Your browser doesn't support javascript.
loading
Balloon-occluded transarterial chemoembolization using a 1.8-French tip coaxial microballoon catheter for hepatocellular carcinoma: technical and safety considerations.
Matsumoto, Tomohiro; Endo, Jun; Hashida, Kazunobu; Ichikawa, Hitoshi; Kojima, Seiichiro; Takashimizu, Shinji; Watanabe, Norihito; Yamagami, Takuji; Hasebe, Terumitsu.
Afiliación
  • Matsumoto T; Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine , Tokyo , Japan.
Minim Invasive Ther Allied Technol ; 24(2): 94-100, 2015 Apr.
Article en En | MEDLINE | ID: mdl-25263680
ABSTRACT

OBJECTIVE:

To evaluate the technical feasibility and safety considerations of balloon-occluded transarterial chemoembolization (B-TACE) using a newly developed 1.8-French (Fr) tip microballoon catheter for hepatocellular carcinoma (HCC). MATERIAL AND

METHODS:

Between February 2013 and May 2013, 31 patients (20 males, 11 females; age range 56-85 years) underwent B-TACE using a 1.8-Fr tip microballoon catheter for unresectable HCC. The technical success rate, procedural complications, and adverse events of B-TACE were retrospectively investigated.

RESULTS:

A total of 31 patients were subjected to 70 sessions of B-TACE using a 1.8-Fr tip microballoon catheter. The level of B-TACE was sub-subsegmental in 11, subsegmental in 35, segmental in 14, lobar in five, and right inferior phrenic artery in five sessions. The overall technical success rate was 99% (69 out of 70 sessions). As procedural complications, rupturing of the microballoon (n = 3) and aneurysmal dilatation at the site of balloon occlusion (n = 2) were encountered. There were no significant differences in any parameters between blood biochemical examination before and between two to four weeks after the procedure.

CONCLUSION:

A 1.8-Fr tip microballoon catheter enables selective catheterization in patients with HCC and B-TACE using the 1.8-Fr tip microballoon catheter is a safe procedure.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Quimioembolización Terapéutica / Carcinoma Hepatocelular / Oclusión con Balón / Neoplasias Hepáticas / Antineoplásicos Tipo de estudio: Observational_studies Idioma: En Revista: Minim Invasive Ther Allied Technol Año: 2015 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Quimioembolización Terapéutica / Carcinoma Hepatocelular / Oclusión con Balón / Neoplasias Hepáticas / Antineoplásicos Tipo de estudio: Observational_studies Idioma: En Revista: Minim Invasive Ther Allied Technol Año: 2015 Tipo del documento: Article País de afiliación: Japón