Your browser doesn't support javascript.
loading
Evaluation of image quality in portal imaging using a combination of a storage phosphor plate and diagnostic cassette.
Fujita, H; Yamaguchi, M; Fujioka, T; Fukuda, H; Murase, K.
Afiliação
  • Fujita H; Department of Radiology, Osaka Prefectural Medical Center for Respiratory and Allergic Diseases, Osaka, Japan. hima71f@zeus.eonet.ne.jp
Br J Radiol ; 82(978): 504-8, 2009 Jun.
Article em En | MEDLINE | ID: mdl-19153183
ABSTRACT
It is useful to utilise a computed radiography system with a combination of storage phosphor plates and therapy cassettes for portal images. However, the therapy cassette has some disadvantages. The objective of the present study was to determine whether the disadvantages of a diagnostic cassette could be overcome to obtain clinically useful portal images. A storage phosphor plate has 0.3 mm of lead foil on the distal surface to reduce backscattered radiation. When the plate is reversed, the lead foil acts as a front intensifying screen, similar to the metal plate of a therapy cassette. We reversed a combination of the diagnostic cassette and storage phosphor plate and obtained portal images of the contrast-detail phantom and the Rando phantom (The Phantom Laboratory, Salem, NY) using three types of cassettes a reversed diagnostic cassette, a therapy cassette and a diagnostic cassette. The image quality was subjectively evaluated. The Friedman and Wilcoxon tests were applied for statistical analyses. Evaluation of images for the contrast-detail phantom revealed that the reversed diagnostic cassette was inferior to the therapy cassette and superior to the diagnostic cassette, and that the differences were significant (p<0.017). There was no significant difference between the reversed diagnostic cassette and therapy cassette (p>0.05) for the Rando phantom. Portal images obtained using the reversed diagnostic cassette were of sufficiently high quality for clinical use as determined by Rando phantom studies.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fósforo / Ecrans Intensificadores para Raios X / Aumento da Imagem Tipo de estudo: Diagnostic_studies / Evaluation_studies Idioma: En Revista: Br J Radiol Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fósforo / Ecrans Intensificadores para Raios X / Aumento da Imagem Tipo de estudo: Diagnostic_studies / Evaluation_studies Idioma: En Revista: Br J Radiol Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Japão