Your browser doesn't support javascript.
loading
Visualization of thermal washout due to spatiotemporally heterogenous perfusion in the application of a model-based control algorithm for MR-HIFU mediated hyperthermia.
Sebeke, Lukas Christian; Rademann, Pia; Maul, Alexandra Claudia; Yeo, Sin Yuin; Castillo Gómez, Juan Daniel; Deenen, Daniel A; Schmidt, Patrick; de Jager, Bram; Heemels, W P M H; Grüll, Holger; Heijman, Edwin.
Afiliación
  • Sebeke LC; University of Cologne, Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, Cologne, Germany.
  • Rademann P; Eindhoven University of Technology, Department of Biomedical Engineering, Eindhoven, The Netherlands.
  • Maul AC; University of Cologne, Faculty of Medicine and University Hospital of Cologne, Experimental Medicine, Cologne, Germany.
  • Yeo SY; University of Cologne, Faculty of Medicine and University Hospital of Cologne, Experimental Medicine, Cologne, Germany.
  • Castillo Gómez JD; University of Cologne, Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, Cologne, Germany.
  • Deenen DA; Profound Medical GmbH, Hamburg, Germany.
  • Schmidt P; University of Cologne, Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, Cologne, Germany.
  • de Jager B; Eindhoven University of Technology, Department of Mechanical Engineering, Control Systems Technology, Eindhoven, The Netherlands.
  • Heemels WPMH; University of Cologne, Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, Cologne, Germany.
  • Grüll H; Eindhoven University of Technology, Department of Mechanical Engineering, Control Systems Technology, Eindhoven, The Netherlands.
  • Heijman E; Eindhoven University of Technology, Department of Mechanical Engineering, Control Systems Technology, Eindhoven, The Netherlands.
Int J Hyperthermia ; 38(1): 1174-1187, 2021.
Article en En | MEDLINE | ID: mdl-34374624

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ultrasonido Enfocado de Alta Intensidad de Ablación / Hipertermia Inducida Tipo de estudio: Prognostic_studies Idioma: En Revista: Int J Hyperthermia Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Ultrasonido Enfocado de Alta Intensidad de Ablación / Hipertermia Inducida Tipo de estudio: Prognostic_studies Idioma: En Revista: Int J Hyperthermia Año: 2021 Tipo del documento: Article País de afiliación: Alemania