = 0.32, Fisher's exact test). Mean final best-corrected visual acuity (logarithm of the minimum angle of resolution) was 0.40 in the 23-gauge PPV/Densiron group and 0.48 in the 20-gauge PPV/ESB/SF6 group (P = 0.31, t-test). Operative time was significantly less in the 23-gauge PPV/Densiron group (P = 0.002, t-test). No statistically significant difference in the complication rate between the two groups was recorded. CONCLUSION: Twenty-three-gauge PPV combined with Densiron-68 and 360° endolaser and 20-gauge PPV combined with ESB/SF6 seemed to have similar efficacy in the repair of primary pseudophakic retinal detachment. Supplementary scleral buckling can be avoided using a Densiron-68 tamponade for retinal detachment with inferior retinal breaks.


Assuntos
Fotocoagulação a Laser/métodos , Descolamento Retiniano/terapia , Perfurações Retinianas/terapia , Recurvamento da Esclera/métodos , Óleos de Silicone/administração & dosagem , Hexafluoreto de Enxofre/administração & dosagem , Vitrectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Tamponamento Interno/métodos , Feminino , Humanos , Masculino , Microcirurgia/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Pseudofacia/fisiopatologia , Pseudofacia/terapia , Retina/fisiopatologia , Descolamento Retiniano/fisiopatologia , Perfurações Retinianas/fisiopatologia , Resultado do Tratamento , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA