1.
Int J Audiol ; 63(3): 221-225, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36811451

RESUMO

OBJECTIVE: The clinical audiology test battery often involves playing physically simple sounds with questionable ecological value to the listener. In this technical report, we revisit how valid this approach is using an automated, involuntary auditory response; the acoustic reflex threshold (ART). DESIGN: The ART was estimated four times in each individual in a quasi-random ordering of task conditions. The baseline condition (referred to as Neutral) measured the ART following a standard clinical practice. Three experimental conditions were then used in which a secondary task was performed whilst the reflex was measured: auditory attention, auditory distraction and visual distraction tasks. STUDY SAMPLE: Thirty-eight participants (27 males) with a mean age of 23 years were tested. All participants were audiometrically healthy. RESULTS: The ART was elevated when a visual task was performed at the same time as the measurements were taken. Performing an auditory task did not affect the ART. CONCLUSIONS: These data indicate that simple audiometric measures widely used in the clinic, can be affected by central, non-auditory processes even in healthy, normal-hearing volunteers. The role of cognition and attention on auditory responses will become ever more important in the coming years.


Assuntos
Testes Auditivos , Reflexo Acústico , Adulto , Humanos , Masculino , Adulto Jovem , Estimulação Acústica , Acústica , Audiometria , Limiar Auditivo/fisiologia , Reflexo Acústico/fisiologia , Feminino
2.
Acta Otolaryngol ; 141(12): 1055-1062, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34802365

RESUMO

BACKGROUND: Higher probe tone frequencies have been shown to increase the elicitation rates in electrically evoked stapedius reflex threshold (eSRT) measurements. OBJECTIVES: To determine the optimal probe tone frequency for contralateral eSRT measurements at individual electrodes in children with unilateral cochlear implants and to assess the relationship between eSRTs for this frequency and most comfortable levels (M-levels). MATERIALS AND METHODS: Contralateral eSRT measurements with three probe tone frequencies (226, 678, and 1000 Hz) at individual electrodes were performed on 26 paediatric Advanced Bionics cochlear implant recipients. RESULTS: The elicitation rates of eSRTs for 226, 678, and 1000 Hz probe tones were 73.08% (57/78), 88.46% (69/78), and 88.46% (69/78), respectively. The average eSRT for the 1000 Hz probe tone was significantly lower than those for 226 and 678 Hz probe tones (p<.001 and p=.009, respectively). ESRTs for the 1000 Hz probe tone and M-levels were significantly correlated at all tested electrodes (all p<.001). CONCLUSIONS AND SIGNIFICANCE: The optimal probe tone frequency for contralateral eSRT measurement at individual electrodes in children with unilateral cochlear implants is 1000 Hz. ESRTs for the 1000 Hz probe tone are significantly correlated with M-levels and can be used to guide the M-levels setting in these children.


Assuntos
Estimulação Acústica/métodos , Implantes Cocleares , Potenciais Evocados Auditivos , Reflexo Acústico/fisiologia , Potenciais de Ação , Criança , Pré-Escolar , Estimulação Elétrica/métodos , Feminino , Humanos , Masculino
3.
Auris Nasus Larynx ; 47(5): 769-777, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32404262

RESUMO

OBJECTIVE: To investigate the effects of long-term moderate noise on hearing functions, MOCR, and MEMR. METHODS: Mice were exposed to the moderate noise (11.2 - 22.4 kHz, 80 dB SPL, 6 h/day, 4 weeks). Subsequently, the hearing functions, including threshold and input-output roles of ABR (auditory brainstem response) and cubic (2f1-f2) DPOAEs (distortion product otoacoustic emissions) were evaluated. Also, MEMR and MOCR were assessed shortly after or at four weeks following the termination of exposure to the noise. RESULTS: The mice's acoustic suppression reflex was strengthened, hearing functions and MEMR were unaffected four weeks after the moderate noise. For primary tones of 16, 20 and 24 kHz, the strengths of contralateral and ipsilateral suppression in the noise group were about double those recorded in the control group. In order to further determine whether the functional changes of the afferent or efferent nerves increased the strengths of acoustic suppression, the mouse's left ear was inserted the earplug, and then exposed the moderate noise for four weeks. The strengths of contralateral suppression at 16, 20 and 24 kHz were increased for the noise + earplug than for the control group and were indistinguishable between the noise + earplug and the noise group. While no significant changes were found in the strengths of ipsilateral suppression at all frequencies for the noise + earplug group compared with the control group. Under ketamine/xylazine anesthesia, the broadband suppressor noise did not stimulate the MEMR by 20 min post-induction at all frequencies in three groups. CONCLUSION: Our data demonstrated that the long-term moderate noise-exposure strengthened mice's MOCR by changing its afferent nerves, and unaffected cochlear hair cells and type I spiral ganglion neurons.


Assuntos
Estimulação Acústica , Cóclea/fisiologia , Ruído , Reflexo Acústico/fisiologia , Animais , Cóclea/inervação , Masculino , Camundongos , Camundongos Endogâmicos CBA , Modelos Animais , Neurônios Aferentes/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia
4.
Int J Audiol ; 59(2): 140-147, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31584306

RESUMO

Objective: Assessments of the medial olivocochlear reflex (MOCR) may have clinical utility. The MOCR is measured using contralateral inhibition of otoacoustic emissions but concurrent activation of the middle ear muscle reflex (MEMR) confounds test interpretation. MEMR activation can be detected using the change in ear-canal stimulus amplitude without versus with an MOCR elicitor. This study provides a description of how critical differences in ear-canal stimulus amplitude can be established.Design: Clicks were presented in right ears without and with a contralateral MOCR elicitor. Ear-canal stimulus amplitudes were measured. Two measurements without an elicitor were used to develop critical differences. MEMR activation was considered present if the difference in ear-canal stimulus amplitude without versus with an elicitor exceeded the critical difference.Study sample: Forty-six normal-hearing adults (mean age = 23.4 years, 35 females) participated, with data from 44 participants included in the final analysis.Results: Two participants exceeded the 95% critical difference. The 80, 90 and 99% critical differences are also reported for reference.Conclusions: Results suggest that the contralateral elicitor can evoke the MEMR in a small number of participants. The methods described in this paper can be used for developing equipment- and clinic-specific critical differences for detecting MEMR activation.


Assuntos
Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Orelha Média/fisiologia , Testes Auditivos/estatística & dados numéricos , Reflexo Acústico/fisiologia , Cóclea/fisiologia , Limiar Diferencial , Meato Acústico Externo/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Músculo Esquelético/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Adulto Jovem
5.
Trends Hear ; 23: 2331216519874165, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31516095

RESUMO

The acoustic reflex (AR), a longstanding component of the audiological test battery, has received renewed attention in the context of noise-induced cochlear synaptopathy-the destruction of synapses between inner hair cells and auditory nerve fibers. Noninvasive proxy measures of synaptopathy are widely sought, and AR thresholds (ARTs) correlate closely with synaptic survival in rodents. However, measurement in humans at high stimulus frequencies-likely important when testing for noise-induced pathology-can be challenging; reflexes at 4 kHz are frequently absent or occur only at high stimulus levels, even in young people with clinically normal audiograms. This phenomenon may partly reflect differences across stimulus frequency in the temporal characteristics of the response; later onset of the response, earlier onset of adaptation, and higher rate of adaptation have been observed at 4 kHz than at 1 kHz. One temporal aspect of the response that has received little attention is the interstimulus interval (ISI); inadequate duration of ISI might lead to incomplete recovery of the response between successive presentations and consequent response fatigue. This research aimed to test for effects of ISI on ARTs in normally hearing young humans, measured at 1 and 4 kHz. Contrary to our hypotheses, increasing ISIs from 2.5 to 8.5 s did not reduce ART level, nor raise ART reliability. Results confirm that clinically measured ARTs-including those at 4 kHz-can exhibit excellent reliability and that relatively short (2.5 s) ISIs are adequate for the measurement of sensitive and reliable ARTs.


Assuntos
Estimulação Acústica , Limiar Auditivo/fisiologia , Reflexo Acústico/fisiologia , Adolescente , Cóclea , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Audição , Testes Auditivos , Humanos , Ruído , Reprodutibilidade dos Testes , Sinapses
6.
Hear Res ; 379: 103-116, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31150955

RESUMO

Many users of bilateral cochlear implants (BiCIs) localize sound sources less accurately than do people with normal hearing. This may be partly due to using two independently functioning CIs with fixed compression, which distorts and/or reduces interaural level differences (ILDs). Here, we investigate the potential benefits of using binaurally coupled, dynamic compression inspired by the medial olivocochlear reflex; an approach termed "the MOC strategy" (Lopez-Poveda et al., 2016, Ear Hear 37:e138-e148). Twelve BiCI users were asked to localize wideband (125-6000 Hz) noise tokens in a virtual horizontal plane. Stimuli were processed through a standard (STD) sound processing strategy (i.e., involving two independently functioning sound processors with fixed compression) and three different implementations of the MOC strategy: one with fast (MOC1) and two with slower contralateral control of compression (MOC2 and MOC3). The MOC1 and MOC2 strategies had effectively greater inhibition in the higher than in the lower frequency channels, while the MOC3 strategy had slightly greater inhibition in the lower than in the higher frequency channels. Localization was most accurate with the MOC1 strategy, presumably because it provided the largest and less ambiguous ILDs. The angle error improved slightly from 25.3° with the STD strategy to 22.7° with the MOC1 strategy. The improvement in localization ability over the STD strategy disappeared when the contralateral control of compression was made slower, presumably because stimuli were too short (200 ms) for the slower contralateral inhibition to enhance ILDs. Results suggest that some MOC implementations hold promise for improving not only speech-in-noise intelligibility, as shown elsewhere, but also sound source lateralization.


Assuntos
Implantes Cocleares , Localização de Som/fisiologia , Estimulação Acústica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Membrana Basilar/fisiopatologia , Implantes Cocleares/estatística & dados numéricos , Compressão de Dados , Processamento Eletrônico de Dados , Feminino , Perda Auditiva Bilateral/fisiopatologia , Perda Auditiva Bilateral/reabilitação , Humanos , Masculino , Pessoa de Meia-Idade , Órgão Espiral/fisiopatologia , Reflexo Acústico/fisiologia , Complexo Olivar Superior/fisiopatologia
7.
BMC Neurol ; 19(1): 144, 2019 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-31248379

RESUMO

BACKGROUND: Vestibular migraine (VM) has been recognized as a diagnostic entity over the past three decades. It affects up to 1% of the general population and 7% of patients seen in dizziness clinics. It is still underdiagnosed; consequently, it is important to conduct clinical studies that address diagnostic indicators of VM. The aim of this study was to assess auditory brainstem function in women with vestibular migraine using electrophysiological testing, contralateral acoustic reflex and loudness discomfort level. METHODS: The study group consisted of 29 women with vestibular migraine in the interictal period, and the control group comprised 25 healthy women. Auditory brainstem response, frequency following response, binaural interaction component and assessment of contralateral efferent suppression were performed. The threshold of loudness discomfort and the contralateral acoustic reflex were also investigated. The results were compared between the groups. RESULTS: There was a statistically significant difference between the groups in the frequency following response and the loudness discomfort level. CONCLUSIONS: The current study suggested that temporal auditory processing and loudness discomfort levels are altered in VM patients during the interictal period, indicating that these measures may be useful as diagnostic criteria.


Assuntos
Tronco Encefálico/fisiopatologia , Hiperacusia/etiologia , Hiperacusia/fisiopatologia , Transtornos de Enxaqueca/complicações , Transtornos de Enxaqueca/fisiopatologia , Estimulação Acústica , Adulto , Idoso , Estudos de Casos e Controles , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Feminino , Humanos , Pessoa de Meia-Idade , Reflexo Acústico/fisiologia , Adulto Jovem
8.
Neuroscience ; 407: 192-199, 2019 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-30890481

RESUMO

The occurrence of tinnitus is associated with hearing loss and neuroplastic changes in the brain, but disentangling correlation and causation has remained difficult in both human and animal studies. Here we use earplugs to cause a period of monaural deprivation to induce a temporary, fully reversible tinnitus sensation, to test whether differences in subcortical changes in neural response gain, as reflected through changes in acoustic reflex thresholds (ARTs), could explain the occurrence of tinnitus. Forty-four subjects with normal hearing wore an earplug in one ear for either 4 (n = 27) or 7 days (n = 17). Thirty subjects reported tinnitus at the end of the deprivation period. ARTs were measured before the earplug period and immediately after taking the earplug out. At the end of the earplug period, ARTs in the plugged ear were decreased by 5.9 ±â€¯1.1 dB in the tinnitus-positive group, and by 6.3 ±â€¯1.1 dB in the tinnitus-negative group. In the control ear, ARTs were increased by 1.3 ±â€¯0.8 dB in the tinnitus-positive group, and by 1.6 ±â€¯2.0 dB in the tinnitus-negative group. There were no significant differences between the groups with 4 and 7 days of auditory deprivation. Our results suggest that either the subcortical neurophysiological changes underlying the ART reductions might not be related to the occurrence of tinnitus, or that they might be a necessary component of the generation of tinnitus, but with additional changes at a higher level of auditory processing required to give rise to tinnitus. This article is part of a Special Issue entitled: Hearing Loss, Tinnitus, Hyperacusis, Central Gain.


Assuntos
Estimulação Acústica/efeitos adversos , Dispositivos de Proteção das Orelhas/efeitos adversos , Reflexo Acústico/fisiologia , Zumbido/etiologia , Estimulação Acústica/métodos , Adulto , Limiar Auditivo/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Plasticidade Neuronal/fisiologia , Zumbido/fisiopatologia , Adulto Jovem
9.
Am J Audiol ; 27(3): 349-353, 2018 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-29800116

RESUMO

PURPOSE: The purpose of this study is to investigate whether acoustic reflex threshold testing before administration of distortion product otoacoustic emissions can affect the results of the distortion product otoacoustic emissions testing using an automated protocol. METHOD: Fifteen young adults with normal hearing ranging in age from 19 to 25 years participated in the study. All participants had clear external ear canals and normal Jerger Type A tympanograms and had passed a hearing screening. Testing was performed using the Interacoustics Titan acoustic reflex threshold and distortion product otoacoustic emissions protocol. Participants underwent baseline distortion product otoacoustic emissions. RESULTS: A paired-samples t test was conducted for both the right and left ears to assess within-group differences between baseline distortion product otoacoustic emissions and repeated distortion product otoacoustic emissions measures. No significant differences were found in distortion product otoacoustic emission measures following administration of acoustic reflexes. CONCLUSIONS: The use of a protocol when using an automated system that includes both acoustic reflexes and distortion product otoacoustic emissions is important. Overall, presentation of acoustic reflexes prior to measuring distortion product otoacoustic emission did not affect distortion product otoacoustic emission results; therefore, test sequence can be modified as needed.


Assuntos
Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Reflexo Acústico/fisiologia , Testes de Impedância Acústica , Adulto , Audiometria de Tons Puros , Estudos de Coortes , Feminino , Voluntários Saudáveis , Humanos , Masculino , Sensibilidade e Especificidade , Adulto Jovem
10.
J Am Acad Audiol ; 29(4): 292-299, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29664723

RESUMO

BACKGROUND: One of the most important steps for good user performance with a cochlear implant (CI) is activation and programming, aimed at determining the dynamic range. In adults, current levels are determined by psychophysical measures. In babies, small children, or individuals with multiple disorders, this procedure requires techniques that may provide inconsistent responses because of auditory inexperience or the age of the child, making it a very difficult process that demands the collaboration of both the patient and the family. PURPOSE: To study the relationship between the electrically evoked stapedius reflex threshold (ESRT) and maximum comfort level for stimulating electrodes (C-level) in postoperative CI users. RESEARCH DESIGN: Cross-sectional analytical observational case series study. STUDY SAMPLE: We assessed 24 patients of both sexes, aged between 18 and 68 yr, submitted to CI surgery. INTERVENTION: Otoscopy and immittance. Next, an implant speech processor connected to an Itautec® computer containing the manufacturer's software (custom sound Ep 3-2) was used, as well as an AT 235h probe inserted into the ear contralateral to the CI to capture the stapedius reflex, obtaining electrically evoked stapedius reflex thresholds. DATA COLLECTION AND ANALYSIS: Data from the last programming, defining C-levels for each electrode studied, were extracted from the databank of each patient. The manual decay function of the AT 235h middle ear analyzer was used to observe ESRT response in a same window for a longer response capture time. Electrodes 22, 16, 11, 6, and 1 were tested when active, with the aim of using electrodes over the entire length of the CI, and ESRT was considered present when compliance was ≥0.05 ml. Stimuli, in current units, were always initiated at 20 cu above the C-level. The analysis of variance parametric test, Tukey's honest significant difference test, the t-test, Wilcoxon nonparametric test, and the Kolmogorov-Smirnov test examined whether significant relationships existed between these other factors. RESULTS: The results demonstrate that all the electrodes selected for the study exhibited higher mean reflex threshold values than their mean C-level counterparts. However, there was no significant difference between them, for electrodes 1, 6, 11, and 16. The data provided allow the use of ESRT to define C-level values and make it possible to stipulate a correction factor ranging between 6 and 25.6 electrical units. CONCLUSION: The use of electrically evoked stapedius reflex thresholds can help the team in charge of programming CIs, making the process faster and safer, mainly for infants, small children, or individuals with multiple disorders.


Assuntos
Estimulação Acústica , Implante Coclear/métodos , Implantes Cocleares , Estimulação Elétrica , Reflexo Acústico/fisiologia , Estimulação Acústica/métodos , Adolescente , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ajuste de Prótese , Estapédio/fisiologia , Adulto Jovem
11.
J Am Acad Audiol ; 29(4): 337-347, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29664726

RESUMO

BACKGROUND: The electrically evoked stapedial reflex threshold (ESRT) has been shown to be a good predictor of upper stimulation level for cochlear implant recipients. Previous research has shown that the ESRT may be recorded at lower stimulation levels and with a higher incidence of success with the use of higher frequency probe tones (e.g., 678 and 1000 Hz) relative to the use of the conventional 226-Hz probe tone. Research has also shown that the acoustic reflex may be recorded at lower stimulus levels with the use of wideband reflectance when compared to the acoustic reflex threshold recorded with a conventional acoustic immittance measurement. PURPOSE: The objective of this study was to compare the ESRT recorded with acoustic immittance and wideband reflectance measurements. RESEARCH DESIGN: A repeated measures design was used to evaluate potential differences in ESRTs with stimulation at an apical, middle, and basal electrode contact with the use of two different techniques, acoustic immittance measurement and wideband reflectance. STUDY SAMPLE: Twelve users of Cochlear Nucleus cochlear implants were included in the study. DATA COLLECTION AND ANALYSIS: Participants' ESRTs were evaluated in response to simulation at three different electrode contact sites (i.e., an apical, middle, and basal electrode contact) with the use of two different middle ear measurement techniques, acoustic immittance with the use of a 226-Hz probe tone and wideband reflectance with the use of a chirp stimulus. RESULTS: The mean ESRT recorded with wideband reflectance measurement was significantly lower when compared to the ESRT recorded with acoustic immittance. For one participant, the ESRT was not recorded with acoustic immittance before reaching the participant's loudness discomfort threshold, but it was successfully recorded with the use of wideband reflectance. CONCLUSIONS: The ESRT may potentially be recorded at lower presentation levels with the use of wideband reflectance measures relative to the use of acoustic immittance with a 226-Hz probe tone. This may allow for the ESRT to be obtained at levels that are more comfortable for the cochlear implant recipient, which may also allow for a higher incidence in the successful recording of the ESRT.


Assuntos
Testes de Impedância Acústica/métodos , Estimulação Acústica , Estimulação Elétrica , Reflexo Acústico/fisiologia , Estimulação Acústica/métodos , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Estapédio/fisiologia , Adulto Jovem
12.
Int J Audiol ; 57(7): 493-501, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29433374

RESUMO

OBJECTIVE: A previous study [Rawool, V. W. (2016). Auditory processing deficits: Assessment and intervention. New York, NY: Thieme Medical Publishers, Inc., pp. 186-187] demonstrated objective assessment of binaural summation through right contralateral acoustic reflex thresholds (ARTs) in women. The current project examined if previous findings could be generalised to men and to the left ear. DESIGN: Cross-sectional. STUDY SAMPLE: Sixty individuals participated in the study. Left and right contralateral ARTs were obtained in two conditions. In the alternated condition, the probe tone presentation was alternated with the presentation of the reflex activating clicks. In the simultaneous condition, the probe tone and the clicks were presented simultaneously. Binaural summation was calculated by subtracting the ARTs obtained in the simultaneous condition from the ARTs obtained in the alternated condition. RESULTS: MANOVA on ARTs revealed no significant gender or ear effects. The ARTs were significantly lower/better in the simultaneous condition compared to the alternated condition. CONCLUSIONS: Binaural summation was 4 dB or higher in 88% of the ears and 6 dB or higher in 76% of ears. Stimulation of six out of the total 120 (0.5%) ears resulted in worse thresholds in the simultaneous condition compared with the alternating condition, suggesting binaural interference.


Assuntos
Limiar Auditivo/fisiologia , Percepção Sonora , Reflexo Acústico/fisiologia , Fatores Sexuais , Estimulação Acústica/métodos , Adulto , Estudos Transversais , Feminino , Lateralidade Funcional/fisiologia , Humanos , Masculino , Adulto Jovem
13.
Ear Hear ; 39(3): 605-614, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29189520

RESUMO

OBJECTIVES: The long-term goal of this research is to determine whether the middle ear muscle reflex can be used to predict the number of healthy auditory nerve fibers in hearing-impaired ears. In this study, we develop a high-impedance source and an animal model of the middle ear muscle reflex and explore the influence of signal frequency and level on parameters of the reflex to determine an optimal signal to examine auditory nerve fiber survival. DESIGN: A high-impedance source was developed using a hearing aid receiver attached to a 0.06 diameter 10.5-cm length tube. The impedance probe consisted of a microphone probe placed near the tip of a tube coupled to a sound source. The probe was calibrated by inserting it into a syringe of known volumes and impedances. The reflex in the anesthetized rat was measured with elicitor stimuli ranging from 3 to 16 kHz presented at levels ranging from 35 to 100 dB SPL to one ear while the reflex was measured in the opposite ear containing the probe and probe stimulus. RESULTS: The amplitude of the reflex increased with elicitor level and was largest at 3 kHz. The lowest threshold was approximately 54 dB SPL for the 3-kHz stimulus. The rate of decay of the reflex was greatest at 16 kHz followed by 10 and 3 kHz. The rate of decay did not change significantly with elicitor signal level for 3 and 16 kHz, but decreased as the level of the 10-kHz elicitor increased. A negative feedback model accounts for the reflex decay by having the strength of feedback dependent on auditory nerve input. The rise time of the reflex varied with frequency and changed with level for the 10- and 16-kHz signals but not significantly for the 3-kHz signal. The latency of the reflex increased with a decrease in elicitor level, and the change in latency with level was largest for the 10-kHz stimulus. CONCLUSIONS: Because the amplitude of the reflex in rat was largest with an elicitor signal at 3 kHz, had the lowest threshold, and yielded the least amount of decay, this may be the ideal frequency to estimate auditory nerve survival in hearing-impaired ears.


Assuntos
Limiar Auditivo , Nervo Coclear/fisiopatologia , Orelha Média/fisiologia , Degeneração Neural/diagnóstico , Reflexo Acústico/fisiologia , Estimulação Acústica , Anestésicos Dissociativos/farmacologia , Animais , Biomarcadores , Ketamina/farmacologia , Modelos Animais , Degeneração Neural/fisiopatologia , Ratos , Ratos Long-Evans , Reflexo Acústico/efeitos dos fármacos
14.
Brain Struct Funct ; 223(4): 1731-1745, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29204911

RESUMO

Previous studies have shown that exposure to stressful events can enhance fear memory and anxiety-like behavior as well as increase synaptic plasticity in the rat basolateral amygdala (BLA). We have evidence that repeated unpredictable shock stress (USS) elicits a long-lasting increase in anxiety-like behavior in rats, but the cellular mechanisms mediating this response remain unclear. Evidence from recent morphological studies suggests that alterations in the dendritic arbor or spine density of BLA principal neurons may underlie stress-induced anxiety behavior. Recently, we have shown that the induction of long-term potentiation (LTP) in BLA principal neurons is dependent on activation of postsynaptic D1 dopamine receptors and the subsequent activation of the cyclic adenosine 5'-monophosphate (cAMP)-protein kinase A (PKA) signaling cascade. Here, we have used in vitro whole-cell patch-clamp recording from BLA principal neurons to investigate the long-term consequences of USS on their morphological properties and synaptic plasticity. We provided evidence that the enhanced anxiety-like behavior in response to USS was not associated with any significant change in the morphological properties of BLA principal neurons, but was associated with a changed frequency dependence of synaptic plasticity, lowered LTP induction threshold, and reduced expression of phosphodiesterase type 4 enzymes (PDE4s). Furthermore, pharmacological inhibition of PDE4 activity with rolipram mimics the effects of chronic stress on LTP induction threshold and baseline startle. Our results provide the first evidence that stress both enhances anxiety-like behavior and facilitates synaptic plasticity in the amygdala through a common mechanism of PDE4-mediated disinhibition of cAMP-PKA signaling.


Assuntos
Complexo Nuclear Basolateral da Amígdala/patologia , Nucleotídeo Cíclico Fosfodiesterase do Tipo 4/metabolismo , Plasticidade Neuronal/fisiologia , Neurônios/fisiologia , Estresse Psicológico/patologia , Estimulação Acústica/efeitos adversos , Animais , Ansiedade/etiologia , Complexo Nuclear Basolateral da Amígdala/fisiopatologia , Benzazepinas/farmacologia , Nucleotídeo Cíclico Fosfodiesterase do Tipo 4/genética , Modelos Animais de Doenças , Antagonistas de Dopamina/farmacologia , Regulação para Baixo/efeitos dos fármacos , Estimulação Elétrica , Técnicas In Vitro , Plasticidade Neuronal/efeitos dos fármacos , Técnicas de Patch-Clamp , Inibidores da Fosfodiesterase 4/farmacologia , Psicoacústica , RNA Mensageiro/metabolismo , Ratos , Ratos Sprague-Dawley , Reflexo Acústico/efeitos dos fármacos , Reflexo Acústico/fisiologia , Rolipram/farmacologia , Estresse Psicológico/complicações , Estresse Psicológico/tratamento farmacológico , Estresse Psicológico/etiologia
15.
Physiol Int ; 104(2): 171-182, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28648121

RESUMO

We hypothesized that cochlear frequency discrimination occurs through medial olivocochlear efferent (MOCE)-induced alterations in outer hair cell (OHC) electromotility, which is independent from basilar membrane traveling waves. After obtaining informed consent, volunteers with normal hearing (n = 10; mean age: 20.6 ± 1.2 years) and patients with unilateral deafness (n = 10; mean age: 30.2 ± 17.9 years) or bilateral deafness (n = 8; mean age: 30.7 ± 13.8 years) underwent a complete physical and audiological examination, and audiological tests including transient evoked otoacoustic emission and spontaneous otoacoustic emission (TEOAE and SOAE, respectively). SOAE recordings were performed during contralateral pure-tone stimuli at 1 and 3 kHz. SOAE recordings in the presence of contralateral pure-tone stimuli showed frequency-specific activation out of the initial frequency range of SOAE responses. Basilar membrane motion during pure-tone stimulation results from OHC activation by means of MOCE neurons rather than from a traveling wave. Eventually, frequency-specific responses obtained from SOAEs suggested that OHC electromotility may be responsible for frequency discrimination of the cochlea independently from basilar membrane motion.


Assuntos
Estimulação Acústica/métodos , Vias Auditivas/fisiologia , Cóclea/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Percepção da Altura Sonora/fisiologia , Reflexo Acústico/fisiologia , Complexo Olivar Superior/fisiologia , Cóclea/inervação , Feminino , Humanos , Masculino , Adulto Jovem
16.
HNO ; 65(Suppl 2): 122-129, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28470484

RESUMO

BACKGROUND: Distortion product otoacoustic emissions (DPOAEs) and transient-evoked otoacoustic emissions (TEOAEs) are sound waves generated as byproducts of the cochlear amplifier. These are measurable in the auditory canal and represent an objective method for diagnosing functional disorders of the inner ear. Conventional DPOAE and TEOAE methods permit detection of hearing impairment, but with less than desirable accuracy. OBJECTIVE: By accounting for DPOAE generation mechanisms, the aim is to improve the accuracy of inner-ear diagnosis. METHODS: DPOAEs consist of two components, which emerge at different positions along the cochlea and which may cause artifacts due to mutual interference. Here, the two components are separated in the time domain using short stimulus pulses. Optimized stimulus levels facilitate the acquisition of DPOAEs with maximum amplitudes. DPOAE and Békésy audiograms were recorded from 41 subjects in a clinically relevant frequency range of 1.5-6 kHz. RESULTS: The short stimulus pulses allowed artifact-free measurement of DPOAEs. Semilogarithmic input-output functions yielded estimated distortion product thresholds, which were significantly correlated with the subjectively acquired Békésy thresholds. In addition, they allowed detection of hearing impairment from 20 dB HL, with 95% sensitivity and only a 5% false-positive rate. This accuracy was achieved with a measurement time of about 1-2 min per frequency. CONCLUSION: Compared to conventional DPOAE and TEOAE methods, separation of DPOAE components using short-pulse DPOAEs in combination with optimized stimulus parameters considerably enhances the accuracy of DPOAEs for diagnosing impairment of the cochlear amplifier.


Assuntos
Perda Auditiva/diagnóstico , Emissões Otoacústicas Espontâneas/fisiologia , Estimulação Acústica , Limiar Auditivo/fisiologia , Cóclea/fisiopatologia , Meato Acústico Externo/fisiopatologia , Orelha Interna/fisiopatologia , Perda Auditiva/fisiopatologia , Humanos , Reflexo Acústico/fisiologia
17.
Restor Neurol Neurosci ; 35(1): 77-85, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28059800

RESUMO

BACKGROUND: Patients suffering from chronic disorders of consciousness (DOC), including minimally conscious state (MCS) and unresponsive wakefulness syndrome (UWS), typically show an awareness impairment paralleled by a significant reflex hyper-excitability, which depend on the cortical deafferentation following brain-damage-induced thalamocortical system deterioration. Nonetheless, recent studies have shown a residual preservation of cortico-subcortical pathways that may sustain residual fragments of awareness in some DOC patients. OBJECTIVE: The aim of our study was to assess whether the cortical modulation of auditory stapedial reflex (ASR) could be a marker of a higher degree of brain network connectivity, which is a fundamental prerequisite for awareness generation and maintenance. METHODS: We applied a repetitive transcranial magnetic stimulation (rTMS) protocol over the primary auditory area and measured the neuromodulation effects on ASR threshold (ASRt) in a DOC sample and a healthy control group (HC). RESULTS: We observed an ASRt reduction in all the HC and MCS individuals, in parallel to a better sound-induced motor responsiveness in MCS sample, while all the UWS patients, but two, did not show any significant ASRt modulation. CONCLUSION: We hypothesize that our conditioning protocol may have entrained and potentiated some spared cortico-subcortical networks that sustained the clinical and electrophysiological amelioration we found. Our data electrophysiologically demonstrate for the first time that primary the auditory area can influence ASR elicitation, and such finding may support the DOC differential diagnosis.


Assuntos
Córtex Auditivo/fisiologia , Transtornos da Consciência/fisiopatologia , Reflexo Acústico/fisiologia , Estimulação Acústica , Doença Crônica , Transtornos da Consciência/reabilitação , Feminino , Humanos , Masculino , Estatísticas não Paramétricas , Estimulação Magnética Transcraniana
18.
J Assoc Res Otolaryngol ; 18(1): 65-88, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27957612

RESUMO

Power-based procedures are described to measure acoustic stapedius-muscle reflex threshold and supra-threshold responses in human adult and infant ears at frequencies from 0.2 to 8 kHz. The stimulus set included five clicks in which four pulsed activators were placed between each pair of clicks, with each stimulus set separated from the next by 0.79 s to allow for reflex decay. Each click response was used to detect the presence of reflex effects across frequency that were elicited by a pulsed broadband-noise or tonal activator in the ipsilateral or contralateral test ear. Acoustic reflex shifts were quantified in terms of the difference in absorbed sound power between the initial baseline click and the later four clicks in each set. Acoustic reflex shifts were measured over a 40-dB range of pulsed activators, and the acoustic reflex threshold was objectively calculated using a maximum 10 likelihood procedure. To illustrate the principles underlying these new reflex tests, reflex shifts in absorbed sound power and absorbance are presented for data acquired in an adult ear with normal hearing and in two infant ears in the initial and follow-up newborn hearing screening exams, one with normal hearing and the other with a conductive hearing loss. The use of absorbed sound power was helpful in classifying an acoustic reflex shift as present or absent. The resulting reflex tests are in use in a large study of wideband clinical diagnosis and monitoring of middle-ear and cochlear function in infant and adult ears.


Assuntos
Limiar Auditivo , Reflexo Acústico/fisiologia , Estimulação Acústica , Adulto , Audição , Perda Auditiva Condutiva/fisiopatologia , Humanos , Lactente , Recém-Nascido
19.
Neurotoxicology ; 57: 13-21, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27565678

RESUMO

Some volatile aromatic solvents have similar or opposite effects to anesthetics in the central nervous system. Like for anesthetics, the mechanisms of action involved are currently the subject of debate. This paper presents an in vivo study to determine whether direct binding or effects on membrane fluidity best explain how solvents counterbalance anesthesia's depression of the middle-ear reflex (MER). Rats were anesthetized with a mixture of ketamine and xylazine while also exposed to solvent vapors (toluene, ethylbenzene, or one of the three xylene isomers) and the amplitude of their MER was monitored. The depth of anesthesia was standardized based on the magnitude of the contraction of the muscles involved in the MER, determined by measuring cubic distortion product oto-acoustic emissions (DPOAEs) while triggering the bilateral reflex with contralateral acoustic stimulation. The effects of the aromatic solvents were quantified based on variations in the amplitude of the DPOAEs. The amplitude of the alteration to the MER measured in anesthetized rats did not correlate with solvent lipophilocity (as indicated by logKow values). Results obtained with the three xylene isomers indicated that the positions of two methyl groups around the benzene ring played a determinant role in solvent/neuronal cell interaction. Additionally, Solid-state Nuclear Magnetic Resonance (NMR) spectra for brain microsomes confirmed that brain lipid fluidity was unaffected by solvent exposure, even after three days (6h/day) at an extremely high concentration (3000ppm). Therefore, aromatic solvents appear to act directly on the neuroreceptors involved in the acoustic reflex circuit, rather than on membrane fluidity. The affinity of this interaction is determined by stereospecific parameters rather than lipophilocity.


Assuntos
Orelha Média/fisiologia , Fluidez de Membrana/efeitos dos fármacos , Reflexo Acústico/efeitos dos fármacos , Solventes/farmacologia , Estimulação Acústica , Animais , Encéfalo/metabolismo , Orelha Média/efeitos dos fármacos , Lateralidade Funcional/efeitos dos fármacos , Espectroscopia de Ressonância Magnética , Masculino , Fluidez de Membrana/fisiologia , Emissões Otoacústicas Espontâneas/efeitos dos fármacos , Ratos , Reflexo Acústico/fisiologia , Solventes/metabolismo , Tolueno/farmacologia , Trítio/farmacocinética
20.
Dokl Biochem Biophys ; 468(1): 224-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27417727

RESUMO

The results of an experimental study of manifestations of the acoustic reflex with contralateral auditory stimulation at a frequency of 1 kHz are presented, and the principal possibility and informativeness of its use for diagnosing the diseases of the organ of hearing are demonstrated. The principal difference of the developed approach is the use of polyharmonic signal for measuring acoustic reflex manifestations during contralateral stimulation, which allows accelerating the examination procedure.


Assuntos
Reflexo Acústico/fisiologia , Estimulação Acústica/métodos , Meato Acústico Externo/fisiologia , Lateralidade Funcional , Humanos , Modelos Biológicos , Pressão , Membrana Timpânica/fisiologia