Your browser doesn't support javascript.
loading
Simultaneous determination of six bioactive saponins from Rhizoma Panacis Japonici in rat plasma by UHPLC-MS/MS: Application to a pharmacokinetic study.
Zheng, Hong; Qiu, Feng; Zhao, Hui; Chen, Jie; Wang, Lei; Zou, Haiyan.
Affiliation
  • Zheng H; School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China; Beijing Key Lab of TCM Collateral Disease Theory Research, Beijing 100069, China.
  • Qiu F; School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China; Beijing Key Lab of TCM Collateral Disease Theory Research, Beijing 100069, China.
  • Zhao H; School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China; Beijing Key Lab of TCM Collateral Disease Theory Research, Beijing 100069, China.
  • Chen J; School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China; Beijing Key Lab of TCM Collateral Disease Theory Research, Beijing 100069, China.
  • Wang L; School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China; Beijing Key Lab of TCM Collateral Disease Theory Research, Beijing 100069, China. Electronic address: tmwangl@ccmu.edu.cn.
  • Zou H; School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China; Beijing Key Lab of TCM Collateral Disease Theory Research, Beijing 100069, China. Electronic address: zouhy@ccmu.edu.cn.
Article in En | MEDLINE | ID: mdl-29908469
A specific, sensitive and rapid ultra high performance liquid chromatography-tandem mass spectrometric (UHPLC-MS/MS) method was developed and validated for simultaneous determination of six major bioactive constituents in Rhizoma Panacis Japonici (RPJ), including oleanolic acid-type chikusetsusaponin V, IV, hemsgiganoside B, damarane-type ginsenoside Rb1, Rg1 and Re in rat plasma, using estazolam as the internal standard (IS). Plasma samples were pretreated with methanol/acetonitrile (1:1, V/V) for protein precipitation. Chromatographic separation was performed on an Agilent Eclipse Plus C18 column, using a gradient mobile phase consisting of methanol and 0.1% formic acid aqueous solution. A tandem mass spectrometric detection with an electrospray ionization (ESI) interface was conducted via multiple reaction monitoring (MRM) under positive ionization mode. For all the six analytes of interest, the calibration curves were linear in the concentration range of 2.00-500 ng/mL with r ≥ 0.9956. The intra- and inter-day precisions (in terms of relative standard deviation, RSD) were all below 10.2% and the accuracies (in terms of relative error, RE) were within -5.0% to 6.3% for all six analytes. Extraction recovery, matrix effect and stability data all met the acceptance criteria of FDA guideline for bioanalytical method validation. The developed method was applied to the pharmacokinetic study in rat. After oral administration of the total saponins from RPJ, six analytes were quickly absorbed into the blood and presented the phenomenon of double peaks. Among the six analytes, ginsenoside Rb1 showed slowest elimination from plasma with a t1/2z of 16.00 h, while that of the others were between 1.72 and 5.62 h. In conclusion, the developed method was successfully used to simultaneously analyze major oleanolic acid-type and damarane-type saponins of RPJ in rat plasma after oral administration.
Subject(s)
Key words

Full text: 1 Database: MEDLINE Traditional Medicines: Medicinas_tradicionales_de_asia / Medicina_china Main subject: Saponins / Triterpenes / Drugs, Chinese Herbal / Panax Type of study: Diagnostic_studies / Prognostic_studies Language: En Journal: J Chromatogr B Analyt Technol Biomed Life Sci Year: 2018 Type: Article Affiliation country: China

Full text: 1 Database: MEDLINE Traditional Medicines: Medicinas_tradicionales_de_asia / Medicina_china Main subject: Saponins / Triterpenes / Drugs, Chinese Herbal / Panax Type of study: Diagnostic_studies / Prognostic_studies Language: En Journal: J Chromatogr B Analyt Technol Biomed Life Sci Year: 2018 Type: Article Affiliation country: China