Auditory magnetic responses of healthy newborns.
Neuroreport
; 14(14): 1871-5, 2003 Oct 06.
Article
em En
| MEDLINE
| ID: mdl-14534438
We recorded magnetic brain activity from healthy human newborns when they heard frequency changes in an otherwise repetitive sound stream. We were able to record the magnetic counterpart of the mismatch negativity (MMN) previously described only with electric recordings in infants. The results show that these recordings are possible, although still challenging due to the small head size and head movements. The modelling of the neural sources underlying the recorded responses suggests cortical sources in the temporal lobes.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Lobo Temporal
/
Magnetoencefalografia
/
Campos Eletromagnéticos
Idioma:
En
Revista:
Neuroreport
Ano de publicação:
2003
Tipo de documento:
Article
País de afiliação:
Finlândia