Your browser doesn't support javascript.
loading
Using cross-correlation analysis of multi-channel near infrared spectroscopy to assess the hemodynamic response to cupping therapy.
Liau, Ben-Yi; Lung, Chi-Wen; Hernandez, Manuel E; Mo, Pu-Chun; Li, Yameng; Guo, Jiaqi; Jan, Yih-Kuen.
Afiliación
  • Liau BY; Department of Automatic Control Engineering, Feng Chia University, Taichung, Taiwan.
  • Lung CW; Rehabilitation Engineering Lab, Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
  • Hernandez ME; Department of Creative Product Design, Asia University, Taichung, Taiwan.
  • Mo PC; Department of Biomedical and Translational Sciences, Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
  • Li Y; Rehabilitation Engineering Lab, Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
  • Guo J; Rehabilitation Engineering Lab, Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
  • Jan YK; Rehabilitation Engineering Lab, Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
Biomed Opt Express ; 14(9): 4455-4467, 2023 Sep 01.
Article en En | MEDLINE | ID: mdl-37791272
ABSTRACT
Cupping therapy is a common intervention for the management of musculoskeletal impairment. Previous studies have demonstrated that cupping therapy can improve muscle hemodynamic responses using single-channel near-infrared spectroscopy (NIRS). However, the effects of cupping therapy on spatial hemodynamic responses as well as the correlation between oxyhemoglobin and deoxy-hemoglobin are largely unknown. The cross-correlation function (CCF) algorithm was used to determine the correlation between time-series NIRS signals from inside and outside the cup as well as time-series oxyhemoglobin and deoxy-hemoglobin under 4 cupping intensities, including -225 and -300 mmHg for 5 and 10 min. The main finding was that the maximum CCF values of oxyhemoglobin was significantly higher than those in deoxy-hemoglobin (p < 0.05). Furthermore, it was found that there was a correlation between deoxy-hemoglobin with a longer duration and a larger magnitude of negative pressure. This is the first study investigating time-series hemodynamic responses after cupping therapy using cross-correlation function analysis of multi-channel NIRS signals.

Texto completo: 1 Bases de datos: MEDLINE Medicinas Tradicionales: Medicinas_tradicionales_de_asia / Medicina_china Métodos Terapéuticos y Terapias MTCI: Terapias_energeticas / Ventosas Idioma: En Revista: Biomed Opt Express Año: 2023 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Bases de datos: MEDLINE Medicinas Tradicionales: Medicinas_tradicionales_de_asia / Medicina_china Métodos Terapéuticos y Terapias MTCI: Terapias_energeticas / Ventosas Idioma: En Revista: Biomed Opt Express Año: 2023 Tipo del documento: Article País de afiliación: Taiwán