Your browser doesn't support javascript.
loading
Zero-fluoroscopy transseptal puncture guided by right atrial electroanatomical mapping combined with intracardiac echocardiography: A single-center experience.
Zhang, Guangping; Cheng, Liting; Liang, Zhuo; Zhang, Junmeng; Dong, Ruiqing; Hang, Fei; Wang, Xinlu; Wang, Ziyu; Zhao, Lin; Wang, Zefeng; Wu, Yongquan.
Afiliação
  • Zhang G; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Cheng L; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Liang Z; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Zhang J; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Dong R; Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Hang F; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Wang X; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Wang Z; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Zhao L; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Wang Z; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Wu Y; Department of Lung and Blood Vessel Disease, Beijing Institute of Heart, Beijing, China.
Clin Cardiol ; 43(9): 1009-1016, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32506504
ABSTRACT

BACKGROUND:

Right atrial electroanatomical mapping may be combined with SoundStar 3D diagnostic ultrasound catheter (EAM-ICE) as a zero-fluoroscopy procedure for radiofrequency catheter ablation (RFCA). We aimed to evaluate the efficiency and safety of zero-fluoroscopy transseptal puncture guided by EAM-ICE and fluoroscopy combined with intracardiac echocardiography (F-ICE) in patients with paroxysmal atrial fibrillation (PAF).

HYPOTHESIS:

Zero-fluoroscopy transseptal puncture is an effective and safe procedure.

METHODS:

This study had a prospective design. A total of 57 patients with PAF were enrolled and assigned to two groups. Twenty-seven patients were enrolled in the EAM-ICE group, and 30 patients were enrolled in the F-ICE group.

RESULTS:

There were no statistically significant differences in baseline patient characteristics between groups. Transseptal puncture was successful in all patients (57/57, 100%). Total procedure time and duration of transseptal puncture were lower in the F-ICE group (199.4 ± 26.0 minutes vs 150.7 ± 22.1 minutes, P = 0.000; 118.4 ± 19.7 vs 70.5 ± 13.5 minutes, P = 0.000). There was no use of fluoroscopy in the EAM-ICE group (0 mGy vs 70.5 ± 13.5 mGy); the duration of fluoroscopy in the EAM-ICE group was negligible (0 minutes vs 5.4 ± 1.9 minutes). No procedural complication occurred in either group.

CONCLUSIONS:

EAM-ICE guided zero-fluoroscopy transseptal puncture is an effective and safe procedure.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ecocardiografia / Cateterismo Cardíaco / Ablação por Cateter / Técnicas Eletrofisiológicas Cardíacas / Septo Interatrial Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies / Risk_factors_studies País/Região como assunto: Asia Idioma: En Revista: Clin Cardiol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ecocardiografia / Cateterismo Cardíaco / Ablação por Cateter / Técnicas Eletrofisiológicas Cardíacas / Septo Interatrial Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies / Risk_factors_studies País/Região como assunto: Asia Idioma: En Revista: Clin Cardiol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China