Your browser doesn't support javascript.
loading
Dynamic microwave-assisted extraction online coupled with single drop microextraction of organophosphorus pesticides in tea samples.
Wu, Lijie; Hu, Mingzhu; Li, Zhanchao; Song, Ying; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming.
Afiliação
  • Wu L; College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun, 130012, China.
  • Hu M; College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun, 130012, China.
  • Li Z; College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun, 130012, China.
  • Song Y; College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun, 130012, China.
  • Zhang H; College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun, 130012, China.
  • Yu A; College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun, 130012, China.
  • Ma Q; Chinese Academy of Inspection and Quarantine, Beijing, 100123, China.
  • Wang Z; College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun, 130012, China. Electronic address: wangziming@jlu.edu.cn.
J Chromatogr A ; 1407: 42-51, 2015 Aug 14.
Article em En | MEDLINE | ID: mdl-26166295
ABSTRACT
A new method for the determination of seven organophosphorus pesticides was developed using dynamic microwave-assisted extraction online coupled with single drop microextraction prior to gas chromatographic mass spectrometry (GC-MS). The method combines the advantages of dynamic microwave-assisted extraction and single-drop microextraction, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, tea samples were extracted with 25% ethanol aqueous solution and purified with acidic alumina at the same time, and then the analytes were concentrated into microextraction solvent. When the extraction was completed, the solvent microdrop containing the enriched analytes was retracted into the microsyringe and directly analyzed by GC-MS without any filtration or cleanup step. The method makes extraction, cleanup, separation, and enrichment to be carried out in one step. Several experimental parameters, including type of extraction solvent, type and amount of dispersant, type and volume of microextraction solvent, microwave power, extraction time, and flow rate of extraction solvent were investigated and optimized. Under optimal experimental conditions, good linearity was observed in the range of 2.00-500.00 µg kg(-1). The limits of detection and quantification were in the range of 0.4-1.7 µg kg(-1) and 1.1-5.6 µg kg(-1), respectively. The present method was applied to the analysis of tea samples, and the recoveries of analytes were in the range of 84.9-106.4% with the relative standard deviations ranging from 1.0 to 6.1%. The results showed that the present method was a rapid and feasible method for the determination of organophosphorus pesticides in tea samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Praguicidas / Chá / Análise de Alimentos / Micro-Ondas Idioma: En Revista: J Chromatogr A Ano de publicação: 2015 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Praguicidas / Chá / Análise de Alimentos / Micro-Ondas Idioma: En Revista: J Chromatogr A Ano de publicação: 2015 Tipo de documento: Article País de afiliação: China