Your browser doesn't support javascript.
loading
New magnetic graphene-based inorganic-organic sol-gel hybrid nanocomposite for simultaneous analysis of polar and non-polar organophosphorus pesticides from water samples using solid-phase extraction.
Rashidi Nodeh, Hamid; Wan Ibrahim, Wan Aini; Kamboh, Muhammad Afzal; Sanagi, Mohd Marsin.
Afiliación
  • Rashidi Nodeh H; Separation Science and Technology Group, Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM, Johor Bahru, Johor, Malaysia.
  • Wan Ibrahim WA; Separation Science and Technology Group, Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM, Johor Bahru, Johor, Malaysia; Centre for Sustainable Nanomaterials, Ibnu Sina Institute for Scientific and Industrial Research, Universiti Teknologi Malaysia, 81310 UTM, Jo
  • Kamboh MA; Separation Science and Technology Group, Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM, Johor Bahru, Johor, Malaysia.
  • Sanagi MM; Separation Science and Technology Group, Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM, Johor Bahru, Johor, Malaysia; Centre for Sustainable Nanomaterials, Ibnu Sina Institute for Scientific and Industrial Research, Universiti Teknologi Malaysia, 81310 UTM, Jo
Chemosphere ; 166: 21-30, 2017 Jan.
Article en En | MEDLINE | ID: mdl-27681257
A new graphene-based tetraethoxysilane-methyltrimethoxysilane sol-gel hybrid magnetic nanocomposite (Fe3O4@G-TEOS-MTMOS) was synthesised, characterized and successfully applied in magnetic solid-phase extraction (MSPE) for simultaneous analysis of polar and non-polar organophosphorus pesticides from several water samples. The Fe3O4@G-TEOS-MTMOS nanocomposite was characterized using Fourier transform-infrared spectroscopy, energy-dispersive X-ray spectroscopy, field emission scanning electron microscopy and X-ray diffraction. Separation, determination and quantification were achieved using gas chromatography coupled with micro electron capture detector. Adsorption capacity of the sorbent was calculated using Langmuir equation. MSPE was linear in the range 100-1000 pg mL-1 for phosphamidon and dimethoate, and 10-100 pg mL-1 for chlorpyrifos and diazinon, with limit of detection (S/N = 3) of 19.8, 23.7, 1.4 and 2.9 pg mL-1 for phosphamidon, dimethoate, diazinon and chlorpyrifos, respectively. The LODs obtained is well below the maximum residual level (100 pg mL-1) as set by European Union for pesticides in drinking water. Acceptable precision (%RSD) was achieved for intra-day (1.3-8.7%, n = 3) and inter-day (7.6-17.8%, n = 15) analyses. Fe3O4@G-TEOS-MTMOS showed high adsorption capacity (54.4-76.3 mg g-1) for the selected OPPs. No pesticide residues were detected in the water samples analysed. Excellent extraction recoveries (83-105%) were obtained for the spiked OPPs from tap, river, lake and sea water samples. The newly synthesised Fe3O4@G-TEOS-MTMOS showed high potential as adsorbent for OPPs analysis.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Plaguicidas / Residuos de Plaguicidas / Extracción en Fase Sólida / Nanocompuestos / Grafito / Magnetismo Idioma: En Revista: Chemosphere Año: 2017 Tipo del documento: Article País de afiliación: Malasia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Plaguicidas / Residuos de Plaguicidas / Extracción en Fase Sólida / Nanocompuestos / Grafito / Magnetismo Idioma: En Revista: Chemosphere Año: 2017 Tipo del documento: Article País de afiliación: Malasia