Your browser doesn't support javascript.
loading
[Comparative ultrasound study of gastric emptying between an isotonic solution and a nutritional supplement]. / Estudo comparativo do esvaziamento gástrico entre uma solução isotônica e um suplemento nutricional por meio da ultrassonografia.
Bisinotto, Flora Margarida Barra; Silveira, Luciano Alves Matias da; Rossi, Tiago Caneu; Martins, Laura Bisinotto; Zago, Gustavo Palis; Mendonça, Mariana Andrade Lopes.
Afiliación
  • Bisinotto FMB; Universidade Estadual Paulista (Unesp), Departamento de Anestesiologia, São Paulo, SP, Brasil; Universidade Federal do Triângulo Mineiro (UFTM), Departamento de Cirurgia, Uberaba, MG, Brasil.
  • Silveira LAMD; Universidade Federal do Triângulo Mineiro (UFTM), Departamento de Cirurgia, Uberaba, MG, Brasil; Universidade Federal do Triângulo Mineiro (UFTM), Instituto de Ciências Biológicas e Naturais, Uberaba, MG, Brasil. Electronic address: drluciano@hotmail.com.
  • Rossi TC; Universidade Federal do Triângulo Mineiro (UFTM), Centro de Ensino e Treinamento do Hospital de Clínicas (CET/SBA/HC), Departamento de Anestesiologia, Uberaba, MG, Brasil.
  • Martins LB; Universidade Federal do Triângulo Mineiro (UFTM), Centro de Ensino e Treinamento do Hospital de Clínicas (CET/SBA/HC), Departamento de Anestesiologia, Uberaba, MG, Brasil.
  • Zago GP; Universidade Federal do Triângulo Mineiro (UFTM), Centro de Ensino e Treinamento do Hospital de Clínicas (CET/SBA/HC), Departamento de Anestesiologia, Uberaba, MG, Brasil.
  • Mendonça MAL; Universidade Federal do Triângulo Mineiro (UFTM), Faculdade de Medicina, Uberaba, MG, Brasil.
Braz J Anesthesiol ; 69(2): 115-121, 2019.
Article en Pt | MEDLINE | ID: mdl-30528849
BACKGROUND AND OBJECTIVES: Preoperative fasting may lead to undesirable effects in the surgical patient in whom there is a stimulus to ingesting clear liquids until 2hours before anesthesia. The aim of this study was to evaluate the gastric emptying of two different solutions using ultrasound. METHODS: In a prospective, randomized, blind study, 34 healthy volunteers ingested 200mL of two solutions without residues in two steps: an isotonic solution with carbohydrates, electrolytes, osmolarity of 292 mOsm.L-1, and 36 kcal; and other nutritional supplementation with carbohydrates, proteins, electrolytes, osmolarity of 680 mO.L-1, and 300 kcal. After 2hours, a gastric ultrasound was performed to assess the antrum area and gastric volume, and the relation of gastric volume to weight (vol.w-1), whose value above 1.5mL.kg-1 was considered a risk for bronchoaspiration. A p-value <0.05 was considered statistically significant. RESULTS: There was a significant difference between all parameters evaluated 2hours after the ingestion of nutritional supplementation compared to fasting. The same occurred when the parameters between isotonic solution and nutritional supplementation were compared 2hours after ingestion. Only one patient had vol.w-1 <1.5mL.kg-1 2hours after ingestion of nutritional supplementation; and only one had vol.w-1> 1.5mL.kg-1 after ingestion of isotonic solution. CONCLUSION: This study demonstrated that gastric emptying of equal volumes of different solutions depends on their constitution. Those with high caloric and high osmolarity, and with proteins present, 2hours after ingestion, increased the gastric volumes, which is compatible with the risk of gastric aspiration.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ultrasonografía / Suplementos Dietéticos / Vaciamiento Gástrico / Soluciones Isotónicas Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Risk_factors_studies Idioma: Pt Revista: Braz J Anesthesiol Año: 2019 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ultrasonografía / Suplementos Dietéticos / Vaciamiento Gástrico / Soluciones Isotónicas Tipo de estudio: Clinical_trials / Diagnostic_studies / Observational_studies / Risk_factors_studies Idioma: Pt Revista: Braz J Anesthesiol Año: 2019 Tipo del documento: Article País de afiliación: Brasil