Your browser doesn't support javascript.
loading
Transcorporal artificial urinary sphincter in radiated and non - radiated compromised urethra. Assessment with a minimum 2 year follow-up
Long, Erwann Le; Rebibo, John David; Nouhaud, Francois Xavier; Grise, Philippe.
Afiliación
  • Long, Erwann Le; University Hospital-Charles Nicolle. Department of Urology-Rouen. Rouen. FR
  • Rebibo, John David; University Hospital-Charles Nicolle. Department of Urology-Rouen. Rouen. FR
  • Nouhaud, Francois Xavier; University Hospital-Charles Nicolle. Department of Urology-Rouen. Rouen. FR
  • Grise, Philippe; University Hospital-Charles Nicolle. Department of Urology-Rouen. Rouen. FR
Int. braz. j. urol ; 42(3): 494-500, tab, graf
Article en En | LILACS | ID: lil-785716
Biblioteca responsable: BR1.1
ABSTRACT
ABSTRACT Purpose to assess the efficacy of transcorporal artificial urinary sphincter (AUS) implantation on continence for male stress urinary incontinence in cases of prior surgical treatment or/and radiation failure, and as a first option in radiation patients. Materials and Methods From March 2007 to August 2012, 37 male patients were treated with transcorporal AUS AMS™ 800. Twelve patients had primary placement of transcorporal cuff, a surgical option due to a previous history of radiation and 25 patients had secondary procedure after failure of AUS or urinary incontinence surgery. Functional urinary outcomes were assessed by daily pad use, 24-hour Pad-test and ICIQ-SF questionnaire. Quality of life and satisfaction were assessed based on I-QoL and PGI-I questionnaires. Results After a median of 32 months, the continence rate (0 to 1 pad) was 69.7%. Median pad test was 17.5g (0-159), mean ICIQ-SF score was 7.3/21 (±5.4) and mean I-QoL score was 93.9/110. A total of 88% of the patients reported satisfaction with the AUS. The 5-year actuarial revision-free for AUS total device was 51%. Patients for primary implant for radiation were not more likely to experience revision than non-radiation patients. Preservation of erections was reported in half of the potent patients. Conclusions Transcorporal AUS cuff placement is a useful alternative procedure option for severe male UI treatment, especially in patients with a compromised urethra after prior surgery or radiation. A high continence rate was reported and implantation as first option in radiation patients should be considered.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: LILACS Asunto principal: Uretra / Incontinencia Urinaria de Esfuerzo / Esfínter Urinario Artificial Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies Idioma: En Revista: Int. braz. j. urol Año: 2016 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Bases de datos: LILACS Asunto principal: Uretra / Incontinencia Urinaria de Esfuerzo / Esfínter Urinario Artificial Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies Idioma: En Revista: Int. braz. j. urol Año: 2016 Tipo del documento: Article País de afiliación: Francia