Your browser doesn't support javascript.
loading
Separation performance of the copolymer and homopolymer of aliphatic polycarbonate diols as the stationary phases for capillary gas chromatography.
Shi, Yingying; Qi, Meiling.
Afiliação
  • Shi Y; Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing, 100081, China.
  • Qi M; Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing, 100081, China. Electronic address: mlqi@bit.edu.cn.
J Chromatogr A ; 1649: 462223, 2021 Jul 19.
Article em En | MEDLINE | ID: mdl-34038781
ABSTRACT
This work presents the investigation of two aliphatic polycarbonate diols (CAPC and HAPC) as the stationary phases for capillary gas chromatography (GC). The CAPC and HAPC capillary columns showed moderate polarity and high column efficiency of 3704 - 4545 plates/m measured by n-octanol and naphthalene at 120 °C. It was found that despite their similar chemical compositions, CAPC and HAPC differ largely in their selectivity towards the isomers of alkanes, methylpyridines and xylenes. As demonstrated, the CAPC column exhibits advantageous comprehensive performance over the HAPC column and the commercial PEG column. Particularly, the CAPC column exhibits higher resolving performance towards the isomers indicated above and the Grob mixture than the HAPC column. Also, it shows distinct advantages over the PEG column in separating the Grob mixture, the isomers of diethylbenzenes and cymenes, and practical analysis of chemical products and the essential oil from the leaves of Rhododendron dauricum L. Additionally, the CAPC column has excellent repeatability and reproducibility on analyte retention times with the relative standard deviation (RSD) values in the range of 0.05% - 0.08% for run-to-run, 0.12% - 0.19% for day-to-day and 2.6% - 4.9% for column-to-column, respectively. Its applications to purity test of chemical products and GC-MS analysis of the essential oil demonstrate its promising future for practical GC analyses.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cimento de Policarboxilato / Cromatografia Gasosa Idioma: En Revista: J Chromatogr A Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cimento de Policarboxilato / Cromatografia Gasosa Idioma: En Revista: J Chromatogr A Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China