Reliability of the Cervical Spine Device for the Assessment of Cervical Spine Range of Motion in Asymptomatic Participants.
Mangone, Massimiliano; Bernetti, Andrea; Germanotta, Marco; Di Sipio, Enrica; Razzano, Cristina; Ioppolo, Francesco; Santilli, Valter; Venditto, Teresa; Paoloni, Marco.
Afiliação
  • Mangone M; Department of Anatomical, Histological, Forensic Medicine and Orthopedic Science, Sapienza University of Rome, Rome, Italy.
  • Bernetti A; Department of Anatomical, Histological, Forensic Medicine and Orthopedic Science, Sapienza University of Rome, Rome, Italy.
  • Germanotta M; Don Gnocchi Foundation, Milan, Italy.
  • Di Sipio E; Don Gnocchi Foundation, Milan, Italy.
  • Razzano C; Department of Anatomical, Histological, Forensic Medicine and Orthopedic Science, Sapienza University of Rome, Rome, Italy.
  • Ioppolo F; Department of Anatomical, Histological, Forensic Medicine and Orthopedic Science, Sapienza University of Rome, Rome, Italy.
  • Santilli V; Department of Anatomical, Histological, Forensic Medicine and Orthopedic Science, Sapienza University of Rome, Rome, Italy.
  • Venditto T; Neuromotor Rehabilitation Hospital Service, Policlinico Italia Srl, Rome, Italy.. Electronic address: teresa.venditto@hotmail.it.
  • Paoloni M; Department of Anatomical, Histological, Forensic Medicine and Orthopedic Science, Sapienza University of Rome, Rome, Italy.
J Manipulative Physiol Ther ; 41(4): 342-349, 2018 05.
Article em En | MEDLINE | ID: mdl-29751851
OBJECTIVE: The purpose of this study was to assess the inter- and intra-assessor reliability of the cervical spine device (Formetric, DIERS International GmbH, Schlangenbad, Germany) in measuring cervical range of motion. METHODS: The cervical spine device was used to measure the cervical range of motion of 65 asymptomatic participants. Flexion-extension, right and left rotation, and right and left lateral flexion were analyzed. Two different assessors performed the measurements on the same day to estimate inter-assessor reliability and 2 days later to examine intra-assessor reliability. Intra-assessor and inter-assessor reliability was assessed using the intraclass correlation coefficient (ICC). The standard error of measurement (SEM) and the smallest detectable difference (SDD) were also estimated. RESULTS: Inter-assessor reliability ICCs for flexion + extension and total lateral flexion movements were >0.90. The ICCs for rotation movements and for left lateral flexion were >0.70. The ICCs for flexion (0.64), extension (0.58), and right lateral flexion (0.56) indicated moderate correlation. Mean SEMs ranged from 2.28° (SDD = 6.31°) for left rotation to 8.08° (SDD = 22.38°) for total rotation. As for intra-assessor test-retest reliability, all ICCs were >0.70. Mean SEMs ranged from 3.14° (SDD = 8.70°) for total lateral flexion to 7.50° (SDD = 20.77°) for extension. CONCLUSION: Both inter- and intra-observer reproducibility correlation values are moderate to high for measurements obtained using the cervical spine device.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Medição da Dor / Amplitude de Movimento Articular / Especialidade de Fisioterapia Tipo de estudo: Evaluation_studies Idioma: En Revista: J Manipulative Physiol Ther Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Medição da Dor / Amplitude de Movimento Articular / Especialidade de Fisioterapia Tipo de estudo: Evaluation_studies Idioma: En Revista: J Manipulative Physiol Ther Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Itália