Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.104
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Nefrologia (Engl Ed) ; 44(2): 159-164, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38631962

RESUMO

Hyponatremia is a multifactorial disorder defined as a decrease in plasma sodium concentration. Its differential diagnosis requires an adequate evaluation of the extracellular volume (ECV). However, ECV determination, simply based on the clinical history, vital signs, physical examination, and laboratory findings can leads to misdiagnosis and inappropriate treatment. The use of Point-of-Care Ultrasound (POCUS), through the combination of Lung Ultrasound (LUS), Venous Excess UltraSound (VExUS) and Focused Cardiac Ultrasound (FoCUS), allows a much more accurate holistic assessment of the patient's ECV status in combination with the other parameters.


Assuntos
Hiponatremia , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Humanos , Hiponatremia/etiologia , Hiponatremia/diagnóstico por imagem , Ultrassonografia/métodos , Medicina de Precisão , Pulmão/diagnóstico por imagem
2.
BMC Womens Health ; 24(1): 219, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575899

RESUMO

INTRODUCTION: Non-invasive biofeedback of pelvic floor muscle training (PFMT) is required for continuous training in home care. Therefore, we considered self-performed ultrasound (US) in adult women with a handheld US device applied to the bladder. However, US images are difficult to read and require assistance when using US at home. In this study, we aimed to develop an algorithm for the automatic evaluation of pelvic floor muscle (PFM) contraction using self-performed bladder US videos to verify whether it is possible to automatically determine PFM contraction from US videos. METHODS: Women aged ≥ 20 years were recruited from the outpatient Urology and Gynecology departments of a general hospital or through snowball sampling. The researcher supported the participants in their self-performed bladder US and videos were obtained several times during PFMT. The US videos obtained were used to develop an automatic evaluation algorithm. Supervised machine learning was then performed using expert PFM contraction classifications as ground truth data. Time-series features were generated from the x- and y-coordinate values of the bladder area including the bladder base. The final model was evaluated for accuracy, area under the curve (AUC), recall, precision, and F1. The contribution of each feature variable to the classification ability of the model was estimated. RESULTS: The 1144 videos obtained from 56 participants were analyzed. We split the data into training and test sets with 7894 time series features. A light gradient boosting machine model (Light GBM) was selected, and the final model resulted in an accuracy of 0.73, AUC = 0.91, recall = 0.66, precision = 0.73, and F1 = 0.73. Movement of the y-coordinate of the bladder base was shown as the most important. CONCLUSION: This study showed that automated classification of PFM contraction from self-performed US videos is possible with high accuracy.


Assuntos
Contração Muscular , Diafragma da Pelve , Adulto , Feminino , Humanos , Diafragma da Pelve/diagnóstico por imagem , Diafragma da Pelve/fisiologia , Contração Muscular/fisiologia , Bexiga Urinária/diagnóstico por imagem , Biorretroalimentação Psicológica/métodos , Ultrassonografia
3.
PLoS One ; 19(3): e0297985, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38498581

RESUMO

OBJECTIVES: We conducted a comprehensive meta-analysis to compare the effectiveness and safety of fluoroscopy-guided air enema reduction (FGAR) and ultrasound-guided hydrostatic enema reduction (UGHR) for the treatment of intussusception in pediatric patients. METHODS: A systematic review and meta-analysis were conducted on retrospective studies obtained from various databases, including PUBMED, MEDLINE, Cochrane, Google Scholar, China National Knowledge Infrastructure (CNKI), WanFang, and VIP Database. The search included publications from January 1, 2003, to March 31, 2023, with the last search done on Jan 15, 2023. RESULTS: We included 49 randomized controlled studies and retrospective cohort studies involving a total of 9,391 patients, with 4,841 in the UGHR and 4,550 in the FGAR. Specifically, UGHR exhibited a significantly shorter time to reduction (WMD = -4.183, 95% CI = (-5.402, -2.964), P < 0.001), a higher rate of successful reduction (RR = 1.128, 95% CI = (1.099, 1.157), P < 0.001), and a reduced length of hospital stay (WMD = -1.215, 95% CI = (-1.58, -0.85), P < 0.001). Furthermore, UGHR repositioning was associated with a diminished overall complication rate (RR = 0.296, 95% CI = (0.225, 0.389), P < 0.001) and a lowered incidence of perforation (RR = 0.405, 95% CI = (0.244, 0.670), P < 0.001). CONCLUSION: UGHR offers the benefits of being non-radioactive, achieving a shorter reduction time, demonstrating a higher success rate in repositioning in particular, resulting in a reduced length of postoperative hospital stay, and yielding a lower overall incidence of postoperative complications, including a reduced risk of associated perforations.


Assuntos
Intussuscepção , Criança , Humanos , Enema/métodos , Fluoroscopia , Intussuscepção/terapia , Estudos Retrospectivos , Ultrassonografia
4.
Int J Pharm ; 655: 124015, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38527565

RESUMO

Sonodynamic therapy (SDT) utilizes ultrasonic excitation of a sensitizer to generate reactive oxygen species (ROS) to destroy tumor. Two dimensional (2D) black phosphorus (BP) is an emerging sonosensitizer that can promote ROS production to be used in SDT but it alone lacks active targeting effect and showed low therapy efficiency. In this study, a stable dispersion of integrated micro-nanoplatform consisting of BP nanosheets loaded and Fe3O4 nanoparticles (NPs) connected microbubbles was introduced for ultrasound imaging guided and magnetic field directed precision SDT of breast cancer. The targeted ultrasound imaging at 18 MHz and efficient SDT effects at 1 MHz were demonstrated both in-vitro and in-vivo on the breast cancer. The magnetic microbubbles targeted deliver BP nanosheets to the tumor site under magnetic navigation and increased the uptake of BP nanosheets by inducing cavitation effect for increased cell membrane permeability via ultrasound targeted microbubble destruction (UTMD). The mechanism of SDT by magnetic black phosphorus microbubbles was proposed to be originated from the ROS triggered mitochondria mediated apoptosis by up-regulating the pro-apoptotic proteins while down-regulating the anti-apoptotic proteins. In conclusion, the ultrasound theranostic was realized via the magnetic black phosphorus microbubbles, which could realize targeting and catalytic sonodynamic therapy.


Assuntos
Neoplasias da Mama , Terapia por Ultrassom , Humanos , Feminino , Microbolhas , Espécies Reativas de Oxigênio/metabolismo , Linhagem Celular Tumoral , Ultrassonografia , Terapia por Ultrassom/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Fósforo , Fenômenos Magnéticos
5.
J Bodyw Mov Ther ; 37: 399-403, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432836

RESUMO

BACKGROUND: Ultrasonography (US) has been suggested to assess the morphology and function of cervical muscles; but little is known about the reliability of the US measures in patients with cervical disc herniation (CDH). The purpose of this study was to evaluate within-day inter and intra-rater and between-day intra-rater reliability of US to measure dimensions of deep cervical muscles in patients with unilateral CDH. METHODS: Thirty patients with unilateral CDH participated. Anterior-posterior and lateral dimension of longus colli (LC), multifidus (MF) and semispinalis cervicis (SC) were measured using B-mode ultrasound. The measurements were repeated by rater A 1 h (for within-day reliability) and one week (for between-day reliability) later. For inter-rater reliability, rater B performed all muscles measurements like rater A. RESULTS: Within-day reliability measurement for all muscles was good to excellent with IntraClass Correlation Coefficients (ICC) ranging from 0.82 to 0.96, standard error of measurement (SEM) from 0.18 to 0.46 and minimal detectable changes (MDC) from 0.43 to 1.09. Between-day reliability was good for all muscle dimensions with ICC ranging from 0.75 to 0.89, SEM from 0.30 to 0.64 and MDC from 0.71 to 1.52. Inter-rater reliability was also good with ICC ranging from 0.75 to 0.89, SEM from 0.34 to 0.65 and MDC from 0.81 to 1.55. CONCLUSIONS: US was demonstrated to have high within-day inter and intra-rater and between-day intra-rater reliability to measure muscles dimensions in patients with unilateral CDH. It can be used to assess deep cervical muscles or to monitor the effects of interventions.


Assuntos
Deslocamento do Disco Intervertebral , Músculos Paraespinais , Humanos , Músculos Paraespinais/diagnóstico por imagem , Estudos Transversais , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Reprodutibilidade dos Testes , Músculos do Pescoço/diagnóstico por imagem , Ultrassonografia
6.
J Bodyw Mov Ther ; 37: 90-93, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432847

RESUMO

BACKGROUND: Retinacula of the ankle are thickening of the deep fascia of the leg (crural fascia) and foot i.e. inseparable structures. Recent studies report their crucial role in functional stability and proprioception of the ankle. CASE PRESENTATION: A 38-yr-old Caucasian man - with a history of lateral malleolus fracture 12 years ago, obesity and right ankle osteoarthritis - was referred to a physiatrist for a right ankle pain that had significantly worsened over the last year. During walking, the patient experienced stinging pain in the area of tibialis anterior and peroneus tertius muscles, and the superior extensor retinaculum. Magnetic resonance imaging and ultrasonography showed clear thicknening (2.05 mm) of the oblique superomedial band of the inferior extensor retinaculum. Sonopalpation was performed to precisely evaluate/confirm the site of maximum pain. Foot function index (FFI) score was 42. RESULTS: Subsequently, the patient was prescribed fascial manipulation, and he had clinical improvement after the first session (FFI: 21). At 1-month follow-up, the patient was still asymptomatic without any functional limitation (FFI: 24). US imaging confirmed the decreased thickness of the oblique superomedial band of the extensor retinaculum (1.35 mm). CONCLUSION: Fascial Manipulation® appears to be a useful tool to reduce thickness, stiffness, and pain in this case as displayed by the ultrasound Imaging.


Assuntos
Tornozelo , Osteoartrite , Masculino , Humanos , Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/diagnóstico por imagem , Ultrassonografia , Fáscia/diagnóstico por imagem , Dor
7.
Nanotheranostics ; 8(2): 127-149, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38328614

RESUMO

Cardiovascular disease is one of the chief factors that cause ischemic stroke, myocardial infarction, and venous thromboembolism. The elements that speed up thrombosis include nutritional consumption, physical activity, and oxidative stress. Even though the precise etiology and pathophysiology remain difficult topics that primarily rely on traditional medicine. The diagnosis and management of thrombosis are being developed using discrete non-invasive and non-surgical approaches. One of the emerging promising approach is ultrasound and photoacoustic imaging. The advancement of nanomedicines offers concentrated therapy and diagnosis, imparting efficacy and fewer side effects which is more significant than conventional medicine. This study addresses the potential of nanomedicines as theranostic agents for the treatment of thrombosis. In this article, we describe the factors that lead to thrombosis and its consequences, as well as summarize the findings of studies on thrombus formation in preclinical and clinical models and also provide insights on nanoparticles for thrombus imaging and therapy.


Assuntos
Nanopartículas , Trombose , Humanos , Medicina de Precisão , Trombose/diagnóstico por imagem , Trombose/terapia , Ultrassonografia/métodos , Nanopartículas/uso terapêutico
9.
World J Gastroenterol ; 30(5): 499-508, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38414592

RESUMO

BACKGROUND: Superior mesenteric artery (SMA) syndrome is a rare cause of duodenal obstruction by extrinsic compression between the SMA and the aorta (SMA-Ao). Although the left lateral recumbent position is considered effective in the treatment of SMA syndrome, individual variations in the optimal patient position have been noted. In this report, we present two elderly cases of SMA syndrome that exhibited rapid recovery due to ultrasonographic dynamic evaluation of the optimal position for each patient. CASE SUMMARY: Case 1: A 90-year-old man with nausea and vomiting. Following diagnosis of SMA syndrome by computed tomography (CT), ultrasonography (US) revealed the SMA-Ao distance in the supine position (4 mm), which slightly improved in the lateral position (5.7-7.0 mm) without the passage of duodenal contents. However, in the sitting position, the SMA-Ao distance was increased to 15 mm accompanied by improved content passage. Additionally, US indicated enhanced passage upon abdominal massage on the right side. By day 2, the patient could eat comfortably with the optimal position and massage. Case 2: An 87-year-old woman with vomiting. After the diagnosis of SMA syndrome and aspiration pneumonia by CT, dynamic US confirmed the optimal position (SMA-Ao distance was improved to 7 mm in forward-bent position, whereas it remained at 5 mm in the supine position). By day 7 when her pneumonia recovered, she could eat with the optimal position. CONCLUSION: The optimal position for SMA syndrome varies among individuals. Dynamic US appears to be a valuable tool in improving patient outcomes.


Assuntos
Obstrução Duodenal , Síndrome da Artéria Mesentérica Superior , Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Síndrome da Artéria Mesentérica Superior/diagnóstico por imagem , Síndrome da Artéria Mesentérica Superior/terapia , Síndrome da Artéria Mesentérica Superior/complicações , Obstrução Duodenal/diagnóstico , Ultrassonografia/efeitos adversos , Vômito/diagnóstico por imagem , Vômito/etiologia , Tomografia Computadorizada por Raios X/efeitos adversos , Artéria Mesentérica Superior/diagnóstico por imagem
10.
Clin Exp Rheumatol ; 42(3): 626-632, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38197192

RESUMO

OBJECTIVES: We aimed to 1) evaluate by power Doppler (PD) ultrasound (US) the response to therapy of the most inflamed joint and enthesis (target sites) in psoriatic arthritis (PsA) patients starting a biologic disease-modifying anti-rheumatic drug (bDMARD); and 2) to investigate the correlation between the US response and clinical data. METHODS: Consecutive PsA patients with US synovitis and US 'active' enthesitis, starting a bDMARD, were included. The joint with the highest OMERACT-EULAR-US composite score and the enthesis with the highest PD grade (targets) were identified at baseline. The US examination and clinical assessment were performed at 0, 3 and 6 months. The response of OMERACT-EULAR-US synovitis composite score was defined as reaching a grade = 0 at follow-up examination; synovial and entheseal PD responses were defined as a PD=0 and/or a reduction of ≥2 PD grades at follow-up examination. RESULTS: Thirty patients were included. Synovitis composite score, synovial PD and entheseal PD showed significant responses at 3 and 6 months compared to baseline (p<0.01). Synovial PD responses were higher than entheseal PD responses at 3 months (71.4% vs 40.0%, p=0.01) and 6 months (77.8% vs. 46.7%, p=0.02). US synovitis responses were correlated with DAPSA (p<0.01) and MDA responses (p=0.01 for composite score, p=0.02 for PD). CONCLUSIONS: US was found sensitive for monitoring treatment response in PsA patients starting a biologic drug. Entheseal PD was less responsive than synovial PD, suggesting that enthesitis may represent a 'difficult-to-treat' domain in PsA.


Assuntos
Antirreumáticos , Artrite Psoriásica , Entesopatia , Sinovite , Humanos , Artrite Psoriásica/diagnóstico por imagem , Artrite Psoriásica/tratamento farmacológico , Ultrassonografia , Sinovite/diagnóstico por imagem , Sinovite/tratamento farmacológico , Antirreumáticos/uso terapêutico , Entesopatia/diagnóstico por imagem , Entesopatia/tratamento farmacológico , Entesopatia/etiologia , Terapia Biológica , Ultrassonografia Doppler
11.
Ultrason Sonochem ; 103: 106779, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38262175

RESUMO

Potato chips are popular high-consuming ready-to-eat meals in all of the world which specially attract a lot of attention from youth and children. Reducing oil absorption and improving the quality of chips are major undertakings within the industry. This research aimed to find the best ultrasonic bath-based method by investigating the optimal ultrasonic pre-treatment and developing an ultrasound (US) assisted frying system (UAFS) to reduce the oil absorption of potato chips while maintaining an acceptable quality. Through this technique, the potato chips get sonicated during deep frying in hot oil. US-pretreatment at temperatures of 25 °C and 73 °C, along with US-assisted frying, resulted in the minimal amount of oil which may be due to the US creating potential pores during the pre-treatment phase, which then expand further during the subsequent sonication stage. UAFS in combination with US-pretreatment produced more crispy chips due to the fact that the texture of potato slices becomes more porous. UAFS resulted in a decrease in the moisture content of the fried chips attributed to an increase in the effective diffusion coefficient and mass. Pretreating the chips at 73 °C significantly reduce the color change producing brighter product by inactivation of enzymes such as polyphenol oxidase. Finally, the result of TOPSIS optimization based on potato chips properties confirms that US-pretreatment in 73 °C brine followed by frying using UAFS is the best approach. Scanning electron microscope (SEM) images of potato chips also support this issue.


Assuntos
Manipulação de Alimentos , Solanum tuberosum , Criança , Humanos , Adolescente , Manipulação de Alimentos/métodos , Culinária/métodos , Fenômenos Químicos , Ultrassonografia , Alimentos
12.
Nutrients ; 16(2)2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38257121

RESUMO

Caffeine is present in various foods and medicines and is highly accessible through various routes, regardless of age. However, most studies on caffeine have focused on the effects of high-dose caffeine ingestion based on the recommended daily amount for adults. In this study, we examined the physiological changes in the central and peripheral vessels that may occur when ingesting low-dose caffeine due to its high accessibility, with the aim of creating an environment of safe caffeine ingestion. This study included 26 healthy participants in their 20s. Peak systolic velocity (PSV), heart rate (HR), and pulse wave velocity (PWV) for vascular stiffness assessment were measured at 0, 30, and 60 min after caffeine ingestion using diagnostic ultrasound to determine the physiological changes in the blood vessels, common carotid artery (CCA) and radial artery (RA). In addition, percutaneous oxygen saturation (SpO2), blood pressure (BP), and accelerated photoplethysmography (APG) were measured. In comparison with before ingestion, the HR tended to decrease and showed a significant difference at 30 and 60 min (p = 0.014 and p = 0.031, respectively). PSV significantly decreased in both vessels at 30 and 60 min (p < 0.001 and p < 0.001, respectively). APG showed a decreasing trend until 60 min after ingestion, with a significant difference at 30 and 60 min (p = 0.003 and p = 0.012, respectively). No significant difference was observed in SpO2, BP, or PWV; however, they showed a tendency to increase after ingestion. Decreased HR may occur because of the baroreflex caused by an increase in BP. The RA has many branches and a smaller diameter; therefore, the PSV was lower in the RA than that in the CCA. This effect can occur because of the difficulty in the smooth expansion of blood vessels, which leads to a decrease in blood flow. In addition, an increase in intracellular calcium concentration can prevent vasodilation and increase the propagation velocity of pulse waves. The reflected waves can increase systolic blood pressure but reduce PWV and vascular elasticity. These results suggest that even low-dose caffeine can improve blood vessel health by providing temporary stimulation to the blood vessels; however, it can also cause changes in blood flow and blood vessel elasticity, which can lead to serious diseases such as stroke and high blood pressure. Therefore, caution should be exercised when caffeine consumption is indiscriminate.


Assuntos
Cafeína , Análise de Onda de Pulso , Adulto , Humanos , Ultrassonografia , Artéria Radial , Ingestão de Alimentos
13.
J Man Manip Ther ; 32(2): 166-172, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37574811

RESUMO

OBJECTIVES: The primary purpose of this study is to investigate the feasibility of using ultrasound to verify the placement of narrow-gauge dry needles within the supraspinatus and infraspinatus muscles utilizing palpation-based dry needle techniques. METHODS: This is a prospective observational study with 10 participants recruited. Each participant had a dry needle placed within the infraspinatus and supraspinatus muscles by a trained physical therapist utilizing palpation-based methods. Following needle placement, ultrasound examination was then performed to determine the feasibility of needle tip visualization within the targeted tissues. RESULTS: The needle tip was successfully visualized on ultrasound in 19/20 cases. The needle tip accurately resided in the targeted muscle tissue in each of the 19 cases it was successfully visualized. CONCLUSIONS: Narrow-gauge dry needles used in physical therapy practice can be consistently visualized in the supraspinatus and infraspinatus muscles using ultrasound imaging. Also, the palpation method utilized is an accurate means of guiding dry needles into the targeted rotator cuff muscles. These are significant findings because most physical therapy clinics do not have the benefit of real-time imaging guidance and must rely solely on palpation-based needling methods.


Assuntos
Indução Percutânea de Colágeno , Manguito Rotador , Humanos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/fisiologia , Estudos Prospectivos , Estudos de Viabilidade , Ultrassonografia
14.
Altern Ther Health Med ; 30(1): 24-30, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37773656

RESUMO

Objective: Exploring newer approaches to brachial plexus block is crucial for improving surgical outcomes and patient comfort. This study aims to review the application and research progress of ultrasound-guided brachial plexus block via the costoclavicular space approach in upper limb surgery. Methods: This study provides a comprehensive review of existing literature, studies, and clinical cases related to the costoclavicular approach. The advantages and disadvantages of conventional approaches for brachial plexus block, including the intermuscular groove method, supraclavicular method, and axillary approach, are discussed. The anatomical characteristics of the costoclavicular space are examined, and the methods of brachial plexus nerve block using ultrasound-guided costoclavicular space approach are described. It holds great promise for enhancing patient care and increasing the overall success rate of surgical procedures. Results: The costoclavicular space approach for brachial plexus block offers several advantages, including stable anatomical structure, low nerve variation rate, and clear visualization of each nerve bundle under ultrasound imaging. Compared to traditional approaches, ultrasound-guided brachial plexus block via the costoclavicular space approach has a high success rate, rapid onset of anesthesia, and high safety. Conclusion: Ultrasound-guided brachial plexus block via the costoclavicular space approach is effective and safe in upper limb surgery. It provides good anesthesia and postoperative analgesia, making it a valuable technique for various upper limb surgeries. The potential clinical significance of our findings lies in the possibility that ultrasound-guided costoclavicular space approach, with its enhanced precision and patient outcomes, could play a pivotal role in improving upper limb surgical procedures.


Assuntos
Bloqueio do Plexo Braquial , Humanos , Bloqueio do Plexo Braquial/métodos , Anestésicos Locais , Ultrassonografia de Intervenção/métodos , Ultrassonografia , Extremidade Superior/cirurgia
15.
Altern Ther Health Med ; 30(1): 226-231, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37773681

RESUMO

Objective: To assess the reliability of quantitative ultrasound (QUS) in diagnosing and screening osteoporosis in elder women. Methods: We conducted a systematic search of the online databases, including PubMed, Embase, Web of Science, and China National Knowledge, and screened the studies according to the inclusion criteria. We directly extract or calculate the value of true positive (TP), false positive (FP), false negative (FN), and true negative (TN) from eligible studies. We sought to evaluate the diagnostic parameters of QUS, containing the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC). Results: Twelve studies were included in this study with a total of 2260 women. QUS showed a pooled diagnostic odds ratio of 5.07 (95% CI 3.28-7.84), sensitivity of 0.69 (95% CI 0.65-0.72), specificity of 0.67 (95% CI 0.64-0.69), and an AUC of 0.7523 (Q*=0.6953). There was no obvious heterogeneity and threshold effect according to the Spearman correlation coefficient (P = 0.059). No significant publication bias was found through the Deek's funnel. Conclusion: Our study suggested that the diagnostic value of QUS for osteoporosis in elder women was acceptable, but the accuracy still needed to be improved, QUS can be recommended as a pre-screening tool for osteoporosis to determine whether DXA measurement was needed.


Assuntos
Osteoporose , Humanos , Feminino , Idoso , Curva ROC , Reprodutibilidade dos Testes , Ultrassonografia , Osteoporose/diagnóstico por imagem , China
16.
Ultrasound Obstet Gynecol ; 63(1): 9-14, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37470679

RESUMO

OBJECTIVE: To determine whether visual biofeedback can be used during labor as an effective tool for shortening the second stage of labor and reducing the need for instrumental delivery. METHODS: This was a single-center randomized controlled trial. Nulliparous women under epidural anesthesia were randomized at the point of full dilation into the biofeedback group (n = 50) or the control group (n = 50). Both groups received coached maternal pushing during four consecutive contractions, while an experienced obstetrician performed transperineal ultrasound. Only women in the biofeedback group observed the ultrasound display screen. Following this intervention, labor was managed routinely by the obstetric team. Angle of progression (AOP) was measured at rest and while pushing, before and during the first and fourth contractions. Second-stage duration and delivery outcomes were compared between groups. RESULTS: Visual biofeedback did not affect the duration of the second stage, which lasted for a median of 2.28 (interquartile range (IQR), 1.25-3.10) h in the biofeedback group vs 2.08 (IQR, 1.58-3.02) h in the control group (P = 0.981). AOP was significantly higher in the biofeedback group compared with the control group, both at rest before the fourth contraction (mean ± SD, 142.6° ± 15.9° vs 136.8° ± 13.1°; P = 0.049) and while pushing during the fourth contraction (mean ± SD, 159.3° ± 19.2° vs 149.4° ± 15.1°; P = 0.005). The increase in AOP was significantly higher in the biofeedback compared with the control group between rest and pushing at the last push (mean ± SD, 16.6° ± 11.0° vs 12.6° ± 8.3°; P = 0.041) and between the first rest and last push (mean ± SD, 24.4° ± 13.6° vs 17.9° ± 11.3°; P = 0.011). The rate of intact perineum was similar between groups (12% vs 8%; P = 0.505). CONCLUSIONS: Visual biofeedback during the second stage of labor may facilitate descent of fetal head during maternal pushing without affecting second-stage duration, possibly due to the short duration of the intervention. Future studies should focus on continuous intervention throughout the second stage of labor. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Parto Obstétrico , Segunda Fase do Trabalho de Parto , Gravidez , Feminino , Humanos , Estudos Prospectivos , Ultrassonografia , Biorretroalimentação Psicológica
17.
Pediatr Emerg Care ; 40(3): 239-242, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37890187

RESUMO

ABSTRACT: We discuss 10 cases where the qualitative evaluation of hard stool in the rectum with point-of-care ultrasound helped guide enema administration in a pediatric emergency department. Point-of-care ultrasound findings were especially valuable in cases where the presenting symptoms were undifferentiated, a language barrier was present, or the guardian and child denied that constipation was an active problem. When sodium phosphate enema administration was done in the pediatric emergency department, evacuation of the rectal stool burden was observed in most cases before final disposition.


Assuntos
Constipação Intestinal , Sistemas Automatizados de Assistência Junto ao Leito , Criança , Humanos , Constipação Intestinal/diagnóstico por imagem , Constipação Intestinal/terapia , Enema , Reto/diagnóstico por imagem , Ultrassonografia
18.
Chin J Integr Med ; 30(3): 203-212, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38051474

RESUMO

OBJECTIVE: To investigate a new noninvasive diagnostic model for nonalcoholic fatty liver disease (NAFLD) based on features of tongue images. METHODS: Healthy controls and volunteers confirmed to have NAFLD by liver ultrasound were recruited from China-Japan Friendship Hospital between September 2018 and May 2019, then the anthropometric indexes and sampled tongue images were measured. The tongue images were labeled by features, based on a brief protocol, without knowing any other clinical data, after a series of corrections and data cleaning. The algorithm was trained on images using labels and several anthropometric indexes for inputs, utilizing machine learning technology. Finally, a logistic regression algorithm and a decision tree model were constructed as 2 diagnostic models for NAFLD. RESULTS: A total of 720 subjects were enrolled in this study, including 432 patients with NAFLD and 288 healthy volunteers. Of them, 482 were randomly allocated into the training set and 238 into the validation set. The diagnostic model based on logistic regression exhibited excellent performance: in validation set, it achieved an accuracy of 86.98%, sensitivity of 91.43%, and specificity of 80.61%; with an area under the curve (AUC) of 0.93 [95% confidence interval (CI) 0.68-0.98]. The decision tree model achieved an accuracy of 81.09%, sensitivity of 91.43%, and specificity of 66.33%; with an AUC of 0.89 (95% CI 0.66-0.92) in validation set. CONCLUSIONS: The features of tongue images were associated with NAFLD. Both the 2 diagnostic models, which would be convenient, noninvasive, lightweight, rapid, and inexpensive technical references for early screening, can accurately distinguish NAFLD and are worth further study.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia , Antropometria , Algoritmos , China
19.
J Ultrasound Med ; 43(1): 137-150, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37873733

RESUMO

OBJECTIVES: Quantitative ultrasound (QUS) is a noninvasive imaging technique that can be used for assessing response to anticancer treatment. In the present study, tumor cell death response to the ultrasound-stimulated microbubbles (USMB) and hyperthermia (HT) treatment was monitored in vivo using QUS. METHODS: Human breast cancer cell lines (MDA-MB-231) were grown in mice and were treated with HT (10, 30, 50, and 60 minutes) alone, or in combination with USMB. Treatment effects were examined using QUS with a center frequency of 25 MHz (bandwidth range: 16 to 32 MHz). Backscattered radiofrequency (RF) data were acquired from tumors subjected to treatment. Ultrasound parameters such as average acoustic concentration (AAC) and average scatterer diameter (ASD), were estimated 24 hours prior and posttreatment. Additionally, texture features: contrast (CON), correlation (COR), energy (ENE), and homogeneity (HOM) were extracted from QUS parametric maps. All estimated parameters were compared with histopathological findings. RESULTS: The findings of our study demonstrated a significant increase in QUS parameters in both treatment conditions: HT alone (starting from 30 minutes of heat exposure) and combined treatment of HT plus USMB finally reaching a maximum at 50 minutes of heat exposure. Increase in AAC for 50 minutes HT alone and USMB +50 minutes was found to be 5.19 ± 0.417% and 5.91 ± 1.11%, respectively, compared to the control group with AAC value of 1.00 ± 0.44%. Furthermore, between the treatment groups, ΔASD-ENE values for USMB +30 minutes HT significantly reduced, depicting 0.00062 ± 0.00096% compared to 30 minutes HT only group, showing 0.0058 ± 0.0013%. Further, results obtained from the histological analysis indicated greater cell death and reduced nucleus size in both HT alone and HT combined with USMB. CONCLUSION: The texture-based QUS parameters indicated a correlation with microstructural changes obtained from histological data. This work demonstrated the use of QUS to detect HT treatment effects in breast cancer tumors in vivo.


Assuntos
Neoplasias da Mama , Hipertermia Induzida , Neoplasias Mamárias Animais , Humanos , Animais , Camundongos , Feminino , Microbolhas , Ultrassonografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Neoplasias da Mama/patologia , Terapia Combinada
20.
Artigo em Inglês | MEDLINE | ID: mdl-38096645

RESUMO

Endometriosis is a complex chronic inflammatory process characterised by the presence of endometrial-like glandular tissue outside the uterine cavity, typically within the pelvic structures. This condition affects up to 10-15 % of women and those assigned female at birth, and can result in chronic pelvic pain and in/subfertility. Treatment goals include medical, surgical options and alternative therapies. Transvaginal ultrasound (TVUS) is the currently recommended first line investigation for endometriosis with magnetic resonance imaging (MRI) reserved for those with equivocal ultrasound findings. In this paper, we aim to outline the commonly seen sonographic appearances of endometriosis divided into anterior, middle and posterior pelvic compartments. Limitations to ultrasound imaging include high operator dependence and patient factors. New imaging techniques and research into the utility of artificial intelligence (AI) into the detection of endometriosis is currently underway, with possibility of reduced diagnostic delay and better patient outcomes.


Assuntos
Endometriose , Infertilidade Feminina , Recém-Nascido , Feminino , Humanos , Endometriose/complicações , Endometriose/diagnóstico por imagem , Infertilidade Feminina/diagnóstico por imagem , Infertilidade Feminina/etiologia , Inteligência Artificial , Diagnóstico Tardio , Ultrassonografia/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA