Your browser doesn't support javascript.
loading
Evaluation of marginal and internal fit of ceramic and metallic crown copings using x-ray microtomography (micro-CT) technology.
Pimenta, Manuel Antonio; Frasca, Luis Carlos; Lopes, Ricardo; Rivaldo, Elken.
Afiliação
  • Pimenta MA; Professor, Department of Prosthodontics, Federal University of Santa Maria, Santa Maria, Brazil.
  • Frasca LC; Professor, Department of Prosthodontics, Federal University of Rio Grande do Sul, Porto Alegre, Brazil.
  • Lopes R; Professor, Department of Nuclear Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
  • Rivaldo E; Professor, Postgraduate Program in Dentistry, Lutheran University of Brazil, Canoas, Brazil. Electronic address: elkenrivaldo@gmail.com.
J Prosthet Dent ; 114(2): 223-8, 2015 Aug.
Article em En | MEDLINE | ID: mdl-25882975
ABSTRACT
STATEMENT OF

PROBLEM:

Prosthetic crown fit to the walls of the tooth preparation may vary depending on the material used for crown fabrication.

PURPOSE:

The purpose of this study was to compare the marginal and internal fit of crown copings fabricated from 3 different materials. MATERIAL AND

METHODS:

The selected materials were zirconia (ZirkonZahn system, group Y-TZP), lithium disilicate (IPS e.max Press system, group LSZ), and nickel-chromium alloy (lost-wax casting, group NiCr). Five specimens of each material were seated on standard dies. An x-ray microtomography (micro-CT) device was used to obtain volumetric reconstructions of each specimen. Points for fit measurement were located in Adobe Photoshop, and measurements were obtained in the CTAn SkyScan software environment. Marginal fit was measured at 4 points and internal fit at 9 points in each coping. Mean measurements from the 3 groups were compared by analysis of variance (ANOVA) at the 5% significance level, and between-group differences were assessed with the Tukey range test.

RESULTS:

The nickel-chromium alloy exhibited the best marginal fit overall, comparable with zirconia and significantly different from lithium disilicate. Lithium disilicate exhibited the lowest mean values for internal fit, similar to zirconia and significantly different from the nickel-chrome alloy.

CONCLUSIONS:

The marginal and internal fit parameters of the 3 tested materials were within clinically acceptable range.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cerâmica / Ligas de Cromo / Adaptação Marginal Dentária / Coroas / Materiais Dentários / Microtomografia por Raio-X Idioma: En Revista: J Prosthet Dent Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cerâmica / Ligas de Cromo / Adaptação Marginal Dentária / Coroas / Materiais Dentários / Microtomografia por Raio-X Idioma: En Revista: J Prosthet Dent Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil