1.
Med Phys ; 51(6): 4489-4503, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38432192

RESUMO

BACKGROUND: The increasing use of complex and high dose-rate treatments in radiation therapy necessitates advanced detectors to provide accurate dosimetry. Rather than relying on pre-treatment quality assurance (QA) measurements alone, many countries are now mandating the use of in vivo dosimetry, whereby a dosimeter is placed on the surface of the patient during treatment. Ideally, in vivo detectors should be flexible to conform to a patient's irregular surfaces. PURPOSE: This study aims to characterize a novel hydrogenated amorphous silicon (a-Si:H) radiation detector for the dosimetry of therapeutic x-ray beams. The detectors are flexible as they are fabricated directly on a flexible polyimide (Kapton) substrate. METHODS: The potential of this technology for application as a real-time flexible detector is investigated through a combined dosimetric and flexibility study. Measurements of fundamental dosimetric quantities were obtained including output factor (OF), dose rate dependence (DPP), energy dependence, percentage depth dose (PDD), and angular dependence. The response of the a-Si:H detectors investigated in this study are benchmarked directly against commercially available ionization chambers and solid-state diodes currently employed for QA practices. RESULTS: The a-Si:H detectors exhibit remarkable dose linearities in the direct detection of kV and MV therapeutic x-rays, with calibrated sensitivities ranging from (0.580 ± 0.002) pC/cGy to (19.36 ± 0.10) pC/cGy as a function of detector thickness, area, and applied bias. Regarding dosimetry, the a-Si:H detectors accurately obtained OF measurements that parallel commercially available detector solutions. The PDD response closely matched the expected profile as predicted via Geant4 simulations, a PTW Farmer ionization chamber and a PTW ROOS chamber. The most significant variation in the PDD performance was 5.67%, observed at a depth of 3 mm for detectors operated unbiased. With an external bias, the discrepancy in PDD response from reference data was confined to ± 2.92% for all depths (surface to 250 mm) in water-equivalent plastic. Very little angular dependence is displayed between irradiations at angles of 0° and 180°, with the most significant variation being a 7.71% decrease in collected charge at a 110° relative angle of incidence. Energy dependence and dose per pulse dependence are also reported, with results in agreement with the literature. Most notably, the flexibility of a-Si:H detectors was quantified for sample bending up to a radius of curvature of 7.98 mm, where the recorded photosensitivity degraded by (-4.9 ± 0.6)% of the initial device response when flat. It is essential to mention that this small bending radius is unlikely during in vivo patient dosimetry. In a more realistic scenario, with a bending radius of 15-20 mm, the variation in detector response remained within ± 4%. After substantial bending, the detector's photosensitivity when returned to a flat condition was (99.1 ± 0.5)% of the original response. CONCLUSIONS: This work successfully characterizes a flexible detector based on thin-film a-Si:H deposited on a Kapton substrate for applications in therapeutic x-ray dosimetry. The detectors exhibit dosimetric performances that parallel commercially available dosimeters, while also demonstrating excellent flexibility results.


Assuntos
Radiometria , Silício , Radiometria/instrumentação , Hidrogênio , Dosimetria in Vivo , Terapia por Raios X/instrumentação , Humanos
2.
Phys Med Biol ; 69(9)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38530300

RESUMO

Objective.The successful implementation of FLASH radiotherapy in clinical settings, with typical dose rates >40 Gy s-1, requires accurate real-time dosimetry.Approach.Silicon carbide (SiC) p-n diode dosimeters designed for the stringent requirements of FLASH radiotherapy have been fabricated and characterized in an ultra-high pulse dose rate electron beam. The circular SiC PiN diodes were fabricated at IMB-CNM (CSIC) in 3µm epitaxial 4H-SiC. Their characterization was performed in PTB's ultra-high pulse dose rate reference electron beam. The SiC diode was operated without external bias voltage. The linearity of the diode response was investigated up to doses per pulse (DPP) of 11 Gy and pulse durations ranging from 3 to 0.5µs. Percentage depth dose measurements were performed in ultra-high dose per pulse conditions. The effect of the total accumulated dose of 20 MeV electrons in the SiC diode sensitivity was evaluated. The temperature dependence of the response of the SiC diode was measured in the range 19 °C-38 °C. The temporal response of the diode was compared to the time-resolved beam current during each electron beam pulse. A diamond prototype detector (flashDiamond) and Alanine measurements were used for reference dosimetry.Main results.The SiC diode response was independent both of DPP and of pulse dose rate up to at least 11 Gy per pulse and 4 MGy s-1, respectively, with tolerable deviation for relative dosimetry (<3%). When measuring the percentage depth dose under ultra-high dose rate conditions, the SiC diode performed comparably well to the reference flashDiamond. The sensitivity reduction after 100 kGy accumulated dose was <2%. The SiC diode was able to follow the temporal structure of the 20 MeV electron beam even for irregular pulse estructures. The measured temperature coefficient was (-0.079 ± 0.005)%/°C.Significance.The results of this study demonstrate for the first time the suitability of silicon carbide diodes for relative dosimetry in ultra-high dose rate pulsed electron beams up to a DPP of 11 Gy per pulse.


Assuntos
Compostos Inorgânicos de Carbono , Dosímetros de Radiação , Radiometria , Radiometria/métodos , Compostos de Silício , Elétrons
3.
Lasers Med Sci ; 39(1): 76, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38386189

RESUMO

This research aims to examine the influence of human skull bone thickness and density on light penetration in PBM therapy across different wavelengths, focusing on how these bone characteristics affect the absorption of therapeutic light. Analyses explored the effect of skull bone density and thickness on light penetration in PBM, specifically using Low-Level Laser Therapy (LLLT) for efficacy prediction. Measurements of bone thickness and density were taken using precise tools. This approach emphasizes LLLT's significance in enhancing PBM outcomes by assessing how bone characteristics influence light penetration. The study revealed no significant correlation between skull bone density and thickness and light penetration capability in photobiomodulation (PBM) therapy, challenging initial expectations. Wavelengths of 405 nm and 665 nm showed stronger correlations with bone density, suggesting a significant yet weak impact. Conversely, wavelengths of 532 nm, 785 nm, 810 nm, 830 nm, 980 nm, and 1064 nm showed low correlations, indicating minimal impact from bone density variations. However, data variability (R2 < 0.4) suggests that neither density nor thickness robustly predicts light power traversing the bone, indicating penetration capability might be more influenced by bone thickness at certain wavelengths. The study finds that the effectiveness of photobiomodulation (PBM) therapy with bone isn't just based on bone density and thickness but involves a complex interplay of factors. These include the bone's chemical and mineral composition, light's wavelength and energy dose, treatment duration and frequency, and the precise location where light is applied on the skull.


Assuntos
Terapia com Luz de Baixa Intensidade , Humanos , Densidade Óssea , Crânio , Cabeça , Radiometria
4.
Radiother Oncol ; 194: 110177, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38378075

RESUMO

PURPOSE: Clinical translation of FLASH-radiotherapy (RT) to deep-seated tumours is still a technological challenge. One proposed solution consists of using ultra-high dose rate transmission proton (TP) beams of about 200-250 MeV to irradiate the tumour with the flat entrance of the proton depth-dose profile. This work evaluates the dosimetric performance of very high-energy electron (VHEE)-based RT (50-250 MeV) as a potential alternative to TP-based RT for the clinical transfer of the FLASH effect. METHODS: Basic physics characteristics of VHEE and TP beams were compared utilizing Monte Carlo simulations in water. A VHEE-enabled research treatment planning system was used to evaluate the plan quality achievable with VHEE beams of different energies, compared to 250 MeV TP beams for a glioblastoma, an oesophagus, and a prostate cancer case. RESULTS: Like TP, VHEE above 100 MeV can treat targets with roughly flat (within ± 20 %) depth-dose distributions. The achievable dosimetric target conformity and adjacent organs-at-risk (OAR) sparing is consequently driven for both modalities by their lateral beam penumbrae. Electron beams of 400[500] MeV match the penumbra of 200[250] MeV TP beams and penumbra is increased for lower electron energies. For the investigated patient cases, VHEE plans with energies of 150 MeV and above achieved a dosimetric plan quality comparable to that of 250 MeV TP plans. For the glioblastoma and the oesophagus case, although having a decreased conformity, even 100 MeV VHEE plans provided a similar target coverage and OAR sparing compared to TP. CONCLUSIONS: VHEE-based FLASH-RT using sufficiently high beam energies may provide a lighter-particle alternative to TP-based FLASH-RT with comparable dosimetric plan quality.


Assuntos
Elétrons , Método de Monte Carlo , Neoplasias da Próstata , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Elétrons/uso terapêutico , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/radioterapia , Masculino , Neoplasias Esofágicas/radioterapia , Glioblastoma/radioterapia , Radioterapia de Alta Energia/métodos , Órgãos em Risco/efeitos da radiação , Radiometria/métodos
5.
Radiat Environ Biophys ; 63(1): 81-95, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38217567

RESUMO

The United States Transuranium and Uranium Registries (USTUR) is a unique resource of data and materials for studying biokinetics of uranium in the human body. In this study, bioassay data and post-mortem organ activities from a female whole-body USTUR donor who was exposed to highly enriched uranium were analyzed using the IMBA Professional Plus® software to derive the best estimate of the total intake. The resulting radiation doses delivered to this individual's whole body and major target organs were calculated from estimated intake based on case-specific dose coefficients derived using the AIDE® software. Both intake and dose calculations were carried out using the biokinetic and dosimetric models recommended by the International Commission on Radiological Protection (ICRP) in its Occupational Intakes of Radionuclides publication series. Different exposure scenarios including chronic and acute inhalation intakes were tested. A combination of a chronic inhalation intake and two acute inhalation intakes appears to best describe the bioassay data. To fit this female individual's autopsy data, the transfer rate from the liver to the blood was increased by a factor of 8 and the transfer rate from the kidneys to the blood was decreased by a factor of 2.2. This resulted in the best fit to all data (p = 0.519). The total intake was estimated to be 44.1 kBq, and the committed effective dose was 211 mSv with 96.8% contributed by 234U. 96.6% of the committed effective dose was contributed by the lungs. The remaining 3.4% of the committed effective dose was contributed by all systemic tissues and organs with the highest contribution (0.40%) from the red bone marrow. It is concluded that the current ICRP models, with the adjustment for smoking status, adequately describe uranium biokinetics for this individual except retention in the liver and kidneys. However, this study was based on a single case and may not be sufficient to identify any apparent sex-specific differences in uranium biokinetics.


Assuntos
Exposição Ocupacional , Urânio , Masculino , Humanos , Feminino , Seguimentos , Radiometria , Radioisótopos , Software , Exposição Ocupacional/análise , Doses de Radiação
6.
Med Phys ; 51(2): 1421-1432, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38207016

RESUMO

BACKGROUND: The recent rediscovery of the FLASH effect, a normal tissue sparing phenomenon observed in ultra-high dose rate (UHDR) irradiations, has instigated a surge of research endeavors aiming to close the gap between experimental observation and clinical treatment. However, the dependences of the FLASH effect and its underpinning mechanisms on beam parameters are not well known, and large-scale in vivo studies using murine models of human cancer are needed for these investigations. PURPOSE: To commission a high-throughput, variable dose rate platform providing uniform electron fields (≥15 cm diameter) at conventional (CONV) and UHDRs for in vivo investigations of the FLASH effect and its dependences on pulsed electron beam parameters. METHODS: A murine whole-thoracic lung irradiation (WTLI) platform was constructed using a 1.3 cm thick Cerrobend collimator forming a 15 × 1.6 cm2 slit. Control of dose and dose rate were realized by adjusting the number of monitor units and couch vertical position, respectively. Achievable doses and dose rates were investigated using Gafchromic EBT-XD film at 1 cm depth in solid water and lung-density phantoms. Percent depth dose (PDD) and dose profiles at CONV and various UHDRs were also measured at depths from 0 to 2 cm. A radiation survey was performed to assess radioactivation of the Cerrobend collimator by the UHDR electron beam in comparison to a precision-machined copper alternative. RESULTS: This platform allows for the simultaneous thoracic irradiation of at least three mice. A linear relationship between dose and number of monitor units at a given UHDR was established to guide the selection of dose, and an inverse-square relationship between dose rate and source distance was established to guide the selection of dose rate between 20 and 120 Gy·s-1 . At depths of 0.5 to 1.5 cm, the depth range relevant to murine lung irradiation, measured PDDs varied within ±1.5%. Similar lateral dose profiles were observed at CONV and UHDRs with the dose penumbrae widening from 0.3 mm at 0 cm depth to 5.1 mm at 2.0 cm. The presence of lung-density plastic slabs had minimal effect on dose distributions as compared to measurements made with only solid water slabs. Instantaneous dose rate measurements of the activated copper collimator were up to two orders of magnitude higher than that of the Cerrobend collimator. CONCLUSIONS: A high-throughput, variable dose rate platform has been developed and commissioned for murine WTLI electron FLASH radiotherapy. The wide field of our UHDR-enabled linac allows for the simultaneous WTLI of at least three mice, and for the average dose rate to be modified by changing the source distance, without affecting dose distribution. The platform exhibits uniform, and comparable dose distributions at CONV and UHDRs up to 120 Gy·s-1 , owing to matched and flattened 16 MeV CONV and UHDR electron beams. Considering radioactivation and exposure to staff, Cerrobend collimators are recommended above copper alternatives for electron FLASH research. This platform enables high-throughput animal irradiation, which is preferred for experiments using a large number of animals, which are required to effectively determine UHDR treatment efficacies.


Assuntos
Cobre , Elétrons , Humanos , Animais , Camundongos , Aceleradores de Partículas , Pulmão , Água , Dosagem Radioterapêutica , Radiometria
7.
Med Phys ; 51(1): 533-544, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37656015

RESUMO

BACKGROUND: Ion beam therapy allows for a substantial sparing of normal tissues and higher biological efficacy. Synthetic single crystal diamond is a very good material to produce high-spatial-resolution and highly radiation hard detectors for both dosimetry and microdosimetry in ion beam therapy. PURPOSE: The aim of this work is the design, fabrication and test of an integrated waterproof detector based on synthetic single crystal diamond able to simultaneously perform dosimetric and microdosimetric characterization of clinical ion beams. METHODS: The active elements of the integrated diamond device, that is, dosimeter and microdosimeter, were both realized in a Schottky diode configuration featured by different area, thickness, and shape by means of photolithography technologies for the selective growth of intrinsic and boron-doped CVD diamond. The cross-section of the sensitive volume of the dosimetric element is 4 mm2 and 1 µm-thick, while the microdosimetric one has an active cross-sectional area of 100 × 100 µm2 and a thickness of about 6.2 µm. The dosimetric and microdosimetric performance of the developed device was assessed at different depths in a water phantom at the MedAustron ion beam therapy facility using a monoenergetic uniformly scanned carbon ion beam of 284.7 MeV/u and proton beam of 148.7 MeV. The particle flux in the region of the microdosimeter was 6·107  cm2 /s for both irradiation fields. At each depth, dose and dose distributions in lineal energy were measured simultaneously and the dose mean lineal energy values were then calculated. Monte Carlo simulations were also carried out by using the GATE-Geant4 code to evaluate the relative dose, dose averaged linear energy transfer (LETd ), and microdosimetric spectra at various depths in water for the radiation fields used, by considering the contribution from the secondary particles generated in the ion interaction processes as well. RESULTS: Dosimetric and microdosimetric quantities were measured by the developed prototype with relatively low noise (∼2 keV/µm). A good agreement between the measured and simulated dose profiles was found, with discrepancies in the peak to plateau ratio of about 3% and 4% for proton and carbon ion beams respectively, showing a negligible LET dependence of the dosimetric element of the device. The microdosimetric spectra were validated with Monte Carlo simulations and a good agreement between the spectra shapes and positions was found. Dose mean lineal energy values were found to be in close agreement with those reported in the literature for clinical ion beams, showing a sharp increase along the Bragg curve, being also consistent with the calculated LETd for all depths within the experimental error of 10%. CONCLUSIONS: The experimental indicate that the proposed device can allow enhanced dosimetry in particle therapy centers, where the absorbed dose measurement is implemented by the microdosimetric characterization of the radiation field, thus providing complementary results. In addition, the proposed device allows for the reduction of the experimental uncertainties associated with detector positioning and could facilitate the partial overcoming of some drawbacks related to the low sensitivity of diamond microdosimeters to low LET radiation.


Assuntos
Diamante , Prótons , Diamante/química , Radiometria , Carbono/uso terapêutico , Íons , Método de Monte Carlo , Água
8.
Sci Rep ; 13(1): 20425, 2023 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-37993500

RESUMO

Photobiomodulation therapy (PBMT) is recommended for prevention and treatment of oral mucositis, a painful condition that occurs in cancer patients. Intraoral PBMT is limited to treating distal oral mucosa and oropharynx. Extraoral PBMT may provide a more efficient intervention. The goal of this study was to develop a clinically viable protocol for extraoral PBMT. Monte Carlo modeling was used to predict the distribution of 850 nm light for four treatment sites, using anatomical data obtained from MRI and optical properties from the literature. Simulated incident light power density was limited to 399 mW/cm2 to ensure treatment safety and to prevent tissue temperature increase. The results reveal that total tissue thickness determines fluence rate at the oral mucosa, whereas the thickness of individual tissue layers and melanin content are of minor importance. Due to anatomical differences, the fluence rate varied greatly among patients. Despite these variations, a universal protocol was established using a median treatment time methodology. The determined median treatment times required to deliver efficacious dose between 1 and 6 J/cm2 were within 15 min. The developed PBMT protocol can be further refined using the combination of pretreatment imaging and the Monte Carlo simulation approach implemented in this study.


Assuntos
Terapia com Luz de Baixa Intensidade , Neoplasias , Estomatite , Humanos , Método de Monte Carlo , Estomatite/etiologia , Estomatite/prevenção & controle , Estomatite/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Radiometria
9.
Appl Radiat Isot ; 201: 111014, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37688904

RESUMO

The use of radiotherapy in tumor treatment has become increasingly prominent and has emerged as one of the main tools for treating malignant tumors. Current radiation therapy for glioma employs 125I seeds for brachytherapy, which cannot be combined with radiotherapy and chemotherapy. To address this limitation, this paper proposes a dual-microcavity capsule structure that integrates radiotherapy and chemotherapy. The Monte Carlo simulation method is used to simulate the structure of the dual-microcavity capsule with a 125I liquid radioactive source. Based on the simulation results, two kinds of dual-microcavity capsule structures are optimized, and the optimized dual-microcavity capsule structure is obtained. Finally, the dosimetric parameters of the two optimized dual-microcavity capsule structures are analyzed and compared with those of other 125I seeds. The optimization tests show that the improved dual-capsule dual-microcavity structure is more effective than the single-capsule dual-microcavity structure. At an activity of 5 mCi, the average absorbed dose rate is 71.2 cGy/h in the center of the optimized dual-capsule dual-microcavity structure and 45.8 cGy/h in the center of the optimized single-capsule dual-microcavity structure. Although the radial dose function and anisotropy function exhibite variations from the data of other 125I seeds, they are generally similar. The absorbed dose rate decreases exponentially with increasing distance from the center of the capsule, which can reduce the damage to the surrounding tissues and organs while increasing the dose. The capsule structure has a better irradiation effect than conventional 125I seeds and can accomplish long-term, stable, low-dose continuous irradiation to form local high-dose radiation therapy for glioma.


Assuntos
Braquiterapia , Glioma , Humanos , Braquiterapia/métodos , Dosagem Radioterapêutica , Método de Monte Carlo , Radiometria/métodos , Glioma/radioterapia , Anisotropia
10.
Phys Med Biol ; 68(13)2023 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-37267990

RESUMO

Objective. Microbeam radiation therapy (MRT) is an alternative emerging radiotherapy treatment modality which has demonstrated effective radioresistant tumour control while sparing surrounding healthy tissue in preclinical trials. This apparent selectivity is achieved through MRT combining ultra-high dose rates with micron-scale spatial fractionation of the delivered x-ray treatment field. Quality assurance dosimetry for MRT must therefore overcome a significant challenge, as detectors require both a high dynamic range and a high spatial resolution to perform accurately.Approach. In this work, a series of radiation hard a-Si:H diodes, with different thicknesses and carrier selective contact configurations, have been characterised for x-ray dosimetry and real-time beam monitoring applications in extremely high flux beamlines utilised for MRT at the Australian Synchrotron.Results. These devices displayed superior radiation hardness under constant high dose-rate irradiations on the order of 6000 Gy s-1, with a variation in response of 10% over a delivered dose range of approximately 600 kGy. Dose linearity of each detector to x-rays with a peak energy of 117 keV is reported, with sensitivities ranging from (2.74 ± 0.02) nC/Gy to (4.96 ± 0.02) nC/Gy. For detectors with 0.8µm thick active a-Si:H layer, their operation in an edge-on orientation allows for the reconstruction of micron-size beam profiles (microbeams). The microbeams, with a nominal full-width-half-max of 50µm and a peak-to-peak separation of 400µm, were reconstructed with extreme accuracy. The full-width-half-max was observed as 55 ± 1µm. Evaluation of the peak-to-valley dose ratio and dose-rate dependence of the devices, as well as an x-ray induced charge (XBIC) map of a single pixel is also reported.Significance. These devices based on novel a-Si:H technology possess a unique combination of accurate dosimetric performance and radiation resistance, making them an ideal candidate for x-ray dosimetry in high dose-rate environments such as FLASH and MRT.


Assuntos
Silício , Síncrotrons , Raios X , Austrália , Radiometria/métodos
11.
Cytogenet Genome Res ; 163(3-4): 103-109, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37285811

RESUMO

Radiation-related normal tissue injury sustained during cancer radiotherapy or in a radiological or mass casualty nuclear incident is a major health concern. Reducing the risk and mitigating consequences of radiation injury could have a broad impact on cancer patients and citizens. Efforts to discover biomarkers that can determine radiation dose, predict tissue damage, and aid medical triage are underway. Exposure to ionizing radiation causes changes in gene, protein, and metabolite expression that needs to be understood to provide a holistic picture for treating acute and chronic radiation-induced toxicities. We present evidence that both RNA (mRNA, microRNA, long noncoding RNA) and metabolomic assays may provide useful biomarkers of radiation injury. RNA markers may provide information on early pathway alterations after radiation injury that can predict damage and implicate downstream targets for mitigation. In contrast, metabolomics is impacted by changes in epigenetics, genetics, and proteomics and can be considered a downstream marker that incorporates all these changes to provide an assessment of what is currently happening within an organ. We highlight research from the past 10 years to understand how biomarkers may be used to improve personalized medicine in cancer therapy and medical decision-making in mass casualty scenarios.


Assuntos
MicroRNAs , Neoplasias , Lesões por Radiação , Humanos , Lesões por Radiação/etiologia , Lesões por Radiação/genética , MicroRNAs/genética , Biomarcadores , Epigênese Genética , Neoplasias/genética , Neoplasias/radioterapia , Radiometria
12.
Med Phys ; 50(11): 7245-7251, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37334736

RESUMO

BACKGROUND: Hydrated electrons, which are short-lived products of radiolysis in water, increase the optical absorption of water, providing a pathway toward near-tissue-equivalent clinical radiation dosimeters. This has been demonstrated in high-dose-per-pulse radiochemistry research, but, owing to the weak absorption signal, its application in existing low-dose-per-pulse radiotherapy provided by clinical linear accelerators (linacs) has yet to be investigated. PURPOSE: The aims of this study were to measure the optical absorption associated with hydrated electrons produced by clinical linacs and to assess the suitability of the technique for radiotherapy (⩽ 1 cGy per pulse) applications. METHODS: 40 mW of 660-nm laser light was sent five passes through deionized water contained in a 10 × 4 × $\times 4\times$ 2 cm3 glass-walled cavity by using four broadband dielectric mirrors, two on each side of the cavity. The light was collected with a biased silicon photodetector. The water cavity was then irradiated by a Varian TrueBeam linac with both photon (10 MV FFF, 6 MV FFF, 6 MV) and electron beams (6 MeV) while monitoring the transmitted laser power for absorption transients. Radiochromic EBT3 film measurements were also performed for comparison. RESULTS: Examination of the absorbance profiles showed clear absorption changes in the water when radiation pulses were delivered. Both the amplitude and the decay time of the signal appeared consistent with the absorbed dose and the characteristics of the hydrated electrons. By using literature value for the hydrated electron radiation chemical yield (3.0±0.3), we inferred doses of 2.1±0.2 mGy (10 MV FFF), 1.3±0.1 mGy (6 MV FFF), 0.45±0.06 mGy (6 MV) for photons, and 0.47±0.05 mGy (6 MeV) for electrons, which differed from EBT3 film measurements by 0.6%, 0.8%, 10%, and 15.7%, respectively. The half-life of the hydrated electrons in the solution was ∼ 24 µ $\umu$ s. CONCLUSIONS: By measuring 660-nm laser light transmitted through a cm-scale, multi-pass water cavity, we observed absorption transients consistent with hydrated electrons generated by clinical linac radiation. The agreement between our inferred dose and EBT3 film measurements suggests this proof-of-concept system represents a viable pathway toward tissue-equivalent dosimeters for clinical radiotherapy applications.


Assuntos
Elétrons , Dosímetros de Radiação , Fótons/uso terapêutico , Imagens de Fantasmas , Aceleradores de Partículas , Água , Dosagem Radioterapêutica , Radiometria/métodos
13.
Phys Med Biol ; 68(15)2023 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-37336242

RESUMO

Objective.This work investigates the use of Al2O3:C and Al2O3:C,Mg optically stimulated luminescence (OSL) detectors to determine both the dose and the radiation quality in light ion beams. The radiation quality is here expressed through either the linear energy transfer (LET) or the closely related metricQeff, which depends on the particle's speed and effective charge. The derived LET andQeffvalues are applied to improve the dosimetry in light ion beams.Approach.OSL detectors were irradiated in mono-energetic1H-,4He-,12C-, and16O-ion beams. The OSL signal is associated with two emission bands that were separated using a pulsed stimulation technique and subjected to automatic corrections based on reference irradiations. Each emission band was investigated independently for dosimetry, and the ratio of the two emission intensities was parameterized as a function of fluence- and dose-averaged LET, as well asQeff. The determined radiation quality was subsequently applied to correct the dose for ionization quenching.Main results.For both materials, theQeffdeterminations in1H- and4He-ion beams are within 5 % of the Monte Carlo simulated values. Using the determined radiation quality metrics to correct the nonlinear (ionization quenched) detector response leads to doses within 2 % of the reference doses.Significance.Al2O3:C and Al2O3:C,Mg OSL detectors are applicable for dosimetry and radiation quality estimations in1H- and4He-ions. Only Al2O3:C,Mg shows promising results for dosimetry in12C-ions. Across both materials and the investigated ions, the estimatedQeffvalues were less sensitive to the ion types than the estimated LET values were. The reduced uncertainties suggest new possibilities for simultaneously estimating the physical and biological dose in particle therapy with OSL detectors.


Assuntos
Transferência Linear de Energia , Dosimetria por Luminescência Estimulada Opticamente , Óxido de Alumínio , Radiometria/métodos , Luminescência , Íons , Dosimetria Termoluminescente/métodos
14.
J Cancer Res Ther ; 19(Supplement): S0, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37147959

RESUMO

Aim: The aim of this study was to carried out the audit of radiotherapy centers practicing conformal radiotherapy techniques and demonstrate the suitability of this indigenous optically stimulated luminescence (OSL) disc dosimeters in beam quality audit and verification of patient-specific dosimetry in conventional and conformal treatments in radiotherapy. Materials and Methods: Dose audit in conventional and conformal (intensity-modulated radiotherapy and volumetric-modulated arc therapy) radiotherapy techniques was conducted using in-house developed Al2O3:C-based OSL disc dosimeter and commercially available Gafchromic EBT3 film in 6 MV (flat and unflat) photon and 6 and 15 MeV electron beams. OSL disc dosimeter and Gafchromic EBT3 film measured dose values were verified using the ionization chamber measurements. Results: Percentage variations of doses measured by OSL disc dosimeters and EBT3 Gafchromic film for conventional radiotherapy technique were in the range of 0.15%-4.6% and 0.40%-5.45%, respectively, with respect to the treatment planning system calculated dose values. For conformal radiotherapy techniques, the percentage variations of OSL disc and EBT3 film measured doses were in the range of 0.1%-4.9% and 0.3%-5.0%, respectively. Conclusion: The results of this study supported by statistical evidence provided the confidence that indigenously developed Al2O3:C-based OSL disc dosimeters are suitable for dose audit in conventional and advanced radiotherapy techniques.


Assuntos
Dosimetria por Luminescência Estimulada Opticamente , Dosímetros de Radiação , Humanos , Luminescência , Radiometria , Óxido de Alumínio
15.
Eur J Nucl Med Mol Imaging ; 50(7): 1861-1868, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37086275

RESUMO

Dosimetry can be a useful tool for personalization of molecular radiotherapy (MRT) procedures, enabling the continuous development of theranostic concepts. However, the additional resource requirements are often seen as a barrier to implementation. This guide discusses the requirements for dosimetry and demonstrates how a dosimetry regimen can be tailored to the available facilities of a centre. The aim is to help centres wishing to initiate a dosimetry service but may not have the experience or resources of some of the more established therapy and dosimetry centres. The multidisciplinary approach and different personnel requirements are discussed and key equipment reviewed example protocols demonstrating these factors are given in the supplementary material for the main therapies carried out in nuclear medicine, including [131I]-NaI for benign thyroid disorders, [177Lu]-DOTATATE and 131I-mIBG for neuroendocrine tumours and [90Y]-microspheres for unresectable hepatic carcinoma.


Assuntos
Tumores Neuroendócrinos , Radiometria , Humanos , Radiometria/métodos , Radioisótopos do Iodo , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/radioterapia , 3-Iodobenzilguanidina
16.
J Appl Clin Med Phys ; 24(8): e14001, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37086428

RESUMO

PURPOSE: Developed as a plan-specific pre-treatment QA tool, Varian portal dosimetry promises a fast, high-resolution, and integrated QA solution. In this study, the agreement between predicted fluence and measured cumulative portal dose was determined for the first 140 patient plans at our Halcyon linear accelerator. Furthermore, the capability of portal dosimetry to detect incorrect plan delivery was compared to that of a common QA phantom. Finally, tolerance criteria for verification of VMAT plan delivery with Varian portal dosimetry were derived. METHODS: All patient plans and the corresponding verification plans were generated within the Eclipse treatment planning system. Four representative plans of different treatment sites (prostate, prostate with lymphatic drainage, rectum, and head & neck) were intentionally altered to model incorrect plan delivery. Investigated errors included both systematic and random errors. Gamma analysis was conducted on both portal dose (criteria γ2%/2 mm , γ2%/1 mm , and γ1%/1 mm ) and ArcCHECK measurements (criteria γ3%/3 mm , γ3%/2 mm , and γ2%/2 mm ) with a 10% low-dose threshold. Performance assessment of various acceptance criteria for plan-specific treatment QA utilized receiver operating characteristic (ROC) analysis. RESULTS: Predicted and acquired portal dosimetry fluences demonstrated a high agreement evident by average gamma passing rates for the clinical patient plans of 99.90%, 96.64%, and 91.87% for γ2%/2 mm , γ2%/1 mm , and γ1%/1 mm , respectively. The ROC analysis demonstrated a very high capability of detecting erroneous plan delivery for portal dosimetry (area under curve (AUC) > 0.98) and in this regard outperforms QA with the ArcCHECK phantom (AUC ≈ 0.82). With the suggested optimum decision thresholds excellent sensitivity and specificity is simultaneously possible. CONCLUSIONS: Owing to the high achievable spatial resolution, portal dosimetry at the Halcyon can reliably be deployed as plan-specific pre-treatment QA tool to screen for errors. It is recommended to support the fluence integrated portal dosimetry QA by independent phantom-based measurements of a random sample survey of treatment plans.


Assuntos
Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador , Radiometria , Dosagem Radioterapêutica , Sensibilidade e Especificidade , Garantia da Qualidade dos Cuidados de Saúde
17.
Radiol Phys Technol ; 16(2): 227-234, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36947352

RESUMO

Treatment planning systems that use the Monte Carlo algorithm can calculate the dose to the medium (Dm) in non-water-equivalent tissues such as bones. However, Dm cannot be verified using actual measurements; therefore, it is necessary to develop tissue-equivalent dosimeters. In this study, we developed a bone-equivalent polymer gel dosimeter (BPGD) that can measure the dose absorbed by the bone and investigated its sensitivity. The BPGDs were prepared by adding 3.0 mol of calcium hydrogen phosphate dihydrate as a component of bone to an improved dose-sensitive polyacrylamide gelatin and tetrakis hydroxymethyl phosphonium chloride (iPAGAT). One day after preparation, the BPGDs were irradiated with a field size of 15 × 15 cm2 using a 10 MV X-ray beam to evaluate the dose sensitivity, dose-rate dependence, and dose-integration dependence. One day after dose exposure, the BPGDs were scanned using a 0.4 T MRI APERTO Eterna (Hitachi, Tokyo, Japan) to obtain R2 values. The difference between the R2 values of 6 Gy and 0 Gy was up to 5 s-1, and the R2 curve plateaued in the high-dose region. Moreover, the BPGD did not depend on the integration of the dose and dose rates. Therefore, the BPGDs that we developed can determine the radiation dose to bones.


Assuntos
Algoritmos , Dosímetros de Radiação , Japão , Método de Monte Carlo , Polímeros , Radiometria , Géis
18.
Phys Med ; 106: 102529, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36657235

RESUMO

Stray radiation produced by ultra-high dose-rates (UHDR) proton pencil beams is characterized using ASIC-chip semiconductor pixel detectors. A proton pencil beam with an energy of 220 MeV was utilized to deliver dose rates (DR) ranging from conventional radiotherapy DRs up to 270 Gy/s. A MiniPIX Timepix3 detector equipped with a silicon sensor and integrated readout electronics was used. The chip-sensor assembly and chipboard on water-equivalent backing were detached and immersed in the water-phantom. The deposited energy, particle flux, DR, and the linear energy transfer (LET(Si)) spectra were measured in the silicon sensor at different positions both laterally, at different depths, and behind the Bragg peak. At low-intensity beams, the detector is operated in the event-by-event data-driven mode for high-resolution spectral tracking of individual particles. This technique provides precise energy loss response and LET(Si) spectra with radiation field composition resolving power. At higher beam intensities a rescaling of LET(Si) can be performed as the distribution of the LET(Si) spectra exhibits the same characteristics regardless of the delivered DR. The integrated deposited energy and the absorbed dose can be thus measured in a wide range. A linear response of measured absorbed dose was obtained by gradually increasing the delivered DR to reach UHDR beams. Particle tracking of scattered radiation in data-driven mode could be performed at DRs up to 0.27 Gy/s. In integrated mode, the saturation limits were not reached at the measured out-of-field locations up to the delivered DR of over 270 Gy/s. A good agreement was found between measured and simulated absorbed doses.


Assuntos
Terapia com Prótons , Radiometria , Radiometria/métodos , Prótons , Silício , Transferência Linear de Energia , Água , Terapia com Prótons/métodos
19.
Appl Radiat Isot ; 192: 110580, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36462301

RESUMO

Significant research is being conducted on new materials suitable for dosimetry in recent decades with particular focus on their luminescent properties. For instance, a new ceramic detector, aluminum oxide 520 (ALOX-520), was developed at CDTN in 2011 using the sol-gel method. The detectors were doped with C, Fe, Mg, Ca, Cr, Ni, and Mo impurities that generated the necessary dosimetric trap levels to enhance the luminescence effects. Consequently, the resultant material was appropriate for the quantification of ionizing radiation fields by both thermally and optically stimulated luminescence techniques. Originally, ALOX 520 was sintered at 2023 K under a highly reducing atmosphere. At the end of this process, it exhibited important dosimetric properties, as already described in existing literature. The objective of this study is to conduct tests at higher temperatures in vacuum to investigate the effect of thermal treatments under these conditions on the structural and dosimetric properties of the material. Accordingly, ALOX-520 was re-sintered at high temperatures and the changes in its physical, morphological, and dosimetric properties were analyzed. ALOX 520T exhibited better dosimetric properties in terms of homogeneity, reproducibility, linearity, and signal fading. Physically, an increase in the detection threshold value of ALOX-520T could be linked to a decrease in the sensitivity of this detector. The energy dependence, the thermal quenching correction, and kinetic studies for ALOX-520T conducted as part of this work are original. However, the obtained results are consistent with those reported in the literature for α-Al2O3 ceramic detectors. XRD and XRF analyses demonstrated that the thermal treatment did not change the crystalline structure or composition of the material. All the results indicate that an appropriate thermal treatment could improve the dosimetric properties of the ALOX-520 detector without causing significant changes in its crystalline structure.


Assuntos
Óxido de Alumínio , Radiometria , Óxido de Alumínio/química , Reprodutibilidade dos Testes , Cinética , Medições Luminescentes , Dosimetria Termoluminescente/métodos
20.
Sensors (Basel) ; 22(15)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-35957376

RESUMO

Several detectors have been developed to measure radiation doses during radiotherapy. However, most detectors are not flexible. Consequently, the airgaps between the patient surface and detector could reduce the measurement accuracy. Thus, this study proposes a dose measurement system based on a flexible copper indium gallium selenide (CIGS) solar cell. Our system comprises a customized CIGS solar cell (with a size 10 × 10 cm2 and thickness 0.33 mm), voltage amplifier, data acquisition module, and laptop with in-house software. In the study, the dosimetric characteristics, such as dose linearity, dose rate independence, energy independence, and field size output, of the dose measurement system in therapeutic X-ray radiation were quantified. For dose linearity, the slope of the linear fitted curve and the R-square value were 1.00 and 0.9999, respectively. The differences in the measured signals according to changes in the dose rates and photon energies were <2% and <3%, respectively. The field size output measured using our system exhibited a substantial increase as the field size increased, contrary to that measured using the ion chamber/film. Our findings demonstrate that our system has good dosimetric characteristics as a flexible in vivo dosimeter. Furthermore, the size and shape of the solar cell can be easily customized, which is an advantage over other flexible dosimeters based on an a-Si solar cell.


Assuntos
Cobre , Índio , Gálio , Humanos , Doses de Radiação , Radiometria , Selênio , Raios X