Your browser doesn't support javascript.
loading
Analysis of Pulse Signals Based on Array Pulse Volume.
Cui, Ji; Tu, Li-Ping; Zhang, Jian-Feng; Zhang, Shao-Liang; Zhang, Zhi-Feng; Xu, Jia-Tuo.
Afiliação
  • Cui J; School of Basic Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China.
  • Tu LP; Interdisciplinary Science Institute, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China.
  • Zhang JF; School of Basic Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China.
  • Zhang SL; School of Basic Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China.
  • Zhang ZF; School of Basic Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China.
  • Xu JT; School of Basic Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China. xjt@fudan.edu.cn.
Chin J Integr Med ; 25(2): 103-107, 2019 Feb.
Article em En | MEDLINE | ID: mdl-29790062
ABSTRACT

OBJECTIVE:

To collect and analyze multi-dimensional pulse diagram features with the array sensor of a pressure profile system (PPS) and study the characteristic parameters of the new multi-dimensional pulse diagram by pulse diagram analysis technology.

METHODS:

The pulse signals at the Guan position of left wrist were acquired from 105 volunteers at the Shanghai University of Traditional Chinese Medicine. We obtained the pulse data using an array sensor with 3×4 channels. Three dimensional pulse diagrams were constructed for the validated pulse data, and the array pulse volume (APV) parameter was computed by a linear interpolation algorithm. The APV differences among normal pulse (NP), wiry pulse (WP) and slippery pulse (SP) were analyzed using one-way analysis of variance. The coefficients of variation (CV) were calculated for WP, SP and NP.

RESULTS:

The APV difference between WP and NP in the 105 volunteers was statistically significant (6.26±0.28 vs. 6.04±0.36, P=0.048), as well as the difference between WP and SP (6.26±0.28 vs. 6.07±0.46, P=0.049). However, no statistically significant difference was found between NP and SP (P=0.75). WP showed a similar CV (4.47%) to those of NP (5.96%) and SP (7.58%).

CONCLUSION:

The new parameter APV could differentiate between NP or SP and WP. Accordingly, APV could be considered an useful parameter for the analysis of array pulse diagrams in Chinese medicine.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Medicinas Tradicionais: Medicinas_tradicionales_de_asia / Medicina_china Assunto principal: Pulso Arterial / Processamento de Sinais Assistido por Computador Idioma: En Revista: Chin J Integr Med Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Medicinas Tradicionais: Medicinas_tradicionales_de_asia / Medicina_china Assunto principal: Pulso Arterial / Processamento de Sinais Assistido por Computador Idioma: En Revista: Chin J Integr Med Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China