Your browser doesn't support javascript.
loading
Simultaneous analysis of tert-butylhydroquinone, tert-butylquinone, butylated hydroxytoluene, 2-tert-butyl-4-hydroxyanisole, 3-tert-butyl-4-hydroxyanisole, α-tocopherol, γ-tocopherol, and δ-tocopherol in edible oils by normal-phase high performance liquid chromatography.
Li, Jun; Bi, Yanlan; Sun, Shangde; Peng, Dan.
Afiliação
  • Li J; Lipid Technology and Engineering, School of Food Science and Engineering, Henan University of Technology, Lianhua Road, Zhengzhou, Henan 450001, People's Republic of China. Electronic address: lijun1989730@163.com.
  • Bi Y; Lipid Technology and Engineering, School of Food Science and Engineering, Henan University of Technology, Lianhua Road, Zhengzhou, Henan 450001, People's Republic of China. Electronic address: yanlanbi@hotmail.com.
  • Sun S; Lipid Technology and Engineering, School of Food Science and Engineering, Henan University of Technology, Lianhua Road, Zhengzhou, Henan 450001, People's Republic of China. Electronic address: sunshangde@hotmail.com.
  • Peng D; Lipid Technology and Engineering, School of Food Science and Engineering, Henan University of Technology, Lianhua Road, Zhengzhou, Henan 450001, People's Republic of China. Electronic address: pengdantju@163.com.
Food Chem ; 234: 205-211, 2017 Nov 01.
Article em En | MEDLINE | ID: mdl-28551227
A normal-phase high performance liquid chromatography method for the simultaneous determination of tert-butylhydroquinone, tert-butylquinone, butylated hydroxytoluene, 2-tert-butyl-4-hydroxyanisole, 3-tert-butyl-4-hydroxyanisole, α-tocopherol, γ-tocopherol, and δ-tocopherol in edible oils was investigated. A silica column was used to separate the analytes with the gradient elution. An ultraviolet-visible detector was set at dual wavelengths mode (280 and 310nm). The column temperature was 30°C. The analytes were directly extracted with methanol. Results showed that the normal-phase high performance liquid chromatography method performed well with wide liner ranges (0.10∼500.00µg/mL, R2>0.9998), low limits of detection and quantitation (below 0.40 and 1.21µg/mL, respectively), and good recoveries (81.38∼102.34% in soybean oils and 83.03∼100.79% in lard, respectively). The reduction of tert-butylquinone caused by the reverse-phase high performance liquid chromatography during the injection was avoided with the current normal-phase method. The two isomers of butylated hydroxyanisole can also be separated with good resolution.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Quinonas / Óleos de Plantas / Hidroxianisol Butilado / Hidroxitolueno Butilado / Tocoferóis Idioma: En Revista: Food Chem Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Quinonas / Óleos de Plantas / Hidroxianisol Butilado / Hidroxitolueno Butilado / Tocoferóis Idioma: En Revista: Food Chem Ano de publicação: 2017 Tipo de documento: Article