Your browser doesn't support javascript.
loading
Characterizing the stimulation interference in electroencephalographic signals during brain-computer interface-controlled functional electrical stimulation therapy.
Jovanovic, Lazar I; Popovic, Milos R; Marquez-Chin, Cesar.
Afiliação
  • Jovanovic LI; Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.
  • Popovic MR; The KITE Research Institute, Toronto Rehabilitation Institute-University Health Network, Toronto, Ontario, Canada.
  • Marquez-Chin C; CRANIA, University Health Network, Toronto, Ontario, Canada.
Artif Organs ; 46(3): 398-411, 2022 Mar.
Article em En | MEDLINE | ID: mdl-34460942
INTRODUCTION: The integration of brain-computer interface (BCI) and functional electrical stimulation (FES) has brought about a new rehabilitation strategy: BCI-controlled FES therapy or BCI-FEST. During BCI-FEST, the stimulation is triggered by the patient's brain activity, often monitored using electroencephalography (EEG). Several studies have demonstrated that BCI-FEST can improve voluntary arm and hand function after an injury, but few studies have investigated the FES interference in EEG signals during BCI-FEST. In this study, we evaluated the effectiveness of band-pass filters, used to extract the BCI-relevant EEG components, in simultaneously reducing stimulation interference. METHODS: We used EEG data from eight participants recorded during BCI-FEST. Additionally, we separately recorded the FES signal generated by the stimulator to estimate the spectral components of the FES interference, and extract the noise in time domain. Finally, we calculated signal-to-noise ratio (SNR) values before and after band-pass filtering, for two types of movements practiced during BCI-FEST: reaching and grasping. RESULTS: The SNR values were greater after filtering across all participants for both movement types. For reaching movements, mean SNR values increased between 1.31 dB and 36.3 dB. Similarly, for grasping movements, mean SNR values increased between 2.82 dB and 40.16 dB, after filtering. CONCLUSIONS: Band-pass filters, used to isolate EEG frequency bands for BCI application, were also effective in reducing stimulation interference. In addition, we provide a general algorithm that can be used in future studies to estimate the frequencies of FES interference as a function of the selected stimulation pulse frequency, FSTIM , and the EEG sampling rate, FS .
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia por Estimulação Elétrica / Eletroencefalografia / Interfaces Cérebro-Computador Idioma: En Revista: Artif Organs Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia por Estimulação Elétrica / Eletroencefalografia / Interfaces Cérebro-Computador Idioma: En Revista: Artif Organs Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá