Your browser doesn't support javascript.
loading
A small-scale neutral alumina column chromatography method for carbon isotope determination of hopanes in crude oils or rock extracts.
Lu, Zhongdeng; Chen, Zulin; Liu, Yan; Xu, Yaohui; Wen, Zhigang; Ding, Kangle; Tian, Yongjing.
Afiliação
  • Lu Z; College of Resources, China University of Geosciences, Wuhan, Hubei 430070, China.
  • Chen Z; Key Laboratory of Oil and Gas Geochemistry and Environment in Hubei Province (Yangtze University), Wuhan, Hubei 430100, China. Electronic address: zdl@cug.edu.cn.
  • Liu Y; Key Laboratory of Oil and Gas Geochemistry and Environment in Hubei Province (Yangtze University), Wuhan, Hubei 430100, China.
  • Xu Y; Key Laboratory of Oil and Gas Geochemistry and Environment in Hubei Province (Yangtze University), Wuhan, Hubei 430100, China.
  • Wen Z; Key Laboratory of Oil and Gas Geochemistry and Environment in Hubei Province (Yangtze University), Wuhan, Hubei 430100, China.
  • Ding K; School of Chemical and Environmental Engineering, Yangtze University, Jingzhou, Hubei 434100, China.
  • Tian Y; Division of Science and Technology, Yangtze University, Jingzhou, Hubei 434100, China.
J Chromatogr A ; 1689: 463729, 2023 Jan 25.
Article em En | MEDLINE | ID: mdl-36587588
ABSTRACT
This paper presents a small-scale column chromatography method for separating hopanes in crude oil or rock extracts using neutral alumina as a solid phase adsorbent and a Pasteur pipette as a separation device. Three oil samples were selected to study the effect of solid phase adsorbent type and column length on the separation of hopanes. The oil samples were eluted with mixed reagents (V hexane V petroleum ether = 82) and collected at intervals of 0.5 ml. Ten Fractions were collected and tested for the compounds using GC-MS. A quantitative approach was used to reveal distribution characteristics of compounds in each eluted Fraction. Experimental results showed that 100-200 um neutral alumina exhibited significant differences in the adsorptive capacity of biomarkers from oil samples and rock extracts. The elution order of the biomarkers in the chromatographic column (the length is 180 mm) was n-alkanes, steranes and hopanes. The separation of hopanes could be realized by collecting the eluted Fractions 4 and 5. Compared with the urea complexation, the purity of hopanes separated by column chromatography was higher. The concentration of n-alkanes (nC16-nC34) could be reduced from 1.99 to 4.83 mg/ml to 0.79-0.94 mg/ml, and the content of steranes can be reduced from the original 12% to 0.45%. Residual n-alkanes and steranes were not visible in the GC-MS detection. The Total Ion Chromatography (TIC) of hopanes was consistent with the distribution characteristics of the m/z191 mass chromatogram. The isolated hopanes could meet the detection requirements of isotope ratio mass spectrometry. The C29Ts/C29αß ratio of hopanes decreased gradually from 1.63 to 0.73 as the column length increased. It is speculated that the variation of the C29Ts/C29αß ratio is not only affected by maturity but also by the oil and gas migration. This method is a new attempt in the field of compound purification and can be widely used in the study of stable carbon isotopes of hopanes monomeric hydrocarbons.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Petróleo Idioma: En Revista: J Chromatogr A Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Petróleo Idioma: En Revista: J Chromatogr A Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China